FIGURE 2. This chart shows relative eye sensitivity as a function of light wavelength,
and can be used when evaluating competing industrial area-illumination options. The
goal is to maximize effective lumens (those that can be appropriately utilized by the
human eye). Note that the optimum wavelength selection for safety showers would be
green location lights, since the wavelength falls in the mesopic region between peak
sensitivity for both day and night vision
FIGURE 3. LED-based location lighting is useful for signaling the location of safety
showers and eyewashes, since they remain visible in daylight conditions
CHEMICAL ENGINEERING WWW.CHE.COM APRIL 2010 55
determination of lamp lumens involves
knowing both the spectral power dis-
tribution (SPD) of the lamp and the vi-
sual response of the eye. Interestingly,
it is not simply defined as a form of
energy in the same way as other forms
of radiation; rather, it is defined as en-
ergy as evaluated by the human eye (a
reflection of the visual effect which
differs by individual that is created
by that light energy source).
Color. When it comes to how the eye
responds to color, vision scientists
have known for most of the twentieth
century that lighting conditions play
a big part. While its been widely ac-
cepted that the cones in the eye handle
day vision and the rods are designed
for night vision, up until now light-
ing manufacturers have continued
to rely on light meters to measure a
lamps lumen output that is calibrated
by examining the eyes sensitivity to
only cone-activated (photopic) vision
completely ignoring the effect of
rod-activated (scotopic) vision. Unfor-
tunately this approach represents a
gross oversimplification of how human
vision works, and signals a missed op-
portunity in terms of optimizing in-
dustrial lighting options.
This is perhaps one of the most fas-
cinating and important subjects to be
addressed for efforts to improve in-
dustrial lighting in recent years. In
the past, it has been widely accepted
that under virtually all circumstances
where artificial light is used, light-
ing level calculations could ignore
light source color, relying only on a
certain lamp lumen rating (usually
as provided by the manufacturer). In
these instances, calculated values of
candelas, lumens, or lux (lumens per
square meter) are not dependent upon
whether the light source is white, blu-
ish white, yellow or pink in nature.
However, published research in-
dicates the importance of lamp SPD.
It is only recently that the lighting
industry has begun to acknowledge
the magnitude of the color effects in-
volved, and to show serious interest in
considering the true properties of the
light. With this in mind, some light-
ing experts have started to use the
term effective lumens to define the
modified lumen output of a lamp, tak-
ing into account the shifting color sen-
sitivity of the eye at low light levels.
For example, until recently the
lumen has been defined as the amount
of light as perceived by the eye under
photopic (day) conditions. Based on
this definition, HPS lamps tend to
have high lumen ratings.
However, due to the yellow color
of the source light produced by HPS
lamps, at least half of the light cant
be effectively utilized by human eyes
at night. So, it is not as important that
the sodium lamp produces a high out-
put of energy, but rather that its en-
ergy peak is near the maximum pho-
topic sensitivity wavelength of the eye
(see Figure 2, yellow region).
As a result, one should really deter-
mine the effective lumens of the HPS
light source at scotopic (night) levels.
To do this, the lamp power at each
wavelength would need to be multi-
plied by the scotopic eye sensitivity
at each wavelength, and the values
summed. The effective lumens value,
therefore, will be different from the
conventional lumens value (which, as
noted, is considered only under photo-
pic or daytime conditions).
Because a relatively small portion of
the overall energy output of the HPS
lamp occurs at wavelengths shorter
than the peak, the effective lumens
available for scotopic (night) condi-
tions is greatly reduced. This shows
that sodium lamps (being a source of
yellow light) produce relatively little
useful light (effective lumens) for
nighttime conditions, and therefore
their effectiveness under low light lev-
els when it is essential to have ad-
equate industrial lighting is drasti-
cally reduced.
By contrast, for a white light source,
such as that produced by an LED-
based fixture, the energy output lies in
the high-sensitivity region of the eye
for low light levels (Figure 2).
As a result, the effective lumens in-
crease as the light level is reduced at
night and the eye shifts to a greater
blue/green peak sensitivity.
As shown in Figure 2, the peak sen-
sitivity of the human eye for night vi-
sion is a wavelength of 507 nanome-
ters (nm), and the peak sensitivity of
the human eye for daytime vision is a
wavelength of 555 nm. The region be-
tween these two peaks is referred to
as mesopic viewing conditions. Even
under mesopic viewing conditions,
yellow light sources have reduced ef-
fectiveness, while LED sources have
superior overall effectiveness.
To provide a mechanism to deter-
mine the true quality of light, the
author proposes the concept of a ratio
called the Quality of Light Factor
(QLF) to determine a rating for the
illumination provided by a fixture that
reflects actual lumens utilized by the
human eye. The author proposes that
the value of QLF can be simply defined
as a mininum ratio value for com-
parative purposes. For instance, if an
HPS lamp is rated with a QLF equal
0.0-0.5
0.5-1.0
1.0-1.5
1.5-2.0
2.0-2.5
2.5-3.0
3.0-3.5
3.5-4.0
4.0-4.5
4.5-5.0
5.0-5.5
5.5-6.0
6.0-6.5
6.5-7.0
7.0-7.5
7.5-8.0
8.0-8.5
8.5-9.0
9.0-9.5
9.5-10.0
10.0-10.5
10.5-11.0 3
2.5
2
1.5
1
0.5
0
3 2.5 2 1.5 1 0.5 0 -0.5 -1 -1.5 -2 -2.5 -3
-0.5
-1
Ratio of distance to mounting height
Isofootcandle chart, 8-ft mounting
R
a
t
i
o
o
f
d
i
s
t
a
n
c
e
t
o
m
o
u
n
t
i
n
g
h
e
i
g
h
t
The isofootcandle chart is derived from the candlepower data, and shows exact plots
of equal footcandle levels on the work plane when the fixture is at a designated mounting height.
The color legend represents the intensity (candelas) of a cross-sectional photometric distribution
curve.Isofootcandle chart, 8-ft mounting
FIGURE 4. The photometric data shown here for an LED-based fxture installed at
an 8-ft (2.4-m) mounting height demonstrate how such fxtures can effectively focus
artifcial, industrial white lighting on straight lines and avoid spillage, thereby contrib-
uting to optimum illumination, especially in multi-level platforms
Engineering Practice
56 CHEMICAL ENGINEERING WWW.CHE.COM APRIL 2010
to one, then the QLF of the LED lamp
would need to be rated as a minimum
of 2, as the strength of the scotopic eye
sensitivity of LED light would be a
number of times greater than the sco-
topic eye sensitivity of HPS source.
It is beyond the scope of this article
to recommend actual QLF values that
should be used for different sources
under different conditions. Nonethe-
less, as a general rule of thumb, the
strength of the scotopic eye sensitivity
of an LED is a number of times higher
than that of an HPS source. Thus,
when purchasing industrial lighting
systems, the QLF of an LED-based
system should be rated much higher
than the QLF of a conventional system,
such as one based on HPS lamps.
When it comes to safety shower and
eyewash locations, lights must be visi-
ble under both daytime and nighttime
conditions. The color chart provided
in Figure 2 shows that the best type
of lights for signaling safety showers
and eyewashes are those that provide
a wavelength in the mesopic range (as
described above). As shown in Figure
3, an LED-based light fixture is per-
fectly visible during daytime condi-
tions.
Candela. Candela is a measure of the
intensity of a light source. It relates
to the light focusing capabilities
of a given light fixture and is thus a
function of the light fixtures optical
design.
Coverage. Coverage is a measure of
the amount of effective light that is
spread out for the intended area-illu-
mination application. Adequate cover-
age is achieved through optical design
of the LED fixture, to ensure optimum
light distribution for industrial white
lighting (Figure 4).
Configuration. The configuration
of a balanced lighting layout refers
to the exact positioning of the fix-
tures (Figure 6). Proper configuration
within the industrial space is essen-
tial, and it is achieved by proper spac-
ing between the stanchion mounts of
industrial lights. The goal is to ensure
optimum area illumination that usu-
ally contributes to safety.
Longevity. Longevity is a measure
of how long-lasting a light source is,
and it is a direct contributing factor
to overall facility safety, since it re-
duces the need for maintenance
personnel to climb structures to
maintain or repair light fixtures
or replace bulbs. With this in mind,
the use of state-of-the-art light fix-
tures, such as those based on LED
technology, which tends to have
longer service life compared to
other types of conventional lamp
sources (incandescent, fluorescent
and HPS), typically translates
into improved safety and reduced
maintenance and lifecycle costs.
LED-based lights also tend to have
reduced energy requirements com-
pared to conventional lamp types,
and this helps to provide a rapid
return-on-investment.
Integrity. The integrity of the cho-
sen lighting solution relates to a
fixtures optimized mechanical and
electrical design. For instance, LED
fixtures provide greater integrity
thanks to several modernizing ad-
vances that are now widely available,
such as universal input voltage capa-
bilities and much cooler temperature
ratings. Both of these aspects contrib-
ute to greater integrity, multi-applica-
tion capabilities and improved safety.
LED fixtures are also particularly
useful as a robust light source be-
cause they have no filaments, which
makes them particularly well-suited
for areas that may be exposed to
high vibration.
Additionally, in an LED system,
lumen maintenance is directly propor-
tional to thermal management. LED
systems are typically designed with
cooling fins to compensate for heat
buildup during use (Figure 5).
Recommended practices
Given the discussion presented above,
the author offers the following rec-
ommendations for optimizing light
source efficiency using LED-based
fixtures for hazardous-area illumina-
tion. Although the example discussed
below focuses on a flare-gas-recovery
plant, the following recommendations
can be considered by most chemical
plants, petrochemical units and other
CPI plants.
L fochnoIogy provIdos boffor
directional control of light than is
possible using conventional incan-
descent, fluorescent or HPS lighting
options. This is important in appli-
cations such as gas-recovery units
where numerous railings straight
walkways and multi-level structures
need to be properly illuminated. Un-
like conventional lights, some of to-
days patented LED fixtures contain
several reflectors to further optimize
light distribution. The ability to ef-
fectively focus the light on straight
lines where it is needed helps to
reduce spillage of light beyond the
target focus area to just a few feet.
LED fixtures also require lower
wattage than conventional lighting
compared to incandescent, fluores-
cent or HPS lighting options
Tho IuncfIonaI advanfagos doscrIbod
above also enable LED lights to be
spaced at a greater distance than
what would be required using con-
ventional light fixtures. As a result,
the use of LED fixtures can help
users to reduce the number of light-
ing fixtures required to illuminate
the same area by as much as 50%
compared to the use of conventional
lighting options. The ability to use
fewer lights reduces capital costs,
installation time and costs, mainte-
nance costs and overall energy re-
quirements
!nIIko convonfIonaI IIghfs, foday`s
LED fixtures can easily be installed
using multiple mounting options
(that is, they can be wall-mounted or
stanchion-mounted and can be used
as side-by-side modules (Figure 6).
FIGURE 5. Todays LED-based industrial
lighting fxtures typically include cooling
fns to help disseminate heat buildup during
operation
Dialight
CHEMICAL ENGINEERING WWW.CHE.COM APRIL 2010 57
Large facilities often stock a few
dozen types of lighting fixtures to
be used at different locations, so the
ability to standardize on such multi-
purpose LED fixtures can drasti-
cally reduce the amount of inven-
tory the facility must manage while
still providing the desired lighting
at different locations throughout
the facility
Appropriate lighting plays a critical
role in supporting overall industrial
safety (Figure 7). Understanding the
complex properties of the human vi-
sual system provides us with the an-
swers we need to develop better and
safer lighting fixtures that will have
significant impact on overall facility
safety throughout the CPI.
The lighting profile discussed here
which considers the complex inter-
actions between competing lighting
options and the human eye pro-
vides a new methodology for evaluat-
ing and selecting competing lighting
options that are most appropriate for
industrial applications under both
daytime and nighttime applications.
With the introduction of new LED
lighting technologies in recent years,
it is now possible to provide an ideal
light source one that is designed to
take advantage of maximum retinal
efficiency in the human eye.
The recommendations provided
here aim to help CPI facilities to em-
ploy optimum color and light sources
that would be most compatible with
the physiology and functionality of the
human eye under daytime and night-
time conditions. As discussed, choos-
ing the most appropriate color during
the selection of visual signal lights can
ensure that workers will have clear
and easy access to safety showers and
other critical safety systems at any
time of the day or night.
LED lighting technology lends itself
well to industrial applications that are
considered classified hazardous areas.
A well-designed LED fixture takes
advantage of the directional charac-
terization of the LED and will deliver
more effective lumens to the targeted
application, therefore increasing the
overall system efficacy for area illumi-
nation at CPI plants.
The practical examples presented
demonstrate how the new LED light-
ing technologies in conjunction with
the QLF can contribute to improve-
ment in safety and maintenance and
save energy.
Edited by Suzanne Shelley
Acknowledgement
The author wishes to thank Dialight
Corp. (Farmingdale, N.J.; dialight.
com) for its assistance during the de-
velopment of this article.
Author
Boris Viner is president of
Humatrack SafeLight (P.O,
Box 107, Avon, CT 06001;
Phone: 860-673-3498; Email:
boris.viner@humatrack.com).
He has worked in the light-
ing industry for more than
25 years. He holds a Masters
degree in electrical engineer-
ing and a Masters degree
in management Rensselaer
Polytechnic Inst. (RPI; Troy,
N.Y.). Viner has presented numerous papers at
technical conferences and engineering seminars,
and is a hazardous-area-lighting consultant
to industrial lighting company Dialight Corp.
(www.dialight.com).
FIGURE 6. Shown here is the appropriate positioning of LED-based light fxtures
throughout a typical fare-gas-recovery unit at a petrochemical facility
FIGURE 7. As seen in this photo, taken in the feld at a gas-recovery unit, the use of
new LED-based lighting technologies can lead to tremendous visual acuity improve-
ments at petrochemical facilities by providing adequate light where it is needed the
most (throughout the multi-level platform). Notice that the penetration of the light
from the higher elevation of the structure down to the lower foor, and the distribution
of light throughout the entire structure provides optimum overall illumination
Note: Luminaire refers to a lighting fxture that is complete with installed lamps and other accessories