Sunteți pe pagina 1din 7

Direct Operated Regulator for 6.

0 MPa (Relieving Type)

Series VCHR
Service life: 10 million cycles

Using NSF-H1-certified grease on the guide ring (sliding) part.

Improved durability under a high pressure environment with a polyurethane elastomer poppet

Adopting a metal-sealed relief valve to improve durability.

Special fluoro-resin sealant is adopted for the sliding part.

Stable responsivess after extended disuse. No likely to subject to a pressure.

Made to Order
(Refer to page 635 for details.)

How to Order

VCHR 30
Body size
30 40
Symbol

06 G
Thread type (Conforming to ISO1179-1 on the pneumatic/hydraulic G thread) Port size
Symbol Port size VCHR30

VCHR40

06 10 14

3/4 1 11/2

630

Direct Operated Regulator for 6.0 MPa (Relieving Type)

Series VCHR

Specifications
Model Valve construction Valve material Relief mechanism Port size Thread type Fluid Max. operating pressure Set pressure range Fluid temperature Ambient temperature Mass 4.4 kg G3/4, G1 Air 6.0 MPa 0.5 to 5.0 MPa 5 to 60C 5 to 60C 6.2 kg

VCHR30
Piston type Polyurethane elastomer Relieving type

VCHR40

G1, G11/2

Conforming to ISO1179-1 on the pneumatic/hydraulic G thread

ARJ
AR425 to 935

AMR ARM ARP IR


VCHR40
1.5 1.4 1.3 1.2 1.1 1.0 0.9
Condition: Inlet pressure 4.0 MPa Outlet pressure 1.0 MPa Flow rate 300 l/min (ANR)

Pressure Characteristics
VCHR30
1.5 1.4 1.3 1.2 1.1 1.0 0.9 1.0 2.0 3.0 4.0
Condition: Inlet pressure 4.0 MPa Outlet pressure 1.0 MPa Flow rate 300 l/min (ANR)

IRV VEX1 SRH SRP SRF ARX20 VCHR ITV

Outlet pressure (MPa)

Outlet pressure (MPa)

1.0

2.0

3.0

4.0

Inlet pressure (MPa)

Inlet pressure (MPa)

IC PVQ
VEF VEP

Flow Characteristics
VCHR30
6 5 4 3 2 1 0 0 10,000 20,000 30,000 40,000
Condition: : Inlet pressure : Inlet pressure 6.0 MPa 4.5 MPa

VCHR40
6 5 4 3 2 1 0 0 10,000 20,000

Condition: : Inlet pressure : Inlet pressure

6.0 MPa 4.5 MPa

VER VEA VY2


VBA VBAT

Outlet pressure (MPa)

Outlet pressure (MPa)

AP100

30,000

40,000

50,000

Flow rate (l/min)

Flow rate (l/min)

631

Series VCHR
Construction
Component Parts

!6 !3 i o !4 r @8 q !0 @4 e

@0 @6 @7 @5 !1 !5 !9 @2 @3 !8 !7

No. 1 2 3 4 5 6 7 8 9 Body Bonnet Valve

Description

Material Aluminum + Hard anodized Aluminum + Hard anodized Stainless steel Stainless steel Steel + Electroless nickel plated Steel + Electroless nickel plated Steel + Electroless nickel plated Aluminum + Hard anodized Resin Resin Resin Stainless steel Stainless steel Polyurethane elastomer Polyurethane elastomer Steel + Electroless nickel plated Stainless steel Resin Resin Carbon steel Carbon steel Carbon steel Carbon steel NBR NBR NBR NBR Carbon steel

Valve spool Piston Spring guide Spring seat Spool guide Seal A

10 Seal B 11 Guide ring 12 Adjusting bolt 13 Return spring 14 Cushion 15 Poppet 16 Plate 17 Spring 18 Guide ring 19 Guide ring 20 Hexagon socket head cap screw 21 Hexagon nut

t y u w @1 !2

22 Hexagon bolt 23 Spring washer 24 O-ring 25 O-ring 26 O-ring 27 O-ring 28 Hexagon socket head plug

632

Direct Operated Regulator for 6.0 MPa (Relieving Type)

Series VCHR

Dimensions
VCHR30
90 2 x Rc 1/4: with plug Port size: G3/4, G1 Set pressure detection port 56 60 2 x 10.5

ARJ
AR425 to 935

15

OUT
43: G3/4 40: G1

50

11

IN

103

AMR ARM
215.5

ARP
Max. 269

80

IR IRV VEX1

Relief port
1 1

SRH SRP
40 Adjusting bolt

SRF ARX20

VCHR40
100 2 x Rc 1/4: with plug Set pressure detection port 60 56 11 4 10.5

VCHR ITV IC PVQ


VEF VEP
5

Port size: G1,G11/2

44

10

OUT
85 128

52

IN

VER VEA VY2


269.5 Max. 331

VBA VBAT

AP100

85 Relief port

40

Adjusting bolt

633

Series VCHR

Specific Product Precautions


Be sure to read before handling. Refer to front matters 42 and 43 for Safety Precautions and pages 287 to 291 for Precautions on every series.

Adjustment

Caution
1. When adjusting the outlet side pressure, moment is applied on the adjusting bolt. Support it separately so that moment is not applied to the external pipings.
Reference for Handle Moment
Set pressure Torque 1 MPa 3 2 MPa 6 3 MPa 9 4 MPa 12
Unit: Nm

5 MPa 15

2. When adjusting the outlet side pressure, the adjusting bolt (32 mm width across flats) can be fixed with a wrench. A screwdriver of approximately 20 to 30 cm can also be used for easy adjustments, using the (11) hole on the width across flats.
Piping

Warning
1. When tightening a screw on the piping material, use the recommended torque, holding the female side.
Insufficient torque will cause looseness or inferior sealing. However, overtightening will cause damage to the thread. Also, tightening without holding the female side will put excessive direct stress on brackets, etc., resulting in damage, etc.

Recommended Tightening Torque


Connecting thread Torque 3/4 28 to 30 1 36 to 38

Unit: Nm

11/2 48 to 50

Disassembly

Caution
1. This product cannot be disassembled since it is made of precision components with a specific tolerance.

634

Series VCHR

Made to Order Specifications:


Contact SMC for detailed dimensions, specifications and delivery.

6.0 MPa piloted regulator (Air operated type)


Remote control is possible with electro-pneumatic regulator ITV.

VCHRA
ARJ
AR425 to 935

VCHRA 30
Body size
30 40

06 G
Thread type (ISO1179-1 compliant G thread for hydraulic and pneumatic equipment)

AMR ARM

Port size
Symbol Port size VCHRA30 VCHRA40

Valve material Relief mechanism Port size Port size Thread standard Symbol Fluid Max. operating pressure Pilot pressure range Set pressure range Fluid temperature Ambient temperature Mass

Polyurethane elastomer Relieving type G3/4, G1 G1, G11/2 Conforming to ISO1179-1 on the pneumatic/hydraulic G thread Air 6.0 MPa Refer to the graph. 0.5 to 4.5 MPa 5 to 60C 5 to 60C 2.9 kg 4.1 kg

Outlet set pressure P2 (MPa)

06 10 14

3/4 1 11/2

Specifications
Model Valve construction

Pilot pressure range


VCHRA30 VCHRA40
Piston type

Inlet pressure P1 (MPa)

ARP IR IRV VEX1 SRH

4.0 VCHRA40 PA = 0.171 x P2 + 0.027 x P1 3.0

2.0

1.0

VCHRA30
PA = 0.205 x P2 + 0.017 x P1 0.0 0.0 0.5 1.0

SRP SRF ARX20 VCHR ITV IC PVQ


VEF VEP

Pilot pressure PA (MPa)


Note) Outlet pressure may fluctuate under certain conditions.

VER VEA VY2


VBA VBAT

AP100

635

5.0 MPa

2 AK =JE? Equipment Variation


Example of driving a cylinder
ARJ
AR425 to 935

Applications included air-blowing, charging fluid into a vessel, or discharging (Blow-molding equipment, etc.)

AMR ARM
Check valve Pressure switch Pilot operated 3 port solenoid valve
Medium pressure

VCHC40
IN

ISE75(H)
Pre-forming

ARP IR IRV VEX1

VCH410

Silencer

VCHN3/4

EXH

High pressure

Max.

6.0 MPa
IN

Direct operated regulator (Relieving type)

Die opening/ closing

SRH SRP

VCHR30/40
Description Pilot operated 2 port solenoid valve Features Maximum operating pressure (MPa) Series Port size 1/4 1/2 3/4 1 11/4 11/2 Page Best Pneumatics No. 7 Best Pneumatics No. 7 Best Pneumatics No. 7

Discharging

Charging
OUT

SRF ARX20 VCHR ITV IC PVQ


VEF VEP

VCH41 (N.C.) 5.0 VCH42 (N.O.)


Service life: 10 million cycles
Adopting a polyurethane elastomer poppet in a valve seat. Improved durability under a high pressure environment.

Check valve

5.0

VCHC40

Pilot operated 3 port solenoid valve

5.0

VCH410 VCHR30

Pilot operated 2 port solenoid valve Normally open

Pilot operated 2 port solenoid valve Normally closed

VCH42

VCH41

Direct operated regulator (Relieving type)

Inlet pressure 6.0 Set pressure 0.5 to 5.0

VER
P.630

VCHR40 VCHN3 VCHN4


Best Pneumatics No. 6

VEA VY2
VBA VBAT

Made to Order/Manifold Unit


EXH IN

Noise reduction 35 dB(A)


Silencer
(At supply pressure 4.0 MPa, back pressure 2.0 MPa)

5.0
Relief valve release pressure: 1.8 MPa

Clogging-reduction with double-layer construction

Related Equipment
Pressure switch

AP100
2-color display Metal body
(Aluminum die-cast)

10.0 15.0

ISE75 ( H )

OUT

Medium pressure

Best Pneumatics No. 6

Max.
High pressure

6.0 MPa
IN

Made to Order
1 6.0 MPa pilot operated regulator (Air operated type) 2 22.0 MPa 2 port air operated valve