Sunteți pe pagina 1din 4

w w w . s c h u n k .

c o m 14
Technical data
Moment load
KLM 300
Linear modules Pneumatic Stroke module
Designation KLM 300-H050 KLM 300-H100 KLM 300-H150 KLM 300-H200 KLM 300-H250 KLM 300-H300
ID 0314550 0314554 0314558 0314562 0314566 0314570
Stroke length [mm] 50 100 150 200 250 300
Extend force [FV] at 6 bar [N] 753 753 753 753 753 753
Retract force [FR] at 6 bar [N] 633 633 633 633 633 633
Piston diameter [mm] 40 40 40 40 40 40
Rod diameter [mm] 16 16 16 16 16 16
Overall length [mm] 324 324 524 524 724 724
Mass [kg] 6.9 6.8 9.8 9.7 12.7 12.6
Fluid consumption/10 mm stroke [cm] 12.57 12.57 12.57 12.57 12.57 12.57
Minimum pressure [bar] 3 3 3 3 3 3
Maximum pressure [bar] 8 8 8 8 8 8
Nominal operating pressure [bar] 6 6 6 6 6 6
IP rating 40 40 40 40 40 40
Min. ambient temperature [C] 5 5 5 5 5 5
Max. ambient temperature [C] 60 60 60 60 60 60
Repeat accuracy [mm] 0.015 0.015 0.015 0.015 0.015 0.015
OPTIONS and their characteristics
Dust-protection version ID 0314552 0314556 0314560 0314564 0314568 0314572
Designation KLM 300-H050-SD KLM 300-H100-SD KLM 300-H150-SD KLM 300-H200-SD KLM 300-H250-SD KLM 300-H300-SD
IP rating 64 64 64 64 64 64
Rod lock ID 0314551 0314555 0314559 0314563 0314567 0314571
Designation KLM 300-H050-ASP KLM 300-H100-ASP KLM 300-H150-ASP KLM 300-H200-ASP KLM 300-250-ASP KLM 300-H300-ASP
Stroke loss of nominal stroke (on the rod side) [mm] 22 22 22 22 22 22
Mayy [kg] 7.4 7.3 10.3 10.2 13.2 13.1
Static holding force [N] 1000 1000 1000 1000 1000 1000
max. axial backlash of the clamping [mm] 0.25 0.25 0.25 0.25 0.25 0.25
ZZA intermediate stop on the rod side possible Yes Yes Yes Yes Yes Yes
ZZA intermediate stop side on the piston possible Yes Yes Yes Yes Yes Yes
LMZAW intermedite stop possible No No No No No No
Designation F
y
/F
z
M
x
M
y
M
z
[N] [Nm] [Nm] [Nm]
KLM 300-H050 3120 90 200 200
KLM 300-H100 3120 90 200 200
KLM 300-H150 2490 72 350 350
KLM 300-H200 2490 72 350 350
KLM 300-H250 1870 54 415 415
KLM 300-H300 1870 54 415 415
L = 61 mm
The forces and moments shown here are maximum values
for individual loading. If more than one force or moment
occurs simultaneously, the application can be calculated by
the TOOLBOX sizing software.
V e r k a u f k + 4 9 - 7 1 3 3 - 1 0 3 - 2 5 0 3 T e c h n i k k + 4 9 - 7 1 3 3 - 1 0 3 - 2 6 9 6 15
KLM 300
Linear modules Pneumatic Stroke module
You can find further information and components for the accessories mentioned here in the Accessories part of the catalog.
Main views, KLM 300-H100
Stroke variants
A, a Main and direct connections, extend linear unit
B, b Main and direct connections, retract linear unit
Connection, linear unit
Connection of the assembly
p| On both attachment faces
p Back
p Through-bores in the face plate and thread in the base body (only single sided)
p{ Sensors and shock absorbers can also be fastened to the back. For variant H025, the sensors, shock
absorbers, and the air connections have to be fastened crosswise.
Type Stroke A B C D E G
[mm] [mm] [mm] [mm] [mm] [mm] [mm]
KLM 300-H050 50 324 1x50 4x25 2777 170 12777
KLM 300-H100 100 324 1x50 4x25 27127 170 12727
KLM 300-H150 150 524 3x50 8x25 27177 270 22777
KLM 300-H200 200 524 3x50 8x25 27227 270 22727
KLM 300-H250 250 724 5x50 12x25 27277 370 32777
KLM 300-H300 300 724 5x50 12x25 27327 370 32727
Variable dimensions of stroke variants
The linear module can be fastened either to the base body or the face plates. The
structure can also optionally be fastened to either the face plates or the base body.
This view shows the mounting of the module to the base body and the mounting of
the structure to the face plates.
Not all dimensions shown can be seen in the main view.
w w w . s c h u n k . c o m 16
You can find further information and components for the accessories mentioned here in the Accessories part of the catalog.
KLM 300
Linear modules Pneumatic Stroke module
Rod lock Dust-protection version
p Air connection, rod lock
The rod lock prevents weights from falling in the event of energy loss, such as
emergency stop situations. The rod lock can also be retrofitted, but this will reduce
the useful stroke.

The option dust-protection version increases the degree of protection against the
ingress of materials.
Variable Mae der Absenksperre
Type Stroke D E G
[mm] [mm] [mm] [mm]
KLM 300-H050 28 2755 192 10577
KLM 300-H100 78 27105 192 10527
KLM 300-H150 128 27155 292 20577
KLM 300-H200 178 27205 292 20527
KLM 300-H250 228 27255 392 30577
KLM 300-H300 278 27305 392 30527
Fine adjustment Fine adjustment
pz Stroke
p Stroke adjustment range
p{ Dampening stroke adjustment range
Shock absorbers can be mounted either on the base body or on the face plates. This
illustration shows the mounting on the base body and the possibility of stroke fine
adjustment.
pz Stroke
p Stroke adjustment range
p{ Dampening stroke adjustment range
Shock absorbers can be mounted either on the base body or on the face plates. This
illustration shows the mounting on the face plates and the possibility of stroke fine
adjustment.
V e r k a u f k + 4 9 - 7 1 3 3 - 1 0 3 - 2 5 0 3 T e c h n i k k + 4 9 - 7 1 3 3 - 1 0 3 - 2 6 9 6 17
KLM 300
Linear modules Pneumatic Stroke module
Inductive attachment, NHS
Intermediate stop, ZZA on the piston side Intermediate stop, ZZA on the piston rod side
] Air connection
p Intermediate stroke
p{ Overall length A, the variant without intermediate stroke (see dimension table of stroke variants)
ZZA 305
Holding force at 6 bar [N] 460
Additional mass at 0 mm stroke [kg] 0.75
Additional mass per mm stroke [kg] 0.006
Sample order KLM 300-H100-ZZA305-H100
The intermediate position is measured from the respective end position. The
intermediate position can be approached from both sides and can proceed in the
original stroke direction.. The holding force is the piston force of the intermediate
stop less the piston force of the linear module.
] Air connection
p Intermediate stroke
p{ Overall length A, the variant without intermediate stroke (see dimension table of stroke variants)
ZZA 306
Holding force at 6 bar [N] 460
Additional mass at 0 mm stroke [kg] 0.75
Additional mass per mm stroke [kg] 0.006
Sample order KLM 300-H100-ZZA306-H100
The intermediate position is measured from the respective end position. The
intermediate position can be approached from both sides and can proceed in the
original stroke direction.. The holding force is the piston force of the intermediate
stop less the piston force of the linear module.
End-position monitoring: Inductive proximity switch, can be directly mounted
Designation ID
NI 30-KT 0313429
Extension cable for proximity switch
Designation ID
KA-BG08-L 3P-0500-PNP 0301623
KA BW08-L 3P-0500-PNP 0301502
Generally, two sensors are needed for each linear unit. For additional monitoring of the inter-
mediate positions, one sensor per additional position as well as (optionally) one extension
cable will be needed.
You can find further information and components for the accessories mentioned here in the Accessories part of the catalog.

S-ar putea să vă placă și