Sunteți pe pagina 1din 6

SN54/74LS569A FOUR-BIT UP/DOWN COUNTER WITH THREE-STATE OUTPUTS

The SN54 / 74LS569A is designed as programmable up/down BCD and Binary counters respectively. These devices have 3-state outputs for use in bus organized systems. With the exception of output enable (OE) and asynchronous clear (ACLR), all functions occur on the positive edge of the clock pulse (CP). When the LOAD input is LOW, the outputs will be programmed by the parallel data inputs (A, B, C, D) on the next clock edge. Enabling of the counters occurs only when CEP and CET are LOW and LOAD is HIGH. Direction of the count is controlled by the up-down input (U/D), HIGH counts up and LOW counts down. High-speed counting and cascading is implemented by internal look-ahead carry logic and an active LOW ripple carry output (RCO). On the LS569A, the RCO is LOW at binary 15 during up-count and during down-count it is also LOW at binary 0. During normal cascading operation RCO connected to the succeeding block at CET is the only requisite. When counting and when RCO is LOW, the clocked carry output (CCO) provides a HIGH-LOW-HIGH pulse for a duration equal to the LOW time of the clock pulse. Two active LOW reset lines are provided, a master reset asynchronous clear (ACLR) and a synchronous clear (SCLR). When in a HIGH state, the output control (OE) input forces the counter output into a HIGH impedance state and when LOW, the counter outputs are enabled.

FOUR-BIT UP / DOWN COUNTER WITH THREE-STATE OUTPUTS


LOW POWER SCHOTTKY

20 1

J SUFFIX CERAMIC CASE 732-03

20 1

N SUFFIX PLASTIC CASE 738-03

ESD > 3500 Volts


CONNECTION DIAGRAM (TOP VIEW)

20

DW SUFFIX SOIC CASE 751D-03


1

VCC RCO CCO OE 20 19 18 17

YA 16

YB 15

YC 14

YD CET LOAD 11 13 12 VCC = PIN 20 GND = PIN 10

ORDERING INFORMATION
SN54LSXXXJ Ceramic SN74LSXXXN Plastic SN74LSXXXDW SOIC

Note: Pin 1 is marked for orientation.

1 U/D

2 CP

3 A

4 B

5 C

6 D

8 9 10 7 CEP ACLR SCLR GND

GUARANTEED OPERATING RANGES


Symbol VCC TA IOH IOH IOL IOL Supply Voltage Operating Ambient Temperature Range Output Current High Except RCO, CCO Output Current High RCO, CCO Output Current Low Except RCO, CCO Output Current Low, RCO, CCO Parameter 54 74 54 74 54 74 54, 74 54 74 54 74 Min 4.5 4.75 55 0 Typ 5.0 5.0 25 25 Max 5.5 5.25 125 70 1.0 2.6 0.44 12 24 4.0 8.0 Unit V C mA mA mA mA

FAST AND LS TTL DATA 5-1

SN54/74LS569A
FUNCTION TABLE
INPUTS CP X X X X D C B A X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X LOAD H H H H X X X X X X L X X X X X X X X X CET L L H L L L H L L H X H L L H X L L H X CEP L L X H L H X L H X X X L H X X L H X X U/D H L X X H H H L L L X H L L L H L L L X ACLR H H H H H H H H H H H H H H H L L L L X SCLR H H H H H H H H H H H L L L L X X X X X OE L L L L L L L L L L L L L L L L L L L H RCO A/R A/R H A/R L L H L L H H H L L H H L L H X CCO A/R A/R H H H H H H H H H H H H H X OUTPUTS YD YC YB YA Count Up Count Down Count Inhibit Count Inhibit Overflow Overflow Overflow Inhibit Underflow Underflow Underflow Inhibit Load Example Clear (Synchronous) Clear (Synchronous) Clear (Synchronous) Clear (Synchronous) Asynchronous Clear Asynchronous Clear Asynchronous Clear Asynchronous Clear Output Disabled

(QT CP) + 1 (QT CP) 1 NC NC NC NC NC NC NC NC H H H L L L L L L L L L L L L H H H L L L H L L L L L L L L Hi-Z H H H L L L L L L L L L L L L H H H L L L H L L L L L L L L

L H L H X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

(QT CP) = Output state prior to clock edge NC = No change

A/R = Assumes required output state; High except during Overflow and Underflow

X = Dont care

LOGIC DIAGRAM
* D R CP Q A * YA Q OE ACLR

YB

YC

SCLR LOAD

YD

CEP CET CP U/D

RCO CCO

FAST AND LS TTL DATA 5-2

SN54/74LS569A
DEFINITION OF FUNCTIONAL TERMS A, B, C, D CEP The four programmable data inputs. Count Enable Parallel. Can be used to enable and inhibit counting in high speed cascaded operation. CEP must be LOW to count. Count Enable Trickle. Enables the ripple carry output for cascaded operation. Must be LOW to count. Clock Pulse. All synchronous functions occur on the LOW-to-HIGH transition of the clock. Enables parallel load of counter outputs from data inputs on the next clock edge. Must be HIGH to count. Up/Down Count Control. HIGH counts up and LOW counts down. ACLR Asynchronous Clear. Master reset of counters to zero when ACLR is LOW, independent of the clock. Synchronous clear of counters to zero on the next clock edge when SCLR is LOW. A HIGH on the output control sets the four counter outputs in the high impedance, and a LOW, enables the output.

SCLR OE

CET

CP

YA, YB, YC, YD The four counter outputs. RCO Ripple Carry Output. Output will be LOW on the maximum count on up-count. Upon down-count, RCO is LOW at 0000. Clock Carry Output. While counting and RCO is LOW, CCO will follow the clock HIGH-LOW-HIGH transition.

LOAD

CCO

U/D

LOW-POWER SCHOTTKY INPUT/OUTPUT CURRENT INTERFACE CONDITIONS


DRIVING OUTPUT VCC IOH IOH IIL DRIVING OUTPUT DRIVEN INPUT

IOL

IOL IIH

Note: Actual current flow direction shown

FAST AND LS TTL DATA 5-3

SN54/74LS569A
DC CHARACTERISTICS OVER OPERATING TEMPERATURE RANGE (unless otherwise specified)
Limits S b l Symbol VIH VIL VIK P Parameter Input HIGH Voltage 54 Input LOW Voltage 74 Input Clamp Diode Voltage Output HIGH Voltage VOH RCO, , CCO YA YD 54 74 54 74 54, 74 VOL IOZH IOZL IIH Output LOW Voltage 74 Output Off Current HIGH Output Off Current LOW Input HIGH Current 0.1 Others IIL Input LOW Current CET Short Circuit Current (Note 1) RCO, CCO Others 20 30 0.8 100 130 43 mA mA mA mA VCC = MAX VCC = MAX 0.4 0.35 0.5 20 20 20 V A A A mA mA VCC = MAX MAX, VIN = 0 0.4 4V 2.4 2.4 2.5 2.7 0.65 3.4 3.1 3.5 3.5 0.25 0.4 0.8 1.5 V V V V V V IOL = IOL MAX VCC = VCC MIN, VIN = VIL or VIH per Truth Table VCC = MIN MIN, , IOH = MAX, MAX, VIN = VIH or VIL per Truth Table Min 2.0 0.7 V Typ Max U i Unit V T C di i Test Conditions Guaranteed Input HIGH Voltage for All Inputs Guaranteed Input p LOW Voltage g for All Inputs VCC = MIN, IIN = 18 mA

VCC = MAX, VO = 2.7 V VCC = MAX, VO = 0.4 V VCC = MAX, VIN = 2.7 V VCC = MAX, VIN = 7.0 V

IOS ICC

Power Supply Current, 3-State

Note 1: Not more than one output should be shorted at a time, nor for more than 1 second.

AC CHARACTERISTICS (TA = 25C)


Limits S b l Symbol P Parameter Min Typ Max U i Unit T Test C Conditions di i

FAST AND LS TTL DATA 5-4

fMAX tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPZH tPZL tPHZ tPLZ

Maximum Toggle Frequency Propagation Delay Clock to Q Propagation Delay CET to RCO Propagation Delay U/D to RCO Propagation Delay Clock to RCO Propagation Delay CET to CCO Propagation Delay CEP to CCO Propagation Delay Clock to CCO Propagation Delay ACLR to Q Output Enable Time Output Disable Time

35 15 20 14 15 20 24 20 25 16 28 16 26 15 17 22 32 15 20 20 27

MHz ns ns ns ns ns ns ns ns ns ns CL = 5.0 pF

VCC = 5.0 50V CL = 45 pF RL = 667

FAST AND LS TTL DATA 5-5

SN54/74LS569A
AC SETUP REQUIREMENTS (TA = 25C, VCC = 5.0 V)
Limits S b l Symbol tW ts ts ts ts ts th trec P Parameter Clock Pulse Width (Low) Setup Time, A, B, C, D Setup Time, SCLR Setup Time, LOAD Setup Time, U/D Setup Time, CET, CEP Hold Time, Any Inputs ACLR Min 20 20 20 25 30 20 0 15 Typ Max U i Unit ns ns ns ns ns ns ns ns VCC = 5 5.0 0V T C di i Test Conditions

MICROPROGRAMMABLE DUAL-EVENT 8-BIT COUNTERS


LOAD1 U/D1 COUNT1 ACLR1 OE1 LOAD2 U/D2 COUNT2 ACLR2 OE2

CP AD ACLR U/D OE LOAD CET CEP YAD RCO LS569A

CP AD ACLR U/D OE LOAD CET CEP YAD LS569A

CP AD ACLR OE U/D LOAD CET CEP YAD RCO LS569A

CP AD ACLR U/D OE LOAD CET CEP YAD LS569A

4 8BIT BUS

FAST AND LS TTL DATA 5-6

S-ar putea să vă placă și