XFP100E CB1 50HZ

Letterkenny - WAS Pumps at max head (16.67 l/s @ 14.92m)


Testnorm ISO 9906 Gr 2
/4 60 PE 5 EZ 0H

H [m] 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 P2 [kW] 7 6 5 4 3 70 60 50 40 30 20 10 Hydraulic efficiency 3 3

69.5%

Hydr.eff.

10

15

20

25

30

35

40

45

50

Q [l/s] 2011-06-29

Operating data specification Flow Static head Shaft power Fluid Nature of system Pump data Type Series N of vanes Free passage Discharge port Motor data Rated voltage Rated power P2 Number of poles Power factor Starting current Starting torque Insulation class

16.2 l/s 14.4 m 4.26 kW Water Single head pump XFP100E CB1 50HZ XFP PE1-PE3 1 80 mm DN100 400 V 6 kW 4 0.71 88.3 A 81.8 Nm H

Head Efficiency NPSH Temperature No. of pumps Make Impeller Impeller size Suction port

14.9 m 55.8 % 1.4 m 4 C 1 ABS Contrabloc Plus impeller, 1 vane 225 mm DN100

Frequency Nominal speed Efficiency Rated current Rated torque Degree of protection

50 Hz 1470 rpm 89.8 % 13.6 A 39 Nm IP68

ABS reserves the right to change any data and dimensions without prior notice and can not be held responsible for the use of information contained in this software.

ABSEL PRO 1.7.2 / 2006-12-21

Pump performance curves

Curve number Reference curve

XFP100E CB1 50HZ


Discharge

XFP100E CB1
Frequency

Letterkenny - WAS Pumps at max head (16.67 l/s @ 14.92m)


Density Viscosity Testnorm

DN100
Rated speed

50 Hz
Date

1 kg/dm
Flow

1.57 mm/s
Head

ISO 9906 Gr 2
Rated power

1470 rpm
Hydraulic efficiency

2011-07-19
NPSH

16.2 l/s
H [m] 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 P2 [kW] 7 6 5 4 3 70 60 50 40 30 20 10 0

14.9 m

4.26 kW

55.8 %

1.4 m

Hydraulic efficiency

60 PE 0 -5 -E /4 HZ

69.5%

Hydr.eff.

12

16

20

24

28

32

36

40

44

48

52

Q [l/s]

Impeller size

N of vanes

Impeller

Solid size

Revision

2011-06-29

225 mm

Contrabloc Plus impeller, 1 vane

80 mm
ABSEL PRO 1.7.2 / 2006-12-21

ABS reserves the right to change any data and dimensions without prior notice and can not be held responsible for the use of information contained in this software.

XFP100E CB1 50HZ


Letterkenny - WAS Pumps at min head (16.67 l/s @ 14.4m)
Testnorm ISO 9906 Gr 2

H [m] 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 P2 [kW] 7 6 5 4 3 70 60 50 40 30 20 10 Hydraulic efficiency


/4 60 PE 5 EZ 0H

69.5%

Hydr.eff.

10

15

20

25

30

35

40

45

50

Q [l/s] 2011-06-29

Operating data specification Flow Static head Shaft power Fluid Nature of system Pump data Type Series N of vanes Free passage Discharge port Motor data Rated voltage Rated power P2 Number of poles Power factor Starting current Starting torque Insulation class

17.1 l/s 8.2 m 4.32 kW Water Single head pump XFP100E CB1 50HZ XFP PE1-PE3 1 80 mm DN100 400 V 6 kW 4 0.71 88.3 A 81.8 Nm H

Head Efficiency NPSH Temperature No. of pumps Make Impeller Impeller size Suction port

14.7 m 57.4 % 1.4 m 4 C 1 ABS Contrabloc Plus impeller, 1 vane 225 mm DN100

Frequency Nominal speed Efficiency Rated current Rated torque Degree of protection

50 Hz 1470 rpm 89.8 % 13.6 A 39 Nm IP68

ABS reserves the right to change any data and dimensions without prior notice and can not be held responsible for the use of information contained in this software.

ABSEL PRO 1.7.2 / 2006-12-21

Pump performance curves

Curve number Reference curve

XFP100E CB1 50HZ


Discharge

XFP100E CB1
Frequency

Letterkenny - WAS Pumps at min head (16.67 l/s @ 14.4m)


Density Viscosity Testnorm

DN100
Rated speed

50 Hz
Date

1 kg/dm
Flow

1.57 mm/s
Head

ISO 9906 Gr 2
Rated power

1470 rpm
Hydraulic efficiency

2011-07-19
NPSH

17.1 l/s
H [m] 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 P2 [kW] 7 6 5 4 3 70 60 50 40 30 20 10 0

14.7 m

4.32 kW

57.4 %

1.4 m

Hydraulic efficiency

60 PE 0 -5 -E /4 HZ

69.5%

Hydr.eff.

12

16

20

24

28

32

36

40

44

48

52

Q [l/s]

Impeller size

N of vanes

Impeller

Solid size

Revision

2011-06-29

225 mm

Contrabloc Plus impeller, 1 vane

80 mm
ABSEL PRO 1.7.2 / 2006-12-21

ABS reserves the right to change any data and dimensions without prior notice and can not be held responsible for the use of information contained in this software.

Motor performance curve

Frequency

50 Hz

PE60/4-E-50HZ
Letterkenny - WAS Pumps at max head (16.67 l/s @ 14.92m)
Rated power Service factor Nominal speed Number of poles Rated voltage Date

6 kW

1470 rpm

400 V

2011-07-19

P [kW] 1.4 1.3 M/Mn 1.2 1.1 1 0.9 0.8 cos 0.7 0.6 P1 0.5 0.4 0.3 0.2 0.1 0 20 40 60 80 100 120 s P2/P2n [%] P2 7.5 6 4.5 3 1.5 0 10.5 9 I/In 18 16.5 15 13.5 12 21 19.5

n/ns eff

Loading P1 [kW] P2 [kW] I [A] eff [%] cos n [rpm] M [Nm] s [%]

No load 0.4358 0 8.997 0 0.06992 1500 0 0

25 % 1.854 1.5 9.214 80.92 0.2904 1492 9.6 0.5333

50 % 3.414 3 10.07 87.88 0.4892 1484 19.3 1.067

75 % 5.038 4.5 11.53 89.32 0.6308 1476 29.11 1.6

100 % 6.679 6 13.59 89.83 0.7096 1468 39.03 2.133

125 % 8.472 7.5 16.3 88.53 0.7501 1460 49.05 2.667

Tolerance according to VDE 0530 T1 12.84 for rated power


Starting current Starting torque Moment of inertia

88.3 A

81.8 Nm

0.011 kg m
ABSEL PRO 1.7.2 / 2006-12-21

ABS reserves the right to change any data and dimensions without prior notice and can not be held responsible for the use of information contained in this software.

S-ar putea să vă placă și