Documente Academic
Documente Profesional
Documente Cultură
AC: 24, 42, 48, 110, 115, 120, 230, 240 V DC: 24 V 85 ... 110 % Approx. 2 W/4 VA Max. 20 % 24 VDC, 40 mA
AC1: 240 V/6 A/1500 VA DC1: 24 V/6 A/150 W AC15: 230 V/5 A; DC13: 24 V/6 A 2 safety contacts (N/O) 6 A quick or 4 A slow
Safety gate monitor in accordance with VDE 0113-1, 11/98, EN 60204-1, 12/97 and IEC 204-1, 11/98.
Features G Simultaneity monitoring G Automatic reset possible G Start-up test after supply voltage is applied
Approx. 50 ms Approx. 30 ms AC: approx. 250 ms, DC: approx. 500 ms Approx. 4 s 10 ms
Approvals PST 1 G
TV Wien
1.2 Nm (screws) 2 x 2.5 mm 2 Single-core or multi-core with crimp connectors 87 x 45 x 110 mm AC: 380 g, DC: 280 g
Description G 45 mm, P-75 housing, DIN-Rail mounting G Positive-guided relay outputs: 2 safety contacts (N/O) G Connection for safety gate limit switch G Increase in the number of safety contacts available by connecting expander modules.
G G G
Pilz GmbH & Co., Felix-Wankel-Strae 2, 73760 Ostfildern, Deutschland Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-073-03/01
A1 (L+)
A2 (L-)
Input circuit
S12 S11
Safety contacts
13 23
G Example 3 Dual-channel safety gate control with simulation for opening and closing the safety gate.
S12 X1 X2
F1
K1
S1
S3 S11 S23
G1
~ =
2
Function Diagram
UB S2
S24
S24 S23 14 24
Input circuit
Key
S1/S2: E-STOP or safety gate switch S3: Reset button Switch operated Gate open Gate closed
S1 X1-X2
13-14
t0 tg t2 t3 tg t2 tg t3 t2
G Increase in safety contacts The number of output contacts can be increased by using expander modules or relays/contactors with positive-guided contacts.
t 0: tg: t 2: t 3:
UB must be present for a minimum of 500 ms before S2 Simultaneity approx. 4 s Operating cycle is ended using S1 or S2 X1-X2 must be closed for a minimum of 500 ms before S1
1L1
K3
K4 X2 13
External Wiring G Example 1 Dual-channel safety gate control with position monitoring.
S11 S1 S12 S23 S2 X1
X1
G Example 2 Dual-channel safety gate control with function and start-up testing.
14
S11 S1 X1
K3 1L2
S12 S23 S2
K4
S24
X2
S24
X2
Pilz GmbH & Co., Felix-Wankel-Strae 2, 73760 Ostfildern, Deutschland Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-073-03/01
50 ... 60 Hz 160 % AgSnO2 100 % EN 50081-1, 01/92, EN 61000-6-2, 03/00 Frequency: 10 ... 55 Hz, Amplitude: 0.35 mm DIN IEC 60068-2-3, 12/86 DIN VDE 0110 part 1, 04/97 -10 ... +55 C -40 ... +85 C 0.6 Nm (screws) Any Thermoplast Noryl SE 100 Mounting: IP 54 Housing: IP 40 Terminal Range: IP 20
The units were tested in accordance with the relevant standards current at the time of development.
Order References Type PST 1 PST 1 PST 1 PST 1 PST 1 PST 1 PST 1 PST 1 PST 1 UB 24 V DC 24 V AC 42 V AC 48 V AC 110 V AC 115 V AC 120 V AC 230 V AC 240 V AC Order No. 420 080 420 000 420 010 420 020 420 030 420 035 420 040 420 050 420 055
Pilz GmbH & Co., Felix-Wankel-Strae 2, 73760 Ostfildern, Deutschland Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-073-03/01