NOTE: It is required to configure ports 9-16 to which Slave controllers have been connected. See Step-9.
QIS_SC450_709C004204_Rev A00_07SEP11
For connection to a single Remote Base Unit: At Main site, connect SC-450 ports 1 to 16 to the 330 Main COM 1/2. At Remote site, connect the 330 Remote to the Base Unit COM port.
2. Select Internet Protocol (TCP/IP) Connection and choose Properties. 3. Select Use the following IP Address, and set the parameters as follows: IP Address: 10.0.0.x (x = 2 to 254) Subnet Mask: 255.255.255.0
WARNING: Do NOT connect the SC-450 LOCAL port to a network as its DHCP server can disrupt LAN IP addressing.
3. The SC-450 Controller Login window appears. Type the User Name engineer and the default Password eng (case sensitive). 4. The SC-450 Web Management application window appears.
QIS_SC450_709C004204_Rev A00_07SEP11
2. In the Slave Mask pane, click the Modify button and select Slave for ports (9 to 16) to which Slave controllers are or will be connected. 3. Click OK. The Slave controllers appear in the Network Topology along with the devices under their control.
NOTE: To reset the port for RIU or BU connection, select the Device option.
Corning MobileAccess 8391 Old Courthouse Road, Suite 300, Vienna, VA 22182 Tel:+1(866)436-9266, +1(703)848-0200 TAC: +1(800)787-1266, Fax: +1(703)848-0280 http://www.corning.com/mobileaccess