Sunteți pe pagina 1din 2

OMNI II

TOuch ScreeN PaTIeNT MONITOr

ecG, SPO2, NIBP, hr, TeMP, reSP.


n 12.1” color TFT display with n Built-in thermal recorder. n compact design is convenient for
touch screen. mobile monitoring.
n Large font display with 4, 6 and
n Multi-lead ecG monitoring. 8 waveforms shown. n Multi-lingual settings.

n Touch screen user interface. n Networkable with central n 48 hours trend data analysis.
Monitoring System via a wireless
n Built-in battery. n OPTIONaL: Dual IBP, etcO2,
or wired network.
Battery, recorder.
n NIBP list display.
OMNI II TECHNICAL SPECIFICATIONS

Physical Dimensions & Weight ECG (cont.) SPO2


Main Unit Alarm Limit Range Setting ASpO2: Anti-motion SpO2
Dimension: 555mm H x 335mm W x 235mm D Upper limit: 80-400bpm SpO2% Range: 0-100%
Weight: 5kg Lower limit: 20-150bpm SpO2 Accuracy: + 2% 70-100%, non-motion
+ 3% 70-100%, motion
Application RESP Pulse Rate Range: 30-250 bpm
Neonatal, pediatric and adult patients Measure Method: RA-LL impedance Pulse Rate Accuracy: ±2 bpm (non-motion)
Range: 0-120 rpm ±3 bpm (motion)
Operation Environment Accuracy + 3 rpm Alarm Upper-lower Limit Setting:
Power Alarm Upper-lower Limit Setting: upper limit 70-100%
Source: External AC power or internal battery Upper limit: 6-120 rpm, lower limit 70-100%
AC Power: 100-240VAC, 50/60Hz, <150VA Lower limit: 3-120 rpm SpO2 Probe
Battery: Rechargeable Lead-Acid Sweep Speed: 12.5 and 25 mm/s Red light LED wavelength 660nm±5nm
Operating time under the normal Infrared light LED wavelength 940nm±10nm
condition: 1 hour NIBP
Operating time after the first alarm of Measuring Technology: Automatic oscillating measurement IBP (OPTION)
low battery: 10 mines Cuff Inflating: <30s-0-300 Measurement Range: -10-300mmHg
Temperature mmHg, standard Channel: 2 channels
Working: 5-40C adult cuff Pressure transducer: sensitivity, 5µV/V/mmHg
Storage: -20-65C Measuring Period: AVE<40s Impedance range: 300-3000Ω
Relative Humidity Mode: Manual, Auto, STAT Transducer sites: ART, PA, CVP, RAP, LAP, ICP
Working: 30-75% Measuring Interval in AUTO Mode: Resolution: 1mmHg
Storage: ≤80% 2 min-4 hrs Accuracy: ±1mmHg or ±2%, whichever is greater
Altitude Pulse Rate Range: 30-250 (bpm) Alarm range: -10-300mmHg
Operating Altitude: Up to 5,000 meters Measuring Range: Adult/Pediatric Mode
Hyperbaric Pressure: Up to 405.3 kPa SYS 40-250 (mmHg) EtCO2 (OPTION)
DIA 15-200 (mmHg) Mode of Sampling: Sidestream
Peformance Specifications Neonatal Mode Principle of Operation: Non-dispersive infrared (NDIR) single
Display: 12.1” color TFT, Touch Screen SYS 40-135 (mmHg) beam optics, dual wavelength, no
Resolution: 800 x 600 pixels DIA 15-100 (mmHg) moving parts.
Trace: 4, 6 or 8 waveforms Resolution: 1mmHg CO2 measurement Range:
ECG (I, II, III, aVR, aVL, aVF, V1-V6), Accuracy: Pressure 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)
PLETH, RESP, IBPx2, ETCO2 Maximum Mean error: ±5mmHg CO2 Calculation Method:
Indicator: Alarm indicator Maximum Standard deviation: 8mmHg BTPS (Body Temperature Pressure Saturated)
Power indicator Overpressure Protection: CO2 Resolution: 0.1mmHg(0-69mmHg),
QRS beep and alarm sound Adult Mode 280(mmHg) 0.25mmHg(70-150mmHg)
Trend time: 48 hours Neonatal Mode 150 (mmHg) CO2 Accuracy: 0-40 mmHg ± 2 mmHg
Recorder: Built-in, thermal array, 2 channels Alarm Limit Setting 41-70 mmHg ± 5% of reading
Record width: 48mm SYS 50-240 mmHg 71-100 mmHg ± 8% of reading
Recorder paper: 50mm DIA 15-180 mmHg 101-150 mmHg ± 10% of reading
Record speed: 25mm/s, 50mm/s Above 80 breath per minute ± 12%
TEMP of reading
ECG Range: 25-50C Sampling rate: 100Hz
Input: 5-lead ECG cable and standard AAMI Accuracy: + 0.2C 25.0-34.9C Respiration Rate: 2-150 bpm
line for connection + 0.1C 35.0-39.9C Respiration Rate accuracy: ±1 breath
Lead Choice: I, II, III, aVR, aVF, aVL, V + 0.2C 40.0-44.9C Response Time: <3 seconds - includes transport time
Gain Choice: x0.5, x1.0, x2.0 + 0.3C 45.0-50.0C and rise time
Frequency Characteristic: 0.05-40 Hz Display Resolution: 0.1C Inspired CO2 measurement Range:
ECG Waveforms: 7 channels Alarm Upper-lower Limit Setting: 3-50 mmHg
Penetration Voltage: 4000VAC 50/60Hz Upper limit 0-50C
Sweep Speed: 12.5, 25 and 50 mm/s Lower limit 0-50C Specifications subject to change without notice.
HR Display Range: 30-300bpm Channel: 2 channels
Accuracy: ±1% or ±1bpm, whichever is greater Alarm Limit Setting: 10-50C

Selectable Screens:
4, 6, or 8 waveforms

S-ar putea să vă placă și