ORIFICE FLOWMETER

RDP-100 RDP-505
STEAMGASLIQUID

ORIFICE FLOWMETER RDP-100 RDP-505

WEB PRODUCTS GUIDE

ORIFICE FLOWMETER

WPG-RDP-E02

RDP-100 are ORIFICE FLOWMETER suitable for


the steam, the gas, and the liquid which arranged
an Orifice, DP Transmitter, and Indicator compactly.
This Flowmeter does not have a movable part and
it is preeminent for reliability and durability.
Since D.P. Transmitter is using the shock-proof
type by the object for high pressures, it is the safe
design which is equal also to severe use.
The measurement range can perform wide range
measurement or more in a maximum of 1:10.

RVF-36A-1-XBXA
Fluids

STEAM GAS LIQUIDS


Wafer typeJIS10K JIS20K

Flange type JIS10K JIS20K

25 40 50 65 80 100 125 150

25 40 50 65 80 100 125 150 200 250 300 350

Meter SizeA
Body

standardSUS304 order)SUS316

standardSGP

STPG orderSUS304

Orifice

standardSUS304 order)SUS316

standardSUS304 orderSUS316

RDP100Ugasliquid
RDP100US
steam
RDP100UM gas mani.valve
RDP100USMsteam mani.valve

RDP100Fgasliquid
RDP100FS
steam
RDP100FMgas mani.valve
RDP100FSMsteam mani.valve

Material

Model
Flow direction

Horizontal and

Vertical

Accuracy

1 FS

Max. operating pressure

It is based on flange rating.

Transmitter max. pressure

13.8 MPa

Transmitter Power supply


Output signal

1236V DC
420mA DC D.P. proportionality

Operation temperature

2 wire
Load Resistance 55024VDC

10 200

Ambient temperature

10

80

Ambient humidity

0 100 RH without dew condensation

Options

Manifold ValveSUS316I recommend installation.

Indicator Model
Power supply
Flow rate display
Totalizing flow display

RVF36A1XBXA

Extraction of a square root function

85264 V AC 5060 Hz Power consumption10VA


Red 5 figures of LED (upper row)

Simultaneous display

Red 8 figures of LED

Simultaneous display

Input signal

(lower berth)

420mA DC 2 wire

Input signal Low cut

0.01 10.00

Power supply for Transmitter

24V DC 40mA 2 wire


420mA DC Proportional to Flow rate 12 bit4096 Load Resistance 750

Output signal
Scaled pulse Open collector 30V DC 50mA Max.
Ambient humidity

0 50

3080 RH without dew condensation

RVF-36A-1-XBXA serves as standard attachment by the model designed to exclusive use according to PDP-100.

RYUTAI KOGYO CO.,LTD.

216

ORIFICE FLOWMETER RDP-100 RDP-505

WEB PRODUCTS GUIDE

ORIFICE FLOWMETER

WPG-RDP-E02

RDP-505 are ORIFICE FLOWMETER suitable for the steam, the


gas, and the liquid which arranged an Orifice, DP Transmitter,
and Indicater compactly.
This Flowmeter does not have a movable part and it is
preeminent for reliability and durability.
Since DP Transmitter is using the shock-proof type by the
object for high pressures, it is the safe design which is equal
also to severe use.
The measurement range can perform wide range
measurement or more in a maximum of 1:10.

RVF-36A-1-XBXA

Fluids

Option

STEAM GAS LIQUIDS


Wafer typeJIS10K JIS20K

Flange type JIS10K JIS20K

25 40 50 65 80 100 125 150

25 40 50 65 80 100 125 150 200 250 300 350

Meter SizeA
Body

standardSUS304 order)SUS316

standardSGP

STPG orderSUS304

Orifice

standardSUS304 order)SUS316

standardSUS304 orderSUS316

RDP505Ugasliquid
RDP505US
steam
RDP505UM gas mani.valve
RDP505USMsteam mani.valve

RDP505Fgasliquid
RDP505FS
steam
RDP505FMgas mani.valve
RDP505FSMsteam mani.valve

Material

Model

Flow direction

Horizontal and

Vertical

Accuracy

1 FS

Max. operating pressure

It is based on flange rating.

Transmitter max. pressure

25 MPa

Transmitter Power supply


Output signal

10.555V DC
420mA DCFlow rate proportionality 2 wier

Operation temperature
Ambient temperature
Ambient humidity
Options

2 wire
Load Resistance 55024VDC

10 200
10 80

Explosion proof1070

0 100 RH without dew condensation


Explosion proof TS EXsdCT5

Manifold ValveSUS316

RVF-36A-1-XBXA

Indicator Model

RVF36A1XBXA

Power supply

85264 V AC 5060 Hz Power consumption10VA

Flo rate display


Totalizing flow display

Red 5 figures of LED (upper row)

Simultaneous display

Red 8 figures of LED

Simultaneous display

(lower berth)

Input signal

420mA DC 2 wire

Input signal Low cut

0.01 50.00

Power supply for Transmitter

24V DC 40mA 2 wire


420mA DC Proportional to Flow rate 12 bit4096 Load Resistance 750

Output signal
Scaled pulse Open collector 30V DC 50mA Max.
Ambient humidity

0 50

3080 RH without dew condensation

In model RDP-505, RVF-36A-1-XBXA serves as an option.

RYUTAI KOGYO CO.,LTD.

316

ORIFICE FLOWMETER RDP-100 RDP-505

WEB PRODUCTS GUIDE

WPG-RDP-E02

RDP-100 Flange for STEAM

Outside dimension
RDP-100 Wafer for STEAM

An eyebolt is attached more than 50A.

RDP-505 Flange for STEAM

An eyebolt is attached more than 50A.

RDP-505 Wafer for STEAM

An eyebolt is attached more than 50A.

JIS10K Flange type mm


An eyebolt is attached more than 50A.
The form of DP Transmitter and magnitude have a
difference of the appearance of RDP-100 and
RDP-505, and RDP-505 become somewhat small.

JIS10K Wafer type mm

Size

BOLT

Weight kg

25A

180

40A

180

27.6

90

125

14

M164

340

41.6

105

140

16

M164

345

50A

180

52.9

120

155

16

M164

355

10

65A

200

67.9

140

175

18

M164

365

12

80A

200

80.7

150

185

18

M168

370

13

200

105.3

175

210

18

M168

380

16

M208

395

20

M208

Size

Weight kg

100A

25A

100

27.6

74

340

7.0

125A

200

130.8

210

250

20

40A

100

41.6

89

345

7.5

150A

200

155.2

240

280

22

410

23

200

200

290

330

22

M2012 580

27

50A

100

52.9

104

355

8.5

200A

65A

100

67.9

124

365

10.5

250A

200

249

355

400

24

M2212 615

40

80A

100

80.7

134

370

11.0

300A

200

300

400

445

24

M2216 630

46

100A

100

105.3

159

380

14.5

350A

200

333

445

490

26

M2216 650

58

125A

100

130.8

190

395

18.5

150A

100

155.2

22

410

22.0

d dimension may change with piping quality of the materials.


JIS16K JIS20K L dimension 25A-150A are the same as JIS10K.
JIS16KJIS20K L dimension 200A-350A are set to 250mm.

RYUTAI KOGYO CO.,LTD.

416

ORIFICE FLOWMETER RDP-100 RDP-505

WEB PRODUCTS GUIDE

Outside dimension
RDP-100 GASLIQUID

WPG-RDP-E02

RDP-100 GASLIQUID Flange type

Wafer type

JIS10K Flange type

JIS10K Wafer type mm


Size

Weight kg

25A

100

27.6

74

340

6.5

40A

100

41.6

89

345

7.0

50A

100

52.9

104

355

8.0

65A

100

67.9

124

365

10.0

80A

100

80.7

134

370

10.5

100A

100

105.3

159

380

14.0

125A

100

130.8

190

395

17.5

150A

100

155.2

22

410

21.5

H dimension may differ from a table with


specifications, such as fluid temperature.
In the case of level piping of a liquid, please attach
so that DP Transmitter becomes sideways.
In above and down, the case where exact
measurement cannot be performed in response to
the influence of air bubbles and garbage arises.
IndicatorRVF-36A-1-XBXA

mm

Size

BOLT

Weight kg

25A

180

27.6

90

125

14

M164

340

40A

180

41.6

105

140

16

M164

345

50A

180

52.9

120

155

16

M164

355

10

65A

200

67.9

140

175

18

M164

365

12

80A

200

80.7

150

185

18

M168

370

13

100A

200

105.3

175

210

18

M168

380

16

125A

200

130.8

210

250

20

M208

395

20

150A

200

155.2

240

280

22

M208

410

23

200A

200

200

290

330

22

M2012

580

27

250A

200

249

355

400

24

M2212

615

40

300A

200

300

400

445

24

M2216

630

46

350A

200

333

445

490

26

M2216

650

58

H dimension may differ from a table with specifications, such as fluid


temperature.
d dimension may change with piping quality of the materials.
JIS16K JIS20K L dimension 25A-150A are the same as JIS10K.
JIS16KJIS20K L dimension 200A-350A are set to 250mm.

Dimension mm

RYUTAI KOGYO CO.,LTD.

516

ORIFICE FLOWMETER RDP-100 RDP-505

WEB PRODUCTS GUIDE

WPG-RDP-E02

Electric Wiering
RVF-36A-1-XBXA

RDP-100 Terminal details


Electric wire connection
G1/2 or NPT1/2 Two

When RDP-100 supply 24VDCPower(s), 4 - 20mADC signal


proportional to diff.press. is outputted.
Flow rate display, Totalizing flow display, a pulse output, 4 20mADC output, and the various functions method of application
become possible by using RVF-36A-1-XBXA.
In the zero point adjustment whose Flow rate uses the check and
drain valve of an output signal in zero, COM and a TEST terminal
connect and use a tester.
Since there is no Display (RVF-36A) with waterproofing structure,
attachment to the outdoors cannot be performed.

RDP-505 Terminal details

RVF-36A-1-XBXA

Electric wire connection


G1/2 or NPT1/2 Two

When RDP-505 supply 24VDC power sources, the 4 to20mADC signal


proportional to Flow rate is outputted.
Flow rate display, Totalizing flow display, a pulse output, 4 - 20mADC output,
and the various functions method of application become possible by using
RVF-36A-1-XBXA.
In the zero point adjustment whose Flow rate uses the check and drain valve
of an output signal in zero, COM and a TEST terminal connect and use a
tester.
Since there is no Display (RVF-36A) with waterproofing structure, attachment
to the outdoors cannot be performed.

RYUTAI KOGYO CO.,LTD.

616

ORIFICE FLOWMETER RDP-100 RDP-505

WEB PRODUCTS GUIDE

WPG-RDP-E02

Notes
The straight of the regular length is needed for the entrance side of Flowmeter, and an outlet side, respectively.
Straight length changes with a piping situation, existence of a valve, etc.
Keep in mind that accuracy worsens when there is no regular straight length.

In the case of others


When there are two elbows in an entrance side: More than 18D
When the globe valve of full admission is in an entrance side: More than 20D
When the partition valve of full admission is in an entrance side: More than 20D
All outlet sides are required more than 6D.
It is D= piping bore here.

Please unite the flow direction of Flowmeter, and the flow direction of fluid.
Please provide a work space for the perimeter of the place in which Flowmeter is
attached in consideration of the maintenance after attachment.
Please attach after carrying out Flushing of the piping, in case Flowmeter is at
tached after constructing new piping.
When the possibility of a freeze is in winter, please perform heat insulation disposal to Flowmeter.
Please open a valve gradually for an impact not to join Flowmeter at the time of a startup.

Attention of the installation direction (steam)

Attention of the installation direction (liquid)

In the case of steamy level piping, please attach so that


D.P.transmitter becomes right under or the bottom of
slanting. When there is no space attached directly under
piping, it can install also under slanting.

In the case of level piping of a liquid Please attach so that


D.P.transmitter becomes a level (transverse direction).
In above or down, the case where exact measurement cannot
be performed in response to the influence of air bubbles and
garbage arises.

Removal of Flowmeter, and the notes at the time of decomposition


When removing Flowmeter attached in piping by the bolt nut or screw connection, the pressure in piping is
perfect. Please remove after checking certainly that there is nothing and loosening a connection gradually.
While passing fluid for piping, or when pressure has joined piping, they are a bolt nut or screw connection.
Please do not remove. If it removes recklessly, there is a possibility that harm may join a human body.
Please do not perform reconstruction of Flowmeter. Please contact our company, when you check Flowmeter.

RYUTAI KOGYO CO.,LTD.

716

ORIFICE FLOWMETER RDP-100 RDP-505

Flowrate range Saturated steam -1

RDP-100

WEB PRODUCTS GUIDE

WPG-RDP-E02

RDP-505

Pressure

Maximum flowrange

kPaG

kg/h

25A

40A

50A

Meter Size
65A

80A

100

Minimum

25

40

80

120

200

300

Maximum

180

400

600

1000

1500

2500

100A

150

Minimum

40

60

100

150

250

500

Maximum

280

600

1000

1500

2200

3800

200

Minimum

40

60

120

200

300

600

Maximum

300

650

1200

1500

2500

4100

250

Minimum

50

80

120

200

300

600

Maximum

320

700

1200

1500

2500

4400

300

Minimum

50

80

120

200

300

600

Maximum

350

750

1300

1800

2800

4800

350

Minimum

50

80

120

200

300

600

Maximum

370

800

1300

1800

3000

5000

400

Minimum

50

80

120

200

300

600

Maximum

380

900

1400

2000

3100

5300

450

Minimum

50

80

120

200

300

600

Maximum

390

900

1400

2000

3200

5600

500

Minimum

50

100

120

300

400

800

Maximum

400

1000

1500

2200

3500

5800

550

Minimum

50

100

120

300

400

800

Maximum

420

1000

1500

2200

3600

6000

600

Minimum

50

100

150

300

400

800

Maximum

420

1000

1600

2300

370

6300

650

Minimum

50

100

150

300

400

800

Maximum

450

1100

1600

2300

3800

6500

700

Minimum

50

100

150

300

500

1000

Maximum

460

1100

1700

2400

3900

6700

750

Minimum

50

100

150

300

500

1000

Maximum

500

1100

1750

2400

4000

7000

800

Minimum

60

100

150

300

500

1000

Maximum

500

1200

1800

2500

4200

7100

850

Minimum

60

100

150

300

500

1000

Maximum

520

1200

1850

2500

4300

7200

900

Minimum

60

100

150

300

500

1000

Maximum

520

1200

1900

2600

4400

7400

950

Minimum

70

100

150

300

500

1000

Maximum

530

1200

1950

2600

4500

7600

1000

Minimum

70

120

200

400

600

1000

Maximum

550

1300

2000

3000

4600

7800

1050

Minimum

70

120

200

400

600

1000

Maximum

550

1300

2050

3000

4700

8000

1100

Minimum

80

120

200

400

600

1000

Maximum

560

1300

2100

3100

4800

8100

1150

Minimum

80

120

200

400

600

1000

Maximum

560

1300

2100

3100

4900

8300

1200

Minimum

80

120

200

400

600

1000

Maximum

580

1400

2200

3200

5000

8400

1250

Minimum

80

120

200

400

600

1000

Maximum

600

1400

2200

3200

5000

8600

1300

Minimum

80

120

200

400

800

1200

Maximum

600

1500

2300

3300

5200

8800

1350

Minimum

80

120

200

400

800

1200

Maximum

620

1500

2300

3300

5200

8900

1400

Minimum

80

150

300

600

800

1200

Maximum

630

1500

2300

3500

5300

9100

1450

Minimum

90

150

300

600

800

1200

Maximum

640

1500

2300

3500

5400

9200

1500

Minimum

90

150

300

600

800

1200

Maximum

650

1600

2500

3600

5500

9300

1550

Minimum

90

150

300

600

800

1200

Maximum

660

1600

2500

3600

5600

9500

1600

Minimum

90

150

300

600

800

1200

Maximum

670

1600

2500

3800

5700

9600

1650

Minimum

90

150

300

600

800

1200

Maximum

680

1600

2500

3800

5700

9800

1700

Minimum

90

150

300

600

800

1200

Maximum

690

1800

2600

3800

5800

9900

1750

Minimum

90

150

300

600

800

1200

Maximum

700

1800

2600

3800

5900

10000

1800

Minimum

100

150

300

600

800

1200

Maximum

710

1800

2700

3900

6000

11000

Please refer to a 9-page report.

RYUTAI KOGYO CO.,LTD.

816

ORIFICE FLOWMETER RDP-100 RDP-505

Flowrate range Saturated steam

WEB PRODUCTS GUIDE

RDP-100

WPG-RDP-E02

RDP-505

Pressure

Maximum flowrange

kPaG

kg/h

125A

150A

200A

250A

300A

100

Minimum

400

600

1000

2000

2500

3000

Maximum

4000

5200

9000

14000

22000

30000

Meter Size
350A

150

Minimum

700

1000

1500

3000

4000

5000

Maximum

5000

8200

15000

22000

27000

38000

200

Minimum

700

1500

2000

3500

5000

7000

Maximum

7000

9000

16000

25000

35000

50000

250

Minimum

700

1500

2000

3500

5000

7000

Maximum

7000

9500

17000

26000

38000

54000

300

Minimum

700

1500

2000

3500

5000

7000

Maximum

8000

11000

18000

28000

40000

58000

350

Minimum

700

1500

2000

3500

5000

7000

Maximum

8000

11000

19000

30000

43000

62000

400

Minimum

700

1500

2500

3500

5000

7000

450

Maximum
Minimum

8500
900

12000
1500

21000
2500

31000
3500

45000
5000

64000
7000

Maximum

9000

12000

21000

33000

48000

65500

500
-

Minimum
Maximum

900
10000

2000
13000

3000
23000

4000
34000

5000
50000

7000
70000

550

Minimum

900

2000

3000

4000

5000

7000

Maximum

10000

13000

24000

35000

51000

72500

600

Minimum

1000

2000

3000

4000

5000

7000

Maximum

10500

14000

25000

37000

53000

75000

650
-

Minimum
Maximum

1000
10500

2000
14000

3000
25000

4000
38000

5000
55000

7000
77500

700

Minimum

1500

2000

3000

4000

7000

8000

Maximum

11000

15000

26000

39000

57000

80000

750

Minimum

1500

2000

3000

4000

7000

8000

Maximum

11000

15000

27000

41000

57500

82500

800

Minimum

1500

2000

3000

4000

7000

10000

Maximum

12000

16000

28000

42000

60000

85000

850

Minimum

1500

2000

3000

4000

7000

10000

Maximum

12000

16000

28000

43000

61500

87000

900

Minimum

1500

2000

3000

4000

7000

10000

Maximum

12000

16000

29000

44000

63000

89000

950

Minimum

1500

2000

3000

4000

7000

10000

Maximum

12000

17000

29000

45000

64500

91000

1000

Minimum

1500

2000

3000

5000

7000

10000

Maximum

13000

17000

30000

46000

66000

93000

1050

Minimum

1500

2000

3000

5000

7000

10000

Maximum

13000

18000

31000

47000

67500

95000

1100

Minimum

1500

2000

3000

5000

8000

10000

Maximum

13000

18000

32000

48000

69000

97000

1150

Minimum

1500

2000

3000

6000

8000

10000

Maximum

13000

18000

32000

49000

70000

98500

1200

Minimum

1500

2000

3000

5000

8000

10000

Maximum

14000

19000

33000

50000

72000

100000

1250

Minimum

1500

2000

3000

6000

8000

10000

Maximum

14000

19000

33000

51000

73500

100000

1300

Minimum

2000

2500

4000

7000

10000

12000

Maximum

14500

19000

34000

52000

75000

105000

1350

Minimum

2000

2500

4000

7000

10000

12000

Maximum

14500

20000

34000

52000

76000

105000

1400

Minimum

2000

2500

4000

7000

10000

12000

Maximu

15000

20000

35000

53000

77000

108000

1450

Minimum

2000

2500

4000

7000

10000

12000

Maximum

15000

20000

35000

54000

78500

108000

1500

Minimum

2000

2500

4000

7000

10000

12000

Maximum

15500

21000

36000

55000

80000

110000

1550

Minimum

2000

2500

4000

7000

10000

12000

Maximum

15500

21000

36000

56000

81000

110000

1600

Minimum

2000

2500

4000

7000

10000

12000

Maximum

16000

21000

37000

57000

82000

115000

1650

Minimum

2000

2500

4000

7000

10000

12000

Maximum

16000

21000

37000

57000

83000

115000

1700

Minimum

2000

2500

4000

7000

10000

12000

Maximum

16500

22000

38000

58000

84000

118000

1750

Minimum

2000

2500

4000

7000

10000

12000

Maximum

16500

22000

38000

59000

85500

118000

1800

Minimum

2000

2500

4000

7000

10000

12000

Maximum

17000

22000

39000

60000

87000

120000

The report 1. upper row serves as maximum of the minimum measuring range, and the lower berth serves as maximum of the maximum measuring range.
Pressure is a gauge pressure. kPa (G) It expresses.
Example 150A, saturated steam, pressure It becomes the 0-2000kg [/h ] minimum range, the maximum range 0 - 13000 kg/h at the time of 500kPa(G).
Report 2. Pressure In the case of 100kPa(G) ..... Design Diff.press.25kPa, measurement range 1:7
Pressure In the case of 150kPa(G) ..... Design Diff.press.35kPa, measurement range 1:8
Pressure In the case of 200kPa(G) ..... Design Diff.press.50kPa, measurement range 1:10 or more

RYUTAI KOGYO CO.,LTD.

916

ORIFICE FLOWMETER RDP-100 RDP-505

Flowrate range AIR

RDP-100

WEB PRODUCTS GUIDE

WPG-RDP-E02

RDP-505

Pressure

Maximum flowrange

kPaG

m3/h(ntp)

25A

40A

50A

65A

80A

50

Minimum

20

30

40

60

80

120

Maximum

150

300

400

600

1000

2000

Meter Size
100A

100

Minimum

30

40

50

100

120

200

Maximum

200

420

700

1000

1600

2700

150

Minimum

40

50

65

120

150

300

Maximum

300

700

1100

1600

2600

4300

200

Minimum

50

60

80

150

200

400

Maximum

330

750

1200

2000

2800

4700

250

Minimum

50

60

80

150

200

400

Maximum

350

800

1300

2000

3000

5100

300

Minimum

50

80

100

150

300

500

Maximum

380

850

1400

2200

3200

5500

350

Minimum

50

80

100

200

300

500

Maximum

400

910

1500

2300

3400

5800

400

Minimum

50

80

120

200

300

500

Maximum

420

970

1600

2400

3600

6100

450

Minimum

50

80

120

200

300

500

Maximum

450

1000

1650

2450

3800

6400

500

Minimum

60

100

120

200

300

500

Maximum

470

1050

1700

2500

4000

6700

550

Minimum

60

100

120

230

300

500

Maximum

480

1100

1800

2600

4200

7000

600

Minimum

60

100

150

230

400

700

Maximum

520

1150

1850

2700

4300

7300

650

Minimum

60

100

150

230

400

700

Maximum

530

1200

1900

2800

4500

7600

700

Minimum

60

120

150

230

400

700

Maximum

540

1250

2000

2900

4600

7800

750

Minimum

60

120

150

230

400

700

Maximum

550

1280

2050

3000

4800

8100

800

Minimum

60

120

150

230

400

700

Maximum

580

1300

2100

3100

4900

8300

850

Minimum

60

120

180

230

400

700

Maximum

590

1350

2200

3200

5000

8500

900

Minimum

60

120

180

230

400

700

Maximum

600

1400

2200

3300

5200

8700

950

Minimum

60

120

180

230

400

700

Maximum

620

1450

2300

3400

5300

9000

1000

Minimum

80

150

180

250

400

700

Maximum

630

1500

2350

3500

5400

9200

1050

Minimum

80

150

180

250

500

1000

Maximum

650

1550

2400

3600

5500

9400

1100

Minimum

80

150

200

250

500

1000

Maximum

660

1600

2450

3700

5650

9600

1150

Minimum

80

150

200

250

500

1000

Maximum

670

1650

2500

3800

5800

9800

1200

Minimum

80

150

200

250

500

1000

Maximum

690

1650

2550

3900

5900

10000

1250

Minimum

80

150

200

250

500

1000

Maximum

700

1650

2600

4000

6000

10100

1300

Minimum

80

150

200

250

500

1000

Maximum

720

1700

2650

4100

6100

10300

1350

Minimum

80

150

200

250

500

1000

Maximum

730

1700

2700

4200

6200

10500

1400

Minimum

80

150

200

250

500

1000

Maximum

740

1700

2750

4300

6300

10700

1450

Minimum

80

150

200

250

500

1000

Maximum

750

1700

2800

4400

6500

10900

1500

Minimum

80

150

200

250

500

1000

Maximum

770

1750

2850

4500

6600

11000

The report 1. upper row serves as maximum of the minimum measuring range, and the lower berth serves as maximum of the maximum measuring range.
Pressure is a gauge pressure. kPa (G) It expresses.
Example 100A, AIR , pressure It becomes the 0-500 m3/h(ntp) minimum range, the maximum range 0 - 6700 m3/h(ntp) at the time of 500kPa(G).
Report 2. Pressure In the case of 100kPa(G) ..... Design Diff.press.25kPa, measurement range 1:7
Pressure In the case of 150kPa(G) ..... Design Diff.press.35kPa, measurement range 1:8
Pressure In the case of 200kPa(G) ..... Design Diff.press.50kPa, measurement range 1:10 or more
Report 3. It is in 20 degrees C in AIR, and the operation state of 1atm (0kPaG). It expresses with flowrate (ntp) in the volume of 0 degree C and 1atm.

RYUTAI KOGYO CO.,LTD.

1016

ORIFICE FLOWMETER RDP-100 RDP-505

Flowrate range AIR

RDP-100

WEB PRODUCTS GUIDE

WPG-RDP-E02

RDP-505

Pressure

Maximum
flowrange

kPaG

m /h(ntp)

125A

150A

200A

250A

300A

50

Minimum

200

300

500

800

1200

1800

Maximum

2500

3000

5000

8000

12000

20000

Meter Size

350A

100

Minimum

300

500

800

1200

1800

2500

Maximum

3500

5800

10000

16000

28000

32000

150

Minimum

500

600

1000

1500

2500

3000

Maximum

5000

9300

14000

21000

35000

40000

200

Minimum

600

800

1300

2000

3000

3500

Maximum

6500

10200

18000

28000

39500

49000

250

Minimum

600

800

1300

2000

3000

3500

Maximum

7000

11000

20000

30000

43000

53000

300

Minimum

800

1000

1500

2300

3500

5000

Maximum

7500

12000

21000

32000

46000

57000

350

Minimum

800

1000

1500

2300

3500

5000

Maximum

8000

12500

22000

34000

49000

60000

400

Minimum

800

1000

1500

2300

3500

5000

Maximum

8500

13500

24000

36000

52000

64000

450

Minimum

800

1000

1500

2300

3500

5000

Maximum

9000

14000

25000

38000

54000

67000

500

Minimum

800

1000

1500

2300

3500

5000

Maximum

10000

15000

26000

40000

57000

70000

550

Minimum

800

1000

1500

2300

3500

5000

Maximum

11000

15500

27000

41000

59000

73000

600

Minimum

1000

1500

2000

2500

4000

7000

Maximum

12000

16000

28000

43000

61000

76000

650

Minimum

1000

1500

2000

2500

4000

7000

Maximum

12500

16500

29000

45000

63500

79000

700

Minimum

1000

1500

2000

2500

4000

7000

Maximum

13000

17000

30000

46000

65000

82000

750

Minimum

1000

1500

2000

2500

4000

7000

Maximum

13500

17500

31000

47000

67500

84000

800

Minimum

1000

1500

2000

2500

4000

7000

Maximum

14000

18000

31500

48500

70000

86000

850

Minimum

1000

1500

2000

2500

4000

7000

Maximum

14500

18500

32500

49500

71000

89000

900

Minimum

1000

1500

2000

2500

4000

7000

Maximum

15000

19000

33500

51000

73000

91000

950

Minimum

1000

1500

2000

2500

4000

7000

Maximum

15000

19500

34000

53000

75000

93000

1000

Minimum

1000

1500

2000

3000

5000

10000

Maximum

15500

20000

35000

54000

77000

96000

1050

Minimum

1200

1700

2300

3500

7000

10000

Maximum

16000

20500

36000

55000

79000

98000

1100

Minimum

1200

1700

2300

3500

7000

10000

Maximum

16500

21000

36500

56000

81000

100000

1150

Minimu

1200

1700

2300

3500

7000

10000

Maximum

16500

21500

37000

58000

82000

102000

1200

Minimum

1200

1700

2300

3500

7000

10000

Maximum

17000

22000

38000

58500

84000

104000

1250

Minimum

1200

1700

2300

3500

7000

10000

Maximum

17000

22000

39000

59500

85000

106000

1300

Minimum

1500

1700

2300

3500

7000

10000

Maximum

17500

22500

39500

60500

87000

108000

1350

Minimum

1500

2000

2500

4000

8000

13000

Maximum

17500

23000

40000

61500

89000

110000

1400

Minimum

1500

2000

2500

4000

8000

13000

Maximum

18000

23500

41000

63000

90000

112000

1450

Minimum

1500

2000

2500

4000

8000

13000

Maximum

18000

24000

41500

64000

92000

114000

1500

Minimum

1500

2000

2500

4000

8000

13000

Maximum

18500

24000

42000

65000

93000

116000

Flowrate range H2O WATER

RDP-100

RDP-505

Pressure

Maximum
flowrange

kPaG

m3/h

25A

40A

50A

65A

80A

100A

125A

150A

200A

250A

300A

Minimum

1.5

2.5

3.5

15

20

35

50

60

Maximum

13

22

35

50

90

135

195

330

520

750

900

100
150
200 or more

Meter Size
350A

Minimum

1.5

12

20

30

50

70

100

Maximum

16

26

44

63

105

164

230

400

610

885

1090

Minimum

1.5

3.5

12

20

30

50

70

100

Maximum

19

31

53

75

130

196

275

478

736

1057

1314

RYUTAI KOGYO CO.,LTD.

1116

ORIFICE FLOWMETER RDP-100 RDP-505

PRESSURE LOSS

WEB PRODUCTS GUIDE

WPG-RDP-E02

PDP-100 RDP-505

"Standard design diff. press." although I design RDP-100/RDP-505 by arbitrary diff. press., in case there is
no specification is. It is supposed ", with steam and a liquid, they are 50kPa", and ", at gas, they are 25kPa."
8 pages - 11 pages Flowrange is calculated by "standard maximum diff.press."
In appointed Maximum diff.press., it differs from flowrate range of a table.
When you specify Maximum diff.press., be careful.
Since the value of beta(iris diaphragm diameter ratio) d/D can be found with Maximu flowrange, pressure,
and temperature, for details, please ask it to our company.

RYUTAI KOGYO CO.,LTD.

1216

ORIFICE FLOWMETER RDP-100 RDP-505

PRESSURE LOSS

WEB PRODUCTS GUIDE

WPG-RDP-E02

PDP-100 RDP-505

"Standard design diff. press." although I design RDP-100/RDP-505 by arbitrary diff. press., in case there is
no specification is. It is supposed ", with steam and a liquid, they are 50kPa", and ", at gas, they are 25kPa."
8 pages - 11 pages Flowrange is calculated by "standard maximum diff.press."
In appointed Maximum diff.press., it differs from flowrate range of a table.
When you specify Maximum diff.press., be careful.
Since the value of beta(iris diaphragm diameter ratio) d/D can be found with Maximu flowrange, pressure,
and temperature, for details, please ask it to our company.

RYUTAI KOGYO CO.,LTD.

1316

ORIFICE FLOWMETER RDP-100 RDP-505

WEB PRODUCTS GUIDE

Compensation Calculation For PDP-100 RDP-505

WPG-RDP-E02

(Engineering data)

In case of Gas measurement Volume flow rate


The pressure change from a design condition and temperature change produces indication error.
Density change of the gas from a design condition produces a indication error.
True flow rate = Indicate flow rate Compensation coefficient

Q1 : True flow rate

( Volume flow rate m3/h(ntp) , l/h(ntp) , m3/min(ntp) , l/min(ntp)

Q0 : Indicate flow rate

( Volume flow rate m /h(ntp) , l/h(ntp) , m /min(ntp) , l/min(ntp) )

: Actual Gas

( Density of an actual gas kg/m3 (ntp) at 1atm , 0

0 : Design Gas

( Density of an design gas kg/m3 (ntp) at 1atm , 0

P1 : True pressure

( True operating pressure kPa(G)

P0 : Design pressure

( Design pressure

T1 : True temperature

( True operating temperature

T0 : Design temperature

( Design temperature

kPa(G)

at gauge
at gauge

Compensation Calculation Example 1

Original design condition of flowmeter


Fluid name : AIR

Design density : 1.293 kg/m3 (ntp) Design pressure : 500 kPa(G) Design temperature : 20

True process condition


Fluid name : N2

Density : 1.250 kg/m3 (ntp)

True pressure : 400 kPa(G)

True temperature : 25

Indication of flowmeter : 2000 m /h(ntp)


3

True flow rate of N2 = 1841.6

RYUTAI KOGYO CO.,LTD.

m3/h(ntp)

1416

ORIFICE FLOWMETER RDP-100 RDP-505

WEB PRODUCTS GUIDE

Compensation Calculation For PDP-100 RDP-505

WPG-RDP-E02

(Engineering data)

In case of STEAM measurement Mass flow rate

The pressure change from a design condition and temperature change produces indication error.
Density change of the gas from a design condition produces a indication error.
True flow rate = Indicate flow rate Compensation coefficient

W1 : True flow rate

( Mass flow rate kg/h , kg/min , t/h

W0 : Indicate flow rate

( Mass flow rate kg/h , kg/min , t/h

: Actual steam

( Density of steam kg/m3

0 : Design steam

( Density of steam kg/m

Compensation Calculation Example 2

Original design condition of flowmeter


Fluid name : steam Design density : 3.173 kg/m3 Design pressure : 500 kPa(G)
True process condition
Fluid name : steam

Density : 2.172 kg/m3

Indication of flowmeter : 6346

True pressure : 300 kPa(G)

kg/h

True flow rate of STEAM = 5250

RYUTAI KOGYO CO.,LTD.

kg/h

1516

ORIFICE FLOWMETER RDP-100 RDP-505

WEB PRODUCTS GUIDE

WPG-RDP-E02

Cautions when using a product


The product to guide is manufactured for the purpose of using it for the equipment of general industrial
apparatus. It was not directly manufactured by the human life for the purpose of using it for the
equipment used in a situation which is concerned.
When there is a plan to use this product as those uses, please contact a marketing department office
in advance.
The product to guide is manufactured by severe quality control.
When failure of parts etc. takes place, please construct the special consideration for building a safe system
about employment of a system, maintenance, and management on the occasion of the use to a facility
which is concerned with a human life, or the facility with which serious influence is expected.
Since it is needed in a power source in use of this product, an electrical work, installation construction, etc.
are required.
Please use correctly for often reading the handling description of relation, before use of a
product.

Use limitation
It was not manufactured in order to apply to the system of which the safety to affect the
following human lives is required directly.
The protection system aiming at safe maintenance of a human life.
The medical C-system in connection with human life maintenance.

Qualification
About the following damage, our company shall be exempted from obligation.
Damage produced by intentionally [ of a fire, an earthquake, the act by the third person, other accidents,
and a user ] or negligence, misuse, and other use under unusual conditions.
Damage produced since use of the product to guide is impossible (damage by loss of enterprise profits,
and enterprise discontinuation).

The inquiry about a product should inform of the following specification.


A Model sign, an size, the flowrate range, a fluid name, density, viscosity, temperature, pressure,
the quality of the material, the quantity.

Written contents may be changed that there is no preliminary announcement because of product

Head office

Kyodo Bldg. (Shin-chuo)4-9 Nihonbashi-Honcho 1-Chome


Chuo-ku Tokyo 103-0023 Japan
el. 81--3242-0961
ax. 81-3-3245-1980

Osaka office

Dohkita Bldg. 2-3-2 Dojima Kita-ku Osaka 530-0003


Japan
el. 81-6-6344-9458
ax. 81-6-6344-5765

Nagoya office

Dai-Ni Kurokawa Terminal Heights 401 2-12-7 Tabata Kita-ku


Nagoya-Shi 462-0843 Japan
el. 81-52-910-6401
ax. 81-52-910-6400
http://www.ryutai.co.jp/

RYUTAI KOGYO CO.,LTD.

1616

S-ar putea să vă placă și