Sunteți pe pagina 1din 8

40SS Series

High Pressure Stainless Steel Filter

40SS Series
Applications
Together we can the environment. Preserve Minimize waste and promote energy efficiency. worldwide Achieve filtration solutions. Build global confidence. ne new limits. Redefi Forge ahead with advanced technology. contamination under Keep control. Reduce maintenance costs. total system reliability. Enhance Focus on customer satisfaction. optimum potential. Reach Drill to greater depths. engineer your success. Parker engineers have developed a new stainless steel medium pressure filter for higher flow applications in a cost effective patented design. This patented element interface requires an element to be installed in order to install the filter cover, guaranteeing full-time system protection. The interface also locks the element to the cover assembly, easing element removal during maintenance cycles. The new 3,000 psi 40SS series filter is ideally suited for applications in water and caustic solutions, or where harsh environmental conditions exist. Typical Applications Mining Oil & Gas Power Gen Marine Rening Food & Beverage Primary Metals Pulp & Paper Refuse

40SS Series
Specications
Pressure Ratings: Maximum Allowable Operating Pressure (MAOP): 3,000 psi (206 bar) Rated Fatigue Pressure: 3,000 psi (206 bar) Design Safety Factor: 3:1 Operating Temperatures: Buna: -40F (-40C) to 225F (107C) Fluorocarbon: -15F (-26C) to 275F (135C)
ELEMENT ACCESS COVER ELEMENT REMOVAL CLEARANCE 20.00 TORQUE 120 FT.-LBS. (Anti-Sieze Compound Required on Threads)

Element Collapsing Rating: Standard: 300 psi (21 bar) High Collapse: 2,000 psi (138 bar) Materials: Head: Stainless Steel 304/304L Bowl: Stainless Steel 304/304L/17-4 Cover Assembly: 17-4 Stainless Steel Indicator: 300 Series Stainless Steel with Thermoplastic connectors Weight (approximate): 65 lbs.

1.000 HEX OUTLET

SAE-4 VENT PLUG TORQUE 15-20 FT.-LBS.

4.97

5.25 PORT TO PORT

R3.00 INLET

TOP VIEW
22.88 .15 1.93 3.850 VISUAL INDICATOR RIGHT SIDE SHOWN (See Ordering Model Code Options) TORQUE 30-35 FT.-LBS. INDICATOR PORT (PLUGGED) TORQUE 30-35 FT.-LBS.

INLET

1.63

1.64 .33 3.250

1/2-13 UNC - 2B 4 PLCS

.75

OUTLET

BOTTOM VIEW

Drawings are for reference only. Contact factory for current version.

Assembly Note: Anti-Sieze Compound Required on all Threads 2 INLET AND OUTLET PORTS IN-LINE (See Ordering Model Code Options) 1.72

40SS Series
Features
SAE-4 VENT PLUG SLIP THREAD COVER

Patented Slip Thread Cover Requires the Element to be Present for Cover Installation

Bowl-Up Configuration for Ease of Element Maintenance Patented Element Interlock Design for Element Removal with Cover Stainless Steel Construction Large 2 Porting for Increase Flow Capacity Stainless Steel Visual and Visual/ Electrical Indicator Options Integral Mounting Holes for Installation Flexibility

VISUAL INDICATOR

VISUAL INDICATOR PLUG

Drawings are for reference only. Contact factory for current version.

40SS Series
Parts List
Parts List Ref. Quantity Part Number
1 1 2 3 4 4 5 6 7 8 9 10 1 1 1 1 1 1 1 1 1 1 1 1 942444 942931 942735 942446 942453 943079 942508 929007 942543 V92238 V92240 942736

7 8

11 Description

40SS Head - 2 BSPP 40SS Head - SAE32 40SS-2 Bowl 40SS Slip Thread Cover M2 Stainless Steel Indicator E2 Stainless Steel Indicator Stainless Steel Indicator Plug Stainless Steel SAE-4 (Viton) Plug 40SS Slip Thread Cover Back-Up Ring 40SS Slip Thread Cover Viton O-Ring 40SS Bowl Viton O-Ring 40SS Bowl Back-Up Ring

2 9 10 1
Not Shown

4 Ref. 11 11 11 11 11 11 Ref. 11 11 Replacement Elements Part Number Standard Element 942914Q Microglass, 2 micron 942915Q Microglass, 5 micron 942916Q Microglass, 10 micron 942917Q Microglass, 20 micron 942920 Wire Mesh, 25 micron 942921 Wire Mesh, 74 micron Part Number High Collapse Element 942918Q Microglass, 10 micron 942919Q Microglass, 20 micron

40SS Series
Element Performance
Beta Rating 10000

Efciency

Efficiency %

PSID 100

Capacity
2Q 5Q

BAR

2Q 1000

5Q 10Q 99.9 80

10Q 20Q

200 100

20Q

99.5 99.0

60

3 40 20 95.0 2 20 1 2 50.0 0 0.0 4.0 8.0 12.0 16.0 20.0 0 20 40 60 80 100 120 140 Micron Size (c) Capacity grams 0

Results typical from Multi-pass tests run per test standard ISO 16889 @ 50 gpm to 100 psid terminal - 10 mg/L BUGL

Flow vs Pressure Loss


LPM 0 25.0 100 200 300 400 500 25.0 150SUS (32 cSt) 2Q 20.0 5Q 1.5 20.0 0 100 200 LPM 300 400 500

150 SUS (32 cSt) Empty Housing 1.5

10Q 15.0 PSID 20Q PSID 1.0 BAR 15.0


tS or ize

1.0 BAR 0.5 0.0 0 30 60 GPM 90 120 150

10.0 25W 5.0 74W 0.0 0 30 60 GPM 90 120 150 0.0 0.5

10.0
N 2"

P al in om

5.0

0.0

40SS Series
Service & Maintenance Instructions
1 2
Stop system and vent pressure. Unthread cover with element assembly attached and remove from housing. On the cover assembly, rotate the threaded collar until the collar slots are aligned with the tabs on the element. Pull element to remove from the cover assembly. On the cover assembly, align slots on threaded collar with slots on inner cover. Align tabs on the new element with the aligned slots on the cover assembly. Push the cover assembly onto element. Rotate the threaded collar on the cover assembly so the tabs on the element are covered. Lubricate seals with system fluid. Apply nuclear grade nickel antiseize lubricant, similar to McMaster-Carr P/N 1027K32 to the cover threads. Lower cover / element assembly into housing and torque cover to 120 ft-lbs.

4 5

7 8

9 10

11

40SS Series
How to Order
Select the desired symbol (in the correct position) to construct a model code. Example:
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8

40SS

10Q

B
BOX 4: Seals Symbol Description B V E2 Nitrile (NBR)

M2

S32

BOX 1: Filter Series1, 4 Symbol Description 40SS High Pressure Filter, 100 GPM BOX 2: Element Length Symbol Description 2 Double Length

BOX 7: Ports5 Symbol Description S32 G32 SAE-32 (2- - 12 UN-2B) 2 BSPP (ISO 228)

Fluorocarbon (FKM) Ethylene Propylene (EPR)

BOX 5: Indicator Symbol Description M2 E22 Visual Electrical

BOX 8: Options Symbol Description 1 2 With Bypass No Bypass

BOX 3: Media Code Symbol Description Standard Element (Bypass only) 02Q 05Q 10Q 20Q 25W 74W Microglass III, 2 micron Microglass III, 5 micron Microglass III, 10 micron Microglass III, 20 micron Wire Mesh, 25 micron Wire Mesh, 74 micron

Notes:

BOX 6: Bypass/Indicator3 Symbol Pressure Setting K 50 PSI (3.5 bar)

1. The filter includes the element you select already installed. 2. Consult factory for current availability. 3. When 2 is selected in box 8, indicator setting is 50 psid. 4. For D.I water applications, consult factory. 5. Consult factory for additional options.

High Collapse (No Bypass only) 10QH 20QH Microglass III, 10 micron Microglass III, 20 micron

2013 Parker Hannifin Corporation

Parker Hannifin Corporation Hydraulic Filter Division 16810 Fulton County Road #2 Metamora, OH 43540 phone 800 253 1258 fax 419 644 6205 email hydraulicfilter@parker.com www.parker.com

S-ar putea să vă placă și