Suited for mobile operation with a notebook Calibration parameter lodged in sensor Calibration control actuation by software Integrated speed/angle measurement Virtually no influence of the bearing friction on the measuring signal Power computation by software High torsional stiffness Simple handling and assembly
This sensor has a contactless and digital signal transmission from rotor to stator, which means no signal falsification and maintenance-free.
080713i_DR-3000_en.doc 1/4
LORENZ MESSTECHNIK Gm bH
Specifications
Nominal Torque [Nm] Article Number
Drive side 30000 30000 30000 30000 30000 30000 30000 20000 20000 20000 20000 15000 15000 15000 12000 12000 1.8E+01 1.8E+01 9.4E+01 9.4E+01 3.7E+02 7.7E+02 8.8E+02 5.1E+03 5.1E+03 9.6E+03 9.6E+03 8.9E+04 1.3E+05 1.7E+05 6.3E+05 9.6E+05 9.2E-06 9.2E-06 9.2E-06 9.2E-06 9.2E-06 9.2E-06 9.3E-06 1.2E-04 1.2E-04 1.2E-04 1.2E-04 5.4E-04 5.4E-04 6.4E-04 5.7E-03 5.8E-03
Test side 2.5E-07 2.5E-07 2.5E-07 2.5E-07 2.5E-07 2.6E-07 3.4E-07 6.8E-06 6.8E-06 7.4E-06 7.4E-06 4.4E-04 4.4E-04 5.3E-04 5.1E-03 5.2E-03 40 40 120 120 250 450 550 1200 1200 2500 2500 5000 6800 10000 17000 32000 0.5 0.5 1.5 1.5 3.5 8 10 22 22 70 70 140 200 450 600 1500
114357 114358 111231 111177 111232 111233 111234 111235 111236 111114 111237 111238 110554 111240 112801 112803
Accuracy class torque Speed resolution Speed accuracy Angle of rotation resolution Relative spread Feed-in from USB Current consumption Output signal torque Output signal speed / angle of rotation Input calibration control signal actuation Sample rate Reference temperature Nominal temperature range Service temperature range Storage temperature range Temperature coefficient of characteristic value Temperature coefficient of zero signal Service torque (static) Limit torque (static) Ultimate torque (static) Bandwidth (DIN 50 100) Level of protection (DIN EN 60529) Electrical connection
DR-3000 0.1 1 1 0.25 0.02 46 max. 250 25,000 32,511 per Software 2.5 23 5 ... 45 0 ... 60 -10 ... 70 0.01 0.02 150 200 300 70 (peak - peak) IP50 PX0446 IP68 B Mini USB, incl. 3 m connection cable to PC
1 2
080713i_DR-3000_en.doc 2/4
Springrate [Nm/rad]
LORENZ MESSTECHNIK Gm bH
Options/ Accessories
Article-no 101695 Description Accuracy class Keys according DIN 6885 % f. s.
0.05 on request
Option Calibrations
Article-no 400676 400664 400961 400700 400688 Description Linearity diagram Linearity diagram Proprietary calibration Proprietary calibration Proprietary calibration DAkkS- Calibration Steps 25% 10% 3 5 8 Norm Factory standard VDI/VDE 2646 on request
Dimensions
USB - Buchse USB - female plug 30 A 60
34
B C F C
G H u0,05
O D g6
O O H7 (2x)
P (4x)
E X
K L u0,05 M
Ansicht X View X
All dimensions in mm
Dimensions [mm]
A 110 B 19 C 17 D 8 10 18 32 42 70 E 71 71 90 120 120 144 F 63 63 88 118 118 163 G 40 H 20 I 35 J 30 K 12 12 15 20 20 25 L 35.5 M 59 O 4 4 6 8 8 12 P M4 M4 M6 M8 M8 M12 T 8 8 8 14 14 20
110 19 17 163 36.5 35 234 56.5 55 234 56.5 55 372 114 110
080713i_DR-3000_en.doc 3/4
O D g6
LORENZ MESSTECHNIK Gm bH
Configuration and Evaluation Software
DR-USB-VS
Convenient configuration and evaluation software Graphic presentation of torque/ speed/ power or torque/ angle of rotation Automatic scaling of y-axis Simultaneous storage of up to 3 physical values Automatic storage function of the measured values as CSV- or BMP-File
DESCRIPTION
Configuration and evaluation software for easy analysis and graphic presentation on a PC. The software allows direct read in of measured data into a text file in CSVFormat through the USB-Port of a PC. This enables further analyses with a commercially available spreadsheet program at any time.
SPECIFICATIONS
Type Interface Protocol System requirements DR-USB-VS USB Lorenz standard protocol ex Win20003 Single- Core ex 2.0 GHz (without diagram) Dual- Core ex 1.8 GHz (with diagram)
Conversion in physical values Simultaneous measuring Graphic presentation of a physical value Automatic or manual storage in a CSV and BMP file Mathematical computation of the mechanical power Calibration function Resettable minimum value memory for each measured value Resettable maximum value memory for each measured value Variable average determination Tare for each measured value
1 Sensor