Contents:
1.) Basic information to the DDE-Server 2.) Select interface 3.) Set up transmission channel 4.) Activate server 5.) Basic settings 6.) Example of data exchange using MS Excel 7.) Fault messages
category of measured value: *A actual value * I integration value intermediate analysis *D integration value day analysis *M integration value month analysis *Y integration value Year analysis d) If the channel is to be read out then Active=Yes must be set; if Active=No is set then the channel is set up but will not be read out by the PC; this setting has no influence on the channel itself. This means that the internal unit settings are not changed; e) Operate the Save button ! If more than 50 channels are needed then more than one DDE server must be installed on the PC and started, this also means they must drive different COM ports. Here it must be noted that the application name (*.exe) will have to be changed manually so that each server has its individual name. The COM ports have to use different Interrupts.
Example: =dde_serv|server!Channelx Whereby x is the number of the virtual channel that is to be transmitted, e.g. 1...50