HydroCOM Actuator

Actuator components
Valve Valve Housing Housing
Oil Oil inlet inlet Solenoid Solenoid valve valve High High pressure pressure piston piston Oil Oil outlet outlet

Seal Seal Housing Housing


Vent Vent Leakage Leakage oil oil Flare Flare line line Optional: Optional: Seal Seal gas gas Sealing Sealing elements elements Temperature Temperature sensor sensor

Electric Electric Housing Housing


48VDC 48VDC connection connection HydroCOM HydroCOM field field bus bus

Jan_06

HydroCOM Actuator

Valve housing components


Inlet Nozzle: Controls unloader speed Check valve Solenoid valve High pressure piston

Soft touch damper: Reduces closing impact speed of suction valve sealing element

Jan_06

HydroCOM Actuator

Valve housing Solenoid valve


Stroke 0,2mm Switching time 1 ms Voltage 48 V Starting current 14 A Holding current 4,5 A

return spring anchor plate

No power supply: unloaded; provided there is hydraulic pressure

valve seat

control piston

coil

1.4.4

Jan_06

HydroCOM Actuator

Valve housing - High pressure piston

Oil

Conical metallic sealing

Cylinder Oil return from circular groove O-ring High pressure piston

Jan_06

HydroCOM Actuator

Valve housing Check valve


Valve seat

Valve piston

Spring Max. hydraulic pressure in actuator during unloading > hydraulic unit operating pressure => Check valve required

Jan_06

HydroCOM Actuator

Valve housing Inlet Nozzle


Oil

Inlet strainer KY2007 Solex nozzle: specifically engineered for each application. (Dia 0.3 to 1.0 mm)

Solex nozzle

Jan_06

HydroCOM Actuator

Valve housing Soft touch damper


jet nozzle

valve seat Length of throttle piston calculated for each application

return spring

throttle piston

Jan_06

HydroCOM Actuator

Valve housing Soft touch damper


Valve Valve seat seat Jet Jet nozzle nozzle

Throttle piston

ut oi l o
Return spring Stroke of throttle piston

Jan_06

HydroCOM Actuator

Valve housing Solenoid cooling

Jan_06

HydroCOM Actuator

10

Valve housing
Working Oil, Cooling Oil and Oil Leakage
Oil
Please note: Picture shows old actuator version. Design details differ from version 2001.

anchor plate of
solenoid valve

Cooling and leakage oil


Working oil

Jan_06

HydroCOM Actuator

11

Valve housing Recovery and leakage oil


leakage

Oil Recovery System


connected to the hydraulic unit

Leakage oil

Jan_06

HydroCOM Actuator

12

Valve housing Electronic parts


Socket for connection to electric housing

Cable for oil pressure sensor (old design)

Terminals solenoid Cable for temperature sensor

Jan_06

HydroCOM Actuator

13

Valve housing Pressure sensor


(not supplied for new projects since 2001)

Throttle plate to dampen pressure peaks

Pressure sensor

Soldered connections

Jan_06

HydroCOM Actuator

14

Seal housing
dynamic seals static seals guides wiper ring

flare connection

Jan_06

HydroCOM Actuator

15

Seal housing
Gasket between valve & seal housing
latest design: Gasket old design: O-Ring

Jan_06

HydroCOM Actuator

16

Seal housing NACE/toxic applications


Oil Leakage Purge gas (N2) Flare gas to ambient N2 to flare

Jan_06

HydroCOM Actuator

17

Seal housing materials


Version Dynamic seal: O-Ring Glyd-Ring Viton Fluorsilicone Simriz Remark: Turcon is a composite made of Teflon Viton O-rings may have different colors Guides are always PTFE

Viton (FPM) Turcon

Fluorsilicone (FVMQ) Turcon

Simriz (FFKM) Turcon

Static seal: O-Ring Wiper : O-Ring Wiper-Ring Typical

Viton (FPM)

Fluorsilicone (FVMQ)

Simriz (FFKM)

Viton (FPM) Turcon Natural Gas H2,N2,CO2

Fluorsilicone (FVMQ) Turcon Ethylene

Simriz (FFKM) Turcon

H2S, application Ammonia, LDPE,

Jan_06

HydroCOM Actuator

18

Electric housing Connection housing


Terminals for power supply (+, -) and bus cable (A, B, GND) Cable glands for bus cable

Cable gland for power cable

Protective Earth Connections


HydroCOM Actuator 19

Jan_06

Electric housing - Electronics



Current control for operation of solenoid coil Communication with SIM in CIU via data bus Interface for temperature sensor in actuator Real time data processing for valve actuation which is synchronized with top dead centre signal

Jan_06

HydroCOM Actuator

20

Electric housing Bus address / Termination Actuator 4


The rotary switch defines the bus address of the actuator

Bus Address
01 EF 2
34 5

Termination (ON = active)

Connector to valve housing

67

8 9A

Jan_06

Electric housing Bus address / Termination Actuator 2


Termination by RC-Module (to be installed only in the last actuator of a bus line)

Bus Address
1

on picture selected address = 2

Jan_06

B CD

ON

capacitor for balancing the fluctuating current consumption of the solenoid

HydroCOM Actuator

21

JUMPERS FOR BUS ADDRESS HydroCOM 2.0


Address Coding
+5 3 2 1 0 +5 3 2 1 0 +5 3 2 1 0 +5 3 2 1 0

Address Coding
+5 3 2 1 0 +5 3 2 1 0 +5 3 2 1 0 +5 3 2 1 0

ATTENTION: do not use a RC-Module on a HydroCOM 4.0 Electric housing use the internal resistor switch

HydroCOM Actuator

22

Electric housing Temperature sensor

Coax connector

Temperature Sensor

Jan_06

HydroCOM Actuator

23

Ex-Certificates
HydroCOM is certified for ATEX, FM, CSA, Japanese standard:
ATEX US FM CSA Ex II 2G EEx de IIB + H2 T4 AEx de IIB + H2 T4 Class 1, Div. 1, Group B, C, D, T4 Class 1, Div. 1, Group A, B, C, D, T4

Japan

Ex de IIB + H2 T4

Two types types of electric housings: de: flameproof, increased safety (ATEX) d: flameproof (FM Div. 1)

Jan_06

HydroCOM Actuator

24

HydroCOM Actuator Connections


Oil inlet female G1/2 (old version: Parker 16S)

Oil outlet G 3/8 female (old version: M14x1,5) Venting to ambient Leakage oil G 1/8 Flare line G 1/8

ATEX version: 3 x M20x1.5

Jan_06

HydroCOM Actuator

25

HydroCOM Actuator Workshop testing


After assembly

Valve housing:
2 hour leakage test at 150 bar

Valve housing:
High pressure dynamic test at 8000N: Criteria: 10mm travel of high pressure piston must take at least 4s

Electric function test of complete


actuator

8000N
Jan_06 HydroCOM Actuator 26

Spare Actuator Adoption

Following parts must be in accordance with the partlist for the compressor and actuator the spare actuator is intended to be used: - Solex Nozzle (diameter) - Soft touch damper: length of throttle piston - Seal housing design / sealing materials - Is integrated oil pressure sensor required? - Correct bus address - Termination yes/no (must be set for last actuator on the bus)

Jan_06

HydroCOM Actuator

27