Sunteți pe pagina 1din 4

Installation and Setup Instructions

FAS2220/FAS2240-2 System

Prepare for installation


1

Find in the box:


ACCESSORY TRAY

USB ash drive


Contains software and conguration worksheet

Conguration worksheet

Starter network, storage, and 10 GbE cables

Power cables

Serial cable not needed for this conguration

You need to provide:

Rack space
The FAS2220/2240-2 system requires 2U of rack space as well as power and network connectivity

Screwdriver
For securing hardware into your racks

Additional network cables


For connecting your storage to your network switch and Microsoft Windows client

Microsoft Windows client


Runs the software to congure your storage system

HELPFUL LINKS ON PAGE 4

Install hardware
FRONT VIEW OF SYSTEM
Power LED Attention LED

2
FAS2240-2

Shelf ID display Bezel


Console port (Setting: 9600 N-8-1) Remote/Node Management port (wrench icon)

BACK VIEW OF SYSTEM


NVMEM LED PCM Attention LED
SAS ports (2)
e1a
ACT LNK

e1b
ACT LNK

A
One or two controller modules

Optional 10 GbE card

A
A

BB
1
1

Gigabit Ethernet ports (4) ACP port (locked wrench icon)

2 1

2
Power supply LEDs

Install system
Rack the system.
- Rail kit: follow instructions in rail kit. - System cabinet: install in system cabinet.

CAUTION

LIFTING HAZARD

Place the bezel over the front of the system.

25 kg (55 lbs.)

Cable controller (7-Mode) (Choose option A or B below)


A 10/100/1000
1
Attach cable management arms.
Network cables
BACK VIEW OF FAS2220/2240-2 SYSTEM
1
LNK LNK
e0a e0c

B 10 GbE
1
LNK LNK

Attach cable management arms.


e0a e0c

BACK VIEW OF FAS2220/2240-2 SYSTEM


1
e1a e1b
ACT LNK ACT LNK
LNK LNK

0b

0a
e0b e0d

0b

0a

10 GbE cables
e0b e0d

0b

0a

Cable port e0a to the network switch.


NOTE: Port e0a is required; other ports are available if needed.

AC

AC

Cable port e1a to data switch.


Network cables

AC

4 2

2 3
1 3 5 7 9 11 13 15

3 4

Cable the wrench port to the network switch. Strap the cables to the cable management arms.

11

13

15

1000/100/10M LNK / 1000/100/10M LNK /

10

12

14

16

10

12

14

16

NETWORK SWITCH

Cable the wrench port to the management switch. Strap the cables to the cable management arms.
1 3 2 4

SPD LNK /

SPD LNK /

1 2
1 2 3 4 5 6 7 8

3
9 10 11 12 13 14 15 16

DATA SWITCH

11

13

15

11

13

15

1000/100/10M LNK / 1000/100/10M LNK /

10

12

14

16

10

12

14

16

MANAGEMENT SUBNET

See your network administrator for help connecting to your switch.

See your network administrator for help connecting to your switch.

Connect both power cords


LNK LNK

Both power cords MUST be used for all units.


!
+ -

Power cords

0b

0a

DO NOT power on system at this point.


Use retaining clips

Use retaining clips

HELPFUL LINKS ON PAGE 4

3
A

Cable storage

(Choose option A, B, or C below)

Cabling FAS2220/2240-2 systems with NO external storage


Storage cables

No additional cabling required for single controller.


LNK LNK
e0a e0c

Cable SAS ports


Network cables

LNK

LNK

e0a

e0c

LNK

LNK

e0a

e0c

0b

0a
e0b e0d

0b

0a
e0b e0d

0b

0a
e0b e0d

AC

AC

AC

AC

Cable ACP ports

Single controller model

Double controller model


(Multipath HA)

STOP HERE. If you have NO external storage, skip to

Cabling FAS2220/2240-2 systems WITH external storage DS424x disk shelves


Storage cables
LNK LNK
e0a e0c

LNK

LNK

e0a

e0c

LNK

LNK

e0a

e0c

0b

0a
e0b e0d

0b

0a
e0b e0d

0b

0a
e0b e0d

1 2 3

Daisy chain SAS ports Cable rst SAS ports Cable last SAS ports
Network cables
1 3

AC

AC

AC

AC

N
LINK LINK
2 4

IOM3
1 3 2 4

N
LINK LINK

IOM3

Disconnect all supply power for complete isolation.

Disconnect all supply power for complete isolation.

N
1 2 4

IOM3
1 3 2 4

IOM3

N
LINK LINK
1 3 2 4

IOM3
1 3 2 4

N
LINK LINK

IOM3

Disconnect all supply power for complete isolation.

Disconnect all supply power for complete isolation.

N
1 3 2 4

IOM3
1 3 2 4

IOM3

Disconnect all supply power for complete isolation.

Disconnect all supply power for complete isolation.

Single controller model


(Dual path to external drives, single path to internal drives)

Double controller model


(Multipath HA)

Cabling FAS2220/2240-2 systems WITH external storage DS2246 disk shelves


Storage cables
LNK LNK
e0a e0c

LNK

LNK

e0a

e0c

LNK

LNK

0b

0a
e0b e0d

0b

0a
e0b e0d

0b

0a
e0b e0d

1 2 3

Daisy chain SAS ports Cable rst SAS ports


IOM3

AC

AC

AC

AC

AC

AC

AC

Network cables

AC

AC

AC

Single controller model


(Dual path to external drives, single path to internal drives) HELPFUL LINKS ON PAGE 4

Double controller model


(Multipath HA)

For additional congurations, see HELPFUL LINKS.

IOM3

IOM3

IOM3

IOM3

Cable ACP connections

IOM3

IOM3

IOM3

IOM3

IOM3

IOM3

Cable last SAS ports

IOM3

IOM3

IOM3

AC

AC

Disconnect all supply power for complete isolation.

Disconnect all supply power for complete isolation.

Disconnect all supply power for complete isolation.

IOM3

IOM3

IOM3

Disconnect all supply power for complete isolation.

Disconnect all supply power for complete isolation.

Disconnect all supply power for complete isolation.

IOM3

Cable ACP connections

Disconnect all supply power for complete isolation.

Disconnect all supply power for complete isolation.

Disconnect all supply power for complete isolation.

IOM3
Disconnect all supply power for complete isolation. 3 1 4 2

IOM3
LINK LINK

LINK

LINK

IOM3
LINK LINK

LINK

LINK

IOM3
LINK LINK LINK LINK LINK LINK LINK LINK

e0a

e0c

IOM3

LINK LINK

LINK LINK

LINK LINK

LINK LINK

IOM3

Complete System Setup


1

Complete conguration worksheet


Editable worksheet is available on the USB ash drive.

Cable Windows client


Cable your Windows client to the
same network as your controllers.

WINDOWS CLIENT

VLAN

FAS2220/2240-2 SYSTEM
LNK LNK

+ -

0b

0a

AC

AC

11

13

15

Install System Setup software


Insert USB ash drive into USB port and install software.

11

13

15

1000/100/10M LNK / 1000/100/10M LNK /

10

12

14

16

10

12

14

16

MANAGEMENT SUBNET

Start System Setup software


LNK LNK

1
+ -

e0a

e0c

LNK

LNK

+ -

e0a

e0c

When directed, power on your system (or repower). the system.


0b 0a

0b
e0b e0d

0a
e0b e0d

Wait for discover to complete.

Both power supplies MUST be powered on.

Enter the values from the conguration worksheet into System Setup.*
*If you cannot use System Setup, see the Data ONTAP Software Setup Guide.

Complete conguration
1

Register at support.netapp.com
Create an account. Register your system. Get your license keys.

Download OnCommand System Manager


Provision more storage. Congure other protocols and data protection. Set up Service Processor and Remote Support Agent.

HELPFUL LINKS Visit the NetApp web site for more information.
System Setup information: http://support.netapp.com/NOW/public/system_setup/ Site Requirements Guide: https://library.netapp.com/ecm/ecm_get_le/ECMP1112530 Controller and conguration examples: http://support.netapp.com/documentation/productlibrary/index.html?productID=61397 OnCommand System Manager documentation set: http://support.netapp.com/documentation/productlibrary/index.html?productID=61372 Data ONTAP 8 library: http://support.netapp.com/documentation/productlibrary/index.html?productID=30092 Licenses: http://support.netapp.com/eservice/agree.do?moduleName=PROTOCOL

HELPFUL LINKS Visit the NetApp web site for more information.
System Setup landing page Site Requirements Guide

LEARN MORE
Getting Started and training videos: https://communities.netapp.com/community/netapp_university/getting_started NetApp solutions: http://www.netapp.com/us/solutions/ Technical reports: http://www.netapp.com/us/library/technical-reports.html General information: http://www.netapp.com/us/library/

Conguration examples for FAS2220/2240-2 systems


OnCommand System Manager documentation set

Data ONTAP library


Storage Management Guide Logical Storage Management Guide File Access & Protocols Management Guide Data Protection Guide

License site for your system