Two component
solvent free epoxy
adhesive for
construction joints and
for monolithic sealing
of cracks in screeds

WHERE TO USE and high mechanical characteristics in addition to its


• Monolithic construction joints between fresh and old ability to bond concrete to steel.
concrete.
RECOMMENDATIONS
• Bonding precast concrete elements. • Do not apply Eporip at temperatures lower than +5°C.
• Bonding steel to concrete. • Do not use Eporip on wet surfaces (even though they
can be slightly damp).
• Filling cracks in concrete.
• Do not cast fresh concrete onto hardened Eporip.
Some application examples
• Construction joints for the structural reinforcement of • Do not use Eporip on dusty, crumbling or loose
beams and pillars. surfaces.

• Construction joints on decayed industrial flooring. APPLICATION PROCEDURE


Preparing the substrate
• Rigid, waterproof construction joints (e.g. concrete Before the application of Eporip, the substrate must be
bed to tank walls). perfectly clean, solid and strong.

• Reinforcement of beams by means of the plated All loose and crumbling parts, dust, cement laitance and
concrete technique. traces of form-release oils and paint must be eliminated
by careful sandblasting or brushing.
• Sealing cracks in cement screeds.
When applying the product to metal, remove any rust
TECHNICAL CHARACTERISTICS and grease residues beforehand, preferably by means of
Eporip is a solvent-free epoxy adhesive consisting of sand-blasting to white metal.
two pre-measured components (part A = resin, part B =
hardener) that have to be mixed before use. Preparing the mix
The two Eporip components have to be mixed. Pour
Eporip has the consistency of a slightly thixotropic part B (white) into part A (black) and mix with a trowel
paste that can be applied by brush on both horizontal for small quantities or with a drill fitted with a low speed
and vertical surfaces. stirrer for large batches until the mix is perfectly smooth
and even (the same grey all through).
Eporip polymerises without shrinkage and, after curing,
is waterproof, possesses excellent dielectric properties Do not use partial amounts to avoid the risk of

[sche1] 366 Inglese - 1 (EPORIP) (26.03.2002 - 4ª Bozza/Ciano Digitale/Pell.)


rip
po TECHNICAL DATA (typical values)

E PRODUCT IDENTITY

Component A Component B

Consistency: runny paste runny paste

Colour: black white

Specific gravity (g/cm3): 1.45 1.02

Brookfield viscosity (mPa • s): 18000 1500


(6 shaft - 10 rev) (2 shaft - 10 rev)

Storage: 24 months in unopened original packaging at a


temperature not lower than +5°C

Hazard classification according to EEC 88/379: irritant irritant


Before use, consult the “Safety Instructions”
paragraph and the information on the packing and
safety data sheet

Customs class: 3506 99 90


Applying Eporip by
brush on construction
joint APPLICATION DATA

Mixing ratio: Part A : Part B = 3 : 1

Consistency of mix: runny paste

Colour of mix: grey

Specific gravity of mix (g/cm3): 1.35

Brookfield viscosity (mPa • s): 4500 (5 shaft - 20 rev)

Pot life (min.):


– at +10°C: 90
– at +23°C: 60
– at +30°C: 40

Open time (hours):


– at +10°C: 5-6
– at +23°C: 3-4
– at +30°C: 1.5-2.5

Minimum application temperature: +5°C

Final curing time: 7 days


Repairing a crack in
cement screed with FINAL PERFORMANCES
Eporip

Adhesion to concrete (N/mm2): 3.0 (concrete failure)

Compressive strength (N/mm2) (ASTM C 579): 50

Flexural strength (N/mm2) (ISO 178): 35

Modulus of elasticity on compression (N/mm2)


(ASTM C 579): 3500

Modulus of elasticity on flexion (N/mm2)


(ISO 178): 2500
accidental ratio errors that could prevent PACKAGING
Eporip from curing fully or partially. 10 kg packages
(7.5 kg of Part A, 2.5 kg of Part B).
Applying the mix
Eporip can be applied with a flat trowel or a 2 kg packages
brush on dry or damp concrete. (1.5 kg of Part A, 0.5 kg of Part B).

It is advisable to let the product penetrate STORAGE


well into particularly uneven and porous areas 24 months in original packaging.
so as to ensure perfect adhesion to the whole Eporip should be stored indoors in a cool,
surface being treated. dry place where the temperature is between
+5°C and +30°C.
The subsequent layer of fresh concrete must
be placed within the open times according to SAFETY INSTRUCTIONS FOR THE
the temperature scales indicated in the PREPARATION AND APPLICATION
technical data. Both components of Eporip are irritant by
direct contact.
When Eporip is used to seal cracks wider Furthermore, following repeated contact,
than 0.5 mm, simply placing is sufficient. In sensibility of the skin could occur.
this case it is recommended to spread sand Always use gloves while applying the product
over the Eporip surface in order to favor and especially protect eyes while mixing the
bonding of product that may be applied two components. In case of contact with the
subsequently. If the cracks are narrower than skin, wash with plenty of water and soap and
0.5 mm, they have to be widened and then if de-sensibilisation phenomena occour,
dusted well before repair work with Eporip. consult a doctor.
In case of contact with the eyes wash with
Do not use Eporip when the outside plenty of running water and consult a doctor.
temperature of the substrate is lower than
+5°C. FOR PROFESSIONALS.

Cleaning WARNING
Tools used to prepare and apply Eporip must N.B. Although the technical details and
be cleaned with solvents (ethyl alcohol, xylol, recommendations contained in this report
toluol, and so on) immediately after use. correspond to the best of our knowledge and
experience, all the above information must, in
CONSUMPTION every case, be taken as merely indicative and
Consumption varies, depending on subject to confirmation after long-term
irregularities in the substrate and the method practical applications; for this reason, anyone
used in application. who intends to use the product must ensure
beforehand that it is suitable for the
Generally speaking: envisaged application. In every case, the user
alone is fully responsible for any
• construction joints with a rough substrate: consequences deriving from use of the
0.5-0.7 kg/m2 product.

• construction joints with a very uneven


substrate: 1.0-2.0 kg/m2

• sealing cracks: 1.35 kg per litre of cavity All relevant references


• bonding precast elements in concrete, or of the product are available
steel-and-concrete: 1.35 kg/m2 per mm upon request
thickness.
rip
po
E

(GB) A.G. BETA


Any reproduction of texts, photos and illustrations published
here is prohibited and subject to prosecution
®

BUILDING THE FUTURE

MAPEI GROUP CERTIFIED MANAGEMENT SYSTEMS


(Quality, Environment and Safety)

OCCUPATIONAL HEALTH
366-3-2002

AND SAFETY
MANAGEMENT SYSTEMS
MAPEI PLANT IN
ROBBIANO DI MEDIGLIA (MI)

OHSAS 18001 Standard


CERTIQUALITY Certificate No. 3586
No. 250/2 /

MAPEI S.p.A. - ITALY

CERTIQUALITY QMI DNV DNV CERTIQUALITY ITC


No. 1517/1 No. 004157 No. 94-OSL-AQ-6236 No. 216 80 159 No. 3358 No. 00 0083 SJ

MAPEI FRANCE MAPEI INC - CANADA RESCON MAPEI AS - NORWAY MAPEI KFT. - HUNGARY MAPEI FAR EAST Pte Ltd MAPEI Sro - CZECH REP.

S-ar putea să vă placă și