Sunteți pe pagina 1din 2

MICROPILE DESIGN CALCULATION BH1 193.

7 MM MICROPILE Lime stone depth = total pile depth = 3 7 m m

Column working load = ultimate pile capacity .: Pu = 1.5 X column working load = 712.5 kN 193.7 16 89.3 6.31 367 552 class of section = = mm mm cm2 cm cm3 N/mm2

475

kN

0.5 = (275/P y) = 0.71

diameter thickness area r z py

402=

19.93

semi compact 12.11

Table 7 BS 5950 402

nominal effective length, L E = = slenderness ratio, = = LE/r 94.29

0.85L 5.95

Table 24 BS 5950 m

round,square or flat bar, thick <40mm = pc from strut table 27(b) = 183 Agpc = 1634.19

27 (b)

Table 25 BS 5950

compression resistance P c =

kN

after calculation P c > Pu

DESIGN PASS

AXIALLY LOADED MEMBERS WITH MOMENTS tension F Ae py + MX MCX + MY MCY 1.0

MX MrX

Z1

MY MrY

Z2

1.0

0 552X 0.00893 0 49293.6 0.00 compression 0 552 X 0.00893 0 49293.6 0.00

0.00 552 x 0.000367 0.00 202.584 1.0 DESIGN PASS

0.00 552 x 0.000367 0.00 202.584 1.0 DESIGN PASS