Sunteți pe pagina 1din 4

PRESSURE TRANSMITTER ATM

23

Features

Typical applications Drucktransmitter mit

Compact and robust stainless steel Machine installations piezoresitivem Messelement. assembly 1.4435 (316L) Industrial process control Piezoresistive measuring element Heating and ventilation Gauge, absolute or sealed gauge Environmental monitoring Standard DIN pressure ranges from Food industry 0100 mbar to 01000 bar Mobile hydraulics Calibration available for all common Test and calibration systems pressure units Complies with the EMC directive EN 61000 Reverse polarity and short circuit protected Media temperature up to 150C (option) Surge (lightning) protection according to EN 61000-4-5 (option)

- feel the Difference

Specifications
Pressure range Overpressure [bar] 0.1 0.5 3 bar > 0.5 2 3 x FS
(min. 3 bar)

> 2 25 3 x FS

> 25 600 3 x FS
(max. 850 bar, optional 1500 bar)

> 600 1000 1500 bar

Burst pressure Accuracy1) Thermal shift Zero Span Response time


1)

[bar] [ % FS] [ % FS/C] 070C -2585C 070C -2585C

> 200 0.5

> 200 0.5

> 200 0.5

> 850
(optional 1500 bar)

> 1500 1

(optional 0.25)

(optional 0.25, 0.1)

(optional 0.25, 0.1)

(optional 0.25, 0.1)

0.5

(optional 0.5, 0.25)

0.06 0.08 0.015 0.02 < 1 ms/1090% FS

0.03 0.04 0.015 0.02

0.015 0.02 0.015 0.02

0.015 0.02 0.015 0.02

0.015 0.02 0.015 0.02

Long term stability (1 year) - (typ./max.) <0.5% FS/<4 mbar Output signal Type Supply voltage Supply voltage influence Circuit diagram 4 20 mA Two wire current transmitter 933 V DC < 0.1% FS

<0.2% FS/<4 mbar

<0.1% FS/<0.2% FS 0 20 mA

<0.1% FS/<0.2% FS

<0.1% FS/<0.2% FS

Zero based non-conformity according to DIN 16086, including hysteresis and repeatability

0 5 V / 0 10 V Three wire voltage transmitter 1530 V DC < 0.1% FS

Three wire current transmitter 933 V DC < 0.1% FS

Load resistance

[Ohm] 1000 RL<

UB[V] - 9V 0.02A

[Ohm] 1000 RL<

UB[V] - 6V , 1kOhm max 0.02A

RL > 10kOhm

500

RL
0 10 20 30 [V]

500

RL
0 10 20 30 [V]

UB

UB

Load resistance influence

< 0.1% FS Materials

< 0.1% FS

< 0.1% FS

Process connection, diaphragm, housing Stainless steel 1.4435 (316L) other materials (e.g. titanium) on request Seals (standard) Viton (other materials see ordering information)

Electromagnetic compability
Standard Emission: EN 61000-6-3 EN 55022 Immunity: EN 61000-6-2 EN 61000-4-2 EN 61000-4-3 EN 61000-4-3 EN 61000-4-4 EN 61000-4-6 EN 61000-4-5
2)

Level

Typical interferences

Generic emission standard Emission, class B Generic immunity Electrostatic discharge Radiated electro-magnetic field Radiated electro-magnetic field (GSM) Fast transients (burst) Conducted radio-frequency Surge

4kV contact, 8kV air 10V/m, 80-1000 MHz, 80% AM 1kHz 10V/m, 950 MHz, 200Hz on/off 2 kV 10V, 0.15-80 MHz, 80% AM 1kHz 10 kA (8/20 ms) 2)

Cellular phones, radio sets Digital portable phones Motors, valves Cellular phones, radio sets Lightning strikes

Only with optional surge (lightning) protection

The pressure transmitter ATM fulfils the emission and immunity requirements described in the EMC directive EN 61000.

Ordering Information
Type Pressure type ATM Gauge Absolute Sealed gauge 0100 mbar 0160 mbar 0250 mbar 0400 mbar 0600 mbar 01.0 bar 01.6 bar 02.5 bar 04.0 bar 06.0 bar 010 bar 016 bar 025 bar 040 bar 060 bar 0100 bar 0160 bar 0250 bar 0400 bar 0600 bar 01000 bar Special calibration G 1/4 female G 1/4 M G 1/4 M, Manometer DIN 16288 G 1/2 M G 1/2 M, frontal diaphragm G 1/2 M, flush diaphragm G 1/2 M, Manometer DIN 16288 1/4 NPT M 1/2 NPT M Special process connection Connector DIN 43650 (screwed on3)) 5) Connector Binder 723, 5-pin 5) Connector Binder 723, 5-pin (screwed on3)) 5) Connector MIL C26482, (10-6) 5) PE cable 6) 7) 8) PUR cable 6) 7) Teflon cable 6) Special electrical connection 0 5 V DC 010 V DC 020 mA 420 mA 420 mA surge (lightning) protection 010 V DC surge (lightning) protection Special output signal 0.5 % FS 0.25 % FS 0.1 % FS (on request)

23 X . XXXX . XXXX . XX . XXX


23 1 2 3 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 99 00 11 12 13 14 15 16 10 19 99 IP 65 IP 67 IP 67 IP 40 IP 67 IP 67 IP 67 01 03 43 06 13 15 21 99 46 47 00 05 08 49 99 0 1 2 0 1 2 9 A C D G H U S T Z

Pressure range

3 3 3 3 3 3 3 3 (Fig. 1) (Fig. 2) (Fig. 3) (Fig. 4) (Fig. 5) (Fig. 6) (Fig. 7) (Fig. 8) (Fig. 10) (Fig. 11) (Fig. 12) (Fig. 13) (Fig. 14) (Fig. 14) (Fig. 14)

Process connection

Electrical connection

Output signal

Accuracy

Temperature range

Options

Compensated 070C (medium temperature 0 80C) Compensated -2585C (medium temperature -25100C) 7) Compensated -2585C (medium temperature -25150C) 7) Special temperature range Throttle 4) Electronics packed in gel: Gauge pressure Absolute and sealed gauge pressure Special oil filling in the TD: ASEOL Food Halocarbon Seals: Viton (Standard) EPDM Kalrez Special options
6) 7)

3) 4)

Zero offset and span adjustable Available only with fig. 2, fig. 4 or fig. 7 5) Cable socket connector not included

Please specify the required cable length For medium temperature > 50C a teflon cable must be used 8) Suitable for drinking water (food approved)

Pressure Connection

Dimensions
Version for medium temperature up to 100C

Electrical Connection
46.5

Pin 1 2 3

2-Wire 3-Wire +Vin Pout +Vin Pout GND

G 1/4 F

SW27

32,5
12

Fig. 1

24

Fig. 10
1

3 2

G 1/4 M

32,5

SW27

L = 40 mm for connector DIN 43650 (Fig. 10) L = 45 mm for all other versions L = 94 mm for version with surge (lightning) protection

Fig. 2

16

Version for medium temperature up to 150C


G 1/4 M SW27

Fig. 11

68

35,5
13,5

Fig. 3

Cable socket connector


3 2 1 4 5

G 1/2 M

L
SW27

32,5
20,5

Fig. 4

L = 67 mm for connector DIN 43650 (Fig. 10) L = 72 mm for all other versions L = 121 mm for version with surge (lightning) protection

24

Pin 2-Wire 3-Wire 1 3 4


74.5

Pout +Vin

Pout +Vin GND

G 1/2 M 18,4

SW27

Fig. 12 Fig. 5
Cable socket connector
A B F E D

34,5

19,5
G 1/2 M

18,4

SW27

33,5

Fig. 6

Pin 2-Wire 3-Wire A B C +Vin Pout +Vin GND Pout

25
G 1/2 M

Fig. 13
SW27

62.5

43
17

Fig. 7

Colour white yellow brown

2-Wire 3-Wire +Vin Pout +Vin GND Pout

1/2 NPT M

SW27

Fig. 14

PG9

31,5

Fig. 8
DED011A

Release 02/2003

S-ar putea să vă placă și