Sunteți pe pagina 1din 4

PRESSURE TRANSMITTER FOR LEVEL MEASUREMENT ATM/N

24

Features

Typical applications Drucktransmitter mit

Compact and robust stainless steel assem- piezoresitivem Depth and level measurement in Messelement. bly 1.4435 (316L) or titanium (option) Wells Piezoresistive measuring element Bore holes Gauge or absolute Waste water Standard DIN pressure ranges from Reservoirs 0100 mbar to 025 bar Lakes, rivers Calibration available for all common Sewage treatment plant pressure units mH2O, mWG, mWC etc. Complies with the EMC directive EN 61000 High reliability Available with PE, PUR or Teflon cable, also connectable Reverse polarity and short circuit protected Surge (lightning) protection according to EN 61000-4-5 (option)

- feel the Difference

Specifications
Pressure range Overpressure [bar] 0.1 0.5 3 bar > 0.5 2 3 x FS (min. 3 bar) > 200 0.5 (optional 0.25, 0.1) 0.03 0.04 0.015 0.02 0.2% FS/< 4 mbar > 2 25 3 x FS

Burst pressure Accuracy1) Thermal shift Zero Span

[bar] [ % FS] [ % FS/ C] 070C -2585C 070C -2585C

> 200 0.5 (optional 0.25) 0.06 0.08 0.015 0.02 0.5% FS/< 4 mbar

> 200 0.5 (optional 0.25, 0.1) 0.015 0.02 0.015 0.02 0.1% FS/< 0.2% FS

Long term stability (1 year) - (typ./max.)


1)

Zero based non-conformity according to DIN 16086, including hysteresis and repeatability

Output signal Type Supply voltage Supply voltage influence Circuit diagram

4 20 mA Two wire current transmitter 933 V DC < 0.1% FS

0 20 mA Three wire current transmitter 933 V DC < 0.1% FS

0 5 V / 0 10 V Three wire voltage transmitter 1530 V DC < 0.1% FS

Load resistance

[Ohm] 1000 RL<

UB[V] - 9V 0.02A

[Ohm] 1000 RL<

UB[V] - 6V , 1kOhm max 0.02A

RL > 10kOhm

500

RL
0 10 20 30 [V]

500

RL
0 10 20 30 [V]

UB

UB

Load resistance influence

< 0.1% FS Materials

< 0.1% FS

< 0.1% FS

Process connection, diaphragm, housing Stainless steel 1.4435 (316L) other materials (e.g. titanium) on request Seals (standard) Viton (other materials see ordering information)

Electromagnetic compability
Standard Emission: EN 61000-6-3 EN 55022 Immunity: EN 61000-6-2 EN 61000-4-2 EN 61000-4-3 EN 61000-4-3 EN 61000-4-4 EN 61000-4-6 EN 61000-4-5
2)

Level

Typical interferences

Generic emission standard Emission, class B Generic immunity Electrostatic discharge Radiated electro-magnetic field Radiated electro-magnetic field (GSM) Fast transients (burst) Conducted radio-frequency Surge

4kV contact, 8kV air 10V/m, 80-1000 MHz, 80% AM 1kHz 10V/m, 950 MHz, 200Hz on/off 2 kV 10V, 0.15-80 MHz, 80% AM 1kHz 10 kA (8/20 ms) 2)

Cellular phones, radio sets Digital portable phones Motors, valves Cellular phones, radio sets Lightning strikes

Only with optional surge (lightning) protection

The pressure transmitter ATM fulfils the emission and immunity requirements described in the EMC directive EN 61000.

Ordering Information
Type Pressure type ATM/N Gauge Absolute

24 X . XXXX . XXXX . XX . XXX


24 1 2

Pressure range 6)

0100 mbar 0160 mbar 0250 mbar 0400 mbar 0600 mbar 01.0 bar 01.6 bar 02.5 bar 04.0 bar 06.0 bar 010 bar 016 bar 025 bar Special calibration

00 01 02 03 04 05 06 07 08 09 10 11 12 99

Version

Closed version Open version G 1/4 M G 1/2 M Special version 3) Connectable version 4) PE cable 1) 2) 5) PUR cable 1) 2) Teflon cable 1) 0 5 V DC 010 V DC 020 mA 420 mA 420 mA surge (lightning) protection 010 V DC surge (lightning) protection Special output signal 0.5 % FS 0.25 % FS 0.1 % FS (on request)

(Fig. 1) (Fig. 2) (Fig. 3) (Fig. 3)

55 56 11 13 99 IP68 IP68 IP68 IP68 07 13 15 21 46 47 00 05 08 49 99 0 1 2 0 1 9 K B C D G H U S T Z

Electrical connection

(Fig. 4)

Output signal

Accuracy

Temperature range

Compensated 070C (medium temperature 0 80C) 2) Compensated -2585C (medium temperature -25 85C) 2) Special temperature range Version titanium Ballast weight Electronics packed in gel: Gauge pressure Absolute and sealed gauge pressure Special oil filling in the TD: ASEOL Food Halocarbon Seals: Viton (Standard) EPDM Kalrez Humidity filter element
4) 5)
6)

Options

1)
2)

Please specify the required cable length and medium For medium temperature > 50C a teflon cable must be used 3) Other versions or process connections on request

Connector with required cable has to be ordered separately (KART100) Suitable for drinking water (food approved)
mH2O, mWG, mWC ets. available

Dimensions

Fig. 1: Closed version

Fig. 2: Open version

Fig. 3: with process connection

Fig. 4: Electrical connection, connectable

6 PE, PUR cable 5 Teflon cable

24

24
24

24

SW27
O-Seal

Standard without ballast weight with ballast weight

A [mm] 108 195

B [mm] 104 191

C [mm]

D [mm]

Weight [g]

on request* on request* approx. 160 on request* on request* approx. 420

*C: Depending on process connection *D: Depending on process connection or version Version with surge (lightning) protection A [mm] without ballast weight with ballast weight 157 244 B [mm] 153 240 C [mm] on request on request D [mm] on request on request Weight [g] approx. 200 approx. 460 Colour 2-Wire 3-Wire white +Vin yellow Pout brown +Vin GND Pout
3 2

5 4 1

Specifications may change without notice.

DED012A