3RW4075-6BB44
General details:
Product brand name Product equipment integrated bridging contact system thyristors Product function intrinsic device protection motor overload protection evaluation of thermal resistor motor protection reset external adjustable current limitation inside-delta circuit Product component / outlet for enine brake Item designation according to DIN EN 61346-2 according to DIN 40719 extendable after IEC 204-2 / according to IEC 750 Q G Yes Yes No Yes Yes No No Yes Yes SIRIUS
Power Electronics:
Product designation Operating current soft starters for standard applications
3RW4075-6BB44 Page 1/ 6
11/14/2010
at 40 C / rated value at 50 C / rated value at 60 C / rated value Emitted mechanical power / for three-phase servomotors at 230 V / at standard switching / at 40 C rated value at 400 V / at standard switching / at 40 C rated value Yielded mechanical performance (hp) / for three-phase servomotors at 200 V / at standard switching at 50 C / rated value at 230 V / at standard switching at 50 C / rated value at 460 V / at standard switching at 50 C / rated value Operating frequency rated value Relative negative tolerance / of the operating frequency Relative positive tolerance / of the operating frequency Operating voltage / with standard circuit / rated value Relative negative tolerance / of the operating voltage / with standard circuit Relative positive tolerance / of the operating voltage / with standard circuit Minimum load in % of l_M Adjustable rated current / of the motor / for motor overload protection / minimum Continuous operating current in % of l_e / at 40C Active power loss / with operating current / at 40C / during operating phase / typical
A A A
kW
110
kW
200
hp
100
hp
125
hp
250
Hz % % V %
10
% A
20 131
% W
115 125
Control electronics:
Type of voltage / of the controlled supply voltage Control supply voltage frequency / 1 / rated value Control supply voltage frequency / 2 / rated value Relative negative tolerance / of the control supply voltage frequency Relative positive tolerance / of the control supply voltage frequency Control supply voltage / 1 at 50 Hz / for AC V 230 Hz Hz % AC 50 60 -10
10
3RW4075-6BB44 Page 2/ 6
11/14/2010
at 60 Hz / for AC Relative negative tolerance / of the control supply voltage / at 60 Hz / for AC Relative positive tolerance / of the control supply voltage / at 60 Hz / for AC
V %
230 -15
10
Mechanical design:
Size of the engine control device Width Height Depth Type of mounting Built in orientation mm mm mm S12 160 230 278 screw fixing With additional fan: With vertical mounting surface +/90 rotatable, with vertical mounting surface +/- 22.5 tiltable to the front and back Without additional fan: With vertical mounting surface +/-10 rotatable, with vertical mounting surface +/- 10 t
Distance, to be maintained, to the ranks assembly upwards sidewards downwards Altitude of installation site / at a height over sea level Cable length / maximum Number of poles / for main current circuit mm mm mm m m 100 5 75 5000 300 3
Electrical connections:
Design of the electrical connection for main current circuit for auxiliary and control current circuit Number of NC contacts / for auxiliary contacts Number of NO contacts / for auxiliary contacts Number of change-over switches / for auxiliary contacts Type of the connectable conductor cross section / for main contacts / for box terminal / when using the front clamping point finel y stranded/ with conductor end processing finel y stranded/ without conductor end processing stran ded Type of the connectable conductor cross-section / for main contacts / for box terminal / when using the back clamping point finely stranded/ with conductor end processing 120 ... 185 mm2 70 ... 240 mm2 busbar connection screw-type terminals 0 2 1
3RW4075-6BB44 Page 3/ 6
11/14/2010
withou t conductor final cutting / without conductor end processing strand ed Type of the connectable conductor cross-section / for main contacts / for box terminal / when using both clamping points finely strande d/ with conductor end processing without conduc tor final cutting / without conductor end processing stranded Type of the connectable conductor cross-section / for AWG conductors / for main contacts / for box terminal when using the back cl amping point when using the front c lamping point when using both clampi ng points Type of the connectable conductor cross-section / for DIN cable lug / for main contacts finely stranded stranded Type of the connectable conductor cross-section for AWG conductors / for main contacts Type of the connectable conductor cross-section for auxiliary contacts solid finely stranded / with conductor end processing for AWG conductors / for auxiliary contacts finely stranded / with wire end proc essing
2x (0.5 ... 2.5 mm2) 2x (0.5 ... 1.5 mm2) 2x (20 ... 14) 2x (20 ... 16)
Ambient conditions:
Ambient temperature during the operating phase during storage Derating temperature Protection class IP C C C -25 60 -40 80 40 IP20
Certificates/approvals:
3RW4075-6BB44 Page 4/ 6
11/14/2010
Shipping Approval
other Manufacturer
Further information:
Information- and Downloadcenter (Catalogs, Brochures,) http://www.siemens.com/industrial-controls/catalogs Industry Mall (Online ordering system) http://www.siemens.com/industrial-controls/mall CAx-Online-Generator http://www.siemens.com/cax Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/3RW4075-6BB44/all Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3RW4075-6BB44
3RW4075-6BB44 Page 5/ 6
11/14/2010
last change:
3RW4075-6BB44 Page 6/ 6