Sunteți pe pagina 1din 1

EAuncased length = Agrout Egrout + Asteel Esteel =1,133,000 kN

Elastic Displacement

Elastic displacement (cased length)


telastic = Pcompression Lca sin g AEcased length = 595 kN 4.6 m = 2.2 mm 1,252,000 kN

Elastic displacement (uncased length)


telastic = Pcompression Lb AEuncased length = 595 kN (1 / 2 7.5 m) = 2.0 mm 1,133,000 kN

STEP 8 MICROPILE TO FOOTING CONNECTION DESIGN

Design calculations are completed for the detail shown in Figure S1-5 for connection of the pile top to the abutment footing.
Required Design Loads and Dimensions

Group I service load, compression Abutment concrete compressive strength Casing outside diameter Pile area Area pile =

Pc-service = 595 kN fc = 27.6 MPa ODcasing = 141 mm

OD 2 ca sin g = 15,615 mm 2

FHWA NHI-05-039 Micropile Design & Construction

D-16

Appendix D Sample Problem No.1 December 2005