Documente Academic
Documente Profesional
Documente Cultură
TI-P222-02
CH Issue 1
Description
Process water in
Receiver vent
Pressure/temperature limits
TMA Maximum allowable temperature Shell side Tube side 300C 200C -10C to +200C 12 bar g Shell side Maximum allowable PMA 200C to 300C 6 bar g pressure Tube side -10C to +300C 12 bar g The cold hydraulic tests are performed at 18 bar g for both sides (shell and tube). This pressure meets with the requirements of Section 7.4, attachment 1, of the European Pressure Equipment Directive 97/23/EC.
Available models:
Heat exchanger EVC 1" - 1F EVC 2" - 1F EVC 3" - 1F EVC 3" - 1F EVC 4" - 1F EVC 6" - 1F EVC 10" - 1F EVC 10" - 1F Steam massflow (kg/h) 30 50 75 100 200 300 500 750 Heat load (kW) 18.7 31.3 46.9 62.5 125.0 187.5 312.5 468.7 Water flow (kg/h) 50 to 70C* 804 1350 2020 2690 5370 8060 13400 20100 Maximum steam inlet 15 m/s DN32 DN40 DN65 DN65 DN80 DN100 DN150 DN150 Condensate connection DN15 DN15 DN15 DN15 DN25 DN25 DN40 DN40 Shell connection DN40 DN50 DN80 DN80 DN100 DN150 DN250 DN250
* For calculations representative of other temperatures please contact Spirax Sarco or your local representative who will advise.
Local regulations may restrict the use of this product to below the conditions quoted. In the interest of development and improvement of the product, we reserve the right to change the specication without notice. Copyright 2010
The Spirax Sarco EVC is based on the Turflow heat exchanger with an additional connection and utilises flash steam from discharge and exhaust vent pipework to pre-heat make-up or process water thereby recovering valuable heat energy that would otherwise be lost to atmosphere. The Spirax Sarco EVC will improve steam system efficiency and is environmentally friendly, reducing CO2 + carbon emissions and removing visible discharges from the atmosphere whilst saving valuable energy. It is easy to install and provides an optimised heat transfer solution when compared to other heat exchanger designs used in similar applications. As standard the construction is completely stainless steel and the tube side is all in AISI 316. There are no gaskets (with the exception of the piping connection) and no painted components. The heat-exchanging surface is of straight corrugated tubes designed for low viscosity fluids and for turbulent flow working conditions. The tube sheets are of an integral type and are supplied ready for installation. Standards Designed and manufactured in accordance with the `Raccolta VSR Revision 1995 Edition 99' code and fully complies with the requirements of the European Pressure Equipment Directive 97/23/EC. Certification This product is available with a manufacturers Typical Test Report. Note: All certification/inspection requirements must be stated at the time of order placement
Page 2 of 3
Spirax Sarco has developed integrated thermal modelling, sizing and selection software, to select and fully optimise an EVC heat exchanger to precisely match your application needs. Trained technicians are available at your local Spirax Sarco company to ensure the correct heat exchanger is always selected. Because of Spirax Sarcos expertise and wide product range we can provide a complete heat transfer solution, advising on the most suitable control system and ancillary equipment for your heat exchanger. Our technicians can also advise on the suitability and sizing of heat exchangers for most gases, vapours and superheated liquids other than water.
Please note that other units are available on request to suit the specifics of a particular process application. EVC = Exhaust vapour condenser 1", 2", 3", 4", 6" and 10" SX = Stainless steel AISI 316 1 = 1 metre F = Flanged V Empty box = Expanding S = Welding Empty box = CE markings not required CI = Category I CII = Category II EVC 3" SX 1 F V S CI CI EVC 3" SX 1 F V
Materials
Flowrate m 3/h Good Optimum 2 2.5 4 5 7 10 11 16 23 20 28 41 47 65 93 110 187 264 Maximum 5 12 28 49 113 297 Component Shell Expansion joint Tube sheets Flanged connection Tubes (corrugated) Material Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel ASTM designation A312-TP304 A240-TP321 A182-F316/304 A182-F304 A249-TP316L
C DN2 DN3 Model EVC 1" - 1F EVC 2" - 1F EVC 3" - 1F EVC 4" - 1F EVC 6" - 1F EVC 10" - 1F DN1 32 40 65 80 100 150 DN2 40 50 80 100 150 250 DN3 15 15 15 25 25 40 DN1 A 94 90 110 125 140 180 B 140 140 160 180 220 280 C 48.3 60.3 88.9 114.3 168.3 273.0
Weight 18 19 30 37 62 190
Tolerance according to UNI 6100 and TEMA: D = 3 mm; B = 3 mm; Flange rotation = 1; Connection alignement = 1.5 mm.
TI-P222-02
ST Issue 1
Page 3 of 3
Typical installation:
Drain
Receiver vent
TI-P222-02
ST Issue 1