Sunteți pe pagina 1din 48

Peer

Industries Concealed Ceiling systems Technical Manual Index


Page

General information/ Warranty and design considerations Engineering design certification Technical services Certification, standards and testing Peer Concealed Ceiling Steel Products Concealed ceiling systems product breakdown Concealed ceiling systems installation using TCR and Furring Channel Multidirectional clip C79S Direct fixing of furring channel/TCR system Direct fixing of Furring Channel Drop ceiling/ceiling bulkhead Fire Rated ceilings Acoustic STC rated ceilings Typical concealed ceiling joists Curved and raked ceilings Plasterboard installation Expansions and control joints Design notes Span table CCS01 Ceiling Joists Span table CCS02 Top Hat 50 Span table CCS03 Top Hat 75 Span table CCS04 Top Hat 60 Span table CCS05 16mm Ceiling Batten Span table CCS06 -10 TCR25 and TCR38 with FC18 and FC28 Span tables CCS11 Cyclonic ceiling Batten 22 mm Clip capacity table CCS12 Sectional properties table SP-01 FCDB 16mm Ceiling Batten Sectional properties table SP-02 FCCB 22mm Cyclonic Ceiling Batten Sectional properties table SP-03 FC 18mm & 28mm Furring Channel Sectional properties table SP-04 Top Cross Rail 25mm and 38mm Sectional properties table SP-05 Top Hat 50mm & 75mm Notes

CCS01 CCS02 CCS03 CCS04-05 CCS06-11 CCS11-12 CCS12 CCS17 CCS18 CCS19 CCS20 CCS22 CCS23 CCS24 CCS25-27 CCS27-28 CCS29 CCS30 CCS31 CCS32 CCS33 CCS34 CCS35 CCS36-38 CCS39 CCS40 CCS42 CCS43 CCS44 CCS45 CCS46 CCS47-48

Peer Industries PIF-MSC-011 Rev 05 16/10/07 Concealed ceiling systems technical manual

General Information
This Technical manual contains details of Peer Industries cold roll formed and pressed steel products. Peer Industries provide this manual for use by Architects, Engineers, Designers, Contractors and Sub-Contractors to assist in product selection and use. It has been prepared using relevant Australian Standards together with sound engineering principles substantiated through laboratory tests. Peer Industries cold roll formed and pressed steel products are economical, efficient and durable structural members suitable for a wide range of building applications. Peer Industries steel products are manufactured in accordance with the requirements of relevant Australian and New Zealand Standards.

Warranty and Design Considerations


Peer Industries offers a warranty in keeping with Australian Standards and Project requirements of up to fifteen years. This Peer Technical manual is designed to provide a general guide to the design and application of Peer concealed ceiling systems. These systems comprise of top cross rails, furring channels, battens, and assorted suspension clips. Should you require information or design assistance related to systems outside those covered in this manual, you can contact Peer design on design@01peer.com or contact our nearest office by calling 1300 725 675 from anywhere in Australia. Peer Industries Pty Ltd will not be held responsible for any claims resulting from the use of Peer Industries products that have not been installed in accordance with the manufacturers recommendations, design manuals, or relevant Australian Standards. All installations must be carried out in accordance with this and other relevant technical updates.

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 1 of 47

Certification
Engineering Design Certificate

Umesh C Khatri RPEQ - 4829 is a registered professional engineer of Queensland and is an engineer with Peer Industries Pty Ltd being a manufacturer and supplier of the steel framing products. This is to certify that the span and height tables provided in this design manual for Peer Industries cold formed steel sections are in accordance with the requirements of the following Australian Standards: AS1538-1988/AS4600, Cold Formed Steel Structure Code. AS2785 -1985/2000 Suspended Ceiling Design and Installation. AS1250/4100 Steel Structure and Building Code of Australia. Umesh C Khatri RPEQ 4829 Customer Support Design Engineer BE Civil, CP Eng, MIE (Aust), RBP (Vic), RPEQ, NPER-3, MFIE, MIEI On behalf of Peer Industries Pty Ltd Dated October 2007.

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 2 of 47

Technical Services Peer Design


Peer Industries provides a complete design service and our structural engineers will assist you with the design phase of your project. This design manual has been prepared with a view to providing Architects, Engineers, Designers, Contractors and Subcontractors with: A convenient design aid in the form of maximum heights or maximum span tables. Design data - Section properties to enable the design of required configurations not covered in this manual. Installation and construction details.

The Height and Span Tables for Peer Industries steel products provides solutions for the following broad range of design conditions. Design loads which are uniformly distributed. Spans for single span, double spans and continuous spans as specified. Sizes of steel products with all dimensions. Steel products with nominated base metal thicknesses (BMTs). Load capacity tables with clip capacities

Contact our experts at Peer Design by email design@01Peer.com , call for our nearest office on 1300 725 675 or visit our website at www.Peerindustries.com.au

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 3 of 47

Testing and Standards


Australian and New Zealand Standards
AS1397 2001 Steel Sheet and Strip AS/NZS 4600-1996 & AS 1538 1988 AS/NZS 2588 - 1998 Hot Dipped Zinc-coated or Aluminium/Zinc coated SAA Cold Formed Steel Structures. Gypsum Plasterboard.

The Application and finishing of Gypsum Plasterboard in framed dwelling construction. AS1250 AS3566 AS/NZS2785 - 2000 & AS2785 1985 AS4055 1992 AS3623 -1993 AS1170 0, 1, & 2 2002/1989 AS1170.4 1993 NZ4203 1992 AS1530.4 1990 AS1191 1985 SAA Steel Structure Code. Screws - self-drilling - for the building and Construction industry. Suspended Ceilings Design and Installation. Wind Loads for Housing. Domestic Metal Framing. Dead, Live and Wind Loads. Earthquake Loads. Seismic Code. Fire Resistance Tests of Elements of Building Construction. Test Methods for Laboratory measurement of Airborne Sound Transmission Loss of Building Partitions. Tests to comply with the Building Code of Australia C1.8

Tests
BRANZ Test Report STR 213: Peer Industries Pty Ltd cold-formed steel studs are tested in conjunction with Plasterboard conforming to AS2588 for: (a) Resistance to Static Pressure Tests to ASTM E72-80 (b) Resistance to Impact Tests to ASTM E695-79 (c) Surface Indentation Tests to AS 2185 Appendix A2. Steel studs were tested as specified in (a), (b) and (c) above (see Test Report STR 213). The results were checked for compliance with the Building Code of Australia 1990 (BCA).

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 4 of 47

Testing and Standards contd


BRANZ Test Report FR1660, FR1661: Peer Industries Pty Ltd cold roll formed steel furring channels, top cross rails and battens are tested in conjunction with plasterboard complying with the Building Code of Australia (BCA) and AS1530.4 for: (a) (b) Fire Resistance Level (FRL) of 90/60/60 FR1660 Fire Resistance Level (FRL) of 120/90/120 FR1661

CSIRO Test Report STR 019: Peer Industries cold-formed steel furring channels, top cross rails and battens are tested in conjunction with plasterboard complying with AS2588 for airborne sound transmission loss. Note: Airborne-sound-transmission loss = sound transmission class Rw 32 as per AS 1276-1979 and the BCA

Material:
Peer Industries cold roll formed steel sections and pressed products are manufactured from zinc coated steel strip conforming to AS 1397 for thickness up to and including 1.55mm BMT (base metal thickness). The steel strip for the various section sizes has a minimum yield stress of 300 Mpa.

Coating:
All Peer Industries cold roll formed steel sections are coated with zinc with a minimum coating mass of 220 - 275 grams/m2 as indicated.

Performance
Peer cold roll formed steel sections and pressed products will perform as specified if used in accordance with the recommendations and details set down in this technical brochure and related design references together with good trade practices. Any variations from these recommendations and details will require special design and detailing. Information in this brochure is current at the time of printing. Specifications and recommendations are subject to change without notice. Whilst every care is taken at the time of the preparation of this brochure, Peer accepts no liability for any errors or ambiguities. Contact Peer office to discuss any such concerns. For applications outside the scope of this design manual, contact Peer design on design@01Peer.com or contact our nearest office by calling 1300 725 675 from anywhere in Australia.

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 5 of 47

Concealed Ceiling Steel Products


The Peer Industries concealed ceiling system utilises furring channels, top cross rails, rod and suspension clips to provide a flush ceiling finish. This concealed ceiling system is versatile and provides many options to the user. These concealed ceiling systems have been designed to meet Australian and New Zealand Standards together with sound engineering principles substantiated through laboratory tests.

Ceiling Systems are not Trafficable unless stated, and are designed to carry the weight of the ceiling only.
The Peer concealed ceiling system can be used in both fire rated and non fire rated situations using appropriate plasterboard or other suitable cladding materials. Peer Industries concealed ceiling systems can be used to build either a typical ceiling or an acoustically rated ceiling by using appropriate plasterboard. Acoustic ceilings with a specific STC rating can be achieved by using furring channel with resilient mounts and appropriate plasterboard. This suspended ceiling systems manual is designed to provide a general guide to the design and application of Peer Suspended Ceilings. For more information or design assistance related to systems outside those covered in this design manual, contact Peer Design by email on design@01Peer.com or our nearest customer service centre by calling 1300 725 675 for further advice.

Concealed Ceiling Steel Products

T18 - 150 track 18mm to 150mm

WSL51 - 150 Lipped Stud 51 to 150mm

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 6 of 47

Concealed Ceiling Steel Products

TH50 - 75- Top hat 50mm and 75mm

FC18 - 28- Furring channel 18mm and 28mm

C38- Furring channel 18 and 28 joiner

FCCB22 22mm Ceiling batten

FCDB 16mm Ceiling batten

CDB38 16mm Ceiling batten joiner

FCBBB Back blocking batten

TCR25/38- Top cross rail in 25mm and 38mm

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 7 of 47

Concealed Ceiling Steel Products contd

C21- 5mm suspension rod

C54 5mm suspension rod joiner

C74- Suspension rod bracket Purlin

C47-74 Suspension rod bracket multi purpose

C60- Adjustable suspension clip for TCR

C60DF- Adjustable suspension clip Purlin

C60LDF- Adjustable suspension clip for slab

C52 Spring adjustable C26-80 furring channel clip

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 8 of 47

Concealed Ceiling Steel Products contd

C24 Top cross rail direct fix clip to timber or steel

C66 Top cross rail direct fix clip to timber or steel

C26-80/180 Furring channel direct fix clip

CDB26-80/150 16mm Batten direct fix clip

C37-7H Furring channel anchor clip 7.5 hole

C37-M6- Furring channel anchor clip M6

CFCAM Furring channel adjustable mount

CFCRESAM F/C resilient adjustable mount

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 9 of 47

Concealed Ceiling Products contd

C79S Furring channel to TCR swivel clip

CFSAM Furring channel screw adjustable mount

C001 Furring channel acoustic mount

C001M6 Furring channel acoustic mount M6

C79SRES Furring channel to TCR acoustic mount.

C001-DCS Concrete to stud wall mount acoustic

CTCR100 600 Direct fix adjustable TCR

CTCRES100 600 Direct fix adjustable TCR


Acoustic

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 10 of 47

Concealed Ceiling Products contd

C39 Furring channel to top cross rails (Locking key)

CDB39 16mm batten to TCR clip

CDB37 16mm batten direct fix clip

CBET.FIX Furring channel direct fix adjustable

C61S TCR side mounts rod adjustable clip.

Concealed ceiling systems product breakdown


Suspension Systems
C21 C39 C74 C47-74 C60 C61S CDB39 CTROE CTRBE C79S Suspension rod (available up to 6000mm in length) Furring channel to top cross rails (Locking key) Suspension rod bracket Suspension rod bracket multi purpose Adjustable suspension clip for top cross rail Side mount TCR clip 16mm batten to TCR clip Threaded rod one end (available up to 6000mm in length) Threaded rod both ends (available up to 6000mm in length) Furring channel to TCR swivel clip (multidirectional)

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 11 of 47

Concealed Ceiling Product Breakdown contd


Direct Fix Clips for Furring Channels and 16mm Battens
C26-80 C26-180 C52 CDB26-80 CDB26-150 CDB37 CFCAM CBET.FIX Furring channel direct fix clip 80mm drop Furring channel direct fix clip 180mm drop Spring adjustable C26-80 furring channel Clip 16mm batten direct fix clip 80mm drop 16mm batten direct fix clip 150mm drop 16mm batten direct fix clip Furring channel adjustable mount Adjustable furring channel direct fix clip

Anchor Clips Furring Channel


C37-7H C37-M6 Furring channel anchor clip 7.5mm hole Furring channel anchor clip M6

Direct Fix Clips for Top Cross Rails


C24 C66 CTCR Top cross rail direct fix clip to timber or steel Top cross rail direct fix clip to timber or steel Direct fix adjustable TCR

Misc Components
C54 C38 CDB38 CTP60 CFCSAM Adjustable suspension rod joiner Furring channel joiner 16mm batten joiner Suspension rod slab tap in anchor 60mm Furring channel screw adjustable mount (smart clip)

Accessories for Acoustic (STC) Ceiling


C001 C79SRES C001-DCS CFCRESAM CTCRRES Furring channel resilient acoustic mount Furring channel to TCR resilient mount. Concrete to stud wall mount acoustic. Furring channel resilient adjustable mount Direct fix adjustable TCR acoustic

Top Hats
TH75-115 TH50-115 Top Hat 20x35x75x35x20 Top Hat 20x35x50x35x20

Ceiling Battens
FCDB FCCB22-61 16mm domestic batten Furring channel ceiling batten 22mm Cyclonic

Furring Channel and Furring channel Track


FC18 & FC28 T18 & T28 Furring channel 18mm and 28mm Furring channel Track 18 mm and 28mm

Ceiling Joists Studs Wall Studs Lipped - Marked as WSL


Stud sizes 51mm (WSL51), 64mm (WSL64), 76mm (WSL76), 92mm (WSL92), 150mm (WSL150) Stud material base metal thickness (BMT) 0.50mm, 0.55mm, 0.75mm, 1.15mm and 1.55mm

Ceiling Joists End Support Tracks - Marked as T


Track sizes 51mm (T51), 64mm (T64), 76mm (T76), 92mm (T92), and 150mm (T150).

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 12 of 47

Installation
(1) Typical Suspended Concealed Ceiling Systems using TCR & FC Refer to figs 01 to 27 Locate position of trusses or purlins or concrete etc and based on the ceiling plan, mark the position of the suspension rod brackets (Peer product code C74 or C47-74) on it at 1200 mm centres maximum along supporting members. Fix the C74 or C47-74 suspension rod brackets as appropriate to the side of the steel purlins or bottom chord of the trusses with two self tapping screws in shear and to concrete with appropriate anchors. Cut all hanging rods (Peer product code C21) to the required length. Assemble adjustable suspension clip for TCR (Peer product code C60) on all these suspension rods. Install all of these rods (Peer product code C21) into the suspension rod brackets C47-74. Attach Top Cross Rails (Peer product code TCR25 or TCR38) to the suspension clips (Peer product code C60). Connect Furring Channels (Peer product code FC18 or FC28) to top cross rails TCR25 or TCR38 with locking keys (Peer product code C39). Check and adjust the ceiling system using a laser or other appropriate levelling device. Install ceiling lining boards as per manufacturers specification

Plasterboard

Hanger maximum distance from wall 300mm

Peer concealed ceiling framing

Fig 01 example of TCR/FC suspended ceiling

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 13 of 47

Installation contd
Peer top cross rail Fix Hangers a maximum of 300 mm from the wall C21 Peer suspension rod Peer furring channel C60 Peer suspension clip

1200mm max

Hanger maximum distance from wall 300mm

1200mm max 600mm max

Fig 02 example of suspension rod, anchors, FC and TCR


35mm plasterers angle or Peer T18 / T28 with bottom flange aligned with bottoms of furring channel and fixed to wall at ends and 600mm centres max.

Timber, steel or concrete support structure

End of top cross rail 10mm clear of wall for fire rating

1200mm max

Hanger maximum distance from wall 300mm

Furring channel spacing 600mm centres max

Top cross rail or Suspension rod spacing 1200mm centres max

Fig 03- suspended ceiling using C47-74/5mm rod/C60 combination

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 14 of 47

Installation contd
(1)Suspended Ceiling fixing of Furring Channels and TCR

Peer C21 suspension rod

Peer C60 suspension clip

Peer C39 Clip

Peer top cross rail Peer furring channel

Fig 04 Close up view FC18/28, C39, TCR25/38, C60 and Rod Combination

Adjustable TCR clip CTCR (7mm adjustment each notch)

Peer top cross rail

Peer furring channel

Peer C39 clip

Fig 05 Close up view of FC18/28, C39 and CTCR combination

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 15 of 47

Installation contd
Supporting member

Appropriate Anchor Concrete slab

Peer C47-74 Note: 2 screw fixings in shear Note: 2 screw fixings in shear

Peer C21-suspension rod

Fig 06 example of C47-74/Rod suspension system


Concrete

Steel Framing

Timber Framing

Appropriate anchor

Peer C47-74 clip

Peer C21 suspension rod Peer C47-74 fastened to timber framing/steel purlin with 2 screws in shear Peer C39 clip Peer C60 suspension clip Peer C60 suspension clip Peer top cross rail TCR

Peer furring channel

Fig 07 side view Rod/C60 suspension system with TCR25/38, C39/FC18 or 28

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 16 of 47

Installation contd
Peer Industries C79S multidirectional clip was designed specifically to make building a non standard (square or rectangular) ceiling easy The C79S clip is a multidirectional clip that will allow 360 degree rotation of furring channel to top cross rail. This clip has been specifically designed to address the problems
Fig 08 End view C79S multidirectional clip

encountered in the construction of irregularly shaped non square or rectangular ceilings. The use of this clip will simplify the construction of difficult ceilings and result in significant saving in construction time The C79S clip has been extensively load tested and complies with all relevant standards.

Fig 09 C79S multidirectional (Swivel) clip with TCR/FC

The C79S is manufactured from the highest quality corrosion resistant zinc plated steel available and is covered by Peer industries standard product warranty.
Peer top cross rail Peer furring channel

Fig 10 C79S multidirectional (Swivel) clip with TCR/FC

Peer 79S Multidirectional

Fig 11 C79S multidirectional (Swivel) clip with TCR/FC

Fig 12 Irregular shape room layout using the C79S clip

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 17 of 47

Installation contd
Steel or timber framing

Note: 2 screw fixings in shear

Peer C66 clip

Peer top cross rail

Peer C39 clip

Peer furring channel

Fig 13 Direct Fixing using C66 to Top Cross Rail 25/38mm then C39 to Furring Channel 18mm or 28mm

(2)Direct Fixing of Furring Channels Refer to figs 14, 15 and 16 Locate the position of floor joists or purlins or concrete etc and based on the ceiling plan; mark the position of the direct fix clips (Peer product code C26-80 or C26-180) on it. Fix the direct-fix clips C26-80 or C26-180 to the steel purlins or timber joists with two screws in shear and to concrete with appropriate anchors. Connect the furring channels FC18 or FC28 to the direct-fix clip C26. Check and adjust concealed ceiling system using a laser or other appropriate levelling device. Install ceiling board as per manufacturers specification

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 18 of 47

Installation contd

Steel or timber framing

Note: 2 screw fixings in shear

Peer C26-80 or C26-180 clip

Peer furring channel

Fig 14 Direct fixing using C26-80 to furring channel 18 or 28mm

Timber or steel supporting member

Peer furring channel

Peer C26-80 or C26-180 clip

Fig 15 Direct fixing using C26-80 to furring channel 18 or 28mm

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 19 of 47

Installation contd

Steel framing member

Timber framing member

Peer C26-80 or C26-180 fastened to timber with 2 screws

Peer C26-80 or C26-180 fastened to steel framing with 2/10x16 TEX screws (or equivalent)

Peer furring channel

Plasterboard

Fig 16 - Direct fixing system typical section.

(3) Drop Ceiling

Drop ceilings are required to allow for ducting, mechanical and electrical services, or as a feature with maximum of 600 mm drop Locate the position of the drop ceiling and mark the position of suspension rod Brackets (Peer product code C74 or C47-74) as per detail on trusses, purlins or concrete based on the ceiling plan. Join top cross rails TCR25 or TCR38 to suit site situation as per detail. Alternatively join furring channel FC18 or FC28 to suit site situation as per detail in Fig 17. Install suspension rod brackets C74 or C47-74, suspension rods C21, top cross rails TCR25 or TCR38 and furring channels FC18 or FC28 as per typical suspended concealed ceiling system. Check and adjust drop ceiling and concealed ceiling system using a laser or other suitable levelling device. Install ceiling lining board as per manufacturers specification

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 20 of 47

Installation contd
Roofing or floor

Note: 2 screw fixings in shear

Peer C47-74 clip

Note: 2 screw fixings in shear

Peer C60 clip

Galvanised angle, C88 clip or screws Peer top cross rail 2 Screws 2 Screws Peer C39 clip C39 clip

Galvanised angle, C88 clip or screws

P90INT angle if required

P90INT angle if required Peer C21 Suspension rod

Galvanised angle, C88 clip or crews

Peer furring channel 18 or 28mm

Peer C60 clip

2 Screws

600mm maximum

600mm maximum 2 Screws

P90EX angle if required P90EX angle if required

Parallel to Furring Channel

Parallel to Top Cross Rail

Fig 17 - Drop Ceiling details

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 21 of 47

Installation contd
(4) Fire Rated Ceiling Install concealed ceiling system as above with fire rating requirement. For fire rating ceiling, use the ceiling board manufacturers specification and recommendations on installation. Provide a 20mm gap at the ends of both top cross rails TCR25 or TCR38 and furring channels FC18 or FC28 for fire rating requirements as per board manufacturers specifications and recommendations on installation.

Timber, steel or concrete support structure

Top cross rail span or suspension rod spacing 1200mm max End of top cross rail 20mm clear of wall for fire rating

35mm plasterers angle or Peer T18 / T28 with bottom flange aligned with bottoms of furring channel and fixed to wall at ends and 600mm centres max.

Furring channel spacing 600mm centres max

Top cross rail spacing 1200mm centres max

300mm from wall

Fig 18 - Typical concealed ceiling framing drawing

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 22 of 47

Installation contd
(5) Acoustic (STC) Ceiling C001, C001-SUS, CFCRESAM,CTCRRES and FC Resilient Mounts

C001

CFCRESAM

C79SRES

CTCRRES

Supporting members, timber or steel to be spaced at a maximum of 1200 mm centres. Locate the resilient mounts product no. C001 at maximum 600mm centres along supporting members. Fasten using appropriate fasteners dependant on the weight of the plasterboard being used. Locate the furring channel product no. FC18 or FC28 in the resilient mounts C001 Locate short lengths of furring channel FC18 or FC28 to support butt joins in second layer of ceiling lining or as per board suppliers specification.

Timber or steel supporting member

Peer C001 resilient mount clip

Butt joint support

1200mm max centres

600mm max centres

Furring channel

Fig 19 Acoustic Ceiling using C001

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 23 of 47

Installation contd
(6) Typical Concealed Ceiling System - Ceiling Joists
Refer to Fig 20

Electrical, mechanical and plumbing services can make suspended ceiling systems difficult to install. The height of a project can also render the installation of a suspended ceiling system uneconomical. To solve this problem Peer steel studs can be used as ceiling framing members in areas such as corridors and bathrooms. Refer to span table CS-01 for ceiling joist sizes and spacing.

Mark position of tracks at ceiling level on wall as per working drawings. Fix these perimeter tracks with appropriate fasteners close to stud (ceiling joist location) at 600 mm maximum centres. Cut the studs to required length. Fit the studs in to the tracks. Provide and fix bridging members at the location as per table CS-01 Install ceiling lining board as per manufacturers specification.

Peer track

Peer bridging stud or track

Screws Peer track

Fixing of track to wall Peer wall stud

Fig 20 - Typical concealed ceiling system Ceiling Joists

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 24 of 47

Installation contd
(7) Curved and Raked Ceiling Curved or raked ceilings are to be provided wherever required by an architect or project designer for decorative purpose to suit site/project specification.

Roofing or flooring Purlin or Rafter

Peer C47-74 clip

Bracing

2 Screws in shear

NOTE: Refer to plasterboard specification for spacing of furring channel to suit radius Peer C21 suspension rod

Radius

Peer C60 clip

Peer top cross rail Plasterboard Peer furring channel Screw through TCR and C39 clip Caulk all perimeter joins with cornice adhesive Peer C39 clip Appropriate Screw

Fig 21- Typical Section Curved Ceiling (non fire rated)

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 25 of 47

Installation contd

Framing member

Peer C47-74 clip Note: 2 screw fixings in shear

Peer C21 suspension rod

Peer C60 clip Peer top cross rail

Angle cleat

Screw through TCR and C39 clip

Peer C39 clip

Continuous angle 0.75 BMT galv MS 50mm min leg length Peer furring channel

Appropriate Screw

600mm max

Plasterboard 200mm max Appropriate Screw Tape and set joint

Fig 22 - Normal ceiling Joint type A

Framing member

Angle cleat

Peer C47-74 clip Appropriate Screws in shear Peer C21 suspension rod

Continuous angle 0.75 BMT galv MS 50mm min leg length Peer C60 clip

Screw through TCR and C39 clip

Peer top cross rail

Peer C39 clip Peer furring channel

Plasterboard 200mm max

Fig 23 - Normal ceiling Joint type B

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 26 of 47

Installation contd
Curved Ceiling Install curved TCR25 top cross rail as per ceiling framing plan and in accordance with the above ceiling installation details and appropriate bracing with brace.

Install FC28 furring channels at a spacing to suit the radius of the curved ceiling with Peer furring channel to top cross rail C39 (locking key) clips Secure the C39 to the TCR with a screw fastener to prevent slipping. Refer to plasterboard specification of curved ceiling for spacing of furring channels. Raked Ceiling Install TCR38 top cross rail in raking position as per ceiling framing plan and in accordance with the above ceiling installation details and appropriate bracing. Install FC28 furring channels at spacing to suit ceiling lining thickness with Peer furring channel to top cross rail C39 (locking key) securing the C39 to the TCR with a screw fastener. Refer to plasterboard specification for spacing of furring channels.

Lining to Ceiling Frame


Plasterboard Installation Cut the plasterboard sheets to size. Position the sheet with the recessed edge at right angles to the framing member. Press sheet firmly against the adhesive (if it is to be used - see manufacturers specifications) and fasten at the centre line of the sheet on every framing member as shown in fig 07. Use full sheets. Saw cut sheets around openings. Butt joints must be staggered and not in a straight line across the ceiling. All plasterboard installation should be in accordance with AS 2588 & AS 2589 and the manufacturers specifications.

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 27 of 47

Installation contd
Plasterboard

Peer concealed ceiling framing

Fig 24 Plaster board installation

Other Building Board Installation: All building board installation should be in accordance with the manufacturers specification and recommended installation methods. Expansion and Control Joints: Expansion joints as well as control joints must coincide with those structural control joints provided in the main structure. Control joints shall be provided in long continuous ceiling at 12 metres maximum spacing. Refer to Figs 25, 26 and 27 for control joint at perimeter, parallel to furring channel and perpendicular to furring channel. Storage and Site Handling: Where possible all material used in the construction of steel ceiling framing should be handled in a manner that reduces the risk of damage. All material should be kept in a dry area so accidental damage cannot occur.

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 28 of 47

Installation contd Examples of various ceiling system control joints

6mm Gap

Plasterboard

Wall angle trim

Fig 25 - Ceiling to Wall Control Joint At Wall End

Plasterboard Peer furring channel 50mm max

Peer PXJ30 plasterboard expansion joint (runs parallel to the Furring Channel)

Fig 26 - Ceiling Control Joint Parallel to Furring

Plasterboard Peer furring channel

15mm max

Peer PXJ30 plasterboard expansion joint (perpendicular to the Furring Channel)

Fig 27 - Ceiling Control Joint Perpendicular to Furring Channel

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 29 of 47

Design Notes
Span tables are prepared for the use of top cross rails, furring channels, top hats and ceiling battens that are manufactured by Peer Industries Pty Ltd. Tables are based on permissible stress loading calculated as per AS1538 - 1988 Cold Formed Steel Structures Code AS2785 - 1985 Suspended Ceilings Design and Installation Deflection = As specified under tables Yield stress = 300 Mpa Section properties are based on the full section, using the nominal section dimensions notations which are in accordance with AS 1538. Refer to the sectional properties tables for full details of all products All information contained in this brochure is intended as a general guide only for use in ceiling framing construction. For use in any other design and construction or for any special structure, please contact Peer Design by email design@01Peer.com Call one of our customer service centres on 1300 725 675 or visit our web site www.peerindustries.com.au Almost all structures will deflect during service. Ceiling designers should be aware of the expected deflections of the building structures as they affect the ceiling. These deflections may be due to both dead and live loadings. In fire rated ceiling framing, thermal expansion of steel frames should be expected during fire service. Designer should make due allowances for these effects. The ceiling designer should properly consider framing design and layout around openings in ceiling systems. Ceiling spans are determined by various design criteria including: weight of ceiling, wind loading, deflection limits, material size and required spacings. For span information to satisfy specific design criteria contact Peer Design. Some examples detailing various component scenarios have been provided to assist in the choice of the correct product for most building projects.

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 30 of 47

CEILING JOIST - Single Span Wall Studs Lipped Internal Pressure 0.25 kPa

SPAN TABLE CCS01

Stud Size mm

Thickness BMT mm 10mmPlaster board (0.09 kN/M2)


600 450 300

Maximum Span in mm
13mmPlaster board (0.12 kN/M2) Stud Spacing in mm
600 450 300

16mmPlaster board (0.15 kN/M2)


600 450 300

0.50 64 0.75 1.15 0.55 76 0.75 1.15 0.55 92 0.75 1.15 150 0.75 1.15 Based on: Deflection = S/360.

2080 2430 2795 2385 2785 3165 2870 3215 3655 4395 4860

2280 2670 3060 2710 3055 3460 3145 3520 3900 4695 5180

2595 3035 3465 3080 3470 3825 3575 3890 4270 5135 5645

2025 2370 2720 2335 2710 3085 2790 3130 3575 4310 4765

2220 2600 2980 2635 2970 3370 3065 3430 3830 4605 5085

2525 2960 3380 3000 3380 3755 3485 3815 4190 5045 5550

1975 2310 2655 2290 2640 3010 2720 3050 3515 4230 4685

2165 2535 2910 2575 2895 3290 2985 3345 3760 4525 5000

2465 2885 3300 2925 3295 3690 3400 3745 4120 4955 5460

Spans are as per AS1538 & AS2785. Bridging: 0 - 2500mm span = No Bridging. 2500 - 4000mm span = One row of Bridging. 4000 - 6000mm span = Two rows of Bridging.

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 31 of 47

Span Table - TH50-115 Top Hat

SPAN TABLE CCS02 Ceiling Installation

Top Hat Section TH50-115 = 20x35x50x35x20 x1.15 mm

Lateral Pressure

MAXIMUM TOP HAT SPAN mm Single Span Double Spans Continuous Spans

Permissible kPa

Ultimate Limit State

Top Hat Spacing in mm


600 450 600 450 600 450

0.75 1.00 1.50 2.00 2.50 3.00 4.00 5.00 6.00 Based on: Deflection = span/360. Critical of Strength & deflection

1.12 1.50 2.25 3.00 3.75 4.50 6.00 7.50 9.00

1485 1350 1175 1070 995 935 850 790 740

1635 1485 1295 1175 1095 1030 935 870 815

1990 1810 1580 1385 1240 1130 980 875 800

2190 1990 1740 1580 1430 1305 1130 1010 920

1835 1665 1455 1325 1230 1155 1050 975 890

2020 1835 1600 1455 1350 1270 1155 1075 1010

As per AS1538 and AS4600 - Cold Formed Steel Structures Code. Permissible stress design and ultimate loads.

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 32 of 47

Span Table TH75-115 Top Hat

SPAN TABLE CCS03 Ceiling Installation

Top Hat Section TH75-115 = 20x35x75x35x20 x1.15 mm

Lateral Pressure

MAXIMUM TOP HAT SPAN mm Single Span Double Spans Continuous Spans

Permissible kPa

Ultimate Limit State

Top Hat Spacing in mm


600 450 600 450 600 450

0.75 1.00 1.50 2.00 2.50 3.00 4.00 5.00 6.00 Based on: Deflection = span/360. Critical of Strength & deflection.

1.12 1.50 2.25 3.00 3.75 4.50 6.00 7.50 9.00

1570 1425 1245 1130 1050 990 900 835 785

1725 1570 1365 1245 1155 1085 990 920 865

2095 1905 1660 1470 1310 1190 1035 920 840

2305 2095 1830 1660 1510 1380 1190 1065 975

1935 1760 1540 1395 1300 1220 1080 970 850

2135 1935 1690 1540 1430 1345 1220 1100 1000

As per AS1538 and AS4600 - Cold Formed Steel Structures Code. Permissible stress design and ultimate loads.

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 33 of 47

Span Table TH60-075 Top Hat

SPAN TABLE CCS04

Location on Wall Wind Classification N1 N2 N3 N4 N5 C1 C2 C3 C4 Location on Wall Wind Classification N1 N2 N3 N4 N5 C1 C2 C3 C4 Location on Wall Wind Zone LOW MEDIUM HIGH VERY HIGH Location on Wall Wind Zone LOW MEDIUM HIGH VERY HIGH

MAXIMUM TOP HAT SPAN - SINGLE SPAN INSTALLATION


General Zone
300MM Spacing 450MM Spacing 600mm Spacing 300MM Spacing

Edge Zone
450MM Spacing 600mm Spacing

MAXIMUM TOP HAT SPAN - DOUBLE SPAN INSTALLATION


General Zone
300MM Spacing 450MM Spacing 600mm Spacing 300MM Spacing

2300 2300 2000 1650 1400 1750 1450 1200 1000

2000 2000 1650 1350 1100 1500 1150 950 850

1850 1800 1450 1200 950 1250 1000 850 750

2050 1950 1650 1400 1150 1500 1200 1000 850

1750 1700 1400 1150 950 1200 100 800 700

1600 1500 1200 1000 800 1050 850 700 600

Edge Zone
450MM Spacing 600mm Spacing

MAXIMUM TOP HAT SPAN - SINGLE SPAN INSTALLATION


General Zone
300MM Spacing 450MM Spacing 600mm Spacing 300MM Spacing

2800 2450 2050 1700 1400 1750 1450 1200 1000

2350 2050 1700 1400 1150 1450 1150 950 850

2100 1850 1500 1200 1000 1250 1000 850 700

2400 2100 1650 1350 1100 1450 1200 950 850

2000 1700 1350 1100 900 1150 950 800 700

1750 1450 1150 950 800 1000 850 700 600

Edge Zone
450MM Spacing 600mm Spacing

MAXIMUM TOP HAT SPAN - DOUBLE SPAN INSTALLATION


General Zone
300MM Spacing 2950 2550 2250 2050 450MM Spacing 2450 2200 1950 1700 600mm Spacing 2200 1950 1700 1500 300MM Spacing 2600 2250 1900 1650

2700 2450 2200 2000

2350 2150 1900 1650

2150 1950 1650 1450

2350 2100 1800 1650

2000 1800 1600 1400

1800 1600 1400 1200

Edge Zone
450MM Spacing 2100 1850 1550 1350 600mm Spacing 1850 1600 1350 1150

Notes 1. Material is 0.75 BMT and G300 2. Double span installation assumes that the 2 spans are approximately equal 3. If spans differ by more than 25% the use the single span table

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 34 of 47

Span Table FCDB 16mm Batten


Ceiling Installation

SPAN TABLE CCS05

Plasterboard

MAXIMUM SPAN in mm Continuous Span


600 450

10 mm Plasterboard (7 kg/m2) 13 mm Plasterboard (10 kg/m2) Based on:

1050 1000

1150 1100

AS 3623, Serviceability = Span/600 for G only. AS 1170.2 2002, Serviceability = Span/200 for G + Ws. AS 3623, Ultimate Strength for 1.25G. AS1170.2-2002, Ultimate Strength for 1.2G + Wu. Wind Loads as per AS 4055. G550 and t = 0.38mm. As per AS 4600 - Cold Formed Steel Structures Code.

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 35 of 47

TCR SPAN TABLE CCS06


Top Cross Rail spacing in mm 750 900 1000 1200 Top Cross Rail spacing in mm 750 900 1000 1200 Top Cross Rail TCR25 - Wind Category N2 Span of Top Cross Rail = 900mm Span of Top Cross Rail = 1200mm Furring channel spacing Furring channel spacing 450 600 450 600 FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 Allowable ceiling weight in kg/sqm 86 86 70 86 36 36 36 36 54 71 41 71 28 28 28 28 40 62 30 62 23 23 23 23 23 47 17 45 14 14 14 14 Top Cross Rail TCR38 - Wind Category N2 Span of Top Cross Rail = 900mm Span of Top Cross Rail = 1200mm Furring channel spacing Furring channel spacing 450 600 450 600 FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 Allowable ceiling weight in kg/sqm 94 173 70 148 94 100 70 100 54 143 41 107 54 79 41 79 40 104 30 78 40 68 30 68 23 60 17 45 23 52 17 45

Tables provide the maximum allowable ceiling weight in kg/sqm , supported by Peer framing. Ultimate wind pressure on ceiling = 0.29 kPa. Serviceability wind pressure on ceiling = 0.12 kPa. Figures in italics indicate strength is critical elsewhere, deflection is critical.

Shaded means that FC is critical

TCR SPAN TABLE CCS07


Top Cross Rail spacing in mm 750 900 1000 1200 Top Cross Rail spacing in mm 750 900 1000 1200 Top Cross Rail TCR25 - Wind Category N3 Span of Top Cross Rail = 900mm Span of Top Cross Rail = 1200mm Furring channel spacing Furring channel spacing 450 600 450 600 FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 Allowable ceiling weight in kg/sqm 77 77 70 77 25 25 25 25 54 58 41 58 14 14 14 14 40 48 30 48 9 9 9 9 23 33 0 33 0 0 0 0 Top Cross Rail TCR38 - Wind Category N3 Span of Top Cross Rail = 900mm Span of Top Cross Rail = 1200mm Furring channel spacing Furring channel spacing 450 600 450 600 FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 Allowable ceiling weight in kg/sqm 94 165 70 136 86 86 70 86 54 131 41 107 54 65 41 65 40 104 30 78 40 54 30 54 23 60 0 45 23 38 0 38

Tables provide the maximum allowable ceiling weight in kg/sqm , supported by Peer framing. Ultimate wind pressure on ceiling = 0.45 kPa. Serviceability wind pressure on ceiling = 0.18 kPa. Figures in italics indicate strength is critical elsewhere, deflection is critical.

Shaded means that FC is critical

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 36 of 47

TCR SPAN TABLE CCS08


Top Cross Rail spacing in mm 750 900 1000 1200 Top Cross Rail spacing in mm 750 900 1000 1200 Top Cross Rail TCR25 - Wind Category N4 Span of Top Cross Rail = 900mm Span of Top Cross Rail = 1200mm Furring channel spacing Furring channel spacing 450 600 450 600 FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 Allowable ceiling weight in kg/sqm 59 59 59 59 7 7 7 7 39 39 39 39 0 0 0 0 29 29 26 29 0 0 0 0 0 14 0 14 0 0 0 0 Top Cross Rail TCR38 - Wind Category N4 Span of Top Cross Rail = 900mm Span of Top Cross Rail = 1200mm Furring channel spacing Furring channel spacing 450 600 450 600 FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 Allowable ceiling weight in kg/sqm 94 147 70 118 67 67 67 67 54 112 41 88 46 46 41 46 40 95 26 67 36 36 26 36 0 58 0 28 0 20 0 20

Tables provide the maximum allowable ceiling weight in kg/sqm , supported by Peer framing. Ultimate wind pressure on ceiling = 0.67 kPa. Serviceability wind pressure on ceiling = 0.27 kPa. Figures in italics indicate strength is critical elsewhere, deflection is critical.

Shaded means that FC is critical

TCR SPAN TABLE CCS09


Top Cross Rail spacing in mm 750 900 1000 1200 Top Cross Rail spacing in mm 750 900 1000 1200 Top Cross Rail TCR25 - Wind Category C1 Span of Top Cross Rail = 900mm Span of Top Cross Rail = 1200mm Furring channel spacing Furring channel spacing 450 600 450 600 FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 Allowable ceiling weight in kg/sqm 33 33 33 33 0 0 0 0 13 13 13 13 0 0 0 0 0 3 0 3 0 0 0 0 0 0 0 0 0 0 0 0 Top Cross Rail TCR38 - Wind Category C1 Span of Top Cross Rail = 900mm Span of Top Cross Rail = 1200mm Furring channel spacing Furring channel spacing 450 600 450 600 FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 Allowable ceiling weight in kg/sqm 94 121 66 92 41 41 41 41 54 86 20 62 20 20 20 20 0 69 0 42 0 10 0 10 0 32 0 3 0 0 0 0

Tables provide the maximum allowable ceiling weight in kg/sqm , supported by Peer framing. Ultimate wind pressure on ceiling = 0.98 kPa. Serviceability wind pressure on ceiling = 0.40 kPa. Figures in italics indicate strength is critical elsewhere, deflection is critical.

Shaded means that FC is critical

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 37 of 47

TCR SPAN TABLE CCS10


Top Cross Rail spacing in mm 750 900 1000 1200 Top Cross Rail spacing in mm 750 900 1000 1200 Top Cross Rail TCR25 - Wind Category C2 Span of Top Cross Rail = 900mm Span of Top Cross Rail = 1200mm Furring channel spacing Furring channel spacing 450 600 450 600 FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 Allowable ceiling weight in kg/sqm 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Top Cross Rail TCR38 - Wind Category C2 Span of Top Cross Rail = 900mm Span of Top Cross Rail = 1200mm Furring channel spacing Furring channel spacing 450 600 450 600 FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 Allowable ceiling weight in kg/sqm 76 80 26 51 1 1 0 0 0 46 0 22 0 0 0 0 0 29 0 2 0 0 0 0 0 0 0 0 0 0 0 0

Tables provide the maximum allowable ceiling weight in kg/sqm , supported by Peer framing. Ultimate wind pressure on ceiling = 1.45 kPa. Serviceability wind pressure on ceiling = 0.59 kPa. Figures in italics indicate strength is critical elsewhere, deflection is critical.

Shaded means that FC is critical

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 38 of 47

Furring Channel Cyclonic Batten FCCB (0.38 BMT G550) Tables allow for maximum ceiling board load on ceiling battens

SPAN TABLE CCS11

Wind Loading N2- W33N


Continuous over Three spans
Continuous Span of Ceiling batten 900 Spacing of ceiling Batten 600
Weight of Ceiling Board in Kg/sqm

1200 Spacing of ceiling Batten 600 8.5 450 12.5

450 40

29

Based on: Weight of board in kg/sqm Ultimate wind pressure Wu = 0.29 kPa Serviceability wind pressure Ws = 0.12 kPa Deflection criteria- G = S/600 & G + Ws = S/200 As per AS4600, AS 2785, AS1170 & AS3623

Wind Loading N3-W41N


Continuous over Three spans
Continuous Span of Ceiling batten 900 Spacing of ceiling Batten 600 Weight of Ceiling Board in Kg/sqm 450 1200 Spacing of ceiling Batten 600 450

24

40

---

12.5

Based on: Weight of board in kg/sqm Ultimate wind pressure Wu = 0.45 kPa Serviceability wind pressure Ws = 0.18 kPa Deflection criteria- G = S/600 & G + Ws = S/200 As per AS4600, AS 2785, AS1170 & AS3623

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 39 of 47

CLIP CAPACITY TABLE CCS 12


Peer clip capacity based on testing by ETRS Report No. 4206-2014/1 21/12/2006. & 4206-2014/3 05/04/2007 and 4206-2014/4-08/06/2007 These capacities are maximum allowable as per AS2785 2000 and 1985 Limit state design capacity is for AS2785 2000 Suspended Ceilings Design and Installation Working load is for AS2785 1985 Suspended Ceilings Design & Installation. Working load Weight on boards on clip In Kgs 82 177 53 48 48 68 66 53 58 99 52 51 95 92 92 92 64 46 54 30 68 32 32 16 37 32 29 34 89 63 74 74 75 79 70

Part number C001 C001-DCS C001-SUS C26-80 C26-180 C37-7H C37-M6 C39 C42 C47-74 C74 C52 C54 C60 C60DF C60LDF C61S Constrained C61S Not Constrained C79S C85 C409 CDB26-80 CDB26-150 CBET.FIX First tooth CBET.FIX Last tooth CFCAM First tooth CFCRESAM First tooth CFCRESAM Last tooth CFCSAM CTCR-100 CTCRRES-100 Last tooth C24 Suspended C24 Hard bolted C66 C001

Limit Sate design capacity In kN 1.45 3.13 0.94 0.85 0.85 1.20 1.17 0.94 1.02 1.75 0.93 0.90 1.68 1.64 1.64 1.64 1.13 0.81 0.95 0.53 1.20 0.57 0.57 0.29 0.67 0.57 0.52 0.62 1.59 1.13 1.32 1.31 1.34 1.40 1.25

NOTE:

Limit state capacity less than 0.50 kN or Working load less than 25 kgs do not use that clip at that particular location.
(Refer to Shaded area CBET-FIX do not use the first tooth of the clip to support furring channel)

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 40 of 47

SECTIONAL PROPERTIES TABLE No. SP-01 FCDB 16mm Ceiling Batten

Peer Part No

Thickness t mm BMT

Shear Centre YS mm

Centroid

Area

Second Moment of Area IX-X x 103 mm4 1.154 IY-Y x 103 mm4 5.63

Section Modulus ZX-X mm3 ZY-Y mm


3

Radius of Gyration Rx mm Ry mm

XC mm

YC mm

A mm2

FCDB16

0.38

8.26

17.485

5.52

28.64

107

326

6.35

14.02

Section properties calculated in accordance with AS 1538 and AS 4600 - Cold Formed Steel Structures Code. Material Specification: Peer sections are roll formed from zinc coated steel strip which conforms to AS 1397. Zincalume G550 AZ150, Yield Strength - Fy = 550 Mpa & Coating Grade AZ150 g/m2 zinc/alum.

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 41 of 47

SECTIONAL PROPERTIES TABLE No. SP-02 FCCB 22mm Ceiling Batten

Peer Part No

Depth

Width

Thickness

Shear Centre

Centroid

Yield Strength

Area

Mono symmetry Section Constant

D mm FCCB22 21.0

B mm 30

t mm BMT 0.38

YS mm 6.75

XC mm 33. 0

YC mm 10. 66

FY MPa 550

A mm2 49.9

x mm 59.6

Peer Part No

Torsion Constant

Second Moment of Area

Section Modulus

Radius of Gyration

Form Factor

Warping Constant

J mm4 FCCB22 3.83

IX-X x 103 mm4 3.62

IY-Y x 103 mm4 20.12

ZX-X mm3 339

ZY-Y mm3 610

Rx mm 8.51

Ry mm 20.1

Iw x 106 mm4 0.71

0.892

Section Properties calculated in accordance with AS 1538 and AS 4600 - Cold Formed Steel Structures Code. Material Specifications: Peer sections are roll formed from zinc coated steel strip which conforms to AS 1397. Zincalume G550 AZ150, Yield Strength - Fy = 550 Mpa & Coating Grade AZ150 g/m2 zinc/alum.

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 42 of 47

SECTIONAL PROPERTIES TABLE SP-03 Furring Channel FC18 and FC28mm Section Properties

Peer Part No

Dept h

Width

Thickness

Shear Centre

Centroid

Yield Strength

Area

Second Moment of Area IX-X x 103 mm4 2.41 7.01 IY-Y x 103 mm4 14.77 18.29

D mm FC18 FC28 18 28

B mm 38 38

t mm BMT 0.42 0.42

YS mm 6.32 10.7

XC mm 25.7 25.7

YC mm 8.73 13.6

FY MPa 550 550

A mm2 50.0 60.0

Peer Part No

Torsion Constant

Mono symmetry Section Constants

Section Modulus

Radius Of Gyration

Form Factor

Warping Constant

J mm4
FC18 FC28

X mm 43 53

ZX-X mm3 260 487

ZY-Y mm3 575 712

Rx mm 6.94 10.8

Ry mm 17.2 17.5

Q 0.877 0.842

IW x 106 mm6 0.53 1.58

4.2 5.0

Section Properties calculated in accordance with AS 1538 and AS 4600 - Cold Formed Steel Structures Code. Material Specifications: Peer sections are roll formed from zinc coated steel strip which conforms to AS 1397. Zincalume G550 AZ150, Yield Strength - Fy = 550 Mpa & Coating Grade AZ150 g/m2 zinc/alum.

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 43 of 47

SECTIONAL PROPERTIES TABLE SP-04 Top Cross Rail TCR25 and TCR38mm Section Properties

Peer Part No

Depth

Width

Thickness

Shear Centre

Centroid

Yield Strength

Area

D mm

B mm

t mm BMT 0.75 0.75


Second Moment of Area

YS mm

XC mm

YC mm

FY MPa

A mm2

TCR25 TCR38
Peer Part No

25.4 38.3
Torsion Constant

22.83 22.83

14.4 21.8

11.415 11.415

11.9 18.35

300 300

67.5 87
Form Factor

Section Modulus

Radius of Gyration

J mm4 TCR25 TCR38 12.7 16.3

IX-X x 103 mm4 5.37 15.55

IY-Y x 103 mm4 3.91 4.70

ZX-X mm3 397 779

ZY-Y mm3 343 411

Rx mm 8.92 13.37

Ry mm 7.61 7.35

Q 1.0 1.0

Section Properties calculated in accordance with AS 1538 and AS 4600 - Cold Formed Steel Structures Code Material Specifications: Peer sections are roll formed from zinc coated steel strip which conforms to AS 1397. Material: G2 Z275, Yield Strength - Fy = 300 Mpa and coating grade Z275 (275 g / m2 zinc).

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 44 of 47

SECTIONAL PROPERTIES TABLE SP-05 TH75-115, TH50-115 Top Hats - Section Properties

Peer Part No

Depth

Width

Thick -ness

Shear Centre

Centroid

Yield Strength

Area

Second Moment of Area IX-X x 103 mm4 40.8 34.6 IY-Y x 103 mm4 236.8 107.7

D mm TH75-115 TH50-115 35 35

B mm 75 50

t mm BMT 1.15 1.15

YS mm 14.9 13.3

XC mm 56.4 43.9

YB mm 20.8 18.6

YT mm 14.2 16.4

FY Mpa 300 300

A mm2 203.8 174.6

Peer Part No

Torsion Constant

Mono symmetry Section Constants Y mm 108.9

Section Modulus

Radius of Gyration

Form Factor

Warping Constant

J mm4 TH75-115 89.7

ZXXT mm3 2882

ZXXB mm3 1956

ZY-Y mm3 4202

Rx mm 14.2

Ry mm 34.1

IW x 106 mm6 23.23

0.884

TH50-115

77.0

86.2

2112

1859

2455

14.1

24.5

0.946

9.59

Section Properties calculated in accordance with AS 1538 and AS 4600 - Cold Formed Steel Structures Code Material Specifications: Peer sections are roll formed from zinc coated steel strip which conforms to AS 1397. Material: G2 Z275, Yield Strength - Fy = 300 Mpa and coating grade Z275 (275 g / m2 zinc).

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 45 of 47

Notes

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 46 of 47

Notes

Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual

Page CCS 47 of 47