Documente Academic
Documente Profesional
Documente Cultură
PERFORMANCE RANGE
APPLICATION LIMITS
Manometric suction lift up to 9 m (HS) Liquid temperature between -10 C and +90 C Temperature of diesel up to +55C Ambient temperature up to +40 C Max. working pressure 6 bar Continuous service S1
CERTIFICATIONS
CK-INT pump with switch and power cable complete with Schuko plug CKm 50-BP/NZ pump with aluminium trigger dispensing nozzle and 4 metre long spiral reinforced hose. Special mechanical seal Other voltages or 60 Hz frequency IP 55 class protection
GUARANTEE
1 year subject to terms and conditions
128
50 Hz
Head H (metres)
Flow rate Q
MODEL Single-phase Three-phase CKm 50 CKm 50-BP CKm 80E CKm 90E CK 50 CK 50-BP CK 80E CK 90E
m/h l/min
0 0 35
0.3 5 31 20 46 49
0.6 10 27 20 42 45
0.9 15 24 20 38 41
1.2 20 20 20 34 37
1.5 25 16 16.5 30 33
1.8 30 13 13 26 29
2.1 35 9 9 22 25
2.4 40 5 5 18 21
3.0 50
H metres
20 48 51
10 13
INSTALLATION EXAMPLE
Non-return valve
HS = Suction height
129
CK
POS. COMPONENT
1 2 3 4 5 PUMP BODY MOTOR BRACKET IMPELLER MOTOR SHAFT MECHANICAL SEAL
CONSTRUCTION CHARACTERISTICS
Cast iron, complete with threaded ports in compliance with ISO 228/1 Aluminium with brass insert (patented), reduces the risk of impeller seizure Brass, star type with open radial vanes Stainless steel EN 10088-3 - 1.4104 Seal
Model
Shaft
Diameter Stationary ring
Materials
Rotational ring Elastomer
AR-12V
12 mm
Ceramic
Graphite
Viton
BEARINGS
Pump CK 50 CK 50-BP CK 80 CK 90
CAPACITOR
Pump
Single-phase
Capacitance
(230 V or 240 V) (110 V)
ELECTRIC MOTOR
CKm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. CK: three-phase 230/400 V - 50 Hz. Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance Insulation: F class. Protection: IP 44.
130
i DN2
h2 DN1
h3
s a w m
h1
n1 n
MODEL Single-phase CKm 50 CKm 50-BP CKm 80E CKm 90E Three-phase CK 50 CK 50-BP CK 80E CK 90E
DIMENSIONS mm h3 153 i 75 m 80 n 120 n1 100 w 69 7 180 136 31 167 81 90 140 112 77 s 1~ 7.4 10.8 10.9
ABSORPTION
MODEL Single-phase CKm 50 CKm 50-BP CKm 80E CKm 90E 230 V 3.0 A 3.0 A 5.0 A 4.8 A VOLTAGE (single-phase) 240 V 2.9 A 2.9 A 4.8 A 4.4 A 110 V 6.2 A 6.2 A 9.8 A 9.4 A MODEL Three-phase CK 50 CK 50-BP CK 80E CK 90E 230 V 2.1 A 2.1 A 3.5 A 3.5 A VOLTAGE (three-phase) 400 V 1.2 A 1.2 A 2.0 A 2.0 A 690 V 0.7 A 0.7 A 1.2 A 1.2 A 240 V 2.0 A 2.0 A 3.4 A 3.4 A 415 V 1.2 A 1.2 A 2.0 A 2.0 A 720 V 0.7 A 0.7 A 1.2 A 1.2 A
PALLETIZATION