Sunteți pe pagina 1din 2

BAE SECURA OPzS solar

1. APPLICATIONS
Photovoltaic power supply of
- power plants of remote villages, huts in the mountains.
- signal installations of the air-, sea-, road- and railway transport
- radio relay stations of telecommunication services, cellular phone stations
Hybrid power supply (photovoltaic, wind generator and Diesel engine): In these cases the battery serves to buffer load peaks, to smooth the current
and to reduce the operation time of Diesel engines at low power demand.
2. TECHNICAL DATA
C 100

C 20

C 10

C5

C1

Ri

Ik

mass

dimensions

Ah

Ah

Ah

Ah

Ah

kA

kg

m x mm x mm

Ue 80%

1,91V

1,91V

1,90V

1,87V

1,74V

Ue 100%

1,80V

1,80V

1,80V

1,77V

1,67V

12V 1 OPzS 50

72

60

51

41,5

28,5

19,2

0,64

40

272 x 205 x 385

12V 2 OPzS 100

145

120

103

84

56,5

9,60

1,28

51

272 x 205 x 385

12V 3 OPzS 150

215

180

154

125

85

6,40

1,92

71

380 x 205 x 385

6V 4 OPzS 200

335

240

205

167

115

2,40

2,56

48

272 x 205 x 385

6V 5 OPzS 250

360

300

256

208

143

1,92

3,20

62

380 x 205 x 385

6V 6 OPzS 300

430

360

308

250

172

1,60

3,84

69

380 x 205 x 385

12V 1 OPzS 50 to 12V 3 OPzS 150

LxBxH

6V 4 OPzS 200 to 6V 6 OPzS 300

ENERGY FROM BATTERIES

Technical Specification of BAE OPzS solar


C 100

C 20

C 10

C5

page 2

C1

Ri

Ik

mass

dimensions

kA

kg

mm x mm x mm

Ah

Ah

Ah

Ah

Ah

Ue 80%

1,91V

1,91V

1,90V

1,87V

1,74V

Ue 100%

1,80V

1,80V

1,80V

1,77V

1,67V

4 OPzS 200

290

225

210

175

114

0,95

2,16

17,2

105 x 208 x 420

5 OPzS 250

370

305

270

220

143

0,76

2,70

20,8

126 x 208 x 420

6 OPzS 300

440

365

320

262

170

0,63

3,24

24,3

147 x 208 x 420

5 OPzS 350

550

455

400

336

205

0,70

2,90

26,9

126 x 208 x 535

6 OPzS 420

680

560

490

400

245

0,58

3,48

31,5

147 x 208 x 535

7 OPzS 490

790

650

570

470

285

0,50

4,06

36,1

168 x 208 x 535

6 OPzS 600

930

760

670

560

330

0,47

4,32

44,8

147 x 208 x 710

LxBxH

8 OPzS 800

1230

1020

890

740

440

0,35

5,76

61,3

215 x 193 x 710

10 OPzS 1000

1550

1280

1120

930

550

0,28

7,20

74,5

215 x 235 x 710

12 OPzS 1200

1860

1530

1340

1100

660

0,23

8,64

88

215 x 277 x 710

12 OPzS 1500

2350

1930

1690

1400

820

0,23

9,18

114,3

215 x 277 x 855

16 OPzS 2000

3130

2580

2250

1850

1100

0,17

12,2

151,5

215 x 400 x 815

20 OPzS 2500

3900

3220

2810

2300

1375

0,14

15,3

193,0

215 x 490 x 815

24 OPzS 3000

4700

3870

3380

2800

1640

0,11

18,4

234,5

215 x 580 x 815

4 OPzS 200 to 6 OPzS 600

8 OPzS 800 to 12 OPzS 1500

16 OPzS 2000

20 OPzS 2500 to 24 OPzS 3000

3. NUMBER OF CYCLES AS FUNCTION OF DOD (DEPTH OF DISCHARGE)


DOD

80%

70%

60%

50%

40%

30%

20%

10%

Cycles OPzS-cell

1500

1700

2000

2400

3000

4000

5000

10000

Cycles OPzS block

1200

1350

1600

1900

2400

3200

4000

8000

4. CAPACITY AS FUNCTION OF TEMPERATURE


temperature

20C

15C

10C

5C

0C

-5C

-10C

-20C

C100

100%

98%

94%

90%

85%

79%

72%

55%

5. Operation
At lower voltages as U80% the battery has to be disconnected to avoid a damage of the battery.
The charging current may vary from 5 x I10 to 0,01 x I10. The charging voltage has to be restricted to 2,30V to 2,40V.
At daily discharge below 0,2 C100

2,30V - 2,35V

At daily discharge above 0,2 C100 up to 0,3 C100

2,35V - 2,40V

At higher daily discharges a not acceptable electrolyte stratification occurs, if not regularly gassing charging is applied or BAE OPzS EU - cells (with
electrolyte agitation) are used.

BAE Berliner Batteriefabrik GmbH - Wilhelminenhofstrae 69 - D-12459 BERLIN


TEL +49 30 53001-0
Germany: TEL-687 FAX-336
Export: TEL-665 FAX -675

ENERGY FROM BATTERIES