Operating Voltage (SLC) 17~41 VDC Average Current Consumption 600uA (Typical) Alarm Current 8mA Ambient Temperature 32F (0 C) ~ 120F (49C) Maximum Humidity 90% RH, non-condensing Dimensions 3.4"W x 4.8"H x 2.0"D Mounting Single gang or 4" square electrical box

MODEL DESCRIPTION DCP-AMS DCP-AMS-KL


DCP-AMS DCP-AMS-LP DCP-AMS-KL DCP-AMS-KL-LP Single Action Hex Key Lock Dual Action Hex Key Lock Single Action Key Lock Dual Action Key Lock

DESCRIPTION
The DCP-AMS are the Hochiki America series of addressable manual pull stations that provide a fast and practical means of manually initiating a fire alarm signal. Both single action and dual action manual pull stations are available. Resetting of the pull station requires either a Cat 30 key or a 1/8" hex key (depending upon the model used). An alarm condition is actuated by pulling down on the handle of the DCP-AMS and DCP-AMS-KL single action models. On the dual action models DCP-AMS-LP and DCP-AMS-KL-LP the Lift and Pull cover must be lifted before pulling down on the pull station handle. Once the pull station is activated, the handle cannot be put back into a normal standby condition without using the key operated reset feature. The DCP-AMS series is electronically addressable and includes a bi-colored status LED. The LED blinks green indicating normal communication with the DCP compatible SLC loop. When an alarm condition is actuated by pulling the handle, the LED will latch Red to indicate the alarm condition.

DCP-AMS-LP

DCP-AMS-KL-LP

STANDARD FEATURES
Addressable integrated design All metal construction Single and dual action models available Extremely easy to operate Bi-colored status LED indicates Standby and Alarm conditions Address is programmable in EEPROM Address can be programmed when installed Key lock or hex key lock models available Terminals accept up to 14AWG wire Surface mount back box available ADA compliant (except LP models)
Specifications subject to change without notice.

PRODUCT LISTINGS
California State Fire Marshal
S6512

3033215

7150-0410:169
Continued on back.

Hochiki America Corporation 7051 Village Drive, Suite 100 Buena Park, CA 90621-2268 Phone: 714/522-2246 Fax: 714/522-2268 Technical Support: 800/845-6692 or technicalsupport@hochiki.com

Find latest revision at www.hochiki.com

F0066

07/2010

ENGINEERING SPECIFICATIONS
Manual pull stations shall be Hochiki addressable AMS-series single or dual action models, DCP-AMS, DCP-AMSKL, DCP-AMS-LP, or DCP-AMS-KL-LP. Models shall be made of 14 AWG CRS and painted with Red enamel. The words Fire Alarm shall be in a contrasting color and be embossed text 1/2" tall. The electronics shall be fully integrated into the manual pull station requiring only connection to the SLC loop of the control panel. Programming of the manual pull station address must be possible with the manual pull station fully installed. Manual pull stations shall be Underwriters Laboratories Inc. Listed, CSFM Approved, and be installed within the limits defined in the Americans With Disabilities Act.

WIRING DIAGRAMS
OUT TO NEXT MODULE

Hochiki America Corporation DCP-AMS


Addressable Manual Pull Station

Ser. No.

SC-

S+
S+
S6512
NON-CODED ALARM BOX 36CC

SC-

For Proper Installation, see HA-06-135 Rev 12/05

UL Listed + S Hochiki DCP - SC Compatible Panel


TYPICAL WIRING DIAGRAM EXAMPLE, CONNECTED TO A COMPATIBLE LISTED CONTROL PANEL

Class B (Style 4)
Hochiki America Corporation DCP-AMS
Addressable Manual Pull Station

Hochiki America Corporation DCP-AMS


Addressable Manual Pull Station

Hochiki America Corporation DCP-AMS


Addressable Manual Pull Station

Ser. No.

Ser. No.

Ser. No.

S+

SCS6512

For Proper Installation, see HA-06-135 Rev 12/05

S+

SCS6512

S+

SC-

For Proper Installation, see HA-06-135 Rev 12/05

For Proper Installation, see HA-06-135 Rev 12/05

+ S UL Listed - SC Hochiki DCP + S Compatible Panel - SC

S6512
NON-CODED ALARM BOX 36CC

NON-CODED ALARM BOX 36CC

NON-CODED ALARM BOX 36CC

Class A Return (Style 6) Class A (Style 7)


Hochiki America Corporation DCP-AMS
Addressable Manual Pull Station

Hochiki America Corporation DCP-AMS


Addressable Manual Pull Station

Ser. No.
For Proper Installation, see HA-06-063 Rev 2/02 For Proper Installation, see HA-06-063 Rev 2/02 For Proper Installation, see HA-06-063 Rev 2/02

Ser. No.
For Proper Installation, see HA-06-063 Rev 2/02

Hochiki America Corporation

Hochiki America Corporation

Hochiki America Corporation

LISTED SIGNALING DEVICE ISSUE NO. AH-9774

SER. NO. XXXXXXXXX

SER. NO. XXXXXXXXX

SER. NO. XXXXXXXXX

DCP-SCI

DCP-SCI

DCP-SCI

UL Listed Hochiki DCP Compatible Panel - SC

(IN) SC (OUT) S
S6512

S+

SC-

(IN) SC (OUT) S

(IN) SC (OUT) S
S6512

DCP-SCI

SER. NO. XXXXXXXXX

LISTED SIGNALING DEVICE ISSUE NO. AH-9774

LISTED SIGNALING DEVICE ISSUE NO. AH-9774

LISTED SIGNALING DEVICE ISSUE NO. AH-9774

(IN) S

(IN) S

(IN) S

Hochiki America Corporation

S SC
S5694

(IN) S (IN) SC (OUT) S

S+

SC-

For Proper Installation, see HA-06-135 Rev 12/05

For Proper Installation, see HA-06-135 Rev 12/05

(OUT) SC

(OUT) SC

S5694

NON-CODED ALARM BOX 36CC

S5694

(OUT) SC

S5694

NON-CODED ALARM BOX 36CC

(OUT) SC

Hochiki America Corporation DCP-AMS, DCP-AMS-LP, DCP-AMS-KL AND DCP-AMS-KL-LP

Specifications subject to change without notice.

S-ar putea să vă placă și