Sunteți pe pagina 1din 18

The essential guide

Networks, connectivity and Web servers

2013

ConneXium cabling system


ConneXium
ConneXium products are the industrial Ethernet-ready network devices that can provide you with integrated Ethernet solutions to unite everything in your plant, from the device level all the way to your corporate intranet. With innovative new tools like ConneXview Industrial Ethernet Diagnostic Software, intelligent managed switches, and an ever-expanding line of cables and accessories, the ConneXium range can help you realize the benets of open and reliable networking in the industrial environment.

A unied communication solution based on Ethernet standards and 3rd party compatibility
Improved network performance
ConneXium switched networks limit the number of collisions in the media and increase overall network performance. Furthermore, ConneXium full duplex capability delivers a high level of determinism to your industrial Ethernet network. ConneXium IP Multicast capability supports the Publish/Subscribe and streaming protocols of todays Industrial networks.

ConneXview Ethernet Diagnostic Software


Help your network perform at peak efciency with ConneXview, the powerful yet easy to use Ethernet network diagnostic tool. It automatically discovers and maps your networks and devices, then gives you all the tools youll need to easily monitor and troubleshoot network operations.

Diagnosing and managing installations


ConneXium switches implement SNMP protocol to facilitate network monitoring and diagnosis of problems. A web server is embedded in every TCSESM switch to deliver complementary management services that can be accessed via any web browser.

Fault-Tolerant
ConneXium managed switches incorporate a mechanism to support a high level of resilience. With their scalable redundant features, from single to double ring structure, it is easy to build a network that ts the specic requirements of your environment.

Designed for Harsh Environments


p Industrial IEC 61131-2 p UL & FM3611 Class 1, Div 2 p Marine

Contents
h ction ent is a sele This documselling products. of the top n: informatio m For moren -electric.co er d ei ch ttp://www.s

ConneXium cabling system


Hub, IP 67 Switch ........................................................................................................................... 2 Switches .................................................................................................................................. 3 to 7 Gateways ........................................................................................................................................ 8 Cables and Connectors .................................................................................................................. 9 WiFi products ................................................................................................................................ 10

Servers and Gateways


Data server software, OPC Factory Server .................................................................................................................... 12 Other servers and gateways, FactoryCast ........................................................................................................................ 13 to 15

ConneXium

Ethernet TCP/IP, Transparent Ready


Cabling system: ConneXium Hub, Transceiver and Switch

Hub
Interfaces Copper cable ports Number and type Shielded connectors Medium Total length of pair Power supply Degree of protection Dimensions W x H x D Conformity to standards Reference Voltage 4 x 10BASE-T ports RJ45 Shielded twisted pair, category CAT 5E 100 m 24 V (1832) DC, safety extra low voltage (SELV) IP 30 40 x 125 x 80 mm cUL 60950, UL 508 and CSA 142, UL 1604 and CSA 213 Class 1 Division 2, e, GL FM 3810, FM 3611 Class 1 Division 2 , C-TICK 499 NEH 104 10

IP 67 switch
Interfaces Copper cable ports Number and type Shielded connectors Medium Total length of pair Power supply Degree of protection Dimensions W x H x D Conformity to standards Reference Voltage

Twisted pair, unmanaged


5 x 10BASE-T/100BASE-TX ports M12 (type D) Shielded twisted pair, category CAT 5E 100 m with rated cable 24 VDC (1832 VDC), safety extra low voltage (SELV) IP 65/67 60 x 126 x 31 mm cUL 508 and CSA 22.2 14 , C-TICK TCS ESU 051 F0

ConneXium

Ethernet TCP/IP, Transparent Ready


Cabling system: ConneXium unmanaged switches

Switches
Interfaces Copper cable ports Number and type Shielded connectors Medium Total length of pair Fiber optic ports Number and type Connectors Medium Length of optical ber 50/125 m ber 62,2/125 m ber Attenuation analys 50/125 m ber 62,2/125 m ber Power supply Voltage, safety extra low voltage (SELV) Power consumption Connector Degree of protection Dimensionss Weight Conformity to standards Alarm relay Reference WxHxD

Copper twisted pair, unmanaged


3 x 10BASE-T/ 100BASE-TX 4 x 10BASE-T/ 100BASE-TX ports Type RJ45 Shielded twisted pair, category CAT 5E 100 m Max. 2,2 W IP 30 25 x 114 x 79 mm 0,113 kg 0,120 kg 0,113 kg UL 508 and CSA 22.2 N 142 IEC/EN 61131-2, IEC 60825-1 class 1, CISPR 11A TCS ESU 033FN0 TCS ESU 043F1N0 TCS ESU 053FN0 TCS ESU 083FN0 35 x 138 x 121 mm 0,246 kg 1 x 100BASE-FX ports Duplex SC Multimode optical ber 5000 m (1) 4000 m (1) 8 dB 11 dB Max. 3,9 W Max. 2,2 W Max. 4,1 W ports 5 x 10BASE-T/ 100BASE-TX ports 8 x 10BASE-T/ 100BASE-TX ports

c 24 VDC (c 9,632 VDC) 3 way removable connector

(1) Length dependent on the attenuation analysis and attenuation of the ber optic (typical value: 2,000 m).

Switches
Interfaces Copper cable ports Number and type Shielded connectors Medium Total length of pair Fiber optic ports Number and type Connectors Medium Length of optical ber 50/125 m ber 62.2/125 m ber 9/125 m ber Power supply Dimensions Conformity to standards References Voltage WxHxD Degree of protection

Copper twisted pair and bre optic, unmanaged


4 x 10BASE-T/ RJ45 Shielded twisted pair, category CAT 5E 100 m 1 x 100BASE-FX port SC Multimode optical ber 5000 m (1) 4000 m (1) IP 20 47 x 135 x 111 mm cUL 60950, cUL 508 and CSA 142, UL 1604 and CSA 213 Class 1 Division 2, e, GL , C-TICK 499 NMS 251 01 499 NMS 251 02 499 NSS 251 01 499 NSS 251 02 499 NES 181 00 Single mode optical ber 32 500 m (2) 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports 3 x 10BASE-T/ 4 x 10BASE-T/ 3 x 10BASE-T/ 8 x 10BASE-T/

100BASE-TX ports 100BASE-TX ports 100BASE-TX ports 100BASE-TX ports 100BASE-TX ports

24 VDC (1832), safety extra low voltage (SELV)

(1) Length dependent on the attenuation analysis and attenuation of the ber optic (typical value: 2,000 m). (2) Length dependent on the attenuation analysis and attenuation of the ber optic (typical value: 15,000 m).

ConneXium

Ethernet TCP/IP, Transparent Ready


Cabling system: ConneXium managed switches

Switches
Interfaces Copper cable ports Number and type Medium Total length of pair Fiber optic ports Number and type Connectors Medium Length of optical ber 50/125 m ber 9/125 m ber Power supply Degree of protection Dimensions W x H x D Conformity to standards References Voltage Operation

Copper twisted pair and ber optic, managed


3 x 10/100BASE-TX ports 2 x 10/100BASE-TX ports 3 x 10/100BASE-TX ports 2 x 10/100BASE-TX ports Shielded twisted pair, category CAT 5E 100 m 1 x 100BASE-FX port Duplex SC Multimode optical ber 5,000 m (1) IP 20 47 x 131 x 111 mm IEC 61131-2, UL 508, UL 1604 Class 1 Division 2, CSA C22.2 14 (cUL), CSA C22.2 213 Class 1 Division 2 (cUL), e, GL , C-TICK TCSESM043F1CU0 TCSESM043F2CU0 TCSESM043F1CS0 TCSESM043F2CS0 Single mode optical ber 32,500 m (2) 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports

Shielded connectors RJ45

62.2/125 m ber 4,000 m (1)

9.6...60 VDC/1830 VAC, safety extra low voltage (SELV)

(1) Length dependent on the attenuation analysis and attenuation of the ber optic (typical value: 2,000 m). (2) Length dependent on the attenuation analysis and attenuation of the ber optic (typical value: 15,000 m).

Switches
Interfaces Copper cable ports Number and type Shielded connectors Medium Total length of pair Power supply Degree of protection Dimensions W x H x D Conformity to standards References Voltage Operation

Copper twisted pair, managed


4 x 10/100BASE-TX ports RJ45 Shielded twisted pair, category CAT 5E 100 m 9.6...60 VDC/1830 VAC, safety extra low voltage (SELV) IP 20 47 x 131 x 111 mm 74 x 131 x 111 mm IEC 61131-2, UL 508, UL 1604 Class 1 Division 2, CSA C22.2 14 (cUL), CSA C22.2 213 Class 1 Division 2 (cUL), e, GL , C-TICK TCSESM043F23F0 TCSESM083F23F0 8 x 10/100BASE-TX ports

ConneXium

Ethernet TCP/IP, Transparent Ready


Cabling system: ConneXium managed switches

Switches
Interfaces Copper cable ports Number and type Shielded connectors Medium Total length of pair Fiber optic ports Number and type Connectors Medium

Copper twisted pair and ber optic, managed


7 x 10/100BASE-TX ports RJ45 Shielded twisted pair, category CAT 5E 100 m 1 x 100BASE-FX port Duplex SC Multimode optical ber (MM) Single mode optical ber (SM) 2 x 100BASE-FX port 1 x 100BASE-FX port 2 x 100BASE-FX port 6 x 10/100BASE-TX ports 7 x 10/100BASE-TX ports 6 x 10/100BASE-T ports

Length of optical ber 50/125 m ber 9/125 m ber Power supply Degree of protection Dimensions W x H x D Conformity to standards References Voltage Operation 5,000 m (1) IP 20 74 x 131 x 111 mm IEC 61131-2, UL 508, UL 1604 Class 1 Division 2, CSA C22.2 14 (cUL), CSA C22.2 213 Class 1 Division 2 (cUL), e, GL , C-TICK TCSESM083F1CU0 TCSESM083F2CU0 TCSESM083F1CS0 TCSESM083F2CS0 (1) Length dependent on the attenuation analysis and attenuation of the ber optic (typical value: 2,000 m). (2) Length dependent on the attenuation analysis and attenuation of the ber optic (typical value: 15,000 m). 32,500 m (2) 62.2/125 m ber 4,000 m (1)

9.6...60 VDC/1830 VAC, safety extra low voltage (SELV)

Switches
Interfaces Copper cable ports Number and type Shielded connectors Total length of pair Fiber optic ports Number and type Connector Medium Length of optical ber 50/125 m ber 62.2/125 m ber Power supply Degree of protection Dimensions W x H x D Conformity to standards References Voltage Operation

Copper twisted pair, managed


RJ45 100 m IP 20 111 x 131 x 111 mm

Copper twisted pair and ber optic, managed

16 x 10/100BASE-TX ports 14 x 10/100BASE-TX ports 22 x 10/100BASE-TX ports 14 ports 10/100BASE-TX

2 x 100BASE-FX ports Duplex SC Multimode optical ber 5,000 m (1) 4,000 m (1) Optical ber 32 500 M (2)

9.6...60 VDC/1830 VAC, safety extra low voltage (SELV)

cUL 60950, UL 508 and CSA 142, UL 1604 and CSA 213 Class 1 Division 2, e, GL , C-TICK TCSESM163F23F0 TCSESM163F2CU0 TCSESM243F2CU0 TCSESM16F2CS0

(1) Length dependent on the attenuation analysis and attenuation of the ber optic (typical value: 2,000 m).

ConneXium

Ethernet TCP/IP, Transparent Ready


Cabling system: ConneXium managed switches

Switches
Interfaces Copper cable ports Number and type Shielded connectors Medium Total length of pair Fiber optic ports Number and type Connectors Medium Length of optical ber 50/125 m ber 9/125 m ber Attentuation analysis 50/125 m bre 9/125 m ber Ethernet services Topology Redundancy Power supply Degree of protection Dimensions W x H x D Conformity to standards Alarm relay References Voltage Power consumption Operation Number of switches Cascaded Redundant in a ring

Copper twisted pair and bre optic, managed - extended features


8 x 10/100 BASE-TX ports RJ45 Shielded twisted pair, category CAT 5E 100 m 2 x 100BASE-FX ports Duplex SC Multi mode optical bre 5,000 m (1) 4,000 m (1) 8 dB 11 dB 2 x 100BASE-FX ports Duplex SC Single mode optical bre 32,500 m (2) 16 dB 6 x 10/100 BASE-TX ports 6 x 10/100 BASE-TX ports

62.2/125 m ber

62.2/125 m ber

FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol, conguration via Web access, VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port. Unlimited max. 50 Redundant power supplies, redundant single ring, ring coupling 18 - 60 V safety extra low voltage (SELV) 10 W IP30 120 x 137 x 115 mm IEC/EN 61131-2, IEC 61850-3, UL 508, UL ISA-12.12.-01 Class 1 Div 2 Group A, B, C, D, CSA 22.2 No. 142 (cUL), CSA 22.2 No. 213 Class 1 Division 2 (cUL), CE, GL, C-Tick Power supply fault, Ethernet network fault or communication port fault (2 A max. volt-free contact at 30 VDC) TCSESM083F23F1 TCSESM063F2CU1 TCSESM063F2CS1 12 W 12 W

(1) Length dependent on the attenuation analysis and attenuation of the lber optic (typical value: 2,000 m). (2) Length dependent on the attenuation analysis and attenuation of the lber optic (typical value: 15,000 m).

Switches
Interfaces Copper cable ports Number and type Shielded connectors Medium Total length of pair Fiber optic ports Number and type Connectors Medium Length of optical ber 50/125 m ber 9/125 m ber Attentuation analysis 50/125 m bre 9/125 m ber Ethernet services

Copper twisted pair and ber optic, managed


8 x 10/100 BASE-TX ports RJ45 Shielded twisted pair, category CAT 5E 100 m

Copper twisted pair, managed


8 x 10/100 BASE-TX ports 2 x 100 BASE-TX ports (Gigabits)

2 x 100BASE-SX ports (1) 2 x 100BASE-LH ports (2) 2 x 100BASE-LX ports (3) LC Multimode optical ber Single optical bre Single mode and multimode optical ber 550 m 7,5 dB 8 - 72,000 m 6 - 22 dB 550 m 550 m 20,000 m 11 dB 11 dB 11 dB

62.2/125 m ber 275 m

62.2/125 m ber 7,5 dB

FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol, conguration via Web ccess, VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port. Cascaded Redundant in a ring Unlimited max. 50 Redundant power supplies, redundant single ring, ring coupling 9,6...60 VDC/18...30 VAC, safety extra low voltage (SELV) IP20 111 x 113 x 111 mm cUL 60950, UL 508 and CSA 22.2, UL 1604 and CSA 213 CSA 22.2 No. 213 Class 1 Division 2, e, GL TCSESM103F2LG0 TCSESM103F23G0

Topology Redundancy Power supply Degree of protection Dimensions W x H x D

Number of switches

Voltage

Operation

Conformity to standards References (1) With TCSEAAF1LFU00 ber optic module to be ordered separately (2) With TCSEAAF1LFH00 ber optic module to be ordered separately (3) With TCSEAAF1LFS00 ber optic module to be ordered separately

Switches
Interfaces Copper cable ports Number and type Shielded connectors Total length of pair Fiber optic ports Number and type Connector Medium Length of optical ber 50/125 m ber 62.2/125 m ber Attenuation analysis 50/125 m ber 60.2/125 m ber Ethernet services

Copper twisted pair and ber optic, managed


6 x 10/100 BASE-TX ports RJ45 100 m 2 x 100 BASE-SX ports Duplex SC Multimode optical ber 5,000 m (1) 4,000 m (1) 8 dB 11 dB 3 x 100 BASE-LX ports

Copper twisted pair, managed


8 x 10/100 BASE-TX ports

FDR, SNTP client, multicast ltering for optimization of the Global Data protocol, conguration via Web access,IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port. Cascaded Redundant in a ring Unlimited Max. 50 Redundant power supplies UL 508, CSA C22.2, CSA No. 213, UL 1604, e TCSESB083F23F0 TCSESB083F2CU0 TCSESB093F2CU0

Topology Redundancy

Number of switches

Conformity to standards References

ConneXium

Ethernet gateways
Ethernet/Modbus gateway and Ethernet/Modbus Plus gateway/router

Type of gateway
Transparent Ready services Class Standard Web services Conguration Read/Write Diagnostic Ethernet TCP/IP communication management services Ethernet connectivity Physical interface Data rate Medium Modbus connectivity Type of port Protocol Maxi transmission speed Number of devices Power supply Degree of protection Dimensions W x H x D Conformity to standards Reference Modbus messaging SNMP BOOTP protocol Security

TSX ETG 100


B10 Predened Web pages Acces to connected products list, reading of Modbus devices registers Via predened Web pages : diagnostic on Ethernet and Modbus links Read/Write Modbus registers of connected devices SNMP Agent, device administration with a SNMP manager FDR Client (replacement of defective product) Miniature rewall on-board (IP address ltering) and password protection 10BASE-T/100BASE-TX (RJ45) 10/100 Mbps with automatic recognition Twisted pair RS 485 (2 or 4-wire) or RS 232 Modbus (RTU and ASCII) 38,4 Kbps (RS 485), 57,6 Kbps (RS 232) 32 max. 24 VDC, 4 W or by power supply device PoE (Power Over Ethernet - IEEE 802.3af) IP 30 72 x 81 x 76 mm, mounting on symmetrical DIN rail UL, cUL (conforming to CSA C22-2 no. 14-M91), UL508 , C-TICK, e TSX ETG 100 (1)

(1) Fonctions: Twido, Compact, Momentum, TSX Micro, Altivar, Altistart, Magelis, ... All products compatible with Modbus standard.

Type of gateway
Transparent Ready services Class Standard Web services Conguration Read/Write Diagnostic Standard Ethernet TCP/IP communication services Functions Communication gateway Interface for programming Interfaces Ethernet TCP/IP port Type Shielded connectors Medium Max. distances Serial port Type Shielded connectors Medium Power supply Degree of protection Dimensions W x H x D Conformity to standards Reference Voltage

Ethernet/Modbus Plus gateway/router Class B10


B10 Predened Web pages Acces to connected products list, reading of Modbus Plus devices registers Via predened Web pages : diagnostic on Ethernet and Modbus Plus links Modbus TCP messaging SNMP Agent Ethernet/Modbus Plus (many-to-many Modbus Plus) Ethernet/Modbus Plus 1 x 10BASE-T/100BASE-TX RJ45 Shielded twisted pair 100 m (327 ft) 1 x Modbus Plus 9-way SUB-D connector Shielded twisted pair (single or double) 110/220 VAC (93.5 VAC242 VAC), 4763 Hz IP 20 122 x 229 x 248 mm UL 508, CSA 142, e 174 CEV 200 40 (2)

(2) Fonctions: 1 Ethernet port, 10BASE-T/100BASE-TX, 1 Modbus Plus port

ConneXium

Ethernet TCP/IP, Transparent Ready


Cabling system: Connection components Shielded copper connection cables
ConneXium shielded connection cables are available in two versions to meet the various current standards and approvals:

These cables conform to: - EIA/TIA-568 standard, category CAT 5E, - IEC 11801/EN 50173 standard, class D. Their re resistance conforms to: - NFC 32070# C2 classication - IEC 322/1 standards - Low Smoke Zero Halogen (LSZH).

EIA/TIA 568 shielded twisted pair cables

EIA/TIA 568 shielded twisted pair cables for CE market


Length Straight cables References Crossed cord cables References Preformed at both ends m / (ft) Preformed at both ends 2 (6.6) 490 NTW 000 02 5 (16.4) 490 NTW 000 05 490 NTC 000 05 12 (39.4) 490 NTW 000 12 40 (131.2) 490 NTW 000 40 490 NTC 000 40 80 (262.5) 490 NTW 000 80 490 NTC 000 80

2 RJ45 connectors for connection to terminal devices (DTE) 2 RJ45 connectors for connections between hubs, switches and transceivers

Ethernet cables

Ethernet cables
Length References m / (ft) CE UL 1 (3.3) Cat 5E w/RJ45 TCSECE3M3M1S4 TCSECU3M3M1S4 TCSECE3M3M2S4 TCSECU3M3M2S4 TCSECE3M3M3S4 TCSECU3M3M3S4 TCSECE3M3M5S4 TCSECU3M3M5S4 TCSECE3M3M10S4 TCSECU3M3M10S4 2 (6.6) 3 (9.8) 5 (16.4) 10 (32.8)

EIA/TIA 568 shielded twisted pair cables


Cable material is : - CEC type FT-1 - NEC type CM

EIA/TIA shielded twisted pair cables for UL markets


Length Straight cables References Crossed cord cables References Preformed at both ends m / (ft) Preformed at both ends 2 (6.6) 5 (16.4) 12 (39.4) 15 (49.2) 40 (131.2) 80 (262.5)

2 RJ45 connectors for connection to terminal devices (DTE) 490 NTW 000 02U 490 NTW 000 05U 490 NTW 000 12U 490 NTC 000 05U 490 NTW 000 40U 490 NTW 000 80U 2 RJ45 connectors for connections between hubs, switches and transceivers 490 NTC 000 12U 490 NTC 000 40U 490 NTC 000 80U

Cables M12

Cables M12
M12 / M12 Reference RJ45 / M12 Reference Length(m) Length (m) 1 1 3 3 10 10 25 25 40 40

TCSECL1M1Mpp S2pp TCSECL1M3Mpp S2pp

Glass ber optic cables


These glass ber optics are for making connections: - To a terminal device (DTE) - Between hubs, transceivers and switches

Glass ber optic cables


Length Glass ber optic cables References m / (ft) Preformed at both ends 5 (16.4) 1 SC connector 1 MT-RJ connector 490 NOC 000 05 5 (16.4) 1 ST connector (BFOC) 1 MT-RJ connector 490 NOT 000 05 490 NOR 000 03 490 NOR 000 05 3 (9.8) 2 MT-RJ connectors 5 (16.4)

ConneXium

WiFi Products
WiFi Access Points and Clients - WiFi Antennas

Access Points and Clients

Dual band industrial wireless LAN Access Point/Client based on IEEE 802.11a/b/g/h/i
IEEE 802.11a/b/g/h/i 2.4GHz & 5GHz IP 40 Din Rail Access Point: 2 Client: 1 54 Mbps 4 x RP-SMA Access Points: 2 Client: 1 2 x WLAN Interfaces 8 SSIDs per interface IEEE 802.11a/b/g/h/i 2.4GHz & 5GHz IP 67 Wall / Mast 2 54 Mbps 4 x N-type 1 2 x WLAN Interfaces 8 SSIDs per interface TCSGWA272

Dual band industrial high performance wireless LAN Access Point/Client based on IEEE 802.11a/b/g/h/n
IEEE 802.11a/b/g/h/n 2.4GHz & 5GHz IP 40 Din Rail 1 300 Mbps 3 x RP-SMA 2 1 x WLAN Interfaces 8 SSIDs per interface TCSNWA241 TCSNWA241F IEEE 802.11a/b/g/h/n 2.4GHz & 5GHz IP 67 Wall / Mast 1 300 Mbps 4 x N-type 2 1 x WLAN Interfaces 8 SSIDs per interface TCSNWA271 TCSNWA271F TCSNWA2A1

Wireless standard Operating frequencies IP Rating Mounting Radios Nominal Data rate Antenna connections Ethernet connections (10/100BASE-TX) Wireless connections

References

Global North America (FCC approved) Client only ATEX Compliant

TCSGWA242 TCSGWA242F TCSGWC241

Antennas
2.4 GHz 2.4 GHz Omni Directional (6dBi) 2.4 GHz Directional (14dBi) 2.4 GHz Dual Slant (8dBi) Leaky Cable 50 meter Leaky Cable 100 meter 5 GHz 5 GHz Omni Directional (5dBi) 5 GHz Directional Medium (18.5dBi) 5 GHz Directional Long (23dBi) 5 GHz Directional 802.11n (23dBi) 5 GHz Dual Slant (9dBi) 5 GHz Directional 802.11n (9dBi) Dual Band Dual Band Hemispherical (6dBi/8dBi)

TSCG**** Compatible References (1)


TCSWAB2O TCSWAB2D TCSWAB2S TCSWABC5 TCSWABC10 TCSWAB5O TCSWAB5D TCSWAB5V TCSWAB5VN TCSWAB5S TCSWABDH

TSCN**** Compatible References (1)


TCSWAB2S TCSWAB5V TCSWAB5VN TCSWAB5DN TCSWABDON

Dual Band Omni (3.5dBi/5.5dBi) (1) Consult www.schneider-electric.com for a complete list of antenna cables and accessories for WiFi products

10

ConneXium

Notes

11

OFS

OPC data server software

Type
Items number OPC protocols References Single station licence 10 stations licence 200 stations licence

OPC data server OFS Small


1000 items OPC DA, OPC UA TLX CDSUOFS34 TLX CDSTOFS34

OFS Large
Unlimited OPC DA, OPC UA , OPC XML DA TLX CDLUOFS TLX CDLTOFS34 TLX CDLFOFS34

Ethernet TCP/IP network DCOM ou HTTP OFS station Remote client application program Local client application program Data symbol (Concept, PL 7 or Unity pro

Modbus network

X-Way network

Momentum Quantum

Premium

TSX Micro

Description:
Based on the OPC protocols, Schneider-Electrics OFS software (OPC Factory Server) enables local or remote OPC client applications such as SCADA, supervisors or custom interfaces, to access Schneider devices and PLCs data in real time. OFS software is a multi-device data server which provides simultaneous use of various communication protocols, and allows client applications to access control data via physical addresses or via symbols. OFSV3.40 provides to SCADA at source time stamped data, with 1 ms resolution for BMXERT modules, and 10 ms resolution with regular x80 Digital IOs.

Supported devices :
p Modicon Quantum, Premium, Micro, Compact and Momentum PLCs p TSX Series 7 and April Series 1000 Schneider-Electric PLCs p Serial Modbus or Uni-Telway devices connected via Schneider-Electric and Merlin Gerin gateways TSX ETG 10xx, EGX xxx ranges etc.

Supported networks and protocols :


p Modbus: Serial Modbus, Modbus Plus, Modbus TCP/IP. p XWAY/UNI-TE: Uni-Telway, FIPWAY, ETHWAY, ISAWAY, PCIWAY.

Openess:
OFS V3.40, integrates the most recent specications of the OPC Foundation: p OPC-DA (OPC Data Access) p OPC-UA (OPC Unied architecture) p .NET API interface p OPC XML-DA V1.0 (OPC XML Data Access) The development of specialized interfaces is even more easy and open. Developers and System integrators can develop custom applications (in Visual Basic, VBA for Excel, C++, etc) requiring access to Schneider Electric control devices. The OPC XML-DA V1.0 interface is designed to provide an interface for Windows and non-Windows client applications and remote access via the Internet through rewalls.

12

FactoryCast

Web servers and Gateways

FactoryCast modules for PLC


Ready to use diagnostic and monitoring functions embedded in a PLC module accessible remotely via a simple Internet browser: b Real-time communication based on Ethernet TCP/IP (Modbus and Uni-TE) b Secure access to the PLC system and application diagnostics b Numerical or graphical data monitoring and control b E-mail notications b Web server open to user customization and creation of Web pages for diagnostics suited to your needs b Library of animated graphic objects b Open communications using SOAP/XML protocol as a server interface (Web services) b Visualization of Unity Pro IEC program via Web pages b New - SilverLight based Rack Viewer b New - Custom Web pages using Microsoft Expression Blend

FactoryCast HMI modules for PLC


Diagnostic functions Identical as FactoryCast modules + Built-in HMI / SCADA functions embedded in a PLC module: b Visualization of Unity Pro PLC program and Operator screens via Web pages b PLC data acquisition b Calculations scripts for data-processing Real-time database (1000 variables) b Alarm and report notications via E-mail b Archiving of data directly into database servers (SQL, Oracle, MySQL) b Data logging in CSV les in the module. b Recipe management with read Database b Dynamic HTML Reporting function b Web server open to user Web pages customization b Built-in Supervision via graphic screens and custom Web pages b Data monitoring and Graphic monitoring (read/write) b Library of animated graphic objects b Open communication using SOAP/XML protocol as a server interface (Web services)

Embedded in the TCP/IP communication modules for Modicon M340, Premium and Quantum PLCs, FactoryCast Web servers provide secured access to the diagnotics, monitoring and maintenance functions of your automation installations via a simple web browser.

FactoryCast Gateways - ETG 1000 / 10.. modules


Cost-effective web gateways offer integrating in a stand-alone module: b All Communications network interfaces: Ethernet TCP/IP, Modbus and Uni-Telway b Remote access functions, RAS server, b Transparent gateway / Router functions b Notication of alarms via E-mail b Data monitoring and Graphic monitoring (read/write) b A user customizable Web server for creating an interface fully adapted to your needs b Library of animated graphic objects

FactoryCast HMI Gateways - ETG 3000 / 30.. modules


All in one Web gateway module integrating in a stand-alone device: b a built-in modem (PSTN or GSM/GPRS) depending on the reference b Secured access : VPN, data encryption and IP ltering. b A Remote Access server function (RAS) b 2 Ethernet ports and a Modbus serial port b Transparent gateway router functions NAT to Ethernet or Modbus serial devices b I/O card : 6 discrete inputs/ 2 discrete outputs b Operating temperature : -25C to +75C b User customizable Web server b Built-in Supervision via graphic screens and custom Web pages b Data monitoring and Graphic monitoring (read/write) b Data Acquisition, Data Processing and Data logging in the module (CSV les) b Archiving of data directly into database servers (SQL, Oracle, MySQL) b Alarms and reports via E-mail / SMS b Open communication using SOAP/XML protocol as a server interface

In the areas of distributed infrastructures, transport, RTU installations, industry and machines, ETG 1000 / 3000 modules more than satisfy your requirements for remote diagnotics and maintenance, remote monitoring and control, and remote programming.

13

FactoryCast

FactoryCast PLC
Embedded Web Servers

Applications
Target devices Network & Remote access services Type Remote access

Web Server modules for PLCs FactoryCast


TSX Micro PLCs Modicon M340 PLCs Modicon Premium PLCs Modicon Quantum PLCs

FactoryCast HMI
Modicon Premium PLCs Modicon Quantum PLCs

Intranet or via external RAS/modem Remote programming, downloading via FTP, access to Web server via Internet browser

Gateway function Serial protocols Ethernet protocols TCP/IP protocols Security Web server Predened services Characteristics Conguration Diagnostics Monitoring of variables Alarm management Customizable services Graphic views Unity Pro operator screen User Web pages Advanced services and HMI Calculation scripts E-mail service Data logging Database connection Report service Recipe service

Modbus TCP, Uni-TE Modbus TCP Modbus TCP, Uni-TE Modbus TCP Modbus TCP, Uni-TE Modbus TCP

BootP/DHCP, DNS, SNMP agent, SMTP client, NTP client, FTP Protection by IP address ltering and passwords HTTP and FTP server, 8 Mb memory available for user add (32 MB of memory for M340), hosting of user Web pages and documents (Doc, Pdf, Excel) Via Web Designer software or predened Web pages System, rack and PLC I/O diagnostics via predened Web pages Monitoring of devices and application via animated data (read/write variables) PLCs and applications alarms monitoring via predened Web pages Graphic monitoring via animated pages (integrated graphic editor) Graphic monitoring via animated Web pages created by the user Alarm notication by E-mail Data logging in the module with time stamping (CSV les) Direct logging in an SQL, Oracle, MySQL database servers Dynamic HTML report management Management of Recipe data (storage and read locally or on remote database) Unity Pro IEC Program Sections are visible and animated. Viewable from Windows based browsers Arithmetic and logical scripts Display in the form of Web pages

PLC programme visualization by Web page

Application development sofware

Web Designer
Supplied with each module

References

TSXETZ510

BMXNOE0110

TSXETY5103

140NOE77111

TSXWMY100

140NWM10000

14

FactoryCast Gateway
Web Gateways for Remote control

Standalone Gateway, Web Server for Remote Access FactoryCast Gateway ETG 10p0
All equipment supporting Modbus All equipment supporting Uni-Telway

FactoryCast HMI Gateway ETG30pp


All Modicon PLCs and third-party equipment supporting Modbus Intranet or Modem External modem, integrated RAS Intranet or Modem Integrated PSTN/RTC/GSM modem and RAS modem, NAT

Intranet or via external Modem, integrated RAS function

Remote programming, downloading via FTP, access to Web server via Internet browser Ethernet to Modbus serial Ethernet to Uni-Telway serial Ethernet to Modbus serial Modem to Modbus serial and Ethernet Modem to Uni-Telway and Ethernet Modem to Modbus serial and Ethernet (Modbus, UNITE) Modbus (Master) Modbus TCP Uni-Telway (Slave) Modbus TCP, Uni-TE (Modicon Premium, Modicon TSX Micro) Modbus (Master) Modbus TCP Uni-TE TCP DHCP, DNS, SNMP agent, SMTP client, NTP client, FTP Protection by IP address ltering and password + Tunnels VPN & encryption of the datas. HTTP and FTP server, 32 Mb memory available for user Web pages, memory extension using Compact Flash cards 1 Gb max., hosting of user Web pages and documents (Doc, Pdf, Excel)

BootP/DHCP, SNMP agent, SMTP client, NTP client, FTP Protection by IP address ltering and password HTTP and FTP server, 8 Mb memory available for user, hosting of user Web pages and documents (Doc, Pdf, Excel) Via Web Designer software or predened Web pages Diagnostics of serial devices via predened Web pages Via E-mail Graphic monitoring via animated views (integrated graphic editor) Graphic monitoring via animated Web pages created by the user Alarm notication by E-mail

Network diagnostics, diagnostics of serial devices and Ethernet via predened Web pages Via E-mail/SMS

Monitoring of devices and application via data tables (read/write variables)

Arithmetic and logical scripts Alarm notication by E-mail/SMS Data logging in the module with time stamping (CSV les) Direct recording in SQL, Oracle, MySQL database servers Dynamic HTML report management Management of Recipe data (storage and revad locally or on remote database)

Web Designer
Supplied with each module

TSXETG1000

TSXETG1010

TSXETG3000

TSXETG3010 (Modem RTC)

TSXETG3021 Modem GSM/GPRS (Bands 900/1800MHz) TSXETG3022 Modem GSM/GPRS (Bands 850/1900 MHz)

15

Schneider Electric Industries SAS


Head Ofce 35, rue Joseph Monier - CS 30323 F92500 Rueil-Malmaison Cedex France The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specic user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specic application or use thereof. Neither Schneider Electric nor any of its afliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Design : IGS-CP Photos : Schneider Electric Print : 01/2013

www.schneider-electric.com

DIA6ED2130205EN

S-ar putea să vă placă și