CCTV Transmission Using Fibre Optics







1 INTRODUCTION

The use of fibre optic transmission is now commonplace in telecommunications, data
communications and broadcast quality television signal applications. In contrast the use of
optical fibre as the transmission media in CCTV security and surveillance applications is a
relatively recent development fuelled in the 1990`s by the need for the installation of
extensive CCTV systems to combat crime, vandalism and terrorism. Conventionally
cameras are linked to monitors over copper cable links using the lowest cost components
available. As system size has increased the distance between cameras and monitors has
also increased resulting in an unacceptable degradation of received video signal quality. i.e.
received picture quality, for link distances over 100 - 150 m. This has meant that the use of
optical fibre transmission has had to be considered even in this most cost conscious of
applications.

In these sections we will attempt to de-mystify fibre optic transmission as applied to CCTV
system use. We will start by outlining why fibre optics should be used, go on to consider the
basic elements of a fibre optic system and installation practice and finally outline the
technology to extend CCTV systems from essentially local installations to extensive,
distributed multi-channel signal transmission systems.


Page 2 of 2

2 WHY USE FIBRE OPTICS?

The principle reasons for using optical fibre as the transmission media in CCTV
applications are:

The maintenance of picture quality and control data integrity over extended
distances:

This is the major reason for using fibre optics which have superior signal amplitude
loss characteristics than copper cable. Typically co-axial cable attenuation at a
signal frequency of 5 MHz can be 20 dB/km. In comparison fibre attenuation is
between 0.3 and 3 dB/km meaning that fibre optic link distances of 60 km+ can be
achieved, depending on the precise details of the application. In addition this low
fibre signal attenuation is achieved over a very wide signal frequency range so that
optical fibre can be used for the transmission of multiple video signals over long
distances.

Immunity to electromagnetic interference:

Optical fibre transmits signals as light pulses rather than electrical pulses. This
light transmission is unaffected by the presence of electro-magnetic fields. As a
consequence optical fibre transmission can be used in applications where links are
routed near electrical conductors and electrical machines. This includes applications
such as railways, tramways, power generation and vehicle manufacture with
welding machinery. In addition the fibre cable usually has a metal free construction
so that there are no ground loop problems between terminal equipment and the
cable will not transmit lightning pulses. This elimination of ground loops makes
fibre cable the media of choice for inter building links of whatever distance.

Security of Information and Operational Safety

Unlike copper cables fibre cables do not radiate any signals as a consequence fibre
cables are virtually immune from tapping and so the signal content is difficult to
access for unauthorised parties. As there are no emissions from optical fibre cable
there is no risk that a fibre installation will act as a ignition source. This means
that fibre can be used in explosive atmospheres such as chemical and petro-chemical
sites providing a truly Intrinsically Safe transmission path. Note however, that
this Intrinsic Safety, would not extend to the electro-optic termination modems
which would need to be safety certified and protected the same as any other
electrical equipment.

Efficient use of duct space.

Optical fibre itself is very small, each glass fibre being only 0.125mm diameter.
Protective sheathing is then applied in stages, depending on the application area, to
make up the fibre into a usable cable. Typically resulting cable would have a
diameter of 3mm for a single fibre core patchlead or 8mm for a 8 fibre cable suitable
for internal or external use. In contrast 75 Ohm CT100 coaxial copper cable has a
diameter of 6.5 mm. It can therefore be seen that the small size of fibre cable gives
significant savings over copper where installation space is in short supply or where
duct space is limited. Along with the small fibre cable size comes a weight saving
both of which give savings in storage and transportation costs prior to installation.


Page 3 of 3

Multi-channel capability and Future Proofing.

While most CCTV fibres today will be used to transmit one video signal and perhaps
a control data signal, the user may wish to upgrade the system to support more
camera and control channels. Any glass optical fibre used today is able to transmit
multiple optical channels either by using different optical carrier colours i.e.
wavelength division multiplexing or by increasing the signal frequency using
electrical multiplexing techniques. The transmission media is hence future proofed
and the link will need only additional terminal equipment to expand the link
capacity.











































Page 4 of 4
3 COMPONENTS OF A FIBRE OPTIC CCTV TRANSMISSION SYSTEM

The sole purpose of the fibre optic link in a CCTV fibre optic transmission system is to
transfer electrical signals between two remotely separated points, A and B, with no
degradation in the transmitted signal quality. In this way the fibre optic link becomes
transparent to the user. An analogous situation is with a telephone call where you want to
be able to talk to another person anywhere as though they were standing next to you.

The basic components of a CCTV fibre optic transmission system are as follows:

Electrical to Optical Converter (Transmitter) at the camera end of the link.

This unit takes the analogue 1 v peak to peak signal from the surveillance camera
and converts it into a light signal that varies in proportion to the camera output
signal. The light signal is generated by an LED (light emitting diode) or laser
transmitter which is designed to couple a maximum of the generated light into an
optical fibre.

The optical transmission fibre and fibre cable.

The optical fibre guides the light from the LED or laser transmitter with a minimum
of loss to the monitor or matrix controller end of the link. The optical fibre itself is
protected by a variety of sheathing materials to provide a cable construction
appropriate to the specific application. The fibre cable is connected to the terminal
equipment using de-mountable screw or bayonet fixing connectors.

Optical to Electrical Converter (Receiver) at the monitor end of the link.

This unit takes the optical signal from the optical fibre and converts it into an
analogue electrical signal that is compatible with the monitor input requirements.
The light to electrical conversion is carried out by a semiconductor detector which is
called a photodiode, or an avalanche photodiode. Subsequent electronic circuitry
regenerates the output signal. Products from the better quality manufacturers
compensate for optical fibre losses and transmitter output intensity variation with
time and temperature by providing automatic gain control to give a standard 1 v
peak to peak output format as generated at the camera output.

Control data and audio connections.

Cameras in CCTV installations are either fixed, viewing a specific scene, or movable,
so that different scenes can be viewed under the direction of the operator who would
be sited in the remote control room. In the case of fixed cameras then the fibre optic
link is required to transmit video only information from the camera to monitor, this
requires only a single fibre link for each camera to monitor path. In the case of a
movable camera then a return signal must be provided from the control room to the
camera usually over a second optical fibre. It is usual for these return control links
to provide remote control of the camera PTZ - pan, tilt and zoom functions plus
camera enclosure wash/wipe activation.

If camera control is used then the fibre optic link interface electronics must be
compatible with the protocols used by the controller manufacturer. These functions
are transmitted over the return fibre link using a standard digital transmission
format such as RS232, RS485/422, 20 mA current loop and most recently Echelon
Lonworks FTT10A. In addition some controller manufacturers require a return data
channel from the camera to confirm camera movement. This return data is usually
Page 5 of 5
encoded by the camera optical transmitter electronics and sent over the same fibre
as the video signal.

Help point and door entry installations require the transmission of two-way audio
signals over the fibre link. Again optical transmitter and receiver units are available
to provide this facility in addition to the video and control data links all over the
same two fibres. It is also possible to provide all of these video, data and audio
transmission functions over one fibre using different wavelength (colour) lights
sources to transmit light in each direction. This technique is known as wavelength
division multiplexing; it maximises the use of installed fibre cores but at the expense
of more costly transmitters and receivers.

Page 6 of 6

4 OPTICAL FIBRE BASICS

We are all familiar with the everyday use of light, X-rays, radio waves, microwaves and
Radar. All of these are actually examples of electromagnetic radiation, which is
characterised by a radiation wavelength or oscillation frequency. Fig 1 shows the
electromagnetic spectrum with application areas identified. The 400 - 750 nm region of the
spectrum is the region of visible light; this region is expanded in the lower part of Fig 1.
The area of interest for fibre optic transmission extends from the red region of the spectrum
out into the wavelengths just longer than those visible to the human eye , the infra-red.
Specific wavelengths used have been driven by the requirements of the fibre technology and
by source and detector technologies. Particular wavelengths used are nominally 780nm,
850nm, 1310nm and 1550nm.
























Opical Fibre Structure and Light Guiding.

The optical fibre is made from a rod of highly purified silica called a preform. The
preform is heated and drawn out into a thin fibre using highly specialised and
accurate equipment. As the fibre is drawn it is coated with a protective polymer
layer known as the primary coating. At this stage the coated fibre is approximately
0.25mm diameter and is flexible enough to be coiled on drums with a bend radius of
not less than 5 cm. In most fibres in use today the diameter of the glass fibre itself is
125 microns/ 0.25 mm. This primary coated fibre is then used as the building block
for assembly into optical fibre cable, which provides the ruggedisation needed for
everyday use.







Wavelength
Hz 0 -Hz 1K
Hz
100Km
10K Hz
10Km
LW MW VHF UHF
1m
Microwave
1cm
10MHz 1GHz 10GHz
1mm 100um 10um 1um 100nm 10n 1nm 100pm 10pm
10 x 16 10 x 19
Hz
Low Frequency
DC
Radio
Television
THE ELECTROMAGNETIC SPECTRUM
1.6um 1.5um 1.4um 1.3um 1.2um 1.1um 1um
900nm 800nm 700nm 600nm 500nm 400nm
Optical Fibre Transmission Range
Visible Light
Infra - Red Ultra - Violet
10THz
Satellite
Page 7 of 7
An optical fibre is a complex strand of silica glass. A cross section of a typical fibre is
shown in Fig 2.

















It can be seen from Fig 2 that the optical fibre itself has internal structure with the
refractive index of the fibre varying across its diameter with all fibres having a
lower refractive index on the surface than at the centre of the fibre. This variation in
refractive index across the fibre diameter is the key to the transmission of light by
the fibre. Remembering our school physics experiments when light passes from a
high to low refractive index media e.g. glass to air, some of the light ray is reflected
and some is refracted out of the high refractive index media. As the angle of the light
ray to the surface gets shallower there comes a point where all of the light is
reflected and no light is refracted out of the media. This angle (to the normal) is
called the Critical Angle above which all light is reflected; optical fibre transmission
uses this effect to transmit light along the fibre.

In Fig 2 the optical fibre structure is assumed to consist of a high refractive index
glass core surrounded by a low refractive index glass cladding. Light rays are
incident on the fibre end from a light source entering the fibre core over a range of
incident angles. Once in the fibre these rays can be considered to be travelling in
straight lines until they meet a refractive index discontinuity. At this point some of
the ray is reflected back into the fibre core and the rest is refracted out of the core
into the cladding glass. The reflected light ray then transits the fibre core until
another reflection occurs and the refracted ray hits the cladding glass/protective
polymer cladding interface and is absorbed or dispersed. As we are concerned with
light propagation down the fibre length it is clear that the reflected ray is the one
that we require for signal transmission, with the refracted ray simply reducing the
transmitted light signal intensity.

If we consider a continuum of light rays in the fibre core covering all possible angles
of incidence to the core/cladding discontinuity then it can be seen that all light rays
with an angle of incidence above the critical angle will be reflected back into the
fibre core. This is known as total internal reflection. Those rays with an angle of
incidence above the critical angle will be partly reflected and partly refracted in the
manner explained above. The light rays transit along the fibre by being reflected at
each refractive index change that they encounter; in effect the rays bounce off of the
sides of the fibre core.

After multiple reflections, the rays with angles of incidence below the critical angle
will have been reduced in intensity by refraction losses and do not contribute to the
Page 8 of 8
light, and hence signal, transmission process. In contrast the rays with angles of
incidence above the critical angle will not be reduced in intensity by refraction and it
is these rays that enable fibre optic transmission to work. As the angle of incidence
is measured with respect to the normal to the relevant surface it can be seen that
the fibre could be bent and twisted and still allow light to be transmitted along its
length. This ability of optical fibre to guide light along a non-linear path, just like
and electrical conductor, is essential for its use in real world applications. We can
trace this range of rays back to their original coupling to the fibre core and we find
that the transmitted rays are contained in a cone of angles as shown in Fig 2.
In defining optical fibre parameters this acceptance cone is characterised by the cone
half angle and the Sine of this half angle is known as the fibre Numerical Aperture
N.A.

Multi-mode and Single Mode Fibre

Whilst we can now see how light is transmitted along a fibre core there is another
complication due to the wave nature of light. The result is that only certain
transmission paths, or angles of incidence, can be supported and each path is called
a mode. The quantity of modes available depends on the precise details of the fibre
construction. Broadly we can classify fibre types into multi-mode and single
mode fibres. Referring to Fig 2, today the vast majority of fibre produced has an
outer diameter (of the glass fibre NOT// the polymer primary coating) of 125 microns
with a core diameter of 50 or 62.5 microns for multi-mode fibre or 8 microns for
single mode fibre. In addition the core of a multi-mode fibre is usually made up from
a range of glass compositions to give a parabolic distribution of refractive index
across the fibre core diameter, the highest refractive index is on the fibre axis. These
graded index fibres are used to improve the transmission speed i.e. bandwidth,
characteristics of the fibre. In contrast single mode fibre is almost universally made
up from core material with a single refractive index resulting in a structure called
step index for obvious reasons. The bandwidth capacity single mode fibre is not
affected by the use of a step index geometry because only one transmission mode is
supported. Early multi-mode fibre was made in step index form because this
structure was the simplest to manufacture and gave higher fibre N.A. values thus
allowing more efficient coupling of light from LED or laser light sources. Advances
in LED and laser technology plus higher fibre bandwidth requirements, driven by
data communications applications, have resulted in graded index structures now
being the predominant fibre type used.

The transmission characteristics of multi-mode fibres make them best suited for the
majority of local site CCTV applications where transmission distances of up to 4 km
are found. Single mode fibres are best suited to high speed, long distance
applications such as telecommunications or CCTV in transportation applications.

Fibre Transmission Losses

Optical fibre transmission characteristics are different for different light
wavelengths. It is therefore necessary to choose the optimum wavelength for the
required application. However, as a user of fibre optics in CCTV applications you
will not need to worry about this choice because the terminal equipment
manufacturer will have sorted this out for you. The two fibre parameters affected by
wavelength are attenuation and bandwidth.




Page 9 of 9

Fibre Attenuation and Scattering

Light is transmitted along the core of an optical fibre by total internal reflection at
the core cladding interfaces. Whilst these reflections are effectively loss free the
interaction of the glass material and the light results in the intensity of the
transmitted light being reduced as the transmission distance increases. This is
equivalent to signal attenuation in a copper cable. These losses arise because of
absorption of light by impurities in the fibre core and because of scattering of the
light by core imperfections. The major impurity in silica based fibres has been
hydroxyl (OH) ions. Today fibre preforms are made using semiconductor type
preparation techniques and achieving semiconductor levels of purity. As a result
attenuation effects have been reduced to virtually negligible levels and scattering
has become a much more important loss mechanism. These optical attenuation
mechanisms are wavelength dependent. Fig 3 shows a typical optical fibre
attenuation with wavelength.




















It can be seen that attenuation reduces as the wavelength increases. It can also be
seen that there is a small bump in the curve at around 1400 nm/1.4 microns, this
has been included in this particular graph because it is indicative of the effect of
OH impurities. In the early days of fibre development OH impurity levels were
high and the resulting fibre absorption showed a minimum at approximately 850
900 nm (0.85 0.9 microns). As technology has improved this attenuation minimum
has moved out to wavelength bands around 1310 nm and 1550 nm. These bands are
known respectively as the First, Second and Third transmission windows.
Table 1 summarises optical fibre transmission properties for single mode and
multimode fibre. The CCTV equipment manufacturer will select and specify the
window that their products work over. The application requirements, costs of the
semiconductor sources and the detectors that are used in optical transmitters and
receivers govern the choice of operational window.






OPTICAL FIBRE ATTENUATION AS A FUNCTION OF WAVELENGTH
Page 10 of 10

Fibre Bandwidth

Whilst the signal speed with distance capacity of optical fibre is vastly in excess of
that achievable over a copper cable it still has some limitations. This is due to effects
known as modal dispersion, material dispersion and chromatic dispersion. These
effects are caused by geometric effects in the optical waveguide and by the speed of
light varying as a function of refractive index and wavelength. Note that single mode
fibre bandwidth is much higher than multimode and is expressed in units of
dispersion ps/nm.km vales of 3.5 and 18 at 1300 and 1550nm respectively are
typical.

Referring to Fig 2 it can be seen that in a multi-mode fibre different modes, or rays,
travel down the fibre over different paths and that these paths are of different
lengths. At a given wavelength the speed of light is constant, for a fixed refractive
index. And so, a light pulse which starts at the input of the fibre and fills all the
transmission modes will arrive at the far end of the fibre over a spread of times due
to different modes taking different times to transit the fibre. Graded index fibre
attempts to minimise these modal dispersion effects by reducing the transit time
difference between modes because the speed of light is higher in lower refractive
index media, that is the light speeds up in the regions furthest away from the centre
of the fibre core. Single mode fibre eliminates these material and modal dispersion
effects by using a step index structure and using a core size that only supports a
single transmission mode.

These transit time effects are also wavelength dependant. The effect is known as
chromatic dispersion and its significance lies in the fact that both LED and laser
sources emit light over a range of wavelengths. If we now consider the passage of a
one mode along a fibre, and remember that the speed of light is wavelength
dependant, then it can be seen that the different wavelengths of an instantaneous
light pulse will arrive at the end of the fibre at different times. This effect again
gives a pulse distortion and it is present in both single mode and multimode fibre,
although of less significance. The effect is minimised by using very narrow line but
very expensive laser sources.

These dispersion effects all contribute to limit the information carrying capacity of a
fibre by limiting the fibre bandwidth. This is expressed in units of MHz.km for
multimode fibre and can be assumed to be proportional to fibre length. Typical
values are given in Table 1.

Table 1 - Optical Fibre Parameters

Core
diameter
Microns
Numerical
Aperture
Attenuation dB/km Bandwidth MHz. km
@ 850nm @ 1300nm @ 1550nm @ 850nm @ 1300nm @ 1550nm
8 0.11 N/A 0.5 0.3 - - -
50 0.20 3.0 1.2 N/A 400 600 N/A
62.5 0.275 3.5 1.5 N/A 160 500 N/A






Page 11 of 11

Fibre bandwidth limitations are much more significant in data communications and
telecommunications systems than in CCTV systems. In a baseband CCTV link the
video signal bandwidth will not need to exceed 10 MHz, with 5.5 MHz actually being
sufficient. Taking a worst case of 850nm operation over 62.5/125 multimode fibre
with a bandwidth of 160 MHz.km gives a bandwidth limited link length of 160/10 =
16 kms. At this wavelength, with an attenuation of 3.5 dB/km, this would give a link
attenuation of 3.5 x 16 dB = 56 dB, which is far in excess of usual equipment loss
budgets of 12 dB for an LED based system.
Page 12 of 12


5 FIBRE OPTIC CABLE

Optical fibre by itself is too fragile to be used in real applications in the same way
that one would not use copper conductors without protection. In fact cabling
technologies used for copper conductors and for optical fibres are very similar. The
major difference is that optical fibre is slightly elastic and copper cable is inelastic
and this difference must be allowed for in cable design. Effectively, optical cable
design must ensure that any tension is born by the cable, and not by the optical
fibre. This is usually achieved by including a Kevlar strength member in the optical
cable design; Kevlar being a high strength polymer.

Cabling is about protecting the fibres from damage in use and presenting the fibres
in a way that enables ease of handling and ease of jointing. The precise design of
cable used depends on the details of the application and there are as many options
on optical fibre cable design as there are for copper cable design. Predominantly
CCTV work is concerned with transmission cable types for outdoor use and indoor
use. The main differentiation between these types is that outdoor cable will be used
in environments where it will come into contact with, or be immersed in, moisture
whereas indoor cable is not designed to be water ingress proof. In construction the
difference is that indoor cable is built up from layers of material tightly surrounding
the optical fibre. This type of cable is called tight jacket cable. In contrast, in
outdoor cable the optical fibre is contained in a plastic tube, which is often filled
with a water repelling gel. The fibre can move within this tube. This type of
construction is called loose tube cable.

Cables are made up from multiple optical fibres in physical arrangements
dependant on the intended application. Fibre counts in cables are commonly 1, 2, 4,
8, 12, 16, 24, 32 and up to 96 or beyond. Conventionally cables are circular but flat
cables for under carpet applications and ribbon cables for automated fibre jointing
are available. As a starting point in cable construction, the primary coated optical
fibre is covered with a further plastic conformal coating, which has a diameter of 0.5
mm to 0.9 mm. This secondary coating is usually coloured so that colour coding of
the fibre can be used in the cable construction. This secondary coated fibre looks
very much like conventional plastic coated copper wire.



















Figure 4

Page 13 of 13

Examples of typical tight jacket and loose tube cables are shown in Figs 4 and 5.













In the tight jacket cable a Kevlar strength member is wound around the optical fibre core
and a plastic sheath is moulded around this assembly. Typically for a single fibre cable
(simplex cable) the overall diameter of the cable would be no more than 3 mm. In a 2 fibre
cable (duplex cable) the fibres may be moulded in a circular or oval cross section cable or
may be joined by a central web to give the so called zip cord cable. Higher fibre count
cables use more complex geometrys often with the fibres arranged around a central
strength member core.

In loose tube construction a basic gel filled tube may be used to accommodate up to 8 or 12
fibres and this tube then used as the building block for higher fibre count cables. In any
structure these tubes are either arranged around a strength member for multi tube
constructions or in the case of a single tube, low fibre count cable then, the strength
member may be included in the tube or wound around it. The total assembly is then
encased in an appropriate overall sheathing material.

Both types of cable construction are completed with
an over sheath construction which gives the
required environmental protection. Plastic
materials now used are usually LSOH materials,
low smoke zero halogen, thus giving flame
retardance as well as being environment friendly.
It is also possible to surround the cable with a
metallic tape or welded steel layer to give an
armoured cable for protection against rodent and mechanical damage. Finally it is possible
to include copper conductors in the cable construction to enable remote power feed along
the cable whilst carrying signal traffic over the optical fibre. This hybrid construction does,
of course, negate one of the advantages of fibre optics for CCTV systems; namely that fibres
and cables are usually non-conducting so that they can be used to interconnect buildings
where earth potentials may differ. Nor will dielectric cables conduct lighting strikes from a
camera housing down to ground or control room equipment. Overall cable constructions are
likely to be available that will be able to satisfy all environmental requirements of CCTV
system installation whilst giving the optical fibre the required degree of environmental
protection to ensure long life, fault free utilisation.








Figure 5
Page 14 of 14
6. Fibre Jointing and Cable Installation Techniques

In any fibre optic installation optical fibres will need to be joined either to each other or to
terminal equipment. These joints can be either permanent or de-mountable depending on
the circumstances. In making a joint between fibres, all techniques are concerned with
aligning the core of one fibre to the core of another fibre. In this way there is a minimum of
light lost when the optical signal passes between the fibre ends, and maintaining this
alignment over the operational life of the joint becomes less problematical. In most CCTV
applications, and indeed most other applications, the installer will be concerned with
jointing similar fibre types i.e. 62.5/125 to 62.5/125 fibre.

Today fibre production technology is so reproducible that in most circumstances fibre joints
can be made which rely on aligning the fibre cladding glass on each side of the joint.
However, in every case note that the joint is made with all plastic coatings stripped off of
the glass fibre surface. This can be achieved with proprietary stripping tools, much like
wire strippers, plus the use of chemical cleaners to ensure a clean, grease free surface. It is
also necessary to cut the fibre using a proprietary fibre cleaving tool, so that a fibre end
with a good surface finish is achieved. This cleaving is accomplished by scratching the fibre
surface with a diamond scribe and then causing the fibre to break/cleave by applying a
bending stress to the fibre.

This operation is similar, but obviously much more precise, to scribing and breaking a sheet
of glass. The operations to prepare a fibre for jointing are actually very straight-forward: -

Cut cable to length.
Strip cable sheathing back to fibre secondary coating.
Remove fibre secondary and primary coating.
Cleave fibre to length.
Chemically clean bare fibre end.

The bared fibre end is now ready for jointing using either permanent or de-mountable
joints. In general permanent joints are used to join segments of cable that run over
extended distances and de-mountable connections are used to join short segments of cable
and terminal equipment.

Permanent Joints or Splices

Typically a permanent joint is made when it is necessary to join long lengths of cable. This
form joint is usually made by holding two bared fibre ends together in alignment grooves
and then melting the joint area with an electric discharge. This technique is known as
fusion splicing. Equipment for carrying out fusion splicing can be very expensive because
precision handling of the fibre ends is required. This is particularly the case for single mode
fibre where closer positional tolerance is required than for multi-mode fibre because of the
smaller fibre core diameters.

Fusion splicing gives the lowest connection loss of any jointing technique with joint losses
as low as 0.1 dB being achievable with the best equipment. Following fusion splicing the
welded joint has protective sheathing applied to give the joint mechanical stability.
Typically a fusion splice would be used in jointing a multi-core cable in a cable run where
longer cable lengths are required or where a cable is cut to breakout intermediate
equipment access points.




Page 15 of 15
An alternative to fusion splicing is known as mechanical splicing. Here the two fibre ends
are laid end to end in a precision V groove and the fibres align themselves to their outer
diameter. An index matching fluid is put between the fibre ends to enhance the optical
coupling between the fibres. The aligned fibres are then held in place with mechanical
clamps or they are simply glued in place. As an example one manufacturers splice uses a V
groove in a tubular format, the fibre ends are pushed in from each end of the tube and then
when mated the ends are glued in place in the tube.

These mechanical splices can achieve splice losses in the 0.25 - 0.5 dB range. Typically
mechanical splices would be used to join pre-connected fibre tails to the transmission fibre
with the joints being housed in a readily accessible jointing enclosure or splice tray close to
the terminal equipment.

De-mountable joints/Connectors

De-mountable joints or connectors provide the method for attaching the transmission fibre
to the terminal equipment so that the equipment may be installed or removed as required
without breaking the fibre. This is the optical equivalent of the screw terminal electrical
connector and in fact early connector designs were based on electrical connector designs.

The majority of de-mountable optical connectors use precision ferrules to align the fibre
ends. If we consider the case where we wish to join fibre to fibre, then the alignment
process consists, simply, of putting the bared fibre end into a precision ferrule. i.e. A short
tube which has a hole bored down its centre line, slightly larger diameter than the fibre
cladding glass (and has an O/D of usually 2.5 mm) precisely centred with respect to the
fibre hole. The fibre is glued into the ferrule, with a small length of fibre protruding from
the ferrule end. The glue is cured in a small oven and the fibre end is then polished on an
abrasive pad to be flush with the ferrule end.

Today these ferrules are made from ceramic materials and it is virtually impossible to over-
polish the fibre end. The polished ends of two fibred ferrules are then held together with a
sprung metal alignment cage. A mechanical superstructure around the ferrules is then
used to hold the alignment and enable de-mounting as required. These parts may hold the
joint with either screw fittings or bayonet fittings. Spring loading in the connector shell
ensures that the two ferrule ends are held tightly together but also ensure that the ends
cannot be damaged by over-tightening. In this 2 fibre configuration the two halves of the
connector fit into an in-line or unitor which holds the alignment sleeve. The in-line itself
will have a mounting flange allowing it to be secured into whatever enclosure is being used.

Common connector styles are SMA- screw fitting, STII- bayonet fitting and FC/PC -screw
fitting. In CCTV and data communications applications the STII connector is predominant
and is used for multi-mode fibre jointing. The SMA screw connector is now less common
because of its worse connector performance. The FC/PC connector has come from
telecommunications applications and is commonly used for 1300nm transmission
wavelengths and for single mode fibre connection.










Page 16 of 16
Finally we need to provide a de-mountable connection to terminal equipment in order to
connect the optical transmitters and receivers to the transmission fibre. The equipment
manufacturer may have attached a fibre lead to their LED, laser or photodiode during
manufacture. In this case the manufacturer will have terminated this flying lead with a
connector. This connector, plus an in-line will be mounted on the terminal equipment in
such a way that a connector on the transmission fibre can complete the linkage in the same
way that we described fibre to fibre jointing above.

Alternatively the manufacturer will have assembled the optical component into a receptacle
that has a half an in-line on one side and a holder for the LED/laser/detector package on
the other. The terminated optical fibre is then simply attached to the other side in the usual
way. In either case the equipment manufacturer will have ensured that the user needs only
insert a terminated fibre into their equipment to complete the fibre link.
Page 17 of 17


7 System Implementations

Fibre optics for CCTV applications are predominantly used in extended local installations
linking cameras back to monitors with dedicated fibres for each link. A typical optical
system layout is shown in Fig. 6.























This example illustrates the main features of any fibre optic system, which are as follows:

1. The fibre optic link and its associated terminal equipment fit between the camera and
the associated monitor/controller and provide a transparent signal path i.e. the camera
and controller do not know that the signals have been transmitted over fibre.

2. The camera output is a 1V peak to peak composite video signal.

3. Movable cameras have a telemetry receiver is mounted near to the camera movement
mechanism. This telemetry receiver connects to the system controller to provide control
of the camera pan/tilt and zoom PTZ functions.

4. At the control end of the link camera selection and movement is looked after by the
system controller and video signal outputs from the controller are displayed on a local
monitor(s).

5. Electrical to optical and optical to electrical converters provides the interfaces to the
optical fibre transmission fibre.

6. At the camera end of the link the E/O converter is usually a single channel unit
packaged in a small enclosure which can be conveniently mounted near to the camera or
telemetry receiver. These E/O converters are not usually environmentally sealed and so
need to be protected from the elements often mounting them in the telemetry receiver
enclosure. In their most cost effective form a PTZ E/O converter will use two multimode
fibres to give a uni-directional video connection plus a bi-directional control data

Page 18 of 18
channel.

7. As an alternative these control and video link functions can be carried over a single
fibre using optical transmission at two wavelengths, WDM - wavelength division
multiplexing. These WDM links are more expensive than single wavelength links but
they do save on fibre usage and they also can make the best use of a previously installed
fibre infrastructure.

8. The E/O converter data interface must be compatible with that used by the system
controller; these are often non-standard.

9. Fixed cameras can use a miniature E/O transmitter, which can connect directly to the
camera BNC signal output. This link requires only one fibre.

10. The camera end E/O converter is connected to the transmission fibre through a patch
box. This patch box provides a point of termination for the transmission cable and so
prevents strain and wear and tear being placed on the transmission cable when
installing, servicing or moving the terminal equipment. Optical connections between the
E/O converter and the patch box are made with duplex patchleads (which are short fibre
cable lengths terminated at each end with an optical connector). The patch box will only
be a relatively small enclosure because it will only need to provide connectivity for a few
fibre cores.

11. At the control room end of the link fibres from a large number of cameras will be
concentrated. Equipment must therefore be packaged accordingly and most often this
means the use of 19 rack mount units. E/O converters are manufactured in modular
card format, which enables multiple video channels to be accommodated in a 19 cage.
Typically one 3 U high rack can accept plug-in E/O converters for up to 30 video only
channels or 10 video/data channels (or a mixture of both).

12. The fibre transmission cables are also handled in 19 rack enclosures because now we
will be organising many fibre cores. These enclosures are called patch panels and they
again provide a physical buffer between the transmission cable and the terminal
equipment. Here the cable will be bought into the rear of the patch panel via a
compression gland and the fibre cores will be broken out into the secondary coated
cores. These cores will then be terminated with connectors, which are then connected
into in-line adaptors mounted through the front bulkhead of the patch panel enclosure.
This termination may either be carried out by the direct attachment of connectors to the
fibre tails or factory terminated connectors tails will be spliced to the transmission fibre
cores. If splices are used then the splice enclosures will be mounted in clips on the patch
panel base. Patchleads then connect the patch panel bulkhead connections to the E/O
converter optical connections. Copper leads then complete the connections to the system
controller and monitors.

As part of the cable installation the installer will have measured the installed cable loss,
a function of position using a piece of test equipment called an OTDR (Optical Time
Domain Reflectometer). This measurement serves to finger print the system and
provides a point of reference for future system maintenance. It also provides the value
of the end to end loss of each optical fibre used. The total loss must not exceed the
optical margin specified by the equipment manufacturer, otherwise the transmitted
picture quality may be impaired. In a correctly installed multimode system link lengths
of 4 km for 850nm products and 8 km for 1300nm products are readily achieved.



Page 19 of 19
Finally, a WARNING

LEDs and lasers are very reliable semiconductor devices. However, their output does
change with time and temperature, in particular the variation with time is
unpredictable. It is therefore necessary to accommodate this change of output in the
receiver electronics. While the receiver gain can be set up on installation there can be no
guarantee that this setting will be correct with time. The best equipment uses internal
AGC (Automatic Gain Control) to continuously, and automatically adjust the gain to
give the standard 1V peak to peak signal output. Equipment with an AGC costs more
than equipment without, but this saving is obtained at the expense of the risk of regular
adjustment of the link during its life.