Sunteți pe pagina 1din 7

SIRIUS

3RV1 Motor Starter Protectors

For Motor Protection


3RV10 Class 10 up to 100A

Description

Ordering Information

The 3RV102, 3RV103, and 3RV104 MSPs can be used as Type E self-protected manual combination starters per UL508 (3RV102 and 3RV104 require additional terminal adapers) or as components in Group Installation per NEC 430-53(C) to turn motors on and off. Each device has built-in heater elements that provide overload protection and magnetic trip elements to protect the motor. When the 3RV is used as a component in Group Installation, multiple MSPs can be installed below one circuit breaker to protect its own motor. A contactor can be mounted to the MSP to provide a remotely operated starter.

ON/OFF rotary handle with lockout and visible trip indication. Adjustment dial for setting to motor FLA. Class 10 overload trip characteristics. Short circuit trip at 12 times the maximum setting of the FLA adjustment dial. Short circuit current rating: Ambient compensated up to 140 F (applies to side by side mounting). Phase loss sensitivity. Test trip function. Accessories see pages 1/91/19. General Information see pages 1/311/40. Technical Data see pages 1/201/30. Dimensions see pages 1/35.

Note: Select MSP by motor Full Load Amperes. Horsepower ratings are for reference only.
Instantaneous UL Short-circuit Screw connection short-circuit release breaking capacity @ 480 VAC > List cu A kA Catalog No Price $

Illustration

FLA Adjustment Range

Single-Phase HP Ratings 115V 230V

Three-Phase HP Ratings 200V 230V 460V 575V

3RV102 Frame Size S0


0.110.16 0.140.2 0.180.25 0.220.32 0.280.4 0.350.5 0.450.63 0.550.8 0.71 0.91.25 1.11.6 1.42 1.82.5 2.23.2 2.84 3.55 4.56.3 5.58 710 912.5 1116 1420 1722 2025 1116 1420 1825 2232 2840 3645 4050 2840 3650 4563 5775 7090 80100

1 10 1 8 1 6 1 4 1 3 1 2 1 2 1 1 12 2 2 1 1 12 2 3 3 5 5 3 5 5 7 12 10 10

1 10 1 8 1 6 1 4 1 3 1 2 3 4 1 1 12 2 3 3 3 5 3 3 5 5 7 12 7 12 10 7 12 10 15 15 20 25

1 2 3 4 3 4 1 1 12 2 3 3 5 5 7 12 7 12 5 5 7 12 10 15 15 15 15 15 20 25 30 40

1 2 3 4 1 1 1 12 2 3 3 5 7 12 7 12 7 12 5 7 12 10 10 15 15 20 15 20 25 25 30 40

1 2 3 4 3 4 1 1 12 1 12 2 3 5 5 7 12 7 12 10 15 15 15 10 15 20 25 30 30 40 30 40 50 60 75 75

1 2 1 2 3 4 1 1 12 1 12 2 3 3 5 5 10 10 15 20 20 20 15 20 25 30 40 40 50 40 50 60 75 100 100

2.1 2.6 3.3 4.2 5.2 6.5 8.2 10 13 16 21 26 33 42 52 65 82 104 130 163 208 260 286 325 208 260 325 416 520 585 650 520 650 819 975 1170 1235

65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65

3RV1021-0AA10 3RV1021-0BA10 3RV1021-0CA10 3RV1021-0DA10 3RV1021-0EA10 3RV1021-0FA10 3RV1021-0GA10 3RV1021-0HA10 3RV1021-0JA10 3RV1021-0KA10 3RV1021-1AA10 3RV1021-1BA10 3RV1021-1CA10 3RV1021-1DA10 3RV1021-1EA10 3RV1021-1FA10 3RV1021-1GA10 3RV1021-1HA10 3RV1021-1JA10 3RV1021-1KA10 3RV1021-4AA10 3RV1021-4BA10 3RV1021-4CA10 3RV1021-4DA10 3RV1031-4AA10 3RV1031-4BA10 3RV1031-4DA10 3RV1031-4EA10 3RV1031-4FA10 3RV1031-4GA10 3RV1031-4HA10 3RV1041-4FA10 3RV1041-4HA10 3RV1041-4JA10 3RV1041-4KA10 3RV1041-4LA10 3RV1041-4MA10

3RV103 Frame Size S2

3RV104 Frame Size S3

Select MSP by motor full load amps. Horse power ratings for reference only. Size S0, S2, S3 are listed as type E combination motor controller. Required terminals see page 1/9.

Shaded ratings apply for group installation only. These ratings do not apply as UL listed manual combination starters.

Refer to pages 1/20 to 1/22 when using an MSP in a Manual Motor Starter or a Manual Self-Protected Combination Motor Controller.

Siemens Industry, Inc. Industrial Controls Catalog

Product Category: IEC

1/5

For Motor Protection


3RV10 Class 20 up to 100A
Description

3RV1 Motor Starter Protectors

SIRIUS

Ordering Information

The 3RV103 and 3RV104 MSPs can be used as Type E selfprotected manual combination starters per UL508 (3RV104 requires an additional terminal block) or as components in Group Installation per NEC 430-53(C) to turn motors on and off. (Note: the 3RV104 requires the line side adapter 3RT19464GA07 to meet the Type E.) Each device has built-in heater elements that provide overload protection and magnetic trip elements to protect the motor. When the 3RV is used as a component in Group Installation, multiple MSPs can be installed below one circuit breaker to protect its own motor. A contactor can be mounted to the MSP to provide a remotely operated starter.

ON/OFF rotary handle with lockout and visible trip indication. Adjustment dial for setting to motor FLA. Class 20 overload trip characteristics. Short circuit trip at 12 times the maximum setting of the FLA adjustment dial. Short circuit current rating: Ambient compensated up to 140 F (applies to side by side mounting). Phase loss sensitivity. Test trip function. Auxiliaries and Accessories see pages 1/91/19. General Information see pages 1/311/40. Technical Data see pages 1/201/30. Dimensions see page 1/35.

Note: Select MSP by motor Full Load Amperes. Horsepower ratings are for reference only.
Instantaneous UL Short-circuit Screw connection short-circuit release breaking capacity @ 480 VAC > List cu A kA Catalog No Price $

Illustration

FLA Adjustment Range

Single-Phase HP Ratings 115V 230V

Three-Phase HP Ratings 200V 230V 460V 575V

3RV103
1116 1420 1825 2232 2840 3645 4050 1 1 12 2 3 3 5 5 3 3 5 5 7 12 7 12 10 5 5 7 12 10 15 15 15 5 7 12 10 10 15 15 20 10 15 20 25 30 30 40 15 20 25 30 40 40 50 208 260 325 416 520 585 650 65 65 65 65 65 65 65 3RV1031-4AB10 3RV1031-4BB10 3RV1031-4DB10 3RV1031-4EB10 3RV1031-4FB10 3RV1031-4GB10 3RV1031-4HB10

3RV104
2840 3650 4563 5775 7090 80100 3 5 5 7 12 10 10 7 12 10 15 15 20 25 15 15 20 25 30 40 15 20 25 25 30 40 30 40 50 60 75 75 40 50 60 75 100 100 520 650 819 975 1170 1235 65 65 65 65 65 65 3RV1042-4FB10 3RV1042-4HB10 3RV1042-4JB10 3RV1042-4KB10 3RV1042-4LB10 3RV1042-4MB10

Shaded ratings apply for group installation only. These ratings do not apply as UL listed manual combination starters.

Refer to pages 1/20 to 1/22 when using an MSP in a Manual Motor Starter or a Manual Self-Protected Combination Motor Controller application.

1/6

Product Category: IEC

Siemens Industry, Inc. Industrial Controls Catalog

SIRIUS
Selection and ordering data
Type Design

3RV1 Motor Starter Protectors

Auxiliaries and Accessories

For SIRIUS MSP Frame Size S00, S0, S2, S3

Screw connection Order No. List Price $ 3RV19 01-1D 3RV19 01-1E 3RV19 01-1F 3RV19 01-1G

Weight approx. kg 0.02

Auxiliary switches 1)
3RV19 01-1E Transverse auxiliary switch 2) with screw connection Solid-state compatible, SPDT contact transverse auxiliary switch 2) with screw connection for use in dusty atmosphere and in electronic circuits with low operating currents Covering caps for transverse auxiliary switches S00, S0, S2, S3 0.02 SPDT contact 1 NO + 1 NC 2 NO

3RV1901-1G

3RV1901-0H

3RV1901-1A 3RV1901-1J

S00, S0, S2, S3

3RV19 01-0H Standard package quantity=10

Lateral auxiliary switches 1 NO + 1 NC with screw connection 2 NO (Side Mount) 2 NC 2 NO + 2 NC

S00, S0, S2, S3

3RV19 01-1A 3RV19 01-1B 3RV19 01-1C 3RV19 01-1J

0.03

0.06

Signalling switch 3)
3RV19 21-1M Signaling switch (Side Mount) Individual tripped and short-circuit signaling, 1 NO + 1 NC each S0, S2, S3 3RV19 21-1M 0.07

Auxiliary releases 4)
3RV19 02-1DP0 Undervoltage release (Side Mount) DC

24 V AC 50 Hz 20-24 V 90-110 V 210-230 V 400 V 350-415 V 500 V 230 V 400 V 415 V 230 V 400 V 415 V AC 50/60 Hz 100% ON 5) AC 60 Hz 120 V 208 V 240 V 480 V 240 V 480 V 240 V 480 V

S00, S0, S2, S3 S00, S0, S2, S3

3RV19 02-1AB4 3RV19 02-1AB0 3RV19 02-1AF0 3RV19 02-1AM1 3RV19 02-1AP0 3RV19 02-1AV0 3RV19 02-1AV1 3RV19 02-1AS0 3RV19 12-1CP0 3RV19 12-1CV0 3RV19 12-1CV1 3RV19 22-1CP0 3RV19 22-1CV0 3RV19 22-1CV1

0.12 0.12

3RV19 12-1CP0 Undervoltage release with leading auxiliary contacts 2 NO (Side Mount)

S00

0.11

S0, S2, S3

AC 50/60 Hz; DC 5 sec ON 6) 20 70 V 70190 V 190330 V 330500 V 500 V S00, S0, S2, S3 3RV19 02-1DB0 3RV19 02-1DF0 3RV19 02-1DP0 3RV19 02-1DV0 3RV19 02-1DS0 0.11

Shunt release (Side Mount)

20 24 V 90110 V 200240 V 350415 V 500 V

Terminals for "Combination Motor Controller Type E" to UL 508


3RV19 28-1H Note: As of July 2001, UL 508 demands for "Combination Motor Controller Type E" 1" air gaps and 2" creepage distances at lineside. The following terminal blocks must be used in S0 and S3 MSPs 3RV10. The S2 MSP 3RV10 conforms with stipulated air gaps and creepage distances without terminal block. Terminal blocks are not required for use according to CSA. With size S0 these terminal blocks cannot be used in combination with 3-phase busbars 3RV19.5. This also applies to size S3 in combination with transverse auxiliary switches. Terminal block type E 3RT19 46-4GA07 for extended air/ creepage distance (1" and 2") S0 S3 3RV19 28-1H 3RT19 46-4GA07 0.12 0.12

1) Each MSP can be fitted with one transverse and one lateral auxiliary switch. The lateral auxiliary switch with 2 NO + 2 NC is used without transverse auxiliary switch. 2) Compatible with the following MSPs: 3RV1. 1 (size S00) as of version E01 3RV1. 2 (size S0) as of version E04 3RV1. 3 (size S2) as of version E04 3RV1. 4 (size S3) as of version E04.

3) One signaling switch can be mounted at the left of each MSP. 4) One auxiliary release can be mounted at the right side of each MSP. 5) The response voltage at the lower limit of the voltage range at 0.85 (Tu = 60 C) is valid for 100 % (infinite) duty cycle only at AC 50/60 Hz. 6) The response voltage at the lower limit of the voltage range at 0.9 (Tu = 60 C) applies for a duty cycle of 5 seconds at AC 50/60 Hz and DC.

Siemens Industry, Inc. Industrial Controls Catalog

Product Category: IEC

1/9

Busbar Accessories
Accessories for Busbar
Selection and ordering data
Modular spacing

3RV1 Motor Starter Protectors

SIRIUS

Number of motor starter protectors that can be connected Without lateral accessories Incl. lateral auxiliary switch With auxiliary trip unit

Rated current In at 690 V

For motor starter protectors Size

Order No.

List Price $

PU PS (UNIT, SET, M)

Weight per PU approx.

mm

kg

Three-phase busbar systems


For feeding several motor starter protectors with screw terminals, mounted side-by-side on standard mounting rails, insulated, with touch protection. 45 2 3 4 5 ---63 S00, S01)2) S00, S01)2) S00, S01)2) S00, S01)2) S00, S01)2) S00, S01)2) S00, S01)2) S00, S01)2) S00, S01)2) S00, S01)2) S2 S2 S2 S23) S23) S23)
2) 3)

3RV19 15-1AB

3RV19 15-1AB 3RV19 15-1BB 3RV19 15-1CB 3RV19 15-1DB 3RV19 15-2AB 3RV19 15-2BB 3RV19 15-2CB 3RV19 15-2DB 3RV19 15-3AB 3RV19 15-3CB 3RV19 35-1A 3RV19 35-1B 3RV19 35-1C 3RV19 35-3A 3RV19 35-3B 3RV19 35-3C

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit

0.044 0.071 0.099 0.124 0.048 0.079 0.111 0.140 0.052 0.120 0.150 0.214 0.295 0.161 0.262 0.369

3RV19 15-1BB

55

2 3 4 5 ---

--

63

3RV19 15-1CB

63 55

-2 3 4 --

2 4 --

63 108

3RV19 15-1DB

75

2 3 4

2 3 4

108

1)

Not suitable for 3RV11 motor starter protectors with overload relay function. Common clamping of S00 and S0 motor starter protectors is not possible, due to the different modular spacings and terminal heights. The 3RV19 15-DB connecting piece is available for connecting busbars from size S0 to size S00. Version Modular spacing For motor starter protectors Size

Not suitable for 3RV17 and 3RV18 circuit breakers. Auxiliary trip units and lateral auxiliary switches cannot be used in combination.

Order No.

List Price $

PU PS* (UNIT, SET, M)

Weight per PU approx. kg

mm

Connecting pieces for three-phase busbars


For connecting three-phase 45 busbars for motor starter protectors of size S0 (left) to size S00 (right) S00, S0 3RV19 15-5DB 1 1 unit 0.042

3RV19 15-5DB

Conductor cross-section Solid or Finely stranded stranded with end sleeve mm mm

Tightening torque AWG cables, solid or stranded Nm

For motor starter protectors Size

Order No.

List Price $

PU PS* (UNIT, SET, M)

Weight per PU approx.

AWG

kg

Three-phase feeder terminals


Connection from top 2.5 ... 25 4 ... 16 12-4 4 S00 S0 3RV19 25-5AB Connection from below1) 2.5 ... 25 4 ... 16 12-4 Input: 4, Output: 2 ... 2.5 4 S00, S0 3RV19 15-5B 1 1 unit 0.110 3RV19 15-5A 3RV19 25-5AB 1 1 1 unit 1 unit 0.040 0.041

Connection from top 2.5 ... 50 1.5 ... 35 14-0 3RV19 15-5B S2 3RV19 35-5A 1 1 unit 0.110

Three-phase feeder terminals for constructing "Type E Starters"


Connection from top 2.5 ... 25 4 ... 16 10 ... 50 -1)

10-4 8-0

2-4 4.5-6

S0 S2

3RV19 25-5EB 3RV19 35-5E

1 1

1 unit 1 unit

0.055 0.100

This terminal is connected in place of a switch, please take the space requirement into account.

1/10

Product Category: IEC

Siemens Industry, Inc. Industrial Controls Catalog

SIRIUS
Selection and ordering data
Type

3RV1 Motor Starter Protectors

Accessories

Accessories for MSP with cage clamp connection

Design

Order No.

List Price $

Weight approx. kg

Std. pkg. qty

Transverse auxiliary switch with Cage Clamp connection 1)


1 NO + 1 NC 3RV19 01-2E 0.02

Laterally mountable auxiliary switch with Cage Clamp connection


Laterally mounted auxiliary switch to be mounted on the left side of the MSP 1 NO + 1 NC 2 NO 2 NC 3RV19 01 -2A 3RV19 01 -2B 3RV19 01 -2C 0.03

Adapter and link module for Cage Clamp connection


3RA1911-2A + 8US1051-5CM47 Link module, Cage Clamp for electrical contacting between MSP and contactor (busbar adapter not included in the scope of delivery) Link module, Cage Clamp, for mechanical fixing for mechanical fixing and electrical contacting between MSP and contactor Adapter for rail mounting for Cage Clamp with 2 mounting rails, one adjustable Busbar adapter 45 mm wide, 182 mm long adapted for Cage Clamp MSP. An additional standard mounting rail must be used if increased protection is required. 35 mm standard mounting rail, plastic, includes fixing screws Size S00 3RA19 11-2A 0.12 10

3RA1911-2E

Size S00

3RA19 11-2E

0.03

10

45 mm wide

3RA19 22-1L

0.26

60 mm wide

8US12 51-5CM47

0.17

45 mm wide

8US19 98-7CA15

0.09

10

Tool for opening Cage Clamp connection


for all SIRIUS devices with Cage Clamp connection, conductor cross-section max. 2.5 mm2 Length approx. 175 mm 8WA2 8032) 0.012

1) Compatible with the following MSPs: 3RV1. 1 (size S00) as of version E01 3RV1. 2 (size S0) as of version E04 3RV1. 3 (size S2) as of version E04 3RV1. 4 (size S3) as of version E04 2) Discount Code: Terminal Blocks

Siemens Industry, Inc. Industrial Controls Catalog

Product Category: IEC

1/11

Accessories

3RV1 Motor Starter Protectors

SIRIUS

Mounting accessories
Selection and ordering data
Type Design For SIRIUS MSP size Order No. List Price $ Standard Weight Package approx. Quantity kg

Mounting accessories
3RB19 00-0B Push-in lugs For screwing the MSP onto S00, S0 mounting plates. 2 units required per MSP. 3RB19 00-0B 10 0.01

Solder pin connection


3RV19 18-5A with circuit-breaker for main contacts For soldering the main conductor connections of a MSP to a S00 printed-circuit board. (Quantity 4 = 8 parts for 4 MSPs) For soldering the main conductor S00 connections and the auxiliary conductor connections of the transverse auxiliary switch (1 NO + 1 NC) of a MSP to a printedcircuit board. (Quantity 4 = 8 parts for main conductor connection + 4 parts for auxiliary conductor connection for 4 MSPs) 3RV19 18-5A 4 0.10

for main and auxiliary contacts

3RV19 18-5B

0.19

Isolator module
3RV19 38-1A with padlock Isolator module Visible isolating distance for S0 isolating individual MSP from the network, lockable in isolating position S2 3RV19 28-1A 0.15

3RV19 38-1A

0.29

Auxiliary terminal, 3-pole


3RT19 46-4F For connection of auxiliary and control cables to the main conductor connections S3 3RT19 46-4F 0.10

Link modules
Contactor 3RA19 11-1AA00 Link module for mechanical fixing and electrical contacting between contactor and MSP AC and DC AC and DC AC AC AC DC DC DC S00 S00 S0 S2 S3 S0 S2 S3 MSP S00 S0 S0 S2 S3 S0 S2 S3 3RA19 11-1AA00 3RA19 21-1DA00 3RA19 21-1AA00 3RA19 31-1AA00 3RA19 41-1AA00 3RA19 21-1BA00 3RA19 31-1BA00 3RA19 41-1BA00 0.03 0.03 0.04 0.05 0.08 0.04 0.05 0.08

3RA19 31-1AA00

Hybrid link modules, single-unit packaging


Electrical and mechanical connection between motor starter protector with screw terminals and contactor with Cage Clamp terminals AC/DC S00 S00 S00 S0 3RA19 11-2FA00 3RA19 21-2FA00 1 1 0.038 0.028

3RA19 11-2FA00

1/12

Product Category: IEC

Siemens Industry, Inc. Industrial Controls Catalog

SIRIUS
Selection and ordering data
Type Design

3RV1 Motor Starter Protectors

Accessories

Rotary operating mechanisms

For SIRIUS MSP size

Order No.

List Price $

Weight approx. kg

Door-coupling rotary operating mechanisms


3RV19 26-0B The door-coupling rotary operating mechanisms consist of a knob, a coupling driver and an extension shaft of 330 mm length (6 mm 6 mm). The door-coupling rotary operating mechanisms are designed for degree of protection IP 65. The door locking device prevents accidental opening of the cubicle door in the ON position of the MSP. The OFF position can be locked with up to 3 padlocks. Door-coupling Extension shaft 130 mm rotary operating mech- Extension shaft 330 mm anism, black with supporting bracket EMERGENCY STOP Extension shaft 130 mm door-coupling Extension shaft 330 mm rotary operating mech., with supporting bracket red/yellow S0, S2, S3 3RV19 26-0B 3RV19 26-0K 0.1 0.3

3RV19 26-0C 3RV19 26-0L

0.1 0.3

Door-coupling rotary operating mechanisms for heavy duty conditions


3RV19 26-2C The door-coupling rotary operating mechanisms consist of a knob, a coupling driver, an extension shaft of 300 mm length (8 mm 8 mm), a spacer and two metal brackets, into which the MSP is inserted. The door-coupling rotary operating mechanisms are designed for degree of protection IP 65. The door locking device reliably prevents accidental opening of the cubicle door in the ON position of the MSP. The OFF position can be locked with up to 3 padlocks. Auxiliary releases for lateral mounting and 2-pole auxiliary switches can be used. The door-coupling rotary operating mechanism thus conforms with isolator characteristics to IEC 60 947-2. Door-coupling rotary operating mechanism, grey EMERGENCY STOP door-coupling rotary operating mech., red/yellow S0 S2 S3 S0 S2 S3 3RV29 26-2B 3RV29 36-2B 3RV29 46-2B 3RV29 26-2C 3RV29 36-2C 3RV29 46-2C 1.2 1.6 1.7 1.2 1.5 1.7

Remote-controlled motor-driven mechanisms


3RV19 26-0K Remote-controlled motorized operating mechanism AC 50/60 Hz, 230 V DC 24 V AC 50/60 Hz, 230 V DC 24 V S2 S3 3RV19 36-3AP0 3RV19 36-3AB4 3RV19 46-3AP0 3RV19 46-3AB4 3.5 3.4 3.4 3.4

Mounting accessories
Selection and ordering data
Type Design For circuitbreaker size Order No. List Price $ Weight approx. kg

Covers
3RV1 (size S3) with 3RT19 46-4EA1 Terminal cover for box terminals Additional touch guard to be fitted at the box terminals S2 (2 units can be mounted per S3 MSP) For maintaining the required voltage clearance and as protec- S3 tion against the equipment being touched if distant box terminals are used (2 units can be mounted per MSP) 3RT19 36-4EA2 3RT19 46-4EA2 0.01

Terminal cover for cable lug and bar connection

3RT19 46-4EA1

0.03

3RV19 08-0P

Scale cover sealable

For covering the current setting scale. Packing unit: Bag with 10 scale covers (Order No. and price per bag)

S00, S0, S2, S3

3RV19 08-0P Standard package quantity=10

Siemens Industry, Inc. Industrial Controls Catalog

Product Category: IEC

1/13

S-ar putea să vă placă și