HighPROTEC MRA4

Protection Technology made simple


Protection Relay for Feeder, Grid and Generator Applications
Disturbance recorder 120 s non volatile, 32 samples per cycles Additional highlights Automatic reclosing Inrush Thermal replica Four stages external protection Plausibility checks Adaptive parameter sets Energy counters Status display Comprehensive measured values and statistics Masking of unused functions Parameter setting support by software Copy parameter sets Compare parameter sets Setting files are up and down convertible (across versions) Four stages earth fault protection Directional and non-directional earth fault protection Tripping characteristic: DEFT ANSI: NINV, VINV, EINV IEC: NINV, VINV, LINV, EINV Thermal Flat, IT, I2T, I4T Voltage controlled Two stages unbalanced load protection Supervision by definite time or tripping characteristic Four stages voltage protection Under- and overvoltage Programmable undervoltage time depending characteristic Two stages residual voltage protection VE> Six stages voltage asymmetry supervision Under- and overvoltage in positive phase sequence system, overvoltage in negative phase sequence system Comprehensive frequency protection package Each of the six stages can be used as: f< or f> (over- and underfrequency supervision) df/dt (ROCOF) Rate of change of frequency (f< and df/dt) or (f> and df/dt) combination of over-, under and rate of change of frequency (ROCOF) (f< and DF/DT) or (f> and DF/DT) combination of over-, under and increase of frequency Delta Phi (Vector surge) Power protection package Six stages power protection Each can be used as P>, P<, Pr, Q>, Q<, Qr, S>, S< Two stages power factor (PF) Supervision Current transformer supervision Voltage transformer supervision Circuit breaker failure protection Trip circuit supervision Cold load pickup Switch onto fault

Application

The MRA4 is a protection relay which uses the latest Dual-Core-Processor Technology to provide precise and reliable protective functions and is very easy to operate. Its various protective functions are specifically tailored to the protection of incoming and outgoing feeders in MV systems. It also can be used for grid and generator protection. All inclusive: All protection features without extra charge Parameter setting and evaluation software Disturbance record analysis software Six stages phase overcurrent protection Directional and non-directional overcurrent/short-circuit protection Tripping characteristics: DEFT ANSI: NINV, VINV, EINV IEC: NINV, VINV, LINV, EINV Thermal Flat, IT, I2T, I4T Voltage controlled

Functional Overview
PRotEctIVE FUNctIoNs
I, time overcurrent and short circuit protection, all stages can be configured for directional or non-directional supervision. Tremendous reset options (instantaneous, definite time, reset characteristics according to IEC and ANSI). Voltage controlled overcurrent protection by means of adaptive parameters. I2>, unbalanced load protection with evaluation of the negative phase sequence currents IB, overload protection with thermal replica and separate pick-up values for alarm and trip functions IH2/In, inrush detection with evaluation of the 2nd harmonic IE, earth overcurrent and short circuit protection, all stages can be configured for directional or nondirectional supervision. Tremendous reset options (instantaneous, definite time, reset characteristics according to IEC and ANSI). Voltage controlled overcurrent protection by means of adaptive parameters. V<, V>, V(t)<, under- and overvoltage protection, time dependent undervoltage protection Voltage asymmetry supervision (V012) V1, under and overvoltage in positive phase sequence system V2, overvoltage in negative phase sequence system Each of the six frequency protection stages can be used as: f< or f> (over- and under frequency supervision) df/dt rate of change of frequency (ROCOF) (f< and df/dt) or (f> and df/dt) combination of over-, under- and rate of change of frequency (ROCOF) (f< and DF/DT) or (f> and DF/DT) combination of over-, under- and increase of frequency Delta Phi (Vector surge) VE, residual voltage protection AR, automatic reclosing ExP, External alarm and trip functions PQS, Power protection PF, Power factor 2 1 4 6 2 32, 37 55 78 59N 79

Elements
6

ANSI
50P, 51P, 67P

6 2 1 1 4

51V 46 49 Inrush 50N,51N, 67N

4 4 6 6

51V 27, 59 47

81U/O 81R

SUpERVIsIoN fUNctIoNs
CBF, circuit breaker failure protection TCS, trip circuit supervision VTS, voltage transformer supervision by comparing phase and residual voltages VTS, fuse failure protection via digital input CTS, current transformer supervision CLPU, cold load pickup SOTF, switch onto fault Non volatile event recorder up to 120 s with 32 samples per cycles

Elements
1 1 1 1 1 1 1

ANSI
50BF 74TC 60FL 60FL 60L

Functional overview in ANSI form


MRA4

79

74 TC

46

49

Inrush

50 BF

50P

51P

67P

67N

Measured and calculated values


delta phi, theta , IH2,

V, VE, V012, I, IG, f, IGH2, I012, P, Q, S, PF, cos phi, W Fault recorder Event recorder

3 1

37 32 47 60L 55

SOTF

CLPU

4 27 59 59N 60 FL 81 U/O 81R 50N 51N 51V 78

Disturbance recorder

Connections

Order form MRA4


Directional Feeder Protection
Digital Inputs 8 16 Binary output relay 7 13 Housing B2 B2 Large display A D 0 A B A B C F G

MRA4

Hardware variant 2 Standard Housing and mounting Door mounting Door mounting 19 (flush mounting) Communication protocol Protocol/without protocol RS485/terminals, Modbus RTU, IEC60870-5-103 Ethernet (RJ45), Modbus TCP, IEC61850* prepared (Hardware/Interface) Optic fiber, Modbus RTU, IEC60870-5-103 RS485/D-SUB, Profibus**, Modbus RTU, IEC60870-5-103 Presetting of available menu languages Standard English/German
* Additional cost for the software update tool IEC61850 per device are 250 . The devices can be updated via device front interface (RS232) and PC locally Expected availability: 01.01.2010 **expected 07.09

Current inputs Voltage inputs Digital Inputs Power supply Terminals Mounting Type of enclosure Dimensions of housing Weight (max. components)

4 (1 A and 5 A) with automatic short circuiters 4 (0 - 800 V) Switching thresholds adjustable via software Wide range power supply All terminals plug type Door mounting IP54 212.7 mm x 173 mm x 209 mm (W x H x D) approx. 4 kg

Woodward SEG GmbH & Co. KG Krefelder Weg 47 D - 47906 Kempen Sales Team Phone: +49 (0) 21 52 1 45 - 1 Fax.: +49 (0) 21 52 1 45 - 3 54 e-mail: kemp.electronics@woodward.com
DOK_FLY_MRA4_04.09_EN

Service Telefon: +49 (0) 21 52 1 45 - 6 14/3 34 Fax.: +49 (0) 21 52 1 45 - 4 55 e-mail: kemp.pd@woodward.com

Visit us at www.eps.woodward.com

Enabling Electrical Power Systems Integration