Refrigerant Recovery
MSE-ToT-Recovery-Final-Dec01.ppt 2
Aspects covered
Necessity
Principles
Procedures
Making a machine
MSE-ToT-Recovery-Final-Dec01.ppt 3
Refrigerant Recovery-
What and Why?
Recover
CFCs & HCFCs
because they destroy
ozone and cause
climate change
HFCs
because they cause
climate change
MSE-ToT-Recovery-Final-Dec01.ppt 4
Recovery Machine
with Condenser
Compressor
Condenser
Evaporator
Expansion
Valve
Receiver
Compressor
Manifold
Condenser
MSE-ToT-Recovery-Final-Dec01.ppt 5
Recovery Machine
without Condenser
Compressor
Condenser
Compressor
Receiver
Manifold
Expansion
Valve
Evaporator
MSE-ToT-Recovery-Final-Dec01.ppt 6
A Typical Recovery System
Piercing
Plier
Recovery Machine
Recovery
Cylinder
Weighing
Balance
Appliance
MSE-ToT-Recovery-Final-Dec01.ppt 7
Recovery Cylinder
Do not use disposable
cylinders
Fill up to 80% of
Cylinder Capacity
Do not mix the
refrigerant cylinders
Label the cylinders
MSE-ToT-Recovery-Final-Dec01.ppt 8
Recovery Procedure
Connect appliance to recovery machine inlet
Connect recovery machine outlet to cylinder
Weigh cylinder
Open valves and start machine
Recover until:
2 psig, if appliance is serviced
as low as possible, if appliance is scrapped
Stop machine and close valves
MSE-ToT-Recovery-Final-Dec01.ppt 9
International Experience
In many countries, law doesnt permit venting
of refrigerants
Refrigerants have to be recovered and recycled
or recovered and destroyed
Most R&R systems are certified
In developed countries:
Most CFCs, HCFCs & HFCs are recovered
Most technicians have/ share recovery
machines
There exist many recycling centres
MSE-ToT-Recovery-Final-Dec01.ppt 10
Recycling, Reclamation
and Destruction
Uncontaminated
refrigerant can be
reused
Contaminated
refrigerant can be
recycled, but you need
recycling centres
or
recycling machine
MSE-ToT-Recovery-Final-Dec01.ppt 11
Components required
Assembling the machine
Operation
Maintenance and reliability
Making a Recovery Machine
MSE-ToT-Recovery-Final-Dec01.ppt 12
Components needed
condensing unit
pressure switches
shut off valves
fittings and pipings
on / off switch
drier
MSE-ToT-Recovery-Final-Dec01.ppt 13
Components needed
MSE-ToT-Recovery-Final-Dec01.ppt 14
Recovery Machine Assembly
MSE-ToT-Recovery-Final-Dec01.ppt 15
A recovery machine
made in India
MSE-ToT-Recovery-Final-Dec01.ppt 16
Wiring Diagram
MSE-ToT-Recovery-Final-Dec01.ppt 17
Pressure Switch Settings
LP switch:
-0.3 bar (4 psig) cut-out
1.0 bar (15 psig) differential
HP switch
20 bar (290 psig) : for HCFC22
15 bar (220 psig) : for CFC12/HFC134a
MSE-ToT-Recovery-Final-Dec01.ppt 18
Operation & Maintenance
Have separate recovery machine for
each refrigerant
Use with correct refrigerant
Do not allow liquid into machine
MSE-ToT-Recovery-Final-Dec01.ppt 19
Maintenance & Reliability
Replace filter drier after maximum 100
hours of operation
Check whether the compressor is
working properly, before using it