Sunteți pe pagina 1din 4

SAP Note

63347 - List: CPIC error codes


Version 11 Validity: 26.11.2008 - active

Language English

Header Data
Released On
Release Status
Component

01.12.2008 14:13:48
Released for Customer
BC-CST-GW Gateway/CPIC

Other Components BC-NET Network Infrastructure


Priority
Category

Recommendations / Additional Info


Help for error analysis

Symptom
This note concerns error analysis in the network environment and CPIC return codes in particular.
The meaning of the return code numeric values is unclear.

Other Terms
Error, return codes, SAP-RC, CPIC-RC

Reason and Prerequisites


Solution
CPIC return codes (not SAP-specific)
CM_OK0
CM_ALLOCATE_FAILURE_NO_RETRY1
CM_ALLOCATE_FAILURE_RETRY2
CM_CONVERSATION_TYPE_MISMATCH3
CM_SECURITY_NOT_VALID6
CM_SYNC_LVL_NOT_SUPPORTED_PGM8
CM_TPN_NOT_RECOGNIZED9
CM_TP_NOT_AVAILABLE_NO_RETRY10
CM_TP_NOT_AVAILABLE_RETRY11
CM_DEALLOCATED_ABEND17
CM_DEALLOCATED_NORMAL18
CM_PARAMETER_ERROR19
CM_PRODUCT_SPECIFIC_ERROR20
CM_PROGRAM_ERROR_NO_TRUNC21
CM_PROGRAM_ERROR_PURGING22
CM_PROGRAM_ERROR_TRUNC23
CM_PROGRAM_PARAMETER_CHECK24
CM_PROGRAM_STATE_CHECK25
CM_RESOURCE_FAILURE_NO_RETRY26
CM_RESOURCE_FAILURE_RETRY27
CM_UNSUCCESSFUL28
CM_OPERATION_INCOMPLETE35
CM_SYSTEM_EVENT 36
Gateway error codes
CPIC_ERROR221 Error in the CPIC interface
CANT_GET_MEMORY222 Memory bottleneck
NI_READ_FAILED223 Network read error
NI_WRITE_FAILED224 Network write error
INVALID_REQUEST225 Invalid request
NOT_YET_CONNECTED226 Not yet connected
GW_WP_DIED227 Gateway process died
SHM_READ_FAILED228 Shared memory problem (read)
SHM_WRITE_FAILED229 Shared memory problem (write)
NO_MORE_LU230 No available LU
NO_MORE_WP231 No available gateway process
CANT_START_WORKPROCESS232 Error when starting the gateway process
WRONG_COMM_TYPE233 Wrong communication type
CONNECT_FAILED234 Connection setup failed
COMM_TABLE_ERROR235 Error in comm. table
GW_CONNECT_FAILED236 No connection to the gateway
GW_DISCONNECTED237 Connection to the gateway disconnected
WRITE_TO_GW_FAILED238 Error with GW comm. (write)
READ_FROM_GW_FAILED239 Error with GW comm. (read)
INVALID_LEN240 Invalid length
INVALID_ENVIRONMENT 241 Invalid environment
GW_TIMEOUT242 Timeout
GW_CONNECT_TO_R3243 Error when setting up R/3 connection
SYSTEM_DISCONNECTED244 Partner disconnected connection

MEM_OVERFLOW245 Memory overflow


WRONG_APPCHDR_VERSION 246 Incorrect APPC header version
GW_APPC_SERVER_DOWN247 Loc. gateway not started
TXCOM_TABLE_FAILED248 Error when accessing TXCOM
COMM_TABLE_OVERFLOW 249 Comm. table full
C_NO_MEM450 No memory
C_NO_SIDE_INFO451 No SIDE INFO entry
C_TP_START452 TP-START failed
C_NO_INIT453 No initialization
C_GETLU454 "getlu" failed
C_SIGNAL455 "signal" failed
C_TIMEOUT456 Timeout when establishing connection
C_ALLC457 CMALLC failed
C_SEND458 CMSEND failed
C_PREPARE459 Prepare-To-Receive failed
C_FLUSH460 CMFLUS failed
C_RECEIVE461 CMRCV failed
C_NO_ARGUMENT462 Missing argument
C_GET_ALLOCATE463 "get_allocate" failed
C_DEAL464 CMDEAL failed
C_TP_END465 TP-END failed
C_MAX_CONV466 Max. number conv. reached
C_SNAOPEN467 "snaopen" failed
C_SNACTL468 "snactl" failed
C_NO_FLUSH469 No flush in IBM environment
C_SNACLSE470 "snaclse" failed
C_STATE_CHECK471 Status error
C_NO_SIDE_INFO_ENTRY472 No side info entry
C_NO_CONV473 No conversation
C_MANUAL_CANCELD474 Connection manually cancelled
C_AUTO_CANCELD475 Connection automatically cancelled
C_NO_PARTNER476 No partner found
C_CONFIRM477 Confirm failed
C_CONFIRMED478 Confirmed failed
C_NO_HOST_IN_SIDE_INFO479 GWHOST not in side info entry
C_NO_SERV_IN_SIDE_INFO480 GWSERV not in side info entry
C_NO_PROT_IN_SIDE_INFO481 PROTOCOL not in side info entry
C_NO_LU_IN_SIDE_INFO482 LU not in side info entry
C_NO_TP_IN_SIDE_INFO483 TP not in side info entry
C_NO_GATEWAY_CONNECTION 484 No connection to the gateway
C_GETHOSTNAME485 gethostname failed
C_NO_SAP_CMACCP486 SAP_CMACCP not executed
C_NO_PROGRAM_NAME_ARG 487 Program not in arg. list
C_NO_HOST_ARG488 Host not in arg. list
C_NO_SERV_ARG489 Service not in arg. list
C_NO_CONVID_ARG490 Conv. ID not in arg. list
C_ILLEGAL_PARAMETER 491 Illegal parameter
C_LU62CVCT492 LU62CVCT failed
C_LU62ATTACH493 LU62ATTCH failed
C_NO_CONV_TABLE494 No conv. table
C_ILL_CONV_TABLE495 Incorrect conv. table
C_ILL_MOD_VALUES496 Invalid conv. modification
C_NIHOSTTOADDR497 NiHostToAddr failed
C_NIADDRTOHOST498 NiAddrToHost failed
C_THOST_FAILED499 Reading table THOST failed
INVALID_MODE630 Invalid mode number received
MAX_NO_OF_GATEWAYS631 Max. no. of gateways reached
MISSING_LU_SPEC632 No LU specified
MAX_CPIC_CLIENTS633 Max. no. of clients reached
BAD_TPNAME634 Invalid TP name
FORK_FAILED635 Fork failed
BAD_NI_HANDLE636 Invalid NI handle
REXEC_FAILED637 rexec failed
TP_START_FAILED638 Starting the TPs failed
NI_DG_SEND_FAILED639 NiDgSend failed
INTERNAL_ERROR640 Internal error
GW_HOST_UNKNOWN664 Gateway host unknown
GW_SERVICE_UNKNOWN665 Gateway service unknown
GW_NI_ERROR666 NI error
GW_EXEC_FAILED667 exec failed
R2_RESTARTED668 R/2 restarted
SYM_DEST_TOO_LONG669 Symb. destination too long
NO_MORE_SIDE_INFO_ENTRY 670 No more side info entries
R3_LOGIN_FAILED672 R/3 Login failed
IMS_ERROR_PURGING673 IMS error purging
PENDING_TERM_OUTPUT674 Timeout of reg. programs
GW_SECURITY_ERROR676 TP not registered
GW_TIMEOUT_REG_PRGM677 Timeout of registered program
TP_REGISTERED678 TP is registered
TP_NOTREGISTERED679 TP not registered
TP_REG_SECU_ERROR720 Security violation for reg. prgrms
GW_SNC_DISABLED721 SNC deactivated
GW_SNC_REQUIRED722 SNC required
GW_SNC_NAME_NOT_SET 723 SNC name not defined
GW_SNC_NAME_NO_DEFAULT724 Default SNC name not permitted
GW_SNC_PROT_NOT_SUPP725 Log does not support SNC
GW_R3_NOT_CONNECTED726 No local R/3 system
GW_SNC_REQUIRED_FOR_LU_TP 727 SNC required
CONV_ID_NOT_FOUND728 Conversation ID not found
GW_SNC_SECURE_PORT729 Comm. must make SNC

GW_SNC_START_EXT_DIS730 Start of ext. Program deactivated


GW_SHUTDOWN731 Gateway was shut down
GW_REM_PRGM_DISABLED732 No external programs
GW_STOLEN_CONVID733 Conversation ID does not fit
GW_NET_CONV_ERROR 734 Net Conv Error
GW_MONITOR_DISABLED 735 Monitor not active
GW_DUPLICATE_CVID736 Conv. ID not unique
GW_CONNECT_TIMEOUT737 Timeout of connection setup to remote system
GW_REQ_TO_DP_FAILED738 Request could not be transferred to the dispatcher
GW_CLIENT_ALREADY_DISC739 Connection partner has already disconnected the connection
GW_NO_HOST_IN_ROUTE 740 No hosts contained in route
..GW_ROUTE_CONNECT_DIS741 Route already disconnected (no longer used)
GW_CONN_IS_FREE742 Connection already released
GW_CONN_IS_DISC743 Connection disconnected
GW_REQBLK_ADM_ERROR 744 Error in request processing
GW_BUFINFO_ERROR745 Error in buffer handling
GW_HDLINFO_ERROR746 Error in network handling
TP_REG_NOREG_ERROR747 Number of registrations exceeded for this program
TP_REG_ACCESS_DENIED748 Access to registered server denied
GW_PARAM_NOT_FOUND749 Parameter could not be found
GW_PRXY_ACCESS_DENIED 750 Gateway must not be used as a proxy
GW_ACCEPT_TIMEOUT751 Timeout when logging on (gw/accept_timeout)
GW_WRONG_SERVER752 not connected to the gateway
C_NO_SIDE_INFO_GW760 No side info file
C_RECEIVE_WITH_PAR761 CMRCV failed
C_NO_SNC_LIB_ARG762 SNC library not in arg. list
C_NO_SNC_NAME_ARG763 SNC name not in argument list
C_SNC_INV_HANDLE764 SNC invalid handle
C_SNC_DISABLED765 SNC deactivated
C_SNC_ERROR766 General SNC error
C_SNC_MODE_ON767 SNC required
C_SNC_NOT_AVAILABLE 768 SNC not available
C_ILLEGAL_PARAMETER2769 Invalid parameter
C_AREA_TOO_SMALL770 Memory area too small
C_SNC_INV_STATE771 Invalid SNC status
C_RETURN_CODES772 Error numbers
C_REG_STATE_CHECK773 Status violation during registration
C_CPICTERR774 Error text for error number
C_NO_SYMDEST775 No symbolic destination
C_FUNCTION_NOT_SUPPORTED776 Function not supported
C_NET_CONV_ERROR777 Conversion error when reading or writing data
C_SIDEINFO_DISABLED778 Access to side info file deactivated
C_TIMEOUT_BLOCK779 Timeout for blocking network call
C_FAILOVER_ERROR780 Error when communicating with failover software
C_PROXY_ERROR781 Error when communicating with the proxy server
C_MPI_ERROR782 Error when communicating with memory pipes (Mpi)
C_MTX_ERROR783 Error with lock management (mutex)
C_CS_ERROR784 Error with lock management (critical section)

Validity
This document is not restricted to a software component or software component version

References
This document refers to:
SAP Notes
446172 SXPG_COMMAND_EXECUTE (program_start_error) in DB13
320991 Error codes during logon (list)
308929 Activating trace for SAP Logon Control
116051 Checklist: Problems SNA gateways (R/3 ==> R/2)
64016 Using the SAP Gateway monitor GWMON
63342 List: NI error codes
42692 Test tool for RFC links: sapinfo
34998 Checking on OS level whether R/3 is running

This document is referenced by:


SAP Notes (10)
557132 CC-TOPIC: Remote client copy
446172 SXPG_COMMAND_EXECUTE (program_start_error) in DB13
308929 Activating trace for SAP Logon Control
320991 Error codes during logon (list)
63342 List: NI error codes
64016 Using the SAP Gateway monitor GWMON
116051 Checklist: Problems SNA gateways (R/3 ==> R/2)
116787 CC-TOPIC: Remote client copy

34998 Checking on OS level whether R/3 is running


42692 Test tool for RFC links: sapinfo

S-ar putea să vă placă și