Sunteți pe pagina 1din 12

NL series

Pumps for industrial processes

CI-NL/A349-4 (Pte. Impresin)

(Standardized to ISO-2858/DIN-24256)

BOMBAS ITUR, S.A.


P.O. Box, 41
20800 ZARAUTZ (Gipuzkoa) SPAIN
Tel.: +34 943 899 899 Fax: +34 943 130 710
E.Mail: comexp@itur.es www.itur.es

DESCRIPTION

RANGE OF THE SERIES

The NL range of pumps are single-stage horizontal centrifugal


pumps, with axial suction and radial discharge, built to Standard
ISO-2858 (DIN-22858), evolved as a result to applying technological
innovation to the design and manufacture of the pumps for industrial
processes.

The NL Series covers a total of 41 models with closed impeller, based


of 34 pump sizes, where each different size allows for one or two types
of impeller (A or B).
Service limits
- Maximum flow: .......................................... 700 m3/h
- Maximum height differential ...................... 100 w.c.m.
- Maximum casing pressure (at 20 C)
* Executions 04 and 05: ............................ 16 Kg/cm2
* Executions 00, 01, 02 and 03: ................ 10 Kg/cm2
- Maximum suction pressure ....................... 5 Kg/cm2
- Maximum speed ........................................ 3.600 r.p.m.
- Maximum temperature .............................. 140 C
- Maximum viscosity .................................... 20 cSt (2,9 E)

These pumps are based on the sturdy design of NM series (medium


duty), and they are designed to work in processes with divers types of
liquids and with appropriate materials and mechanical seal. The characteristics of the NL Series are:
-

High hydraulic efficiency.


Sturdy design (24/24 hours).
Wide variety of materials available, according to the liquid being pumping.
Different sealing systems with standardized channels.
Different seal cooling plans.
Modular pumps (component versatility).
Standardized parts with high degree of interchangeability.
Minimal and rapid maintenance.

Although these pumps are normally driven by electric motor mounted on


a bed frame, other power drive sources may be used (diesel engine,
steam turbine, hydraulic motor, ...).

APPLICATIONS
The NL Series of ITUR Pumps has been specially conceived for the
pumping of a wide variety of liquids, generally without, or with slight
suspended matter, such as:
-

Clean liquids
Corrosive or abrasive liquids
High density liquids
Viscous liquids

Note.- With consultation, some of the limits laid down for the standard
construction can be exceeded.

Pump
size

Flanges
NL- DNd DNs
32/125 32
50

Assembly dimensions
a
f h1 h2 L5 x
80 385 112 140 60 3

32/160
32/200
40/125
40/160
50/125

32
32
40
40
50

50
50
65
65
80

80
80
80
100
100

40/200
50/160
50/200

40
50
50

65
80
80

100 385 160 180 60


100 385 160 180 60
100 385 160 200 60

After removing the spacer, the assembly made up of the support, cover
and impeller is removed, the pump casing and the motor always
remaining attached to the bed-plate. The suction and discharge pipes
remain connected.
In this way, maintenance is easier for these pumps that are working
during industrial processes.

385
385
385
385
385

132
160
112
132
132

160
180
140
160
160

60
60
60
60
60

3
3
3
3
3

210/3
197
225
177
197
197

197
225
177
197
197

Baseplate number 753


3
3

65/125

65

100 100 385 160 180 75

32
40

50
65

100 500 180 225 75


100 500 180 225 75

3
3

350

100 100 500 160 200 75


65
80
80
100
100
125
125
125

125
125
125
100
125
125
125
125

500
500
500
500
500
500
500
500

225
180
225
180
200
180
180
200

250
225
280
225
250
225
250
280

75
75
75
75
90
75
75
90

80

125 125 500 200 280 90


100
125
125
125
150

125
125
140
140
140

530
530
530
530
530

225
250
225
250
250

280
315
280
315
355

90
90
90
90
90

100/400 100
125/315 125
125/400 125

125 140 530 280 355 110


150 140 530 280 355 110
150 140 530 315 400 110

380

350/1

380

200 160 500 280 370 110


200 160 530 280 400 110

150/315 150
150/400 150

200 160 670 280 400 110


200 160 670 315 450 110

300/1

3
3
3
3
3
3
3
3

300/2

290
245 245
290
245 245 245
265
245
245 245
265 265

290
245
290
245
265
245
245
265

380/6

430/2

290
245
290
245
265
245
245
265

NL-100/250.B
NL Series
DN of discharge outlet, in mm
Nominal diameter of impeller, in mm
closed, design A
closed, design B

-2-

b2
300
360
390
440
440
470
470
520
520
520
620
620
670
670

430/3

3
3
3
3
3

300

430/2

290
245
290
245
265

245
325
245
300
280
245 280
265 300

280 280

300

325 350

245 245
300
280 280
280
300 300

300
300
300
300
300

325
325
325
325
325

380/6

430/2

430/4

350
350 (*)
350
350 (*)
350 (*)

530/1 530/2

430/2

325
350
325
350
350

430/3 430/4

530/2

430/2

3
3

(*)
(*)
(*)

] 120

(*)

(*)

] 160

325
350 350
325 350 (*)
350 350 350 350
350 350

(*)

] 120

380 380 380 380 380 380 (*)


380 380 380 380 380 380 380 (*)
415 415 415 415 415 (*)

530/1

(*)

] 120
325 350 (*)

530/1 530/2

325 325 325 325


350 350 350 350
325 325 325 325 325 325
350 350 350
350 350 350 350 350 350

3
3
3

530/2

580/2

(*)

(*)

] 160

(*)
(*)

] 120

(*)

(*)

] 160

380 380 380 380 380


380 380 380 380 380 380 380

580/3

3
3

Dimensions in mm
L1
L2
L3
760
510
125
770
520
125
880
580
150
750
500
125
850
600
125
1000
700
150
1150
750
200
1250
750
250
1000
700
150
1100
800
150
1240
740
250
1370
870
250
1360
860
250
1200
700
250

325

300 300 300 300 300 300 300 300

580/1
380 380 380 380 380 (*)
415 415 (*)

580/2

(*)
(*)

] 120

(*)
(*)

(*)

(*)

] 160

(*) Baseplate not standardized, with welded U beans. Please,


consult the specific plan.

PUMP DENOMINATION
b1
260
320
350
400
400
430
430
480
480
480
580
580
630
630

300

530/1

260 260 280

380/6

380

Baseplate number 75-

Baseplate
number
75-210/3
75-270/5
75-300/1
75-350
75-350/1
75-380
75-380/6
75-430/2
75-430/3
75-430/4
75-530/1
75-530/2
75-580/1
75-580/3

300

225

Baseplate number 75150/200 150


150/250 150

300

380/6 430/4

225 225 225 225 225

Baseplate number 75-

Type of impeller:

225 225 280


225 225 280
225 225 280

245 245 245 245


245
280 280
245 245 245 245 245 245 245 280 280 280

Baseplate number 75-

Process Industries
Chemical Industry
Paint booths
Vehicle Industry
Food Industry
Paper Industry
Water supply
Irrigation

225
225

380

Baseplate number 7565/315 65


80/315 80
100/250 100
100/315 100
125/250 125

225
225

300/1 380

350/1

Baseplate number 7580/250

197
225
197
197
197

300/1

350

Baseplate number 7540/315 40


50/250 50
50/315 50
65/200 65
65/250 65
80/160 80
80/200 80
100/200 100

197
225
177
197
197

225 225 225 225 225 225

Baseplate number 7565

197
225
177
197
197

270/5

Baseplate number 7532/250


40/250

270/5 300/1
197
225
177
197
197

225 225 225 225 225 225


225 225 225 225 225 225
225 225 225 225 225 225

Baseplate number 75-

65/160
The standard version of the electro-pump unit embodies the normal
semi-flexible coupling. Upon request, this coupling can be supplied with
a spacer. The use of the semi-flexible coupling with spacer allows easy
access to the pump interior without the need to remove the pipes or the
motor.

Dimensions in mm
Head -h 3- and the standardized baseplate type, in terms of motor size (I.E.C.)
80M 90S 90L 100L 112M 132S 132M 160M 160L 180M 180L 200L 225S 225M 250M 280S 280M 315S 315M
177 177 177 177 177 177

Baseplate number 75-

EASE OF MAINTENANCE

These pumps are designed for pumping systems of industrial processes, where a sturdy larger margin and the reliability of the operating
are necessary. As a result, this Series is ideal in:









ELECTROPUMP DIMENSIONS STANDARDIZED TO ITUR

L4
-

S
18
18
18
18
18
18
18
18
18
18
18
18
18
18

T
6
6
6
6
6
6
30
30
30
30
30
30
30
30

- 11 -

BASEPLATE DIMENSIONS
STANDARDIZED TO ITUR

CONSTRUCTION
Pump casing
With volute casing and support feet, it incorporates a wear ring.
The casing to cover sealing is effected by means of an embedded gasket.
Suction and discharge flanges
Integrally cast with the casing, constructed of GG-25 to DIN2533, and of steel to DIN-2543, crackle-finished "RF" to DIN2526 form C. Valid for connecting to commercial flanges DIN
PN-16. Optionally the casing can be supplied with other types of
flanges (ANSI, BS, DIN-2512, etc.).
Auxiliary connections
The standard version carries vent, drain, seal circulation,
pressure and vacuum gauge connections. All of these drilled
and closed off with the corresponding covers.
Pump cover
Casting in one piece, and independent of the seal design, it
incorporates several extractors in order to facilitate its removal.
Wear rings
All models incorporate a wear ring in the casing, in order to
facilitate repairs and make them cheaper.
Impeller
Closed impeller, cast in one piece, hydraulically and dynamically balanced, with dorsal fins in order to balance out the axial
thrust and to avoid the sedimentation of some suspended matter
which are carried together with the liquid. It is keyed to the shaft
and locked by means of a double nut.
Pump shaft
Well dimensioned, the shaft is especially resistant to bending. It
is provided with a replaceable shaft sleeve, sealed with the
shaft itself by means of a toroidal seal. Thus, changing the shaft
can be avoided, in the case of wear or abrasion in the sealing
area, achieving rapid, cheap maintenance. Included is a deflector next to the support in order to protect the ingress of liquid.

MOTOR SIZE AND POWER AT 50 Hz, IP-55, STANDARDIZED TO I.E.C.


Motor power in kW
Motor power in HP
M. size at 1.450 rpm
M. size at 2.900 rpm

0,55 0,75 1,1 1,5 2,2


3
4
5,5 7,5
0,75 1
1,5
2
3
4
5,5 7,5 10
80M 80M 90S 90L 100L 100L 112M 132S 132M
71M 80M 80M 90S 90L 100L 112M 112M 132S

11
15
160M
160M

15
20
160L
160M

18,5
25
180M
160L

22
30
180L
180M

30 37 45
40 50 60
200L 225S 225M
200L 200L 225M

NOTE.- ITUR Pumps practices a policy of continual development of its models. For this reason specifications are subject to change without notice.

- 10 -

55
75
250M
250M

75
100
280S
280S

90
125
280M
280M

110
150
315S
315S

132
180
315M
315M

160
220
315M
315M

Bearing support
Of modern design, it incorporates two total double seal ball
bearings, with grease for its entire lifespan and as such its
maintenance is not required during normal operation. The
bearing protection against external agents (water, dust, ...) is
effected by means of the lip seal.
-3-

Standard sealing systems


A wide variety of sealing systems can be incorporated, according
to the type of liquid to be pumped. The NL Series of ITUR Pumps
has for the standard version, provision for the following possibilities:
 Packing
Asbestos-free, provided with the corresponding lantern.
Cooling Plan API-11.
 Simple mechanical DIN seal
Standardized to DIN-24960, on the long version with locking
pin and choke ring. The material used in the contacting faces
depends upon the liquid to be pumped.
Cooling Plan API-11/61.
 Simple DIN balanced mechanical seal
Standardized to DIN-24960, on the long version with locking
pin and choke ring. Balancing is used when the pressure
generated in the pump requires it. The material used in the
contacting faces depends upon the liquid to be pumped.
Cooling Plan API-11/61.
 DIN double mechanical seal ("back to back")
Standardized to DIN-24960, on the short version with locking pin
only on the process side, and choke ring. The material used in the
contacting faces depends upon the liquid to be pumped.
Cooling Plan API-54.

Optional sealing systems


The NL Series allows for the inclusion, on request, of the other
types of shaft sealing:
 External mechanical seal
Of type 10 T without protective screen or safety ring.
 Mechanical seal, not to DIN
Seals with conform to special standards or which are of
special sizes.

Baseplate and coupling


The driving of the pump by the motor is effected via a semiflexible coupling. The assembly is mounted on a baseplate
standardized to ITUR. Optionally the coupling can be supplied
with a spacer, which allows easy access to the pump interior
without the need to remove the pipes or the motor. In this case,
the baseplate is constructed according to ISO-3661.

STANDARDIZED MATERIALS

FREE SHAFT PUMP DIMENSIONS

The NL Series of ITUR Pumps has been studied in 6 different versions of the highest quality standardized materials, in order to provide an extensive,
fast, sure service, seeking standardized solutions for the entire range of pumps for industrial processes.
Other materials are possible, on request.

Ref.

Componente

102 Pump casing


161 Pump cover
210 Pump shaft
230 Impeller
330 Bearing support
452 Stuffing box (P)
471 Seal cover (S)
502 Wear ring
523 Shaft sleeve (S)
524 Shaft sleeve (P)

(*)
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN

4300
GG-25
GG-25
0.6025
GG-25
0.6025
F-114
1.1191
GG-25
0.6025
GG-25
0.6025
GG-25
0.6025
GG-25
0.6025
GG-25
0.6025
AISI-316
1.4401
AISI-431B
1.4057

4301
MIXTA
GG-25
0.6025
GG-25
0.6025
AISI-316
1.4401
G Sn Bz 10
2.1050.01
GG-25
0.6025
RG-5
2.1096.01
GG-25
0.6025
RG-5
2.1096.01
AISI-316
1.4401
AISI-431B
1.4057

STANDARDIZED VERSION
4302
4303
4304
MISTINOX
BRONCE
NODULAR
GG-25
RG-5
GGG-40
0.6025
2.1096.01
0.7040
GG-25
RG-5
GGG-40
0.6025
2.1096.01
0.7040
AISI-316
AISI-316
F-114
1.4401
1.4401
1.1191
CF8M
G Sn Bz 10 GG-25
1.4408
2.1050.01
0.6025
GG-25
GG-25
GG-25
0.6025
0.6025
0.6025
GG-25
RG-5
GG-25
0.6025
2.1096.01
0.6025
GG-25
AISI-316 AISI-316
0.6025
1.4408
1.4408
CF-8M
RG-5
GG-25
1.4408
2.1096.01
0.6025
AISI-316
AISI-316 AISI-316
1.4401
1.4401
1.4401
AISI-431B
AISI-431B AISI-431B
1.4057
1.4057
1.4057

4305
AISI-316
AISI-316
1.4408
AISI-316
1.4408
AISI-316
1.4401
AISI-316
1.4408
GG-25
0.6025
AISI-316
1.4408
AISI-316
1.4408
AISI-316
1.4408
AISI-316
1.4401
AISI-316
1.4401

4323
IMPINOX
GGG-40
0.7040
GGG-40
0.7040
F-114
1.1191
CF8M
1.4408
GG-25
0.6025
GG-25
0.6025
CF8M
1.4408
GG-25
0.6025
AISI-316
1.4401
AISI-431B
1.4057

(P) = Version with packing


(S) = Version with mechanical seal
( * ) = Material Denomination / Equivalent Werkstoff Number DIN-17007.

Pump
size

NL-

RECOMMENDED REPLACEMENT PARTS


Spares recommended for
2 years operation
1
1
1
1
2
1
2

Running
1
-

5 years operation
2
1
1
2
2
2
5
2
4

461
458
524

1
1
-

4
2
1

10
3
3

Simple mechanical seal


Shaft sleeve
Pin
Set of setscrews

433
523
560
904

1
1
1

1
1
1
1

2
1
2
2

Cierre DIN
equilibrado

Packing set
Packing lantern
Shaft sleeve

Balanced mechanical seal


Shaft sleeve
Pin

Cierre DIN
doble

Versin
empaquetadura

Wear ring
Pump shaft
Impeller
Protective deflector
Impeller nut
Set of bearings
Set of seals
Set of shaft keys
Set of sealing rings

Ref.
number
502
210
230
507
922
321.1 and 2
Set
940.1 and 2
425.1 and 2

Cierre DIN
simple

Piezas comunes

Title
of part

Double mechanical seal


Shaft sleeve
Pin
Set of setscrews

433.1
523
560
433.2 and 3
523
560
904

1
1

1
1
1

1
1
1

1
1
1
1

2
1
2
2
1
2
2

32/125
32/125
32/160
32/160
32/200
32/200
32/250
32/250
40/125
40/125
40/160
40/160
40/200
40/200
40/250
40/250
40/315
40/315
50/125
50/125
50/160
50/160
50/200
50/200
50/250
50/250
50/315
50/315
65/125
65/125
65/160
65/160
65/200
65/200
65/250
65/250
65/315
65/315
80/160
80/160
80/200
80/200
80/250
80/250
80/315
80/315
100/200
100/250
100/315
100/400
125/250
125/315
124/400
** 150/200
**
150/250
150/315
150/400

Flanges
DNd DNs
32

40

50

65

80

100

125

150

50

65

80

100

125

125

150

200

Pump dimensions
a
f
h1
h2
b
112 140
80 385 132 160
50
160 180
100 500 180 225
65
80
112 140
100* 385 132 160
50
160 180
100
180 225
500
65
225* 250
125
132 160
100 385
180
50
160
200
180 225
125 500
65
225 280
385
180
160
100
200
65
500 180 225
200 250
125
80
530 225 280
225
180
65
500
250
125
200* 280
80
530 250 315
125 500 200
280
225
80
140 530 250 315
280 355 100
250
80
355
140 530 280
100
315 400
500
370
280
530
400
160
100
280* 400*
670
315 450

m1
100

Dimensions in mm
Foot dimensions
m2
n1
n2
n3
190 140
70
240 190 110

125

95

100

70

125

95

100

70

125

95

125

95

160

120

125

95

160

120

320
210
240
265
320
345
240

250
160
190
212
250
280
190

265

212

320
345

250
280

280

212

320
360

250
280

400
320
345

315
250
280

400

315

360

280

400

315

160

120

200
160

150
120

500
400

400
315

200

150

500

400

200

150

450

s2

14

14

w
285

100

370
285
110

14

14

285
110

14

14

285
14

100

14
370

18

140

14
110

14

370

140

18

110

18

-9-

24

50

26,9

32

80

35,3

10

24

50

26,9

32

80

35,3

10

24

50

26,9

32

80

35,3

10

24

50

26,9

32

80

35,3

10

42

95* 45,1

12

32

80

35,3

10

42
32

95* 45,1
80 35,3

12
10

14

370

140

42

95* 45,1

12

14

370

140

42

95* 45,1

12

14
14

370

32
42

80 35,2
95* 45,1

10
12

14*

500

48

110

14

23
18
110

110*

23

23

180

* Dimensions out of the ISO-2858 standard. ** Adition to the standard.


NOTE.- ITUR Pumps practices a policy of continual development of its models. For this reason specifications are subject to change without notice.

-4-

100
370

110

Shaft end
l
t

100
370

550 450
110
550* 450*
550

s1

Sup.
y

51,5

Weight
in
Kg
35
40
49
77
36
45
50
80
95
43
49
58
85
104
49
65
75
90
116
79
95
107
125
100
120
140
210
136
209
230
176
209
220
240

PUMP EXPLODED VIEW


Ref.
102
161
183
210
230
321.1
321.2
330
344
360
400
425.1
425.2

Component title
Pump casing
Pump cover
Supporting foot
Pump shaft
Impeller
Front bearing
Rear bearing
Bearing support
Adapter
Bearing cover
Flat gasket
Front lip seal
Rear lip seal

PARTS INTERCHANGEABILITY
Ref.
433
433.1
433.2
433.3
452
456
457
458
461
471
471.1
471.2
484

Component title
Simple mechanical seal
Balanced mechanical seal
Double mech. seal, atmospheric side
Double mech. seal, process side
Stuffing box
End stop
End ring
Packing lantern
Packing
Simple mechanical seal cover
Balanced mechanical seal cover
Double mechanical seal cover
Fixing sleeve

Ref.
502
507
523
524
525
903.1
903.2
903.3
903.4
904
922
940.1
940.2

Component title
Wear ring
Protective deflector
Shaft sleeve (mechanical seal)
Shaft sleeve (packing)
Spacer sleeve
Vacuum meter cover
Pressure gauge cover
Pump emptying plug
Sump emptying plug
Pin
Impeller nut
Impeller key
Driving key

The Standardization of parts and materials involves an important advance


in the modularization of the pump and the versatility of its components.
For this reason, in the NL Series it has been possible to attain a high
number of parts, common and interchangeable, between the different
models of pumps.
The component parts listed in the upper part of the Table are standard
and interchangeable between the different sizes of pumps appearing in
the left-hand column provided that the same letter and colour are shown
in the corresponding box.
The advantage of this standardization rests on the fact that a minimum
stock of parts ensures the efficient maintenance of many different
models of pumps.

EXAMPLE
The pump shaft of model NL-32/200.A is identical and interchangeable,
at the same material, with that of models:
 NL-32/200.B
 NL-40/160.A
 NL-40/160.B
 NL-40/200.B
 NL-50/125.B
 NL-50/160.B
 NL-50/200.A
 NL-50/200.B
 NL-65/125.B
Since in the column "Pump shaft" the letter B appears in all of them.

Pump with simple


mechanical seal

TYPE
OF
PUMP

NL32/125.A
32/125.B
32/160.B
40/125.B
32/200.A
32/200.B
40/160.A
40/160.B
40/200.B
50/125.B
50/160.B
50/200.A
50/200.B
65/125.B
32/250.B
40/250.A
40/250.B
65/160.B
80/160.A
80/160.B
40/315.B
50/315.B
65/250.B
80/200.B
80/250.B
100/200.A
150/200.B
50/250.B
65/200.B
65/315.B
80/315.B
100/250.B
100/315.B
125/250.A
125/250.B
150/250.B
100/400.B
125/315.B
125/400.B
150/315.B
150/400.B

Bearing
support
330
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
C
C
C
C
C
C
C
C
C
C
D
D

Ball
bearing
321
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
C
C
C
C
C
C
C
C
C
C
D
D

Protective
deflector
507
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
C
C
C
C
C
C
C
C
C
C
D
D

Pump
shaft
210
A
A
A
A
B
B
B
B
B
B
B
B
B
B
C
C
C
C
C
C
D
D
D
D
D
D
D
E
E
F
F
F
F
F
F
F
G
G
G
H
H

Title of part and reference number in the pump exploded view


Impeller
Impeller
Shaft
Packing version
Simple mech. seal version
Double mech. seal version
nut
key
sleeve (1) Packing Stuffing box Lantern Simple seal Seal cover Double seal Seal cover
922
940.1
523 y 524
461
452
458
433
471
433.2 y 3 471.2 y 3
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
C
C
C
B
B
B
B
C
B
B
C
C
C
B
B
B
B
C
B
B
C
C
C
B
B
B
B
C
B
B
C
C
C
B
B
B
B
C
B
B
C
C
C
B
B
B
B
C
B
B
C
C
C
B
B
B
B
C
B
C
D
D
D
C
C
C
C
D
C
C
D
D
D
C
C
C
C
D
C
C
D
D
D
C
C
C
C
D
C
C
D
D
D
C
C
C
C
D
C
C
D
D
D
C
C
C
C
D
C
C
D
D
D
C
C
C
C
D
C
C
D
D
D
C
C
C
C
D
C
B
E
E
C
C
C
C
C
D
C
B
E
E
D
C
C
C
C
D
C
C
F
D
D
C
C
C
C
D
C
C
F
D
D
C
C
C
C
D
C
C
F
D
D
C
C
C
C
D
C
C
F
D
D
C
C
C
C
D
C
C
F
D
D
C
C
C
C
D
C
C
F
D
D
C
C
C
C
D
C
C
F
D
D
C
C
C
C
D
C
D
G
F
E
D
D
D
D
E
D
D
G
F
E
D
D
D
D
E
D
D
G
F
E
D
D
D
D
E
D
E
H
G
F
E
E
E
E
F
E
E
H
G
F
E
E
E
E
F
E

(1) Only for packing, simple mechanical seal and balanced mechanical seal versions.
Detail of packing

Detail of balanced mechanical seal

-8-

Detail of double mechanical seal

NOTE.- ITUR Pumps practices a policy of continual development of its models. For this reason specifications are subject to change without notice.

-5-

Pump
cover
161
1
1
2
5
3
3
6
6
3
9
10
11
11
9
4
7
7
13
13
17
8
8
15
18
19
18
25
12
14
16
20
19
21
19
19
19
22
23
24
26
27

TECHNICAL DATA

PUMP SELECTION DIAGRAMS

The following Table shows the main Technical Data for the NL Series
of pumps, in terms of their construction of materials and standard parts,
and pimping clean water at 20 C, with a specific weight of 1 Kg/dm3.

These diagrams make possible a rapid selection of the most suitable type of pump. There are occasions in which, once a pump has been selected,
it will also be possible to find another which may satisfy the task conditions with greater efficiency or less NPSH required. In such cases, the final
selection will be made, based on the particular curves for each pump.

The values shown corresponding exclusively to the pump, without taking


into account the loads added by the motor, coupling, baseplate or piping.
If you have need of more Data, please consult the Engineering Department of ITUR Pumps.

150

100/400.B

/40

0.B

125/400.B

100

40/315.B

65/315.B
50/315.B

/31

5.B
125/315.B

80/315.B

40/250.B

6309 *

6309 *

6306 *

6306 *

6309 *

6309 *

6311 *

6311 *

6309 *

6309 *

6311 *
6309 *

6311 *
6309 *

6311 *

6311 *

6309 *
6311 *

6309 *
6311 *

6313 *

6313 *

1/4

3/8

1/4

50/160.B

/16

.A

150/250.B

125/250.A

150/200.B

80/160.B

65
32/125.B

/12

5.B

50/125.B
32/125.A

80/200.B

0.B

40/160.A

80/160.A

40/125.B

Range coverage.
See INP Catalogues.

40/250.B

32/250.B

40/250.A

50/250.B

32 /2 00 .B

32/200.A

40/200.B
50/200.A

32/160.B

65/250.B

80/250.B
100/250.B

50 /2 00 .B

40/160.B

65/200.B

80/200.B

50/160.B
65/160.B 80/160.B

40/160.A
32/125.B
40/125.B
32/125.A

NOTE.- ITUR Pumps practices a policy of continual development of its models. For this reason specifications are subject to change without notice.

-6-

0.B

0/2

65

40/160.B
32/160.B

/20

00

00.A

125/250.B
100/250.B

10

mm
mm
143
113
143
113
177
138
150
180
212
180
266
216
143
113
177
137
177
137
212
175
266
226
266
216
328
280
143
113
177
137
218
178
218
178
247
207
328
280
143
113
177
140
218
178
266
226
328
281
170
130
177 160/132
214
184
271
220
336
276
209
170
266
226
336
276
412
336
245
195
271
221
329
276
418
338
214 212/165
266
216
336
261
418
350

Minimum
diameter

mm
11,5
17,5
13,5
13,0
15,0
17,0
22,5
17,0
20,5
17,5
16,5
19,5
18,5
30,0
25,5
18,0
20,5
24,0
18,5
37,0
30,0
28,0
25,5
23,5
35,0
41,5
35,0
31,0
29,0
37,0
40,0
35,5
31,5
50,0
48,5
43,5
38,5
76,5
50,5
55,0
48,0

50/2

65

-7-

.A

6306 *

mm
1
8
4
2
4
3
12
5
10
7
3
6
5
12
10
5
9
10
5
12
10
14
12
9
10
15
10
14
15
14
15
19
10
24
20
25
20
30
26
25
20

40/200.B

32/200.A

00.B

80/250.B

00

6306 *

1/4

mm
3,0
10,0
6,0
4,0
6,0
5,0
15,0
7,0
12,0
9,0
4,5
8,0
7,0
22,0
17,0
7,0
12,0
13,0
7,0
27,0
21,0
17,0
15,0
12,0
27,0
33,0
25,0
20,0
17,5
29,0
28,0
23,5
17,0
38,0
37,0
30,5
24,0
61,5
40,0
43,0
33,5

50/2

32/200.B

50.B

0/2

6309 *

cm2
12,1
22,4
22,1
14,4
22,1
28,3
39,6
25,2
37,3
37,3
25,2
37,3
38,6
56,5
60,8
36,4
48,7
55,5
38,6
71,4
87,9
78,5
84,7
77,0
88,0
128,1
148,5
146,2
122,7
128,5
219,0
151,7
160,6
216,4
219,0
208,6
229,7
283,5
251,6
301,7
301,7

40/250.A

150/315.B

65/2

50/250.B

10

6309 *

"Gas

Maximum
diameter

6306 *

"Gas

Total
width

6306 *

"Gas

Maximum
solids passage

32/125.A
32/125.B
30 30/35
8
5
32/160.B
32/200.A
4
32/200.B
40 40/45 10
32/250.B
6
40/125.B
30 30/35
8
5
40/160.A
40/160.B
4
40/200.B
40 40/45
40/250.A
40/250.B
6
40/315.B
50 50/55
50/125.B
50/160.B
40 40/45
4
50/200.A
50/200.B
50/250.B
50 50/55
6
50/315.B
65/125.B
4
40 40/45
65/160.B
65/200.B
65/250.B
50 50/55
65/315.B
10
80/160.A
40 40/45
80/160.B
80/200.B
80/250.B
80/315.B
50 50/55
100/200.A
100/250.B
6
100/315.B
100/400.B 60 60/65
125/250.A
50 50/55
125/250.B
125/315.B
60 60/65
125/400.B
150/200.B
50 50/55
150/250.B
150/315.B
60 60/65
150/400.B
(*) All of bearings have type 2RS1 C3.

Kg.m2 "Gas
0,016
0,016
0,036
0,072
0,080
0,208
0,200
0,048
0,048 1/4
0,084
0,224
0,192
0,528
0,028
0,052
0,108
0,096
0,184
0,472 1/2
0,028
0,056 1/4
0,112
0,248
0,520
0,073
0,072
0,152
0,308
0,624
0,146
0,356
0,732 1/2
1,588
0,272
0,388
0,852
1,780
0,220
0,328
0,956
1,908

Effective
outlet passage

32/250.B

Eye
Area

Seal
cooling

u.

Pressure/vacuum
gauges

Thrust

mm

Impeller data

Drain
connection

Radial

mm

Connections

Vent
connection

Number
of rings

mm

GD2

Moment
of Inertia

Grillage
size

NL-

Type of bearings

Simple
balanced

PUMP
TYPE

Packing

Simple or
double

Mech. seal

50/125.B

65/125.B

80/160.A

TECHNICAL DATA

PUMP SELECTION DIAGRAMS

The following Table shows the main Technical Data for the NL Series
of pumps, in terms of their construction of materials and standard parts,
and pimping clean water at 20 C, with a specific weight of 1 Kg/dm3.

These diagrams make possible a rapid selection of the most suitable type of pump. There are occasions in which, once a pump has been selected,
it will also be possible to find another which may satisfy the task conditions with greater efficiency or less NPSH required. In such cases, the final
selection will be made, based on the particular curves for each pump.

The values shown corresponding exclusively to the pump, without taking


into account the loads added by the motor, coupling, baseplate or piping.
If you have need of more Data, please consult the Engineering Department of ITUR Pumps.

150

100/400.B

/40

0.B

125/400.B

100

40/315.B

65/315.B
50/315.B

/31

5.B
125/315.B

80/315.B

40/250.B

6309 *

6309 *

6306 *

6306 *

6309 *

6309 *

6311 *

6311 *

6309 *

6309 *

6311 *
6309 *

6311 *
6309 *

6311 *

6311 *

6309 *
6311 *

6309 *
6311 *

6313 *

6313 *

1/4

3/8

1/4

50/160.B

/16

.A

150/250.B

125/250.A

150/200.B

80/160.B

65
32/125.B

/12

5.B

50/125.B
32/125.A

80/200.B

0.B

40/160.A

80/160.A

40/125.B

Range coverage.
See INP Catalogues.

40/250.B

32/250.B

40/250.A

50/250.B

32 /2 00 .B

32/200.A

40/200.B
50/200.A

32/160.B

65/250.B

80/250.B
100/250.B

50 /2 00 .B

40/160.B

65/200.B

80/200.B

50/160.B
65/160.B 80/160.B

40/160.A
32/125.B
40/125.B
32/125.A

NOTE.- ITUR Pumps practices a policy of continual development of its models. For this reason specifications are subject to change without notice.

-6-

0.B

0/2

65

40/160.B
32/160.B

/20

00

00.A

125/250.B
100/250.B

10

mm
mm
143
113
143
113
177
138
150
180
212
180
266
216
143
113
177
137
177
137
212
175
266
226
266
216
328
280
143
113
177
137
218
178
218
178
247
207
328
280
143
113
177
140
218
178
266
226
328
281
170
130
177 160/132
214
184
271
220
336
276
209
170
266
226
336
276
412
336
245
195
271
221
329
276
418
338
214 212/165
266
216
336
261
418
350

Minimum
diameter

mm
11,5
17,5
13,5
13,0
15,0
17,0
22,5
17,0
20,5
17,5
16,5
19,5
18,5
30,0
25,5
18,0
20,5
24,0
18,5
37,0
30,0
28,0
25,5
23,5
35,0
41,5
35,0
31,0
29,0
37,0
40,0
35,5
31,5
50,0
48,5
43,5
38,5
76,5
50,5
55,0
48,0

50/2

65

-7-

.A

6306 *

mm
1
8
4
2
4
3
12
5
10
7
3
6
5
12
10
5
9
10
5
12
10
14
12
9
10
15
10
14
15
14
15
19
10
24
20
25
20
30
26
25
20

40/200.B

32/200.A

00.B

80/250.B

00

6306 *

1/4

mm
3,0
10,0
6,0
4,0
6,0
5,0
15,0
7,0
12,0
9,0
4,5
8,0
7,0
22,0
17,0
7,0
12,0
13,0
7,0
27,0
21,0
17,0
15,0
12,0
27,0
33,0
25,0
20,0
17,5
29,0
28,0
23,5
17,0
38,0
37,0
30,5
24,0
61,5
40,0
43,0
33,5

50/2

32/200.B

50.B

0/2

6309 *

cm2
12,1
22,4
22,1
14,4
22,1
28,3
39,6
25,2
37,3
37,3
25,2
37,3
38,6
56,5
60,8
36,4
48,7
55,5
38,6
71,4
87,9
78,5
84,7
77,0
88,0
128,1
148,5
146,2
122,7
128,5
219,0
151,7
160,6
216,4
219,0
208,6
229,7
283,5
251,6
301,7
301,7

40/250.A

150/315.B

65/2

50/250.B

10

6309 *

"Gas

Maximum
diameter

6306 *

"Gas

Total
width

6306 *

"Gas

Maximum
solids passage

32/125.A
32/125.B
30 30/35
8
5
32/160.B
32/200.A
4
32/200.B
40 40/45 10
32/250.B
6
40/125.B
30 30/35
8
5
40/160.A
40/160.B
4
40/200.B
40 40/45
40/250.A
40/250.B
6
40/315.B
50 50/55
50/125.B
50/160.B
40 40/45
4
50/200.A
50/200.B
50/250.B
50 50/55
6
50/315.B
65/125.B
4
40 40/45
65/160.B
65/200.B
65/250.B
50 50/55
65/315.B
10
80/160.A
40 40/45
80/160.B
80/200.B
80/250.B
80/315.B
50 50/55
100/200.A
100/250.B
6
100/315.B
100/400.B 60 60/65
125/250.A
50 50/55
125/250.B
125/315.B
60 60/65
125/400.B
150/200.B
50 50/55
150/250.B
150/315.B
60 60/65
150/400.B
(*) All of bearings have type 2RS1 C3.

Kg.m2 "Gas
0,016
0,016
0,036
0,072
0,080
0,208
0,200
0,048
0,048 1/4
0,084
0,224
0,192
0,528
0,028
0,052
0,108
0,096
0,184
0,472 1/2
0,028
0,056 1/4
0,112
0,248
0,520
0,073
0,072
0,152
0,308
0,624
0,146
0,356
0,732 1/2
1,588
0,272
0,388
0,852
1,780
0,220
0,328
0,956
1,908

Effective
outlet passage

32/250.B

Eye
Area

Seal
cooling

u.

Pressure/vacuum
gauges

Thrust

mm

Impeller data

Drain
connection

Radial

mm

Connections

Vent
connection

Number
of rings

mm

GD2

Moment
of Inertia

Grillage
size

NL-

Type of bearings

Simple
balanced

PUMP
TYPE

Packing

Simple or
double

Mech. seal

50/125.B

65/125.B

80/160.A

PUMP EXPLODED VIEW


Ref.
102
161
183
210
230
321.1
321.2
330
344
360
400
425.1
425.2

Component title
Pump casing
Pump cover
Supporting foot
Pump shaft
Impeller
Front bearing
Rear bearing
Bearing support
Adapter
Bearing cover
Flat gasket
Front lip seal
Rear lip seal

PARTS INTERCHANGEABILITY
Ref.
433
433.1
433.2
433.3
452
456
457
458
461
471
471.1
471.2
484

Component title
Simple mechanical seal
Balanced mechanical seal
Double mech. seal, atmospheric side
Double mech. seal, process side
Stuffing box
End stop
End ring
Packing lantern
Packing
Simple mechanical seal cover
Balanced mechanical seal cover
Double mechanical seal cover
Fixing sleeve

Ref.
502
507
523
524
525
903.1
903.2
903.3
903.4
904
922
940.1
940.2

Component title
Wear ring
Protective deflector
Shaft sleeve (mechanical seal)
Shaft sleeve (packing)
Spacer sleeve
Vacuum meter cover
Pressure gauge cover
Pump emptying plug
Sump emptying plug
Pin
Impeller nut
Impeller key
Driving key

The Standardization of parts and materials involves an important advance


in the modularization of the pump and the versatility of its components.
For this reason, in the NL Series it has been possible to attain a high
number of parts, common and interchangeable, between the different
models of pumps.
The component parts listed in the upper part of the Table are standard
and interchangeable between the different sizes of pumps appearing in
the left-hand column provided that the same letter and colour are shown
in the corresponding box.
The advantage of this standardization rests on the fact that a minimum
stock of parts ensures the efficient maintenance of many different
models of pumps.

EXAMPLE
The pump shaft of model NL-32/200.A is identical and interchangeable,
at the same material, with that of models:
 NL-32/200.B
 NL-40/160.A
 NL-40/160.B
 NL-40/200.B
 NL-50/125.B
 NL-50/160.B
 NL-50/200.A
 NL-50/200.B
 NL-65/125.B
Since in the column "Pump shaft" the letter B appears in all of them.

Pump with simple


mechanical seal

TYPE
OF
PUMP

NL32/125.A
32/125.B
32/160.B
40/125.B
32/200.A
32/200.B
40/160.A
40/160.B
40/200.B
50/125.B
50/160.B
50/200.A
50/200.B
65/125.B
32/250.B
40/250.A
40/250.B
65/160.B
80/160.A
80/160.B
40/315.B
50/315.B
65/250.B
80/200.B
80/250.B
100/200.A
150/200.B
50/250.B
65/200.B
65/315.B
80/315.B
100/250.B
100/315.B
125/250.A
125/250.B
150/250.B
100/400.B
125/315.B
125/400.B
150/315.B
150/400.B

Bearing
support
330
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
C
C
C
C
C
C
C
C
C
C
D
D

Ball
bearing
321
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
C
C
C
C
C
C
C
C
C
C
D
D

Protective
deflector
507
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
C
C
C
C
C
C
C
C
C
C
D
D

Pump
shaft
210
A
A
A
A
B
B
B
B
B
B
B
B
B
B
C
C
C
C
C
C
D
D
D
D
D
D
D
E
E
F
F
F
F
F
F
F
G
G
G
H
H

Title of part and reference number in the pump exploded view


Impeller
Impeller
Shaft
Packing version
Simple mech. seal version
Double mech. seal version
nut
key
sleeve (1) Packing Stuffing box Lantern Simple seal Seal cover Double seal Seal cover
922
940.1
523 y 524
461
452
458
433
471
433.2 y 3 471.2 y 3
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
C
C
C
B
B
B
B
C
B
B
C
C
C
B
B
B
B
C
B
B
C
C
C
B
B
B
B
C
B
B
C
C
C
B
B
B
B
C
B
B
C
C
C
B
B
B
B
C
B
B
C
C
C
B
B
B
B
C
B
C
D
D
D
C
C
C
C
D
C
C
D
D
D
C
C
C
C
D
C
C
D
D
D
C
C
C
C
D
C
C
D
D
D
C
C
C
C
D
C
C
D
D
D
C
C
C
C
D
C
C
D
D
D
C
C
C
C
D
C
C
D
D
D
C
C
C
C
D
C
B
E
E
C
C
C
C
C
D
C
B
E
E
D
C
C
C
C
D
C
C
F
D
D
C
C
C
C
D
C
C
F
D
D
C
C
C
C
D
C
C
F
D
D
C
C
C
C
D
C
C
F
D
D
C
C
C
C
D
C
C
F
D
D
C
C
C
C
D
C
C
F
D
D
C
C
C
C
D
C
C
F
D
D
C
C
C
C
D
C
D
G
F
E
D
D
D
D
E
D
D
G
F
E
D
D
D
D
E
D
D
G
F
E
D
D
D
D
E
D
E
H
G
F
E
E
E
E
F
E
E
H
G
F
E
E
E
E
F
E

(1) Only for packing, simple mechanical seal and balanced mechanical seal versions.
Detail of packing

Detail of balanced mechanical seal

-8-

Detail of double mechanical seal

NOTE.- ITUR Pumps practices a policy of continual development of its models. For this reason specifications are subject to change without notice.

-5-

Pump
cover
161
1
1
2
5
3
3
6
6
3
9
10
11
11
9
4
7
7
13
13
17
8
8
15
18
19
18
25
12
14
16
20
19
21
19
19
19
22
23
24
26
27

STANDARDIZED MATERIALS

FREE SHAFT PUMP DIMENSIONS

The NL Series of ITUR Pumps has been studied in 6 different versions of the highest quality standardized materials, in order to provide an extensive,
fast, sure service, seeking standardized solutions for the entire range of pumps for industrial processes.
Other materials are possible, on request.

Ref.

Componente

102 Pump casing


161 Pump cover
210 Pump shaft
230 Impeller
330 Bearing support
452 Stuffing box (P)
471 Seal cover (S)
502 Wear ring
523 Shaft sleeve (S)
524 Shaft sleeve (P)

(*)
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN
Material
N W. DIN

4300
GG-25
GG-25
0.6025
GG-25
0.6025
F-114
1.1191
GG-25
0.6025
GG-25
0.6025
GG-25
0.6025
GG-25
0.6025
GG-25
0.6025
AISI-316
1.4401
AISI-431B
1.4057

4301
MIXTA
GG-25
0.6025
GG-25
0.6025
AISI-316
1.4401
G Sn Bz 10
2.1050.01
GG-25
0.6025
RG-5
2.1096.01
GG-25
0.6025
RG-5
2.1096.01
AISI-316
1.4401
AISI-431B
1.4057

STANDARDIZED VERSION
4302
4303
4304
MISTINOX
BRONCE
NODULAR
GG-25
RG-5
GGG-40
0.6025
2.1096.01
0.7040
GG-25
RG-5
GGG-40
0.6025
2.1096.01
0.7040
AISI-316
AISI-316
F-114
1.4401
1.4401
1.1191
CF8M
G Sn Bz 10 GG-25
1.4408
2.1050.01
0.6025
GG-25
GG-25
GG-25
0.6025
0.6025
0.6025
GG-25
RG-5
GG-25
0.6025
2.1096.01
0.6025
GG-25
AISI-316 AISI-316
0.6025
1.4408
1.4408
CF-8M
RG-5
GG-25
1.4408
2.1096.01
0.6025
AISI-316
AISI-316 AISI-316
1.4401
1.4401
1.4401
AISI-431B
AISI-431B AISI-431B
1.4057
1.4057
1.4057

4305
AISI-316
AISI-316
1.4408
AISI-316
1.4408
AISI-316
1.4401
AISI-316
1.4408
GG-25
0.6025
AISI-316
1.4408
AISI-316
1.4408
AISI-316
1.4408
AISI-316
1.4401
AISI-316
1.4401

4323
IMPINOX
GGG-40
0.7040
GGG-40
0.7040
F-114
1.1191
CF8M
1.4408
GG-25
0.6025
GG-25
0.6025
CF8M
1.4408
GG-25
0.6025
AISI-316
1.4401
AISI-431B
1.4057

(P) = Version with packing


(S) = Version with mechanical seal
( * ) = Material Denomination / Equivalent Werkstoff Number DIN-17007.

Pump
size

NL-

RECOMMENDED REPLACEMENT PARTS


Spares recommended for
2 years operation
1
1
1
1
2
1
2

Running
1
-

5 years operation
2
1
1
2
2
2
5
2
4

461
458
524

1
1
-

4
2
1

10
3
3

Simple mechanical seal


Shaft sleeve
Pin
Set of setscrews

433
523
560
904

1
1
1

1
1
1
1

2
1
2
2

Cierre DIN
equilibrado

Packing set
Packing lantern
Shaft sleeve

Balanced mechanical seal


Shaft sleeve
Pin

Cierre DIN
doble

Versin
empaquetadura

Wear ring
Pump shaft
Impeller
Protective deflector
Impeller nut
Set of bearings
Set of seals
Set of shaft keys
Set of sealing rings

Ref.
number
502
210
230
507
922
321.1 and 2
Set
940.1 and 2
425.1 and 2

Cierre DIN
simple

Piezas comunes

Title
of part

Double mechanical seal


Shaft sleeve
Pin
Set of setscrews

433.1
523
560
433.2 and 3
523
560
904

1
1

1
1
1

1
1
1

1
1
1
1

2
1
2
2
1
2
2

32/125
32/125
32/160
32/160
32/200
32/200
32/250
32/250
40/125
40/125
40/160
40/160
40/200
40/200
40/250
40/250
40/315
40/315
50/125
50/125
50/160
50/160
50/200
50/200
50/250
50/250
50/315
50/315
65/125
65/125
65/160
65/160
65/200
65/200
65/250
65/250
65/315
65/315
80/160
80/160
80/200
80/200
80/250
80/250
80/315
80/315
100/200
100/250
100/315
100/400
125/250
125/315
124/400
** 150/200
150/250
150/315
150/400

Flanges
DNd DNs
32

40

50

65

80

100

125

150

50

65

80

100

125

125

150

200

Pump dimensions
a
f
h1
h2
b
112 140
80 385 132 160
50
160 180
100 500 180 225
65
80
112 140
100* 385 132 160
50
160 180
100
180 225
500
65
225* 250
125
132 160
100 385
180
50
160
200
180 225
125 500
65
225 280
385
180
160
100
200
65
500 180 225
200 250
125
80
530 225 280
225
180
65
500
250
125
200* 280
80
530 250 315
125 500 200
280
225
80
140 530 250 315
280 355 100
250
80
355
140 530 280
100
315 400
500
370
280
530
400
160
100
280* 400*
670
315 450

m1
100

Dimensions in mm
Foot dimensions
m2
n1
n2
n3
190 140
70
240 190 110

125

95

100

70

125

95

100

70

125

95

125

95

160

120

125

95

160

120

320
210
240
265
320
345
240

250
160
190
212
250
280
190

265

212

320
345

250
280

280

212

320
360

250
280

400
320
345

315
250
280

400

315

360

280

400

315

160

120

200
160

150
120

500
400

400
315

200

150

500

400

200

150

450

s2

14

14

w
285

100

370
285
110

14

14

285
110

14

14

285
14

100

14
370

18

140

14
110

14

370

140

18

110

18

-9-

24

50

26,9

32

80

35,3

10

24

50

26,9

32

80

35,3

10

24

50

26,9

32

80

35,3

10

24

50

26,9

32

80

35,3

10

42

95* 45,1

12

32

80

35,3

10

42
32

95* 45,1
80 35,3

12
10

14

370

140

42

95* 45,1

12

14

370

140

42

95* 45,1

12

14
14

370

32
42

80 35,2
95* 45,1

10
12

14*

500

48

110

14

23
18
110

110*

23

23

180

* Dimensions out of the ISO-2858 standard. ** Adition to the standard.


NOTE.- ITUR Pumps practices a policy of continual development of its models. For this reason specifications are subject to change without notice.

-4-

100
370

110

Shaft end
l
t

100
370

550 450
110
550* 450*
550

s1

Sup.
y

51,5

Weight
in
Kg
35
40
49
77
36
45
50
80
95
43
49
58
85
104
49
65
75
90
116
79
95
107
125
100
120
140
210
136
209
230
176
209
220
240

CONSTRUCTION
Pump casing
With volute casing and support feet, it incorporates a wear ring.
The casing to cover sealing is effected by means of an embedded gasket.
Suction and discharge flanges
Integrally cast with the casing, constructed of GG-25 to DIN2533, and of steel to DIN-2543, crackle-finished "RF" to DIN2526 form C. Valid for connecting to commercial flanges DIN
PN-16. Optionally the casing can be supplied with other types of
flanges (ANSI, BS, DIN-2512, etc.).
Auxiliary connections
The standard version carries vent, drain, seal circulation,
pressure and vacuum gauge connections. All of these drilled
and closed off with the corresponding covers.
Pump cover
Casting in one piece, and independent of the seal design, it
incorporates several extractors in order to facilitate its removal.
Wear rings
All models incorporate a wear ring in the casing, in order to
facilitate repairs and make them cheaper.
Impeller
Closed impeller, cast in one piece, hydraulically and dynamically balanced, with dorsal fins in order to balance out the axial
thrust and to avoid the sedimentation of some suspended matter
which are carried together with the liquid. It is keyed to the shaft
and locked by means of a double nut.
Pump shaft
Well dimensioned, the shaft is especially resistant to bending. It
is provided with a replaceable shaft sleeve, sealed with the
shaft itself by means of a toroidal seal. Thus, changing the shaft
can be avoided, in the case of wear or abrasion in the sealing
area, achieving rapid, cheap maintenance. Included is a deflector next to the support in order to protect the ingress of liquid.

MOTOR SIZE AND POWER AT 50 Hz, IP-55, STANDARDIZED TO I.E.C.


Motor power in kW
Motor power in HP
M. size at 1.450 rpm
M. size at 2.900 rpm

0,55 0,75 1,1 1,5 2,2


3
4
5,5 7,5
0,75 1
1,5
2
3
4
5,5 7,5 10
80M 80M 90S 90L 100L 100L 112M 132S 132M
71M 80M 80M 90S 90L 100L 112M 112M 132S

11
15
160M
160M

15
20
160L
160M

18,5
25
180M
160L

22
30
180L
180M

30 37 45
40 50 60
200L 225S 225M
200L 200L 225M

NOTE.- ITUR Pumps practices a policy of continual development of its models. For this reason specifications are subject to change without notice.

- 10 -

55
75
250M
250M

75
100
280S
280S

90
125
280M
280M

110
150
315S
315S

132
180
315M
315M

160
220
315M
315M

Bearing support
Of modern design, it incorporates two total double seal ball
bearings, with grease for its entire lifespan and as such its
maintenance is not required during normal operation. The
bearing protection against external agents (water, dust, ...) is
effected by means of the lip seal.
-3-

Standard sealing systems


A wide variety of sealing systems can be incorporated, according
to the type of liquid to be pumped. The NL Series of ITUR Pumps
has for the standard version, provision for the following possibilities:
 Packing
Asbestos-free, provided with the corresponding lantern.
Cooling Plan API-11.
 Simple mechanical DIN seal
Standardized to DIN-24960, on the long version with locking
pin and choke ring. The material used in the contacting faces
depends upon the liquid to be pumped.
Cooling Plan API-11/61.
 Simple DIN balanced mechanical seal
Standardized to DIN-24960, on the long version with locking
pin and choke ring. Balancing is used when the pressure
generated in the pump requires it. The material used in the
contacting faces depends upon the liquid to be pumped.
Cooling Plan API-11/61.
 DIN double mechanical seal ("back to back")
Standardized to DIN-24960, on the short version with locking pin
only on the process side, and choke ring. The material used in the
contacting faces depends upon the liquid to be pumped.
Cooling Plan API-54.

Optional sealing systems


The NL Series allows for the inclusion, on request, of the other
types of shaft sealing:
 External mechanical seal
Of type 10 T without protective screen or safety ring.
 Mechanical seal, not to DIN
Seals with conform to special standards or which are of
special sizes.

Baseplate and coupling


The driving of the pump by the motor is effected via a semiflexible coupling. The assembly is mounted on a baseplate
standardized to ITUR. Optionally the coupling can be supplied
with a spacer, which allows easy access to the pump interior
without the need to remove the pipes or the motor. In this case,
the baseplate is constructed according to ISO-3661.

DESCRIPTION

RANGE OF THE SERIES

The NL range of pumps are single-stage horizontal centrifugal


pumps, with axial suction and radial discharge, built to Standard
ISO-2858 (DIN-22858), evolved as a result to applying technological
innovation to the design and manufacture of the pumps for industrial
processes.

The NL Series covers a total of 41 models with closed impeller, based


of 34 pump sizes, where each different size allows for one or two types
of impeller (A or B).
Service limits
- Maximum flow: .......................................... 700 m3/h
- Maximum height differential ...................... 100 w.c.m.
- Maximum casing pressure (at 20 C)
* Executions 04 and 05: ............................ 16 Kg/cm2
* Executions 00, 01, 02 and 03: ................ 10 Kg/cm2
- Maximum suction pressure ....................... 5 Kg/cm2
- Maximum speed ........................................ 3.600 rpm
- Maximum temperature .............................. 140 C
- Maximum viscosity .................................... 20 cSt (2,9 E)

These pumps are based on the sturdy design of NM series (medium


duty), and they are designed to work in processes with divers types of
liquids and with appropriate materials and mechanical seal. The characteristics of the NL Series are:
-

High hydraulic efficiency.


Sturdy design (24/24 hours).
Wide variety of materials available, according to the liquid being pumping.
Different sealing systems with standardized channels.
Different seal cooling plans.
Modular pumps (component versatility).
Standardized parts with high degree of interchangeability.
Minimal and rapid maintenance.

Although these pumps are normally driven by electric motor mounted on


a bed frame, other power drive sources may be used (diesel engine,
steam turbine, hydraulic motor, ...).

APPLICATIONS
The NL Series of ITUR Pumps has been specially conceived for the
pumping of a wide variety of liquids, generally without, or with slight
suspended matter, such as:
-

Clean liquids
Corrosive or abrasive liquids
High density liquids
Viscous liquids

Note.- With consultation, some of the limits laid down for the standard
construction can be exceeded.

Pump
size

Flanges
NL- DNd DNs
32/125 32
50

Assembly dimensions
a
f h1 h2 L5 x
80 385 112 140 60 3

32/160
32/200
40/125
40/160
50/125

32
32
40
40
50

50
50
65
65
80

80
80
80
100
100

40/200
50/160
50/200

40
50
50

65
80
80

100 385 160 180 60


100 385 160 180 60
100 385 160 200 60

After removing the spacer, the assembly made up of the support, cover
and impeller is removed, the pump casing and the motor always
remaining attached to the bed-plate. The suction and discharge pipes
remain connected.
In this way, maintenance is easier for these pumps that are working
during industrial processes.

385
385
385
385
385

132
160
112
132
132

160
180
140
160
160

60
60
60
60
60

3
3
3
3
3

210/3
197
225
177
197
197

197
225
177
197
197

Baseplate number 753


3
3

65/125

65

100 100 385 160 180 75

32
40

50
65

100 500 180 225 75


100 500 180 225 75

3
3

100 100 500 160 200 75


65
80
80
100
100
125
125
125

125
125
125
100
125
125
125
125

500
500
500
500
500
500
500
500

225
180
225
180
200
180
180
200

250
225
280
225
250
225
250
280

75
75
75
75
90
75
75
90

80

125 125 500 200 280 90

350

100
125
125
125
150

125
125
140
140
140

530
530
530
530
530

225
250
225
250
250

280
315
280
315
355

90
90
90
90
90

100/400 100
125/315 125
125/400 125

125 140 530 280 355 110


150 140 530 280 355 110
150 140 530 315 400 110

350/1

225 225 280


225 225 280
225 225 280

200 160 500 280 370 110


200 160 530 280 400 110

150/315 150
150/400 150

200 160 670 280 400 110


200 160 670 315 450 110

300/1

3
3
3
3
3
3
3
3

290
245 245
290
245 245 245
265
245
245 245
265 265

290
245
290
245
265
245
245
265

290
245
290
245
265
245
245
265

290
245
290
245
265

245
325
245
300
280
245 280
265 300

NL-100/250.B
NL Series
DN of discharge outlet, in mm
Nominal diameter of impeller, in mm
closed, design A
closed, design B

-2-

b2
300
360
390
440
440
470
470
520
520
520
620
620
670
670

430/2

280 280

300

325 350

245 245
300
280 280
280
300 300

300
300
300
300
300

325
325
325
325
325

380/6

430/2

530/1

300 300 300 300 300 300 300 300

430/3

3
3
3
3
3

430/4

325 325 325 325


350 350 350 350
325 325 325 325 325 325
350 350 350
350 350 350 350 350 350

430/3

430/4

325
350
325
350
350

350
350 (*)
350
350 (*)
350 (*)

530/2

530/1

530/2

(*)
(*)
(*)

] 120

(*)

(*)

] 160

325
350 350
325 350 (*)
350 350 350 350
350 350

430/2

530/2

530/1

530/2

(*)

] 120

380 380 380 380 380 380 (*)


380 380 380 380 380 380 380 (*)
415 415 415 415 415 (*)

3
3

(*)

] 120

325 350 (*)

430/2

3
3
3

580/2

(*)

(*)

] 160

(*)
(*)

] 120

(*)

(*)

] 160

380 380 380 380 380


380 380 380 380 380 380 380

580/3

3
3

Dimensions in mm
L1
L2
L3
760
510
125
770
520
125
880
580
150
750
500
125
850
600
125
1000
700
150
1150
750
200
1250
750
250
1000
700
150
1100
800
150
1240
740
250
1370
870
250
1360
860
250
1200
700
250

325

530/1

300

380/6

380

300

430/2

260 260 280

300/2

580/1
380 380 380 380 380 (*)
415 415 (*)

580/2

(*)
(*)

] 120

(*)
(*)

(*)

(*)

] 160

(*) Baseplate not standardized, with welded U beans. Please,


consult the specific plan.

PUMP DENOMINATION
b1
260
320
350
400
400
430
430
480
480
480
580
580
630
630

430/4

380/6

225 225 225 225 225

Baseplate number 75-

Baseplate
number
75-210/3
75-270/5
75-300/1
75-350
75-350/1
75-380
75-380/6
75-430/2
75-430/3
75-430/4
75-530/1
75-530/2
75-580/1
75-580/3

300

380/6

225

Baseplate number 75150/200 150


150/250 150

300

380

380

Baseplate number 75-

Type of impeller:

380

245 245 245 245


245
280 280
245 245 245 245 245 245 245 280 280 280

Baseplate number 75-

Process Industries
Chemical Industry
Paint booths
Vehicle Industry
Food Industry
Paper Industry
Water supply
Irrigation

225
225

380

350/1

Baseplate number 7565/315 65


80/315 80
100/250 100
100/315 100
125/250 125

225
225

300/1

Baseplate number 7580/250

197
225
197
197
197

225 225 225 225 225 225

Baseplate number 7540/315 40


50/250 50
50/315 50
65/200 65
65/250 65
80/160 80
80/200 80
100/200 100

300/1

197
225
177
197
197

300/1

350

Baseplate number 7565

197
225
177
197
197

270/5

Baseplate number 7532/250


40/250

270/5
197
225
177
197
197

225 225 225 225 225 225


225 225 225 225 225 225
225 225 225 225 225 225

Baseplate number 75-

65/160
The standard version of the electro-pump unit embodies the normal
semi-flexible coupling. Upon request, this coupling can be supplied with
a spacer. The use of the semi-flexible coupling with spacer allows easy
access to the pump interior without the need to remove the pipes or the
motor.

Dimensions in mm
Head -h 3- and the standardized baseplate type, in terms of motor size (I.E.C.)
80M 90S 90L 100L 112M 132S 132M 160M 160L 180M 180L 200L 225S 225M 250M 280S 280M 315S 315M
177 177 177 177 177 177

Baseplate number 75-

EASE OF MAINTENANCE

These pumps are designed for pumping systems of industrial processes, where a sturdy larger margin and the reliability of the operating
are necessary. As a result, this Series is ideal in:









ELECTROPUMP DIMENSIONS STANDARDIZED TO ITUR

L4
-

S
18
18
18
18
18
18
18
18
18
18
18
18
18
18

T
6
6
6
6
6
6
30
30
30
30
30
30
30
30

- 11 -

BASEPLATE DIMENSIONS
STANDARDIZED TO ITUR

NL series
Pumps for industrial processes

CI-NL/A349-5 (11/02)

(Standardized to ISO-2858/DIN-24256)

BOMBAS ITUR, S.A.


P.O. Box, 41
20800 ZARAUTZ (Gipuzkoa) SPAIN
Tel.: +34 943 899 899 Fax: +34 943 130 710
E.Mail: comexp@itur.es www.itur.es

S-ar putea să vă placă și