FANUC Series 0i / 0i Mate-MODEL D MAINTENANCE MANUAL An amendment of the option information file. Option parameters are stored in an option information file (with file name "OPRM INF") in the FROM module. The certification of the option parameters by FANUC Service is required within the expiration date.
FANUC Series 0i / 0i Mate-MODEL D MAINTENANCE MANUAL An amendment of the option information file. Option parameters are stored in an option information file (with file name "OPRM INF") in the FROM module. The certification of the option parameters by FANUC Service is required within the expiration date.
FANUC Series 0i / 0i Mate-MODEL D MAINTENANCE MANUAL An amendment of the option information file. Option parameters are stored in an option information file (with file name "OPRM INF") in the FROM module. The certification of the option parameters by FANUC Service is required within the expiration date.
DRAW. NO B-64305EN/03-01 CUST. 01 10/03/23 New issued SAKAMOTO TITLE FANUC Series 0i/0i Mate-MODEL D MAINTENANCE MANUAL An amendment of the option information file
SHEET 1 / 3
FANUC Series 0i/0i Mate-MODEL D MAINTENANCE MANUAL An amendment of the option information file
1. Type of applied technical documents Name FANUC Series 0i/0i Mate-MODEL D MAINTENANCE MANUAL Spec. No. / Version B-64305EN/03
2. Summary of change Group Name / Outline New, Add., Correct, Del. Applicable Date Basic Function
Optional Function
Unit
Maintenance Parts
Notice The section 4.11 is modified. NOTE in APPENDIX C.2.1 is modified. Correction
Another
Edit. DATE Design Description DRAW. NO. B-64305EN/03-01 CUST.
TITLE
SHEET 2 / 3
The section 4.11 is changed The option information file,modified in the section 4.11. 4.11 The option information file This CNC supports the FANUC Remote Option System.
The note in the restoration of the option information file 1) Optional parameters are stored in an option information file (with file name OPRM INF) in the FROM module. Please also back up the option information file (file name: OPRM INF) in the FROM, when you back up the SRAM memory and the user files. This is for easy recovery in case of data loss. 2) If once the option information file is restored, P/S alarm No.5523 (WAITING THE OPTION CERTIFICATION) occurs when the power is turned on. Then, the certification of the option parameters by FANUC Service is required within the expiration date (30 days (720 hour) after Alarm occures.). (The P/S alarm No.5523 can be canceled by reset within the expiration date.) Request FANUC Service to certify the option parameters.
Edit. DATE Design Description DRAW. NO. B-64305EN/03-01 CUST.
TITLE
SHEET 3 / 3
NOTE is modified in APPENDIX C.2.1.
C2.1 USER DATA LOADING/SYSTEM DATA LOADING Screen
NOTE 1 The option parameters of the CNC are saved in the option information file (OPRM INF). If this file is modified, the option parameters need to be certified because the settings of the option parameter are assumed to be changed by FANUC Service. Request FANUC Service to certify the option parameters. 2 Since the option information file (OPRM INF) may be necessary when the printed circuit board is replaced, it is recommended that this file be backed up in advance as in SRAM data.