0 evaluări0% au considerat acest document util (0 voturi)
114 vizualizări4 pagini
Blending system modules are based on the experience and quality of the Smith Meter brand. Ratio Blending has become the industries main blending method because of the most constant blend quality even at interrupted operations. Each standard skid supports up to four 2" blend streams; more streams are optional.
Blending system modules are based on the experience and quality of the Smith Meter brand. Ratio Blending has become the industries main blending method because of the most constant blend quality even at interrupted operations. Each standard skid supports up to four 2" blend streams; more streams are optional.
Blending system modules are based on the experience and quality of the Smith Meter brand. Ratio Blending has become the industries main blending method because of the most constant blend quality even at interrupted operations. Each standard skid supports up to four 2" blend streams; more streams are optional.
The introduction of biofuels into the mainstream fuels market business has generated the need for a signicant investment in the appropriate technology and processes to ensure that the product reaching the end consumer is of the right quality and can be produced repeatedly without the need for additional quality controls. FMC Technologies blending system modules are based on the experience and quality of the Smith Meter brand. These modules, created for the International Markets including the European Market, have been designed to fulll internal and logistical requirements and to comply with all Weights & Measures requirements. Of all available blending methods, ratio blending has become the industries main blending method because of the most constant blend quality even at interrupted operations. BENEFITS Each standard skid supports up to four 2" blend streams; more streams are optional The standard blend rates are 2% to 25% at a typical loading of 2,400 L/min Pre-congured and pretested at the factory Minimum footprint is suitable for new and upgrade installations Support for Ratio Blending, Side Stream Blending and Wild Stream Blending Options for individual congurations Full factory ow and functionality testing providing fault-free start up Comes with all approvals and certicates ISO certied production We put you rst. And keep you ahead. SALES BULLETIN MEASUREMENT SOLUTIONS Smith Meter Blending Systems 2 Ratio Blending Setup Outlet Blended Product Centralized Inlet Bio Component Inlet Main Product Ratio Blending Ratio blending refers to the mixing of the main fuel stream and the bio component stream in the correct ratio, where the main fuel stream is considered a variable ow and the bio component ow must be controlled in the correct ratio. Typically the term ratio blending is used where the biostream is mixed with the main fuel stream downstream of the main fuel meter and managed with one electronic controller device managing all ow control valves. With this blending method the blending stream is considered as part of custody transfer metering. The main advantage for ratio stream blending is that all nal product components are individually and accurately measured, thus enabling correct inventory reconciliation providing the most accurate nal custody transfer volume information. A typical application is Ethanol blending. Wild Stream Blending If the blending component stream is separately controlled from the main fuel stream, then it is often called wild stream blending, where the main fuel ow stream is the wild stream (uncontrolled stream) and the blend component is controlled as a percentage of the main stream and blended typically upstream (alternatively downstream) of the main stream owmeter. PSV 2 DBBV 4 DBBV 4 FCV 15 TT 5 BV 3 BV 3 BV 3 FCV 7 FQI 6 BV 3 BV 3 FQI 6 FCV 7 BV 3 4" Inlet Biofuel P P Outlet Connection for Calibration Prover Meter Run Line 4 Blending Skid Optional Loading Skid Extension 2" 2" 2" 2" 2" 2" 2" 4" 3" 3" 3" 4"/3" 4"/3" Inlet Connection for Calibration MTR MTR Drain 1 1/2" Vent 1 1/2" NPT Drain 3/4" NPT STR Meter Run Line 3 Line 1 2" Skid Drain 1 1/2" 4" Inlet Main Product BV 13 F 8 PSV 2 Drain 1 1/2" NPT APS Vent 3/4" NPT 4" MTR 3/4" NPT Connection Additive System FQI 9 FEJCSRA 11 AL III Q TT 5 FCV 10 4" CV 14 CV 12 2" Outlet 4" RATIO BLENDING P&ID SCHEMATIC EXAMPLE 3 Side Stream Blending Setup Outlet Blended Product Side Stream Blending Side stream blending is an alternative term for ratio blend- ing, but where the blend stream is mixed with the main fuel upstream of the main fuel meter. The blend meter is managed by the main stream electronic controller device. To ensure the accuracy of the blend, this blending method has blend stream accuracy requirements which are equivalent to the premium level of the main stream custody transfer metering. The main advantage for side stream blending is that typically the side stream is legally not considered as custody transfer. A typical application is biodiesel blending. Wild Stream Blending Setup with its own Controller SIDE STREAM BLENDING P&ID SCHEMATIC EXAMPLE PSV 2 DBBV 4 DBBV 4 FCV 15 TT 5 BV 3 BV 3 BV 3 FCV 7 FQI 6 BV 3 BV 3 FQI 6 FCV 7 BV 3 4" Inlet Biofuel P P Outlet Connection for Calibration Prover Meter Run Line 4 Blending Skid Optional Loading Skid Extension 2" 2" 2" 2" 2" 2" 2" 4" 3" 3" 3" 4"/3" 4"/3" Inlet Connection for Calibration MTR MTR Drain 1 1/2" Vent 1 1/2" NPT Drain 3/4" NPT STR Meter Run Line 3 Line 1 2" Skid Drain 1 1/2" 4" Inlet Main Product F 8 PSV 2 Drain 1 1/2" NPT APS Vent 3/4" NPT 4" MTR 3/4" NPT Connection Additive System FQI 9 FEJCSRA 11 AL III Q TT 5 FCV 10 4" Outlet 4" CV 12 CV 14 BV 3 2" 4" www.fmctechnologies.com/measurementsolutions 2013 FMC Technologies. All rights reserved. SBSM007A7E Issue/Rev. 0.1 (3/13) FMC Technologies Measurement Solutions, Inc. 500 North Sam Houston Parkway West, Suite 100 Houston, Texas 77067 USA P:+1 281.260.2190 Germany Operation Smith Meter GmbH Regentstrasse 1 25474 Ellerbek, Germany P:+49 4101.304.0 We put you rst. And keep you ahead. Conguration Samples for Blending Skids BLENDING SKIDS WITHOUT PROVING CONNECTION, CENTRALIZED INLET BLENDING SKIDS ADDITIONALLY WITH CENTRALIZED PROVING CONNECTION Air Vent Device Strainer Ball Valve Inlet 4" or DN100 PT100 Extension No. 4 Extension No. 2 Drain ANSI B16.5 1 1/2" - 150lb Ball Valve Extension No. 3 Frame Stainless Steel Wide Range Meter Type Genesis Isolation Valve Flow Control Valve Ball Valve Outlet 2" or DN50 AC & DC Junction Boxes Prover Return Connection for Calibration Double Block & Bleed Valve Prover Inlet Connection for Calibration For calibration with master meter or SVP.