Sunteți pe pagina 1din 68

Catalogue

2009
R A D I A T O R S F O R L I F E
RADI ATORS FOR LI FE
Floor convectors Licon PK
Floor convectors with fan
Floor convectors Licon PKVTi with aftercooling effect
Floor convectors Licon PKVTi TWIN with fan and aftercooling effect
7
12
15
17
FLOOR MOUNTED RADIATORS
Bench convectors Licon OL
Bench convectors Licon OL/D with cover grid
Wall bodies Licon OK/C - Ceramic
Wall bodies Licon OK
Heating registers Licon OR
FLOOR RADIATORS
WALL MOUNTED RADIATORS
TECHNICAL INFORMATION
Mounting instructions
Pressure losses, weights, volumes
General information
References
25
31
37
41
45
50
59
63
65
2
Content
COVER GRID, DESIGN SHAPES
PM cover grids of floor convectors
Design shapes and accessories
20
22
Dear business friends,
Company LICON has been almost 5 years active on the mar-
ket. We succeeded in following the 40-year tradition of manu-
facture of Likov convector bodies. Our production portfolio
has been growing constantly, and the existing products are
permanently innovated as you can learn from this catalogue.
We would like to introduce you three brand new products
from the new catalogue. First group consists of floor convec-
tors with aftercooling effect. Again, In designing these prod-
ucts we cooperated with experts in the specific area, including
specialists from abroad. The result is a very effective fan-coil
with a brand new type of Al/Cu at the exchanger, which was
ideally designed both for heating and aftercooling. The plat-
ing (tub) of the convector is manufactured by a unique system
of tub-in-tub when a second tub is built in the bottom of
the convector which serves for trapping and drainage of the
condensate, pool water, etc. Fan-coils are produced in two de-
signs: - a double-tube (heats or cools), and a four-tube (both
heats and cools). Heating and cooling outputs were measured
in a prominent test laboratory HLK Stuttgart. See the cata-
logue for more detailed information.
Another novelty in the LICON CERAMIC production pro-
gramme is an intelligent heating element, mantle of which is
made of ceramic tiles. This is an absolute novelty in the world
of heating elements. The radiator is equipped with its own
integrated control electronics, fans with very low noise level of
only 21.4 dB and, first of all, it is a very original radiator that
can be installed where above-standard and original design is
required. See the catalogue for more detailed information.
This year we have also improved our web presentation
on www.licon.cz. Now we are much more flexible in handing
over current information. The sites will provide you with much
more interesting information that cannot be squeezed in the
printed catalogue.
We believe that you will certainly appreciate also the
shortened delivery time of products which we usually delivery
within 3 or 12 working days. Contact our commercial depart-
ment for more detailed information about the delivery terms
of individual products.
We treasure our interest in the products of our company
and we do our best to satisfy you.
Martin Kniha
Executive
Manufacture of Licon heating elements proceeds using most
sophisticated technologies. Majority of production operations
is executed on CNC machines. Surface treatment of elements is
executed using powder epoxy-polyester pains on an ecologi-
cally-saving line.
R A D I A T O R S F O R L I F E
www.licon.cz
3
About company
RADI ATORS FOR LI FE
4
Certificates
FLOOR MOUNTED
R A D I A T O R S
Floor-mounted convectors
Licon PK
R A D I A T O R S F O R L I F E
7
8
floor-mounted convectors Licon PK
depths 9, 11, 15, 19, 30, 45 cm
widths 16, 20, 28, 42 cm
lengths 80 to 300 cm
outputs from 97 to 4095 W
maximum working pressure 1,2 MPa
maximum working temperature 110C
connecting threat internal G 1/2
case design steel, stainless steel 1.4400
Specification
The Licon PK convector is designed for embedding in the floor, mainly at places where no higher elements can be located, e.g.
near French windows, near passages to winter gardens, entries to halls, exits, etc., in public buildings (shops, administration
buildings, etc.) and also in family houses. Various colour combinations of cover grids then ensure suitability of these convectors
for any type of interior.
Use in interiors
9
floor-mounted convectors Licon PK
160
110
200
150
280
235
420
376
160
110
200
150
280
235
420
376
280
235
420
376
280
2ar
420
376
280
235
420
376
280
235
420
376
9
0
1
1
0
1
5
0
1
9
0
3
0
0
4
5
0
15 mm weep hole
( for rustless tub designs only)
Depth 9 cm Depth 19 cm
Element sections
Depth 11 cm Depth 15 cm
Depth 30 cm Depth 45 cm
www.licon.cz
Location of heat exchanger
The dimensions in the schemes are in mm.
The stated dimensions do not include decorative frame.
max. 20 cm
10
floor-mounted convectors Licon PK
Table of heat outputs
Standard order contains
steel tub, varnished in RAL 9005 shade - black
heat exchanger with low water content and uniquely
shaped lamellas for higher heat output, fitted with air-
relief valve G 1/4 or G 1/2
anodised Al frame, U profile, colour of natural aluminium
fixation anchors to fasten the canal to the floor
a pair of flexible rustless hoses for easy attachment
a soloit cover plate, protecting the exchanger from dust
and impurities at the construction site
set screws to level floor unevenness
mounting instructions of element
The assembly is wrapped in a solid PVC foil with edge
protectors.
Cover grids see Page 20
Optional specification
stainless tub design
anodised Al frame, F profile (see the sketch on Page 20)
colour of frame natural aluminium, shining gold (suitable
for combination with wooden grid), bronze
black paint coati of heat exchanger
For technological reasons wooden frame cannot be supplied.
Pressure losses see Page 60
t Correction factor for variant temperature
difference of Licon PK elements
Heat outputs (W) at tw1/tw2/ti = at 85/75/20C (t=60) and at 75/65/20C (t=50) according to CSN EN 442
CATALOGUE No.
PK length/depth/width (in cm) profile of frame [U, F see the sketch on Page 20] frame shade [S-silver, Z-gol, B-bronze] rustless tub design (stainless)
Example: PK 100/11/28 UZ =PK convector with steel tub, of 100 cm length, 11 cm depth and 28 cm width, provided with a U-profile frame in gold.
If specification of decorative frame and the tub material design will be missing in the order, it will be made of steel plate and fitted with silver frame of U-shape.
W
!
Depth
(cm)
t
Length L (cm)
80 100 120 140 160 180 200 220 240 260 280 300
W
i
d
t
h

1
6
9
t 60 129 180 231 282 333 384 436 487 538 589 640 691
t 50 97 135 173 212 250 289 327 365 404 442 481 519
11
t 60 157 219 282 344 407 469 531 594 656 719 781 843
t 50 118 165 212 258 305 352 399 446 493 540 586 633
W
i
d
t
h

2
0
9
t 60 155 216 278 339 401 463 524 586 647 709 770 832
t 50 116 162 209 255 301 347 393 440 486 532 578 624
11
t 60 189 264 339 414 489 564 639 714 790 865 940 1015
t 50 142 198 255 311 367 424 480 536 593 649 705 762
W
i
d
t
h

2
8
9
t 60 201 281 361 441 521 601 681 761 840 920 1000 1080
t 50 151 211 271 331 391 451 511 571 631 691 751 811
11
t 60 233 326 418 511 604 696 789 882 974 1067 1159 1252
t 50 175 245 314 384 453 523 592 662 731 801 870 940
15
t 60 283 395 507 620 732 844 957 1069 1181 1293 1406 1518
t 50 212 297 381 465 549 634 718 802 887 971 1055 1140
19
t 60 312 436 560 684 808 932 1056 1180 1304 1427 1551 1675
t 50 234 327 420 513 606 699 793 886 979 1072 1165 1258
30
t 60 419 586 753 919 1086 1253 1419 1586 1753 1919 2086 2252
t 50 315 440 565 690 815 940 1066 1191 1316 1441 1566 1691
45
t 60 646 902 1159 1416 1672 1929 2186 2442 2699 2956 3212 3469
t 50 485 678 870 1063 1256 1448 1641 1834 2026 2219 2412 2604
W
i
d
t
h

4
2
9
t 60 362 506 650 794 937 1081 1225 1369 1513 1657 1801 1944
t 50 272 380 488 596 704 812 920 1028 1136 1244 1352 1460
11
t 60 416 582 747 912 1078 1243 1408 1574 1739 1904 2070 2235
t 50 312 437 561 685 809 933 1057 1181 1306 1430 1554 1678
15
t 60 497 694 891 1088 1286 1483 1680 1878 2075 2272 2469 2667
t 50 373 521 669 817 965 1113 1261 1410 1558 1706 1854 2002
19
t 60 548 766 983 1201 1419 1637 1854 2072 2290 2508 2725 2943
t 50 411 575 738 902 1065 1229 1392 1556 1719 1883 2046 2210
30
t 60 731 1021 1311 1602 1892 2182 2473 2763 3053 3344 3634 3924
t 50 549 766 984 1202 1420 1638 1856 2074 2292 2510 2728 2946
45
t 60 1016 1419 1823 2226 2630 3033 3437 3840 4244 4648 5051 5455
t 50 762 1065 1368 1671 1974 2277 2580 2883 3186 3489 3792 4095
Temperature index m =1.572
t (K) 20 22 24 26 28 30 32
kt 0,237 0,275 0,315 0,358 0,402 0,448 0,496
t (K) 34 36 38 40 42 44 46
kt 0,545 0,596 0,65 0,704 0,76 0,818 0,877
t (K) 48 50 52 54 56 58 60
kt 0,938 1,000 1,064 1,129 1,195 1,263 1,332
Floor-mounted convectors
Licon PKVT, PKVTi, PKVTi-TWIN
R A D I A T O R S F O R L I F E
11
12
floor-mounted convectors with fan Licon PKVT
depths 7.5, 9, 11 cm
widths 28, 42 cm
lengths 90, 120, 160, 200, 240, 280 cm
outputs from 123 to 6582 W
maximum working pressure 1,2 MPa
maximum working temperature 110C
connecting threat internal G 1/2
case design steel, stainless steel 1.4400
Service voltage of fans max.12V AC
Specifikace
Where the Licon PK floor-mounted convector is not sufficient in terms of its output, more productive heat source must be se-
lected. To satisfy this demand, a floor-mounted Licon PKVT convector was designed with tangential fan. The Licon PKVT convec-
tor extends usefulness of Licon PK convectors even to areas with higher thermal losses. The speed of fan rotation can be changed
fluently in dependence on instant room temperature, which allows the PKVT convector to react flexibly to the temperature
demand. The convectors are equipped with 230/12V transformer, installed inside the tub under the cover grid. Maximum service
voltage of fans is 12V AC. The stainless design of the convector tub anticipates its location in damp environment, therefore the
transformer is, for safety reasons, supplied separately in a mounting box for wall mounting. The turns of the fan can be changed
alternately or continuously, depending on the electric control type used basic (alternately), automatic (continuously). The PKVT
model serves for heating only.
Use in interiors
13
floor-mounted convectors with fan Licon PKVT
Depth 7.5 cm Depth 9 cm
The dimensions
in the schemes
are in mm.
The stated
dimensions do not
include decorative
frame
Depth 11 cm
Noise level of floor-mounted convectors
with fan
(acoustic pressure 1m from convector)
Element sections
www.licon.cz
weep hole 15 mm (for
rustless tub designs only)
Steel design
Depth 11 cm (applies for both 28 and 42 cm widths)
1 st level 27 dbA
2 nd level 34 dbA
3 rd level 41 dbA
Depth 9 cm
1 st level 25 dbA
2 nd level 30 dbA
3 rd level 37 dbA
Depth 7,5 cm
1 st level 25 dbA
2 nd level 31 dbA
3 rd level 38 dbA
*230/12 transformer
(fitted inside the tub
for steel design only)
* If the convector tub is all made of steel, the transformed is not installed inside the tub
but supplied separately in a mounting box see Mounting Instructions.
Table of heat outputs
Heat outputs (W) at tw1/tw2/ti = at 85/75/20 C (t=60) and at 75/65/20 C (t=50) according to CSN EN 442
Standard order contains
steel tub, varnished in RAL 9005 shade - black
heat exchanger with low water content and uniquely
shaped lamellas for higher heat output, fitted with air-
relief valve G 1/4 or G 1/2
tangential fans along the entire length of the heating area
of th heat exchanger, top fan filter
230/12 V transformer, coverage IP 54, including 5 m
connecting cable
covers of transformer and connecting hoses in the colour
of the tub
anodised Al frame, U profile, colour of natural aluminium
if a stainless tub is ordered, the transformed is supplied
separately in a mounting box, its size must be calculated
according to the number of fan-coils, see the Mounting
section for precise mounting description
fixation anchors to fasten the canal to the floor
a pair of flexible rustless hoses for easy attachment
a sololit cover plate, protecting the exchanger from dust
and impurities at the construction site
set screws to level floor unevenness
mounting instructions of element
The assembly is wrapped in a solid PVC foil with edge
protectors
Optional specification
stainless tub design
warning: Does not contain trans-former!
anodised Al frame, F profile (see the sketch on Page 20)
colour of the frame natural aluminium, gold, bronze
black paint coati of heat exchanger
For technological reasons wooden frame cannot be supplied.
PKVT type
(length/
depth/width)
t
Fan
switched
off
1. st
level
2. nd
level
3. rd
level
Maximum
fan input
(VA)
90/7/28
t 60 155 853 907 913
34
t 50 123 703 748 753
120/7/28
t 60 208 1321 1405 1426
50
t 50 165 1089 1158 1176
160/7/28
t 60 277 1804 1926 1903
84
t 50 220 1487 1588 1569
200/7/28
t 60 346 2282 2428 2467
100
t 50 275 1881 2002 2034
240/7/28
t 60 416 2760 2935 2980
134
t 50 330 2275 2420 2457
280/7/28
t 60 485 3258 3467 3519
150
t 50 385 2686 2858 2901
PKVT type
(length/
depth/width)
t
Fan
switched
off
1. st
level
2. nd
level
3. rd
level
Maximum
fan input
(VA)
90/9/28
t 60 162 878 935 995
34
t 50 129 724 771 820
120/9/28
t 60 218 1360 1447 1539
50
t 50 173 1121 1193 1269
160/9/28
t 60 291 1857 1984 2077
84
t 50 231 1531 1636 1712
200/9/28
t 60 364 2350 2501 2661
100
t 50 289 1937 2062 2194
240/9/28
t 60 437 2842 3023 3216
134
t 50 347 2343 2492 2651
280/9/28
t 60 590 3356 3571 3798
150
t 50 404 2767 2944 3131
PKVT type
(length/
depth/width)
t
Fan
switched
off
1. st
level
2. nd
level
3. rd
level
Maximum
fan input
(VA)
90/11/28
t 60 253 975 1120 1255
51
t 50 207 799 918 1029
120/11/28
t 60 429 1541 1771 1984
69
t 50 352 1263 1452 1626
160/11/28
t 60 599 2050 2463 2758
120
t 50 491 1680 2019 2261
200/11/28
t 60 726 2763 3177 3559
170
t 50 595 2265 2604 2917
240/11/28
t 60 895 3510 4035 4519
190
t 50 734 2877 3307 3704
280/11/28
t 60 1081 4423 5084 5695
204
t 50 886 3625 4167 4668
PKVT type
(length/
depth/width)
t
Fan
switched
off
1. st
level
2. nd
level
3. rd
level
Maximum
fan input
(VA)
90/11/42
t 60 371 1433 1646 1845
51
t 50 304 1175 1349 1513
120/11/42
t 60 636 2280 2622 2936
69
t 50 521 1869 2149 2406
160/11/42
t 60 884 3023 3633 4069
120
t 50 724 2478 2978 3335
200/11/42
t 60 1074 4090 4702 5267
170
t 50 881 3352 3854 4317
240/11/42
t 60 1312 5142 5911 6620
190
t 50 1075 4215 4845 5426
280/11/42
t 60 1524 6236 7168 8030
204
t 50 1249 5111 5875 6582
Electric control of Licon PKVT elements see
Page 52.
t Correction factor for variant temperature
difference of elements
CATALOGUE No.
PKVT length/depth/width (in cm) profile of frame [U, F see the sketch on Page 20] frame shade [S-silver, Z-gold, B-bronze] rustless tub design (stainless)
Example: PKVT 120/11/28 UZ = convector with PKVT fan with steel tub, of 120 cm length, 11 cm depth and 28 cm width, provided with a U-profile frame in gold.
If specification of decorative frame and the tub material design will be missing in the order, it will be made of steel plate and fitted with silver frame of U-shape.
W
!
14
floor-mounted convectors with fan Licon PKVT
Temperature index m =1.09
t (K) 20 22 24 26 28 30 32
kt 0,368 0,410 0,450 0,490 0,532 0,570 0,615
t (K) 34 36 38 40 42 44 46
kt 0,657 0,700 0,740 0,784 0,827 0,870 0,913
t (K) 48 50 52 54 56 58 60
kt 0,956 1,000 1,045 1,090 1,130 1,180 1,220
Cover grids see Page 20
Pressure losses see Page 60
15
floor-mounted convectors with fan Licon PKVTi
depth 13 cm
width 28 cm
lengths 120, 200, 300 cm
heat outputs max. 6905 W
cooling outputs max. 2356 W
maximum working pressure 1,2 MPa
maximum working temperature 110C
connecting threat internal G
case design steel, stainless steel 1.4400
service voltage of fans max.12V AC
Specification
PKVTi- floor-mounted convector serving for heating or cooling of room. For this purpose a brand new design of Al/Cu of
exchanger is used, which was ideally designed both for heating and aftercooling. In case of low construction depth the convec-
tor has therefore excellent thermal and cooling outputs, measured in HLK Stuttgart. The tub of the convector is equipped with
a unique system of gtub-in-tub when a stainless piece is built in the existing steel tub which serves for trapping and drainage
of potential condensate.
The fans used are tangential fans with max. 12 V voltage, the regulating system is identical with that of the PKVT fan-coils al-
ready produced.
Use in interiors
W
!
16
floor-mounted convectors with fan Licon PKVTi
Heat output without fan is 231W/bm at 75/65/20C. Cooling output at other cooling drift than the above stated contact the manufacturer for information.
CATALOGUE code: PKVTi length (in cm), frame profile (U,F), shade of frame [S-silver, Z-gold, B-bronze]; rustless tub design (stainless).
Example: PKVTi 120 UZ = convector with PKVTi fan with steel tub, of 120 cm length, provided with a U-profile frame in gold.
If specification of decorative frame and the tub material design will be missing in the order, it will be made of steel plate and fitted with silver frame of U-shape.
Table of cooling and heat outputs

Cooling output t1 C
Speed of rotation 1 2 3 1 2 3 1 2 3
Humidity % Cooling outputs are stated in Watts. Cooling outputs were measured in accordance with the EN 145187 standard.
6/12C
28 50 406 610 715 627 964 1507 865 1344 2356
26 50 369 545 633 579 889 1352 804 1258 2124
24 50 331 482 550 529 811 1191 741 1164 1880
8/14C
28 50 369 545 633 579 889 1352 804 1258 2124
26 50 331 482 550 529 811 1191 741 1164 1880
24 50 293 411 468 478 729 1030 676 1070 1633
10/15C
28 50 349 503 585 554 839 1248 775 1199 1960
26 50 310 436 502 502 758 1087 708 1104 1714
24 50 270 367 418 448 674 922 638 1003 1463
12/16C
28 50 328 462 540 529 789 1148 744 1139 1801
26 50 288 394 455 473 706 984 672 1040 1552
24 50 246 324 369 416 618 816 598 933 1296
Heat output t1 C Heat outputs are stated in Watts. Heat outputs were measured in accordance with the 442/ DIN 470 standard.
75/65C
15 1879 2314 2644 4143 5102 5830 5209 6624 7568
20 1709 2105 2406 3768 4642 5305 4753 6044 6905
70/55C
15 1623 1999 2286 3579 4408 5041 4523 5754 6574
20 1453 1791 2048 3204 3949 4516 4061 5165 5900
55/45C
15 1198 1476 1687 2642 3255 3720 3366 4280 4890
20 1029 1267 1448 2269 2794 3193 2899 3687 4212
50/40C
15 1029 1267 1448 2269 2794 3193 2899 3687 4212
20 857 1056 1209 1890 2328 2666 2431 3088 3528
Schematic view
Standard supply
and optional specification
are identical with those of PKVT - see Page 14.
Cover grids see Page 20
t Correction factor for variant temperature
difference of elements
Temperature index m = 0.94
t (K) 20 22 24 26 28 30 32
kt 0,41 0,442 0,482 0,523 0,562 0,602 0,641
t (K) 34 36 38 40 42 44 46
kt 0,681 0,721 0,761 0,8 0,841 0,881 0,92
t (K) 48 50 52 54 56 58 60
kt 0,96 1,000 1,039 1,078 1,119 1,159 1,199
Pressure losses see Page 60
* If the convector tub is all made of steel, the transformer is not installed inside the tub but supplied separately in a mounting box see Mounting Instructions.
Drain outlet 12 mm
Stainless tub for trapping the condensate
Fan top filter
230 V/12V* transformer including
connecting cable
28
1
3
Width cm 28
Depth cm 13
Lengths cm 120 200 300
Noise level (acoustic pressure in 1-m distance from the source) dB (A) 24 33 37 30 37 40 32 39 42

17
floor-mounted convectors with fan Licon PKVTi TWIN
depth 13 cm
width 34 cm
lengths 120, 200, 300 cm
heat outputs max. 6742 W
cooling outputs max. 1186 W
maximum working pressure 1,2 MPa
maximum working temperature 110C
connecting threat internal G
case design steel, stainless steel 1.4400
service voltage of fans max.12V AC
Specification
PKVTi / TWIN another variant of floor-mounted convector with aftercooling effect. Four-tube exchanger serves both for heat-
ing and cooling
of room. The convector is also suitable for attachment in a four-tube system with heating and cooling circuit, and therefore
change of heating medium to cooling medium need not be solved. For this purpose a brand new design of Al/Cu of exchanger is
used, which was ideally designed both for heating and aftercooling. In case of low construction depth the convector has there-
fore excellent thermal and cooling outputs, measured in HLK Stuttgart.
The tub of the convector is equipped with a unique system of tub-in-tub when a stainless piece is built in the existing steel tub
which serves for trapping and drainage of potential condensate.
The fans used are tangential fans with max. 12 V voltage, the regulating system is identical with that of the PKVT fan-coils al-
ready produced.
Use in interiors
18
floor-mounted convectors with fan Licon PKVTi TWIN
Table of cooling and heat outputs
Schematic view

Cooling output t1 C
Speed of rotation 1 2 3 1 2 3 1 2 3
Humidity% Cooling outputs are stated in Watts. Cooling outputs were measured in accordance with the EN 145187 standard.
6/12C
28 50 215 241 248 498 598 666 811 1016 1186
26 50 190 214 226 441 530 597 722 901 1051
24 50 164 187 204 384 463 529 632 787 924
8/14C
28 50 190 214 226 441 530 597 722 901 1051
26 50 164 187 204 384 463 529 632 787 924
24 50 139 160 182 328 397 464 542 674 802
10/15C
28 50 173 199 173 404 493 567 663 837 993
26 50 148 171 148 348 424 497 573 721 862
24 50 122 144 122 291 357 430 483 606 738
12/16C
28 50 157 184 209 369 456 538 607 774 935
26 50 131 156 183 312 386 465 517 656 799
24 50 106 128 158 255 317 394 427 538 671
Heat output t1 C Heat outputs are stated in Watts. Heat outputs were measured in accordance with the 442/ DIN 470 standard.
75/65C
15 1506 1777 1866 3642 4305 4507 6105 7215 7555
20 1325 1568 1665 3204 3799 4022 5370 6368 6742
70/55C
15 1179 1397 1492 2850 3385 3605 4776 5674 6043
20 1015 1208 1307 2454 2926 3157 4112 4904 5292
55/45C
15 820 982 1087 1983 2380 2627 3323 3990 4403
20 666 803 905 1611 1945 2185 2701 3260 3663
50/40C
15 666 803 905 1611 1945 2185 2701 3260 3663
20 521 632 728 1261 1531 1758 2113 2567 2946
W
!
Heat output without fan is 231W/bm at 75/65/20C. Cooling output at other cooling drift than the above stated contact the manufacturer for information.
CATALOGUE code: PKVTi length (in cm), frame profile (U,F), shade of frame [S-silver, Z-gold, B-bronze]; rustless tub design (stainless).
Example: PKVTi 120 UZ = convector with PKVTi fan with steel tub, of 120 cm length, provided with a U-profile frame in gold.
If specification of decorative frame and the tub material design will be missing in the order, it will be made of steel plate and fitted with silver frame of U-shape.
t Correction factor for variant temperature
difference of elements
Temperature index m = 1.147
t (K) 20 22 24 26 28 30 32
kt 0,35 0,39 0,431 0,472 0,514 0,556 0,599
t (K) 34 36 38 40 42 44 46
kt 0,642 0,686 0,729 0,774 0,818 0,863 0,908
t (K) 48 50 52 54 56 58 60
kt 0,954 1,000 1,046 1,093 1,138 1,185 1,232
Pressure losses see Page 60
* If the convector tub is all made of steel, the transformer is not installed inside the tub but supplied separately in a mounting box see Mounting Instructions.
34
Drain outlet 12 mm
Stainless tub for trapping the condensate
Fan top filter
230 V/12V* transformer
including connecting cable
1
3
Width cm 34
Depth cm 13
Lengths cm 120 200 300
Noise level (acoustic pressure in 1-m distance from the source) dB (A) 24 34 41 27 37 41 27 39 41

Standard supply
and optional specification
are identical with those of PKVT - see Page 14.
Cover grids see Page 20
R A D I A T O R S F O R L I F E
19 19
Floor-mounted
convector cover grids
Licon PK, PKVT, PKVTi a PKVTi TWIN
The Licon PM floor-mounted cover grids are supplemental to the Licon PK, PKVT, PKVTi and PKVTi TWIN floor-mounted con-
vectors or may be, if reasonable, used for covering a shaft with an integrated Licon OR exchanger. Your interior can be nicely
complemented by selection of various types of materials or suitable colour shades of lamellas. The design of the grids enable
their easy uncover (they are scrollable), for instance due to cleaning the convector exchanger and, at the same time, guarantees
firmness when the device is transported.
Beech, natural Oak, natural Hornbeam, natural Mahogany, natural
Wooden grids
Grid profiles
Aluminium profile
AL frame profiles
Stainless profile Wooden profile F frame U frame
Grid design variants
Aluminium grids Stainless grid
Silver Bronze Gold Stainless
Note:
Standard design PK, PKVT and PKVTi contains silver U profile. If different type of frame is ordered, the new one will be attached
to the delivery. The shades of the frames are identical as those of aluminium grids. Wooden grids are supplied in natural design,
without surface treatment.
Correction factor of flow grid area
% of flow surface (area) means flow area of exchanger (width x length of heating element) minus flow area of expiratory grid
in percents.
% of flow area > 0,75 0,60 0,50 0,40 0,30
Correction factor 1,00 0,95 0,90 0,85 0,60
Permeability 66% Permeability 66% Permeability 60%
20
cover grids Licon PM
21
kryc mky Licon PK, PKVT
Design shapes and accessories
Licon design
R A D I A T O R S F O R L I F E
Use in interiors
22
design shapes and accessories Licon design shapes
Depths for corner (angular) max. 19 cm
Arc design for PK and PKVT all types with depth to 19 cm, individual evaluation
of capacity has to be elaborated, for PK and PKVTi
Design of tub stainless steel 1.4400
Grid design aluminium, wood
Specification
Note:
We reserve the right to evaluate the possibility of execution before acceptance of the order. Corner pieces must be ordered
simultaneously with following convectors. Arcs and corner parts are supplied including the cover grid ordered. Heat outputs
of the arc design cannot be guaranteed anyhow, the manufacturer will execute an expert estimation of the heat output upon
request. Heat exchanger cannot be installed in a corner part, therefore it does not heat.
Corner design Arc design
Note:
To order the corner design, the angle (a), lengths (L1 and L2) and the entire width (A) have to be specified, which must conform
to the floor-mounted convector tub widths produced. As concerns the arc design, the angle (a) and the inner or outer radius
(R - inner, R - outer) must be specified, as well as the entire width (A) which must conform to the floor-mounted convector tub
widths produced.
R

i
n
n
e
r
R

o
u
t
e
r
23
design shapes and accessories Licon design shapes
Special accessories
ELECTROBOX
Electrobox serves as a plug&socket box for installation of instruments in all types of administration buildings, hotels, schools,
shops, etc. Electrobox solves distribution from the floor directly to the service points. It is designed to be built in between con-
vectors e.g. in a long glazed wall. It looks discreet and very purposeful at the same time. It is universal for mounting in any type
of floor (concrete, double, etc.). It can be used for PK and PKVT convectors in 11 cm depth and 28 cm width.
Electrobox is fitted with a plaster eight-module electric distribution box with a lid. The inner equipment of the electrobox (sock-
ets, networks, etc.) is not supplied by the LICON manufacturer. Please contact directly the website of the socket box manufac-
turer: http://www.schneider-electric.cz/produkty-a-sluzby/rozvody/nizke-napeti/instalacni-system-optiline.html , type Altira.
24 24
Connection
Connection of heat-carrying medium
PK - ORJ2
window - wall
PK - ORJ3
window - wall
PKVT - ORJ2
window - wall
PKVT - ORJ3
window - wall

Connection of tubs
1. Series connection of PK / PKVT tubs (2 tubs)
1.1. - Right
window - wall
CON-R CON-L
1.2. - Left
window - wall
CON-L CON-R
1.3. - Inner
window - wall
CON-R CON-R
1.4. Outer
window - wall
CON-L CON-L
2. Connection of PK / PKVT to corner piece or arc
2.1. -- Right
window - wall
CON-L
2.2. - Left
window - wall
CON-R
2.3. - Inner
window - wall
CON-R
2.4. - Outer
window - wall
CON-L
w
i
n
d
o
w

-

w
a
l
l






C
O
N
-
R
w
i
n
d
o
w

-

w
a
l
l






C
O
N
-
L
w
i
n
d
o
w

-

w
a
l
l






C
O
N
-
R


w
i
n
d
o
w

-

w
a
l
l






C
O
N
-
L


3. Series connection of PK / PKVT (3 and more tubs)
3.1.- Right
window - wall
CON-L CON-L/R CON-L
3.2. - Left
window - wall
CON-L CON-L/R CON-R
4. Series connection of PKTi / PKVTi TWIN (2 and 3 tubs)
4.1.- Right (standard)
window - wall
CON-R CON-L
window - wall
CON-R CON-L/R CON-L
- supply of heat-carrying medium
CON L - lowering of face on the opposite side of the supply
CON R - lowering of face on the side of the supply
CON L/R - lowering of both faces (fronts)
Floor - mounted
R A D I A T O R S
25
26
podlahov konvektory
Bench-mounted convectors
Licon OL
R A D I A T O R S F O R L I F E
27
28
bench-mounted convectors Licon OL
height of bench element 9, 15, 30, 45, 60 cm
widths 18, 24 cm
lengths 80, 100, 120, 140, 160, 180, 200,
220, 240, 260, 280, 300 cm
outputs from 473 to 4733 W
maximum working pressure 1,2 MPa
maximum working temperature 110 C
maximum working temperature 40 C
connecting threat internal G
connection method bottom recommended, side
Specification
Heating benches Licon OL will find their use at places with lowered parapet, at glazed areas, et. A rich spectrum of designs and
outputs allow their installation in any type of areas without disturbing the compactness of the interior. Another variant of Licon
OL is a Licon OL/D heating bench which bears static load and therefore is suitable for instance for sitting, for instance at pools or
on corridors.
Note:
Production of exchanger with new connection method will begin on January 1, 2009 (including supplier of a valve set, head set, etc.).
Use in interiors
29
bench-mounted convectors Licon OL
L
150 - 300 150 - 300
Element sections
ka 16 cm
www.licon.cz
Width 18 cm
Height 9 cm
Width 24 cm
Height 9 cm
Width 18 cm
Height 15 cm
Width 25 cm
Height 15 cm
S
i
d
e

c
o
n
n
e
c
t
i
o
n
B
o
t
t
o
m

c
o
n
n
e
c
t
i
o
n
Note:
Height without stands. Bench-mounted convectors OL are produced for universal side/bottom connection. The connection can
be executed directly in mounting on site. For bottom connection the manufacturer recommends to use a set which contains
thermostatic valve and thermostatic head LICON/Danfoss with an extension adaptor. If another type of valve is used, connect-
ing spacing of 50 mm between the input and output will not be achieved - it applies if the height is 15 cm and more, and if the
height is 9 cm, the spacing corresponds with the above sketch (the dimensions are stated in mm).
Sketch of bottom connection
of 18 and 24 cm widths and 60 cm height
Sketch of bottom connection
of 18 and 24 cm widths and 9 cm height
Sketch of bottom connection
of 18 and 24 cm widths and 9 cm height
Sketches of OL with stands on clean floor (dimensions in mm)
3
0
9
0
60
3
0
90
9
0
90 60
180
1
5
0
6
0
3
0
90
1
5
0
6
0
3
0
240
120
L
150 - 300 150 - 300
L
150 - 300 150 - 300
50
L
150 - 300 150 - 300
Note:
Bench-mounted convectors OL are as standard supplied with
stands on clean floor. Another possibility of fastening to the
structure of a building is use of stands on rough surface or by
brackets on wall (see illustration on Page 57).
1
0
0
1
0
0
1
0
0
1
0
0
Note:
Detailed dimension sketches including calculation of
distances between the stands - see Page 57.
Sketch of bottom connection of 18 and 24 cm widths
and 15, 30, 45 and 60 cm eights
30
bench-mounted convectors Licon OL
Table of heat outputs
Heat outputs (W) at tw1/tw2/ti = at 85/75/20C (t=60) and at 75/65/20C (t=50) according to CSN EN 442
Standard order contains
steel plating, varnished in RAL 9010 shade - white
heat exchanger for universal connection (side or bottom)
with low water content and uniquely shaped lamellas for
higher heat output, exchanger fitted with air-relief valve G
1/4 or G 1/2
stand on clean floor, see sketch on Page 57
mounting instructions of element
The set is wrapped in a cardboard cover.
Heights of Licon OL benches
Optional accessories
a set which contains thermostatic valve and thermostat-
ic head LICON/Danfoss with an extension adaptor, see
Page 61
stands on rough floor or wall suspension, see sketch on
Page 57
if more than 20 pieces is ordered, another colour shade
of design can be selected (the change has to be consulted
with the manufacturer).
Licon OL PLAN
The PLAN design variant with an absolutely straight front
board see the Licon OK elements.
TIPE:
The LICON OL/D heating elements can be equipped with a
calorimeter for measuring heat consumption, see Page 62 for
more information.
CATALOGUE CODE:
OL length/height/width (in cm) / design PLAN [PLAN]
Example: OL 160/30/26 = convector bench OL, length 160 cm, height 30 cm, width 26 cm
The standard design contains a stand on clean floor, connection to heating system (side bottom), need not be specified. If mounted on wall or rough floor.
W
!
Width
(cm
t
Length L (cm)
80 100 120 140 160 180 200 220 240 260 280 300
H
e
i
g
h
t

9
18
t 60 606 764 923 1083 1242 1401 1561 1720 1879 2038 2197 2356
t 50 473 596 720 845 969 1093 1217 1342 1466 1590 1714 1838
24
t 60 1084 1405 1726 2049 2371 2692 3014 3336 3658 3980 4302 4624
t 50 845 1096 1347 1598 1849 2100 2351 2603 2853 3104 3356 3607
H
e
i
g
h
t

1
5
18
t 60 755 952 1150 1349 1547 1746 1944 2143 2341 2538 2737 2935
t 50 589 743 897 1052 1207 1362 1517 1671 1826 1980 2135 2290
24
t 60 1417 1837 2257 2678 3099 3519 3940 4361 4781 5202 5624 6045
t 50 1105 1433 1760 2089 2417 2745 3074 3402 3730 4058 4387 4715
H
e
i
g
h
t

3
0
18
t 60 1001 1263 1526 1790 2053 2316 2580
t 50 781 985 1191 1396 1601 1807 2012
24
t 60 1757 2278 2798 3321 3843 4364 4886
t 50 1370 1777 2183 2590 2998 3404 3811
H
e
i
g
h
t

4
5
18
t 60 1056 1333 1610 1888 2166 2444 2722
t 50 824 1040 1256 1473 1690 1906 2123
24
t 60 1984 2572 3160 3749 4339 4927 5516
t 50 1547 2006 2465 2924 3384 3843 4303
H
e
i
g
h
t

6
0
18
t 60 1207 1523 1841 2158 2476 2793 3111
t 50 942 1188 1436 1683 1931 2179 2426
24
t 60 2182 2829 3476 4124 4773 5419 6068
t 50 1702 2207 2711 3217 3723 4227 4733
t Correction factor for variant temperature
difference of elements Licon OL
Teplotn exponent m = 1,364
t (K) 20 22 24 26 28 30 32
kt 0,287 0,326 0,367 0,410 0,453 0,498 0,544
t (K) 34 36 38 40 42 44 46
kt 0,591 0,639 0,688 0,737 0,788 0,839 0,892
t (K) 48 50 52 54 56 58 60
kt 0,946 1,000 1,055 1,111 1,167 1,224 1,282
Pressure losses and valve Kv
values see Page 60
9
0
1
5
0
3
0
0
4
5
0
6
0
0
Bench-mounted convectors
Licon OL/D
R A D I A T O R S F O R L I F E
31
32
bench-mounted convectors Licon OL/D
Use in interiors
height of bench element 29 cm
widths 26 cm
lengths 100, 120, 140, 160, 180, 200 cm
outputs from 1369 to 2902 W
maximum working pressure 1,2 MPa
maximum working temperature 110 C
maximum working temperature 40 C
connecting threat internal G
connection method bottom recommended, side
cover plate design Stone imitation (Teraco)
Timber beech, oak
plating design Stainless steel, mate, standard 1.4404
Specification
The Licon OL/D convector was designed for areas intended for relax and rest. Te bench is provided with a cover plate (attention
the plate must be ordered separately) which can bear static load and is suitable even for sitting. After seating on convector the
plates are fixed to the structure of the convector. The Licon OL/D convector can be placed e.g. in halls or winter gardens.
For installation at pools we recommend to order an all-steel design, the so-called pool design, painted with standard white
paint, according to RAL 9010.
Note:
Production of exchanger with new connection method will begin on January 1, 2009 (including supplier of a valve set, head set, etc.).
33
bench-mounted convectors Licon OL/D
Element sections
The dimensions in the schemes are in mm.
Side connection
Bottom connection
www.licon.cz
300
3
2
0
6
0
1
1
0
300
3
2
0
8
2
50
34
bench-mounted convectors Licon OL/D
Table of heat outputs
Heat outputs (W) at tw1/tw2/ti = at 85/75/20C (t=60) and at 75/65/20C (t=50) according to CSN EN 442
CATALOGUE CODE:
OL/D length in cm, or Plate for OL/D length (in cm) [Teraco, Beech, Oak]
Example: OL/D 160 = convector bench Licon OL/D , length 160 cm. Attention: The plate must be ordered separately!
The standard design allows connection to heating system (side bottom), need not be specified in the order..
W
!
Height
(v cm)
Width
(v cm)
t
Length L (cm)
100 120 140 160 180 200
32 26
t 60 1754 2148 2541 2935 3328 3720
t 50 1369 1675 1982 2289 2596 2902
Standard supply contains
steel plating, varnished in RAL 9010 shade - white
heat exchanger for universal connection (side or bottom)
with low water content and uniquely shaped lamellas for
higher heat output, exchanger is fitted with air-relief valve
G 1/4 or G 1/2
mounting instructions of element
The set is wrapped in a cardboard cover.
Optional accessories
a set which contains thermostatic valve and thermostat-
ic head LICON/Danfoss with an extension adaptor, see
Page 61
cover plates - imitation of Terace stone, timber beech,
oak
stainless-steel design, suitable in moist environment, e.g.
pools
if more than 20 pieces is ordered, another colour shade
of design can be selected (the change has to be consulted
with the manufacturer).
TIPE:
The LICON OL/D heating elements can be equipped with a
calorimeter for measuring heat consumption, see Page 62 for
more information.
TERACO
Note:
The plates are made of natural materials, and therefore small deviations in colour design cannot be eliminated. The plates are
blocked against movement.
t Correction factor for variant temperature
difference of elements Licon OL
Temperature index m = 1.364
t (K) 20 22 24 26 28 30 32
kt 0,287 0,326 0,367 0,410 0,453 0,498 0,544
t (K) 34 36 38 40 42 44 46
kt 0,591 0,639 0,688 0,737 0,788 0,839 0,892
t (K) 48 50 52 54 56 58 60
kt 0,946 1,000 1,055 1,111 1,167 1,224 1,282
Pressure losses and valve Kv
values see Page 60
Cover plate design variants
OAK BEECH
Wall - mounted
R A D I A T O R S
Wall-mounted elements
Licon Ceramic
R A D I A T O R S F O R L I F E
37
38
wall-mounted elements
depth 16 cm
width 54 cm
lengths 77, 97, 117 cm
heat outputs max. 3055 W
maximum working pressure 1,2 MPa
maximum working temperature 110C
connecting threat vnitn G 1/2
service voltage of fans max. 14V DC/has to be reachable
for connection 230V
noise level acoustic pressure
in 1-m distance from the ourc
max. common operation 21dB,
Turbo max. 31dB
Specification
LICON OK/C CERAMIC - is an intelligent heating element, an absolute novelty in the world of heating elements. First radiator
with jacketing manufactured of ceramic tiles. It is a very original heating element, designed for areas where original, unconven-
tional design is demanded. CERAMIC is not an absolute novelty from outside only, but inside there is a sophisticated system of
heat transfer to the room. Beginning with new arrangement of Al/C of the exchanger and, first of all, the Low-noise regulating
systm of axial fans in permanent run 21.4 dB.
The desired temperature in the room is set by the user directly on the heating element. If multiple elements are controlled in
one room, one is designated as master which controls the others, or the entire system can be connected to a programmable
thermostat Siemens REA 23M. For short-term power increase, CERAMIC is equipped with Turbo function when for about 10
minutes the fan rotation speed increases by which the output increases by approx. 20%. The system evaluates temperature of
heating water in the room, and according to that an ideal output curve is selected.
Use in interiors
Licon OK/C
39
wall-mounted elements
Schematic view
OK/C Enamels
ENAMEL
No.1
(ochre)
ENAMEL
No.2
(blue)
ENAMEL
No.3
(beige)
ENAMEL
No.4
(green)
ENAMEL
No.5
(ivory)
Licon OK/C
Low-noise axial fans
Control display
Valve with
servodrive
Heat exchanger
Control electronics
50
Thermal sensor
40
wall-mounted elements
Specification Licon OK/C Ceramic
Height cm 54
Depth cm 16
Length cm 77 97 117
Noise level acoustic pressure dB (A) 21,4 / 31,2 21,4 / 31,2 21,4 / 31,2
Heat output t1 C W W W
75/65/20C
Fan switched off 332 498 666
Permanent run 996 1494 1992
TURBO 1260 1890 2521
85/75/20C
Fan switched off 402 604 807
Permanent run 1207 1811 2414
TURBO 1527 2291 3055
Temperature index m = 1.056
t Correction factor for variant temperature
difference of Licon OL elements
Temperature index m = 1,056
t (K) 20 22 24 26 28 30 32
kt 0,380 0,420 0,461 0,501 0,541 0,583 0,624
t (K) 34 36 38 40 42 44 46
kt 0,665 0,707 0,748 0,790 0,832 0,874 0,916
t (K) 48 50 52 54 56 58 60
kt 0,958 1,000 1,042 1,085 1,127 1,170 1,212
Pressure losses and Kv values
of valve see Page 60
W
!
Standard supply contains
jacketing of ceramic tiles, Low noise axial fans, complete
control electronics including thermostatic valve with
servodrive, thermal sensors
heat exchanger with low water content and uniquely
shaped lamellas for higher heat output. The exchanger is
fitted with an air-outlet valve G 1/4 or G 1/2
accessories for suspension of the element on the wall
mounting instructions of element
The set is wrapped in a cardboard cover.
Optional accessories
the colour of ceramic jacketing enamel
Noise level first value applies for permanent run, second is measured in turbo mode.
The acoustic pressure level is measured in 1-m distance from the source.
CATALOGUE CODE:
OK/D length in cm and enamel no.
Example: OK/C 97/1 = heating element of 97 cm length, type of enamel 1.
OK/C side-view
Licon OK/C
160
5
4
0
68
1
0
0
The dimensions in the schemes are in mm.
41
wall-mounted elements
Wall-mounted elements
Licon OK
R A D I A T O R S F O R L I F E
42
wall-mounted elements
depths 9, 15 cm
widths 45, 60 cm
lengths 40, 60, 80, 100, 120, 140, 160, 180, 200 cm
outputs from 266 to 2735 W
maximum working pressure 1,2 MPa
maximum working temperature 110 C
maximum working temperature 40 C
connecting threat internal G
connection method side, bottom
Specification
Wall-mounted convectors Licon OK are common wall-mounted radiators with a long history used in households and also in com-
mercial premises. Their modern design, easy mounting and economic operation are the reasons for their popularity with our
customers. Considering the unique design of the heat exchanger used, they achieve higher outputs even at small dimensions of
the element. The big advantage of wall-mounted OK convectors is very low surface temperature of 40 C max, and non-existing
heat radiation in the wall.
Use in interiors
Licon OK
43
wall-mounted elements
Element sections
The dimensions in the schemes are in mm.
Side connection, depth 9 cm
Side connection, depth 15 cm
Bottom connection, depth 9 cm
Bottom connection, depth 15 cm
www.licon.cz
90
H
2
0
0
4
0
45
L
90
H
45
145
H
3
0
0
90
5
8
L
145
H
90
Licon OK
L
35
50
6
5
L
35
50
1
5
6
5
44
wall-mounted elements
Table of heat outputs
Heat outputs (W) at tw1/tw2/ti = at 85/75/20C (t=60) and at 75/65/20C (t=50) according to SN EN 442
Standard supply contains
plating of steel plat, painteed in RAL 9010 shade - white
heat Exchange with low water content and uniquely
shaped lamellas for higher heat output with bottom or
side connection variant (according to the catalogue code
stated in the order), the Exchange is fitted with a vmnk
je osazen n air-outlet valve 1/4 or G 1/2
back of convector
set for mounting the element on the wall, containing wall
plugs, screws and suspension brackets
mounting instructions of elements
The set is wrapped in a cardboard cover.
Optional accessories
If more Licon OK elements is ordered (20 pieces and more),
another RAL colour shade can be selected (the change has to
be consulted with the trade department of company Licon
Heat, s. r. o.).
Design
variant
Licon OK PLAN
CATALOGUE CODE::
OK length/height/depth (in cm) of connection [B-side, S-bottom], connection side [L-left, P-right] in PLAN [PLAN] design
Example: OK 140/60/9 SP = convector body OK, length 140 cm, height 60 cm, depth 9 cm, bottom connection on the right side.
W
!
Depth
(cm)
t
Length L (cm)
40 60 80 100 120 140 160 180 200
H
e
i
g
h
t

4
5
9
t 60 345 518 690 861 1035 1208 1380 1553 1725
t 50 266 400 533 665 799 933 1065 1199 1332
15
t 60 600 901 1204 1504 1807 2107 2409 2710 3015
t 50 463 696 930 1162 1396 1627 1860 2093 2328
H
e
i
g
h
t

6
0
9
t 60 397 595 793 991 1190 1388 1579 1778 1976
t 50 306 459 612 766 919 1072 1220 1373 1526
15
t 60 707 1061 1416 1768 2124 2479 2833 3187 3542
t 50 546 820 1093 1367 1640 1914 2188 2461 2735
Correction factor for variant temperature difference t of Licon OK elements
See Page 62 for formula and example of conversion to variant temperature difference.
t (K) 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50
kt 0,272 0,311 0,352 0,395 0,438 0,484 0,530 0,578 0,628 0,677 0,728 0,780 0,834 0,888 0,944 1,000
t (K) 52 54 56 58 60
kt 1,057 1,116 1,175 1,235 1,295
Temperature index m = 1.422
PLAN with absolutely straight front plate. It is supplied for
elements Licon OK and Licon OL.
TIPE:
The LICON OK heating elements can be equipped with a
calorimeter for measuring the heat consumption - see more
information on Page 62.
Use in interiors
Licon OK
Heating Registers
Licon OR
R A D I A T O R S F O R L I F E
45
46
heating Registers Licon OR
Use in interiors
widths 6, 12, 18 cm
widths 5, 11 cm
lengths 80 to 300 cm
maximum working pressure 1,2 MPa
maximum working temperature 110 C
connecting threat internal G
outputs
according to the exchange shielding
height, see Table of outputs and correction
factors for different height of the cases
Specification
The heart of all Licon convectors is right the heating register Licon OR. However, its use is much wider. It is suitable for individual
installation, mainly at places where compactness of interior is required in terms of materials used. If certain conditions are kept,
the Licon OR heating registers can be used to cover almost any material for their smooth composition in the space.
Note:
Production of exchanger with new connection method will begin on January 1, 2009 (including supplier of a valve set, head set, etc.).
47
heating Registers Licon OR
Element sections
www.licon.cz
OR-J1 OR-J2
OR-D3
OR-J3
The dimensions
in the schemes
are in mm.
OR-D2
HOT AIR OUTLET
(the grid must have sufficient
flow, see Table)
COLD AIR INLET
(at least 80% of flow
HR area)
FLOOR
REGISTER
WALL
S
H
U
T
T
E
R
Correct installation
The heat output of the register depends on several
main conditions: Effective height of the shutter,
tightness of design of this shutter (case), inlet of
heated air and flow area of expiratory grid (see
Fig.). Generally applies that the higher the shutter
is, the higher is the heat output. The convector case
and adjacent building structure must be resistant to
calculation temperatures of heat-carrying substance.
See next page for correction height factor of the
shutter;
See the cover grid section on Page 21 for correction
factor per flow area of expiratory grid.
Total length of register
60
5
0
120
5
0
180
5
0
120
1
1
0
180
6
0
60
90 60
6
0
1
0
1
1
0
30
1
0
48
heating Registers Licon OR
The heat outputs stated apply at the height of 10 cm above the floor level, the height of the shutter is 12 cm from the bottom
edge of lamellas.
Table of heat outputs
Heat outputs (W) at tw1/tw2/ti = at 85/75/20 C (t=60) and at 75/65/20 C (t=50) according to CSN EN 442
Type of
HR
t
Length L (cm)
80 100 120 140 160 180 200 220 240 260 280 300
OR-J1
t 60 373 466 559 652 746 838 931 1025 1118 1211 1304 1397
t 50 286 357 428 499 571 642 713 785 856 928 999 1070
OR-J2
t 60 678 847 1017 1186 1356 1524 1693 1864 2033 2202 2372 2540
t 50 519 649 778 908 1038 1167 1296 1427 1557 1686 1816 1945
OR-J3
t 60 1060 1326 1591 1856 2121 2386 2650 2916 3181 3446 3711 3975
t 50 813 1017 1220 1423 1626 1830 2032 2236 2439 2642 2846 3048
OR-D2
t 60 848 1059 1271 1482 1695 1905 2116 2330 2541 2753 2965 3175
t 50 649 811 973 1135 1298 1459 1620 1784 1946 2108 2270 2431
OR-D3
t 60 1325 1657 1989 2320 2651 2982 3312 3645 3976 4307 4638 4968
t 50 1016 1271 1525 1779 2033 2287 2540 2795 3049 3303 3557 3810
W
!
CATALOGUE CODE:
Type of HR/ length ( in cm), for instance OR-J3-200 = single-line, three-tube heating register Licon OR-J3, length 200 cm W
!
Correction factor for variant temperature difference t of Licon OR elements
See Page 62 for the formula and example of conversion to variant temperature difference.
t (K) 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50
kt 0,262 0,302 0,342 0,385 0,429 0,474 0,521 0,567 0,619 0,670 0,722 0,775 0,830 0,886 0,942 1,000
t (K) 52 54 56 58 60
kt 1,060 1,119 1,180 1,242 1,305
Temperature index m =1.46
Correction factor for different height of case H
The height of the case H (m) is considered from the bottom lamellas of the exchanger.
Example:
Conversion of the OR-J3/180 heat exchanger output to the output in the case of 0.45 m height.
Q = 1830 x 1.416 = 2591 W
H (m) 0,125 0,150 0,200 0,250 0,300 0,350 0,400 0,450 0,500 0,550 0,600
kh 1,000 1,051 1,136 1,207 1,268 1,322 1,371 1,416 1,457 1,495 1,531
Standard supply contains
heat exchanger with low water content and uniquely
shaped lamellas for higher heat output. The exchanger is
fitted with an air-outlet valve G 1/4 or G 1/2.
mounting instructions of element
The assembly is wrapped in a solid PVC foil with edge
protectors.
Optional accessories
black paint of the exchanger
little stands for fitting the register, see Page 58
Pressure losses see Page 60
Technical information
for mounting Licon convectors
R A D I A T O R S F O R L I F E
50
information for mounting convectors Licon
Mounting of building part convector
Several general principles have to be fulfilled to ensure correct function of convector:
Correctly installed element has the exchanger located further from the window.
To interconnect the exchanger and the distributing main, standardly supplied stainless hoses with stainless coating have
to be used (of not recommended otherwise) which always form a part of the delivery. They enable better access under the
heating register, without the necessity of dismantle it from the heating system, e.g. during cleaning.
We recommend to execute the supply of the heat-carrying medium into the heating register always in a tube which is further
from the fan. In case of 42 cm the OR-J3 heating register is used where the heat-carrying medium passes two tubes there and
one back.
The PKVTi TWIN exchanger is a double-tube exchanger where one circuit serves for connecting the heating circuit and the
other for connecting on the cooling circuit. Selection of the heating circuit in relation to the distance from the fan is not
important both parts of the exchanger are blown same.
Correctly installed convector lies horizontally, and the bottom margins of the convector tub are not demolished or bent in
order to ensure correct function of the working grid, as well as the possibility of replacing the exchanger.
Correctly installed convector has decorative frame at the level of floor covering within the tolerance of +2mm.
To prevent contamination from inside the convector, we recommend to leave the cover plate during concrete pouring.
Warning: The plate is not trafficable!!
Floor - mounted convector must be firmly embedded in concrete. Set screws serve only for horizontal levelling of the
convector tub. The convector must not stand on these screws without being embedded in concrete. In terms of its design, the
convector is not suitable for transfer a load by the bottom.
During the concrete pouring, the convector must be fixed to the floor using anchoring bolts which prevent the convector
from vertical shifting in subsequent concrete pouring. During concrete pouring, the convector can be loaded vertically.
During concrete pouring, the convector must be strutted to prevent the tub from deformation.
In case of convector with fan, we recommend to execute fixation and acoustic insulation by pouring the convector along its
side and also under its bottom with concrete, or at least fill the free space with a suitable material. Ideal sound absorption is
achieved by direct embedding the convector in concrete.
Increased noise level might occur when installing the convector with fan in a free space of the convector.
All convectors with stainless tub and all types of PKVTi and PKVTi Twin have, as standard, an in-built drain of condensate or
water. During mounting do not forget to attach the tube on the bottom of the convector with secured drift for waste water
or condensate drain. We recommend the waste pipe to be provided with a seal-pipe to prevent odour.
Mounting of convector Licon PK, PKVT, PKVTi and PKVTi TWIN
Section of correct convector installation
Note: not included in the delivery.
Jointing material
(silicone)
U frame Trafficable grid F frame Clean floor
Concrete filler
Thermal insulation Set screw Exchanger Fan Anchor Rough floor
51
information for mounting convectors Licon
= do 20 %
Window Dividing partition
Insulation
Register
Adjusting screw
Insulation
Insulation
Anchor
Grid rib
Decorative
frame
Clean floor
Plating
Rough floor
Insulation
Dilatation joint
= 70100 %
Q of the window
Q of the convector
LOCATION OF EXCHANGER ON THE SIDE
OF THE ROOM
Down current of cool air enters the convector case.
Upward flow of heated air then supports natural air
circulation in the room and thus creates a shutter in
front of the window area. This arrangement is suitable
where there is a sole source of heating and where the
share of heat losses of window in the total heat loss of
the room is approximately 70 - 100 %
LOCATION OF EXCHANGER ON THE SIDE
OF THE WINDOW
This location is suitable where heat losses on the side
of the room prevail, only with small share of window
(most 20%). The distance between the convector and
the window must be selected as short as possible.
Mounting location
Recommended location of heat exchanger for Licon PK models - 30 a 45 cm depths
for elements of depth 7.5 cm A = 40 mm
for elements of depth 9 cm A = 50 mm
for elements of depth 11 cm A = 60 mm
for elements of depth 15 a 19 cm B = 50 mm
for elements of depth 30 cm B = 120 mm
for elements of depth 45 cm B = 290 mm
Connecting dimensions
Depth 7.5, 9 and 11 cm Depth 15, 19, 30 and 45 cm
www.licon.cz
Q of the window
Q of the convector
52
information for mounting convectors Licon
Mounting of convector electric regulation PKVT, PKVTi and PKVTi TWIN
(further identified as fan-coils)
Regulation is executed by means of changing the rotation speed of the fan (different amount of air passes the heat exchanger
= change of heat output). The system controls as follows: if the air temperature in the room drops below the level set on the
thermostat, the thermostat switches on the fans and thus multiplies the heat power of the convectors. We supply two variants
of regulation (control) basic and automatic (continuous).
Description of basic regulation
This regulation can serve both for heating and for cooling. It is a convenient compromise between the price and the utility
value. The revolutions of the fan and required room temperature must be set manually. The easiest variant is use of associated
controller Siemens RAB 10 which integrates all these functions, including a switch between heating and cooling. To increase the
comfort of heating and operation, digital weakly programmable thermostat Siemens RDE 10.1 can be used instead of manual
thermostat. Thermostat of this type can control operation of the boiler and thus the entire heating system. If the room is heated,
the thermostat switches off the boiler and, at the same time, the fans switch off, too. in case of variants with simple thermostat,
switching the fans off is linked to the other heating system. In addition, auto-transformer AT (max. load 600 VA) and transformer
230/12 V must be integrated in the electric circuit of this regulation which is mounted in the element of the standard PKVT de-
sign (in case of stainless design of the convector tub, the transformer is not a part of the element, and its size must be specified
according to the procedure specified on Page 56). Maximum voltage of the fans is 12 V.
The AT auto-transformer (AT transformer 230/12 V for stainless element design) is mounted in its own mounting box which is
designed for installation in the wall. The dimension of the mounting box is 205 x 255 x 70 mm (W x H x D).
Electric wiring diagram of manual thermostat and Siemens RAB 10 rpm switch
Electric wiring diagram of weakly programmable thermostat Siemens RDE 10.1, rpm switch Siemens RAB 90
Auto-transformer
Control of boiler
Auto-transformer
53
information for mounting convectors Licon
Description of automatic regulation
This regulation only works as automatic with continuous control of fan rpm, depending on the room temperature and tempera-
ture requirement by setting on the thermostat. Depending on the temperature deviation (between the set and actual tempera-
ture), the RM 01 control module changes automatically and fluently the input voltage in the transformers and thus, at the same
time, changes the rpm of the fans. Automatic regulation can be only used for heating.
The entire system consists of RM 01 control module (and according to the need of the RoM 01 extension module) and program-
mable thermostat Siemens REV23M (automatic temperature setting for longer time interval - 1 week max.). The thermostat
communicates with the control module by means of the OpenTherm protocol. For instance, this communication allows more
continuous regulation of boiler output.
The RM 01 module is capable to regulate Licon PKVT elements to maximum input of 400 VA, if there is a demand for control
of higher number of heating elements, an extension module RoM 01 800 VA must be added in the system but not higher than
5 pieces of RoM 01 (= 4000 VA max).
Electric wiring scheme of automatic regulation connection
Modern production
Control
module (400VA)
RM 01
Extension module
(800VA)
RoM 01
regulator
Siemens
REA 23 M
Safe voltage
54
information for mounting convectors Licon
Control elements of basic regulation
SIEMENS RDE 10.1
SIEMENS RAB 10
SIEMENS RAB 90
- room thermostat with rpm switch
- geating and cooling switch
- manual switch of fan rpm
- voltage 24 to 250 V AC
- current 0.2 to 6 (2) A
- temperature setting range 8 to 30C
- coverage IP 30
- dimensions W x H x D - 96.4 x 113.1 x 42.8
- room thermostat with weakly programme
- heating and cooling switch
- voltage 3V DC (2 x 1.5 V - AAA alkaline batteries)
- temperature setting range 5 to 30C
- possibility of connecting a separated sensor, e.g. for applications in humid environ-
ment of IP 30 coverage
- for switching the fan rpm the RAB 90 rpm switch must be used
- dimensions W x H x D - 96 x 119 x 23
- simple fan rpm switch with three degrees (0-I-II-III)
- voltage 24 to 250 V AC
- current 6 (2) A at 250V
- coverage IP 30
- dimensions W x H x D - 96.4 x 99.6 x 42.8
- mounting box designed for installation in the wall
- contains auto-transformer
- or 230/12 V transformer
- (it is used for installation in humid areas)
- coverage IP 20
- dimensions W x H x D - 205 x 255 x 70
MOUNTING BOX
TOROID AUTO-TRANSFORMER
- max load 600 VA
- thermal fuse 130C
- dimensions - 0 150 x 48 mm
- coverage IP 00
- length of supply cables, max. 20 cm
- must be ordered separately,
- is not included in the delivery.
TOROID AUTO-TRANSFORMER
(120, 225 VA, 300 VA)
- thermal fuse 130C
- dimensions from 93 to 150 mm
height from 45 to 50 mm
- length of supply cables, max. 20 cm
- must be ordered separately, is not
included in the delivery. AUTO-TRANSFORMER
/ TRANSFORMER
TOROID TRANSFORMER 230/12 V
- mounted directly in PKVT/PKVTi
- thermal fuse 130C
- coverage IP 54
- length of supply cables, ca 5 m
TRANSFORMER
55
information for mounting convectors Licon
CONTROL MODULE
RM 01
EXTENSION
MODUL ROM 01
Automatic regulation elements
SIEMENS REA 23 M
TOROID TRANSFORMER 230/12 V
- mounted directly in PKVT/PKVTi
- thermal fuse 130C
- coverage IP 54
- length of supply cables, ca 5 m
- room thermostat with weakly programme
- communication with OpenTherm protocol
- easy control
- voltage 3V DC (2 x 1.5 V - AAA alkaline batteries)
- temperature setting range 5 to 29C
- possibility of remote control connection
- coverage IP 20
- dimensions W x H x D - 140 x 104.5 x 30
TRANSFORMER
- supply voltage: 230V AC, 50Hz
- output rating for fan: 1.7A (400VA)
- relay contact rating: 5A/250VAC or 5A/30VDC, resistive load, galvanic
separated 4kVAC
- electric coverage: IP00
- fuse: Tube fuse 5x20mm, T4A/1500A (recommended: Omega GT520240)
- protection: circuit-breaker max. 13 A (char. B)
- mounting: on DIN bar into distribution box or case, vertical position
- dimensions (W x H x D): 107 x 91 x 60mm
- weight: 360g
- service temperature 0 a 40C
- supply voltage: 230V AC, 50Hz
- output rating for fan: 3.5A (800VA)
- electric coverage: IP00
- fuse: Tube fuse 5x20mm, T5A/1500 (recommended: Omega GT520250)
- protection: circuit-breaker max. 13A (char. B)
- mounting: on DIN bar into distribution box or case, vertical position
- dimensions (W x H x D): 107 x 91 x 60mm
- weight: 320g
- service temperature: 0 to 40C
www.licon.cz
56
information for mounting convectors Licon
Example of input calculation for correct electric wiring
The electric input of Licon PKVT, PKVTi, and PKVTiTwin elements must be calculated correctly both for the basic and automatic
regulation. This total input must be known for correct selection of number of AT auto-transformers or extension RoM 01
modules.
The total input of elements is calculated as follows: by counting up inputs of all floor-mounted fan-coil convectors which will be
controlled through a single thermostat or RM 01 control module. The sum of their inputs will give the intensity of the input.
MODEL CALCULATION
We know the number of designed Licon PKVT elements. In the table of heat fan-coil outputs, in the Maximum Input column, we
can find input (VA) for relevant Licon PKVT element. By counting up we will get total quantity of the input (VA).
EXAMPLE OF SIMPLE REGULATION
We will compare the total calculated input (in our case it is 468 VA) to the maximum rating of the AT auto-transformer which is
600 VA. If the total calculated input of fan-coil elements is below 600 VA, only one auto-transformer will be sufficient, otherwise
an additional AT auto-transformer needs to be added to the electric circuit.
Caution: Allowed rating of thermostat and rpm switch must not be exceeded = max 3 A of induction load!
EXAMPLE OF AUTOMATIC REGULATION
We will compare the total calculated input (in our case it is 468 VA) to the maximum rating of the RM 01 control module which
is 400 VA. Due to the input, higher than 400 VA, we will select the RM 01 control module (400 VA) and one extension RoM 01
module (800 VA) by which we will obtain rating of 1200 VA.
Caution: Allowed rating of control module and rpm switch must not be exceeded = max 13 A of induction load (3.5 A for exten-
sion module)!
STAIN LESS DESIGN OF ELEMENTS
Since we anticipate that those elements are designed, first of all, for installation at pools or other humid areas, the 230/12 V
transformer is not mounted directly in the element, neither forms a part of the standard supply, but is placed in its own mount-
ing box to ensure operation on safety voltage. In this case it is necessary, besides the calculation of total input of elements for
correct selection of auto-transformer or automatic regulation control and extension modules, to select also a suitable 230/12 V
transformer. Transformers are produced in three sizes: T1 = 120 VA, T2 = 225 VA, T3 = 300 VA.
Multiple fan-coil elements can be connected to a single transformer if its input is sufficient. According to the example, we
would connect two PKVT 280/9/28 elements with 2 x 150 VA input to a single T3 (300 VA) transformer, and remaining two PKVT
160/9/28 elements with total input of 168 VA we would connect to a single T2 (225 VA) transformer. The entire regulation will be
connected to a single AT autotransformer, since its input of 600 VA is sufficient.
The installation must follow valid standards and safety regulations!
The manufacturer is not liable for any defects and damages caused by an unauthorised mounting.
2. st. 3. st.
Max. pkon
ventiltoru
(VA)
120 1255
34
918 1029
771 1984
50
452 1626
2463 2758
84
2019 2261
3177 3559
100
2604 2917
4035 4519
134
3307 3704
5084 5695
150
4167 4668
According to the project we have designed the following
types of fan-coils:
2 ks PKVT 160/9/28 - find the input in the table 84 VA
2 ks PKVT280/9/28 - find the input in the table 150 VA
Total input:
84 + 84 + 150 + 150 = 468 VA
57
information for mounting convectors Licon
Scheme of anchoring to the floor
L = convector length minus 300 mm (to the 1400 mm convector length)
minus 400 mm (to the 1400 mm 2000 mm convector length )
minus 600 mm (above the 2000 mm convector length)
L = 300 = spacing of central leg holes
Instructions for Installation
OL-stand models
a) Wall fixed to the wall Recommended installation is 10 cm above clean floor. The consoles supplied (2 pieces) allow both
height and length tolerance of ca 5 cm. Attaching spacing is specified on Figure.
b) Stand fixed to the floor. Customer can select between stands for rough or clean floor. Both variants allow height tolerance
of ca 5 cm. The spacings for attaching to the floor are shown on Figure.
Mounting procedure (applies for all models)
First step is proper measuring and drilling in the consoles. Then the heat exchanger is seated and connected to the heating
system. Last step is putting on the cover with the expiratory grid, its fastening to the console pins and bolting.
OL/D with plate
We recommend to fasten the element to the floor using a fastening anchor which is inside the side plate (leg).
After seating on the convector, the plates are fixed to prevent undesired motion.
See the Mounting Instructions for detail information. The elements are supplied assembled.
Mounting of Licon OL elements
Mounting location
Scheme of anchoring on the wall
Modern production
L = convector length minus 247 mm (to the 1400 mm convector length)
minus 347 mm (to the 1400 mm 2000 mm convector length )
minus 547 mm (above the 2000 mm convector length)
L = 300 = spacing of central leg holes
List of stands for OL fastening
width 18 cm width 24 cm width 18 cm width 24 cm width 18 cm width 24 cm
On the wall On clean floor
On rough floor
3
0
0

-

3
4
5
1
0
0
58
information for mounting convectors Licon
Mounting location
Consoles for floor installation Consoles for wall installation
OR-J2
OR-D2
OR-J3
OR-D3
OR-J2
OR-D2
OR-J3
OR-D3
Instructions for Installation
We recommend installation of wall-mounted heating element always on an external wall, 10 cm above the floor. Elements are
suspended on the wall using wall plugs, screws of special consoles which are included in the delivery. See the sketch of element
anchorage for the method of suspension on the wall. The consoles allow height tolerance of 5 cm. The elements are supplied
assembled.
Mounting the OK/C element is identical with the above described procedure. A 230 V voltage source must be near installation of
any element.
Mounting of Licon OK & OK/C elements
Instructions for Installation
Sufficient supply of heated air must be ensured for correct function, have sufficiently tight convector case and sufficiently
permeable expiratory grid (see Fig. on Page 47). Recommended installation of registers is 10 cm above clean floor. For this
purpose, we deliver 2 types of consoles. These can be in a floor-mounted design (stand-type) in 5 and 10 cm heights, or in a
wall-suspension design. The number of register tubes determined the width of the console. The consoles are not included in the
delivery.
Mounting of Licon OL elements
Anchorage scheme
back os convector

mounting set
59
Pressure losses
of convectors and valves,
weights and volumes of elements
Licon
R A D I T O R Y P R O I V O T
L = 100 cm
60
pressure losses of convectors Licon
60
Licon
Exchanger OR-J2
PK, PKVT, OL
L = 300 cm
L = 200 cm
L = 100 cm Exchanger OR-D2
PK, OL
L = 300 cm
L = 200 cm
L = 100 cm Exchanger OR-D3
PK, OL, OL/D
L = 300 cm
L = 200 cm
L = 100 cm
Exchanger OR-J3
PK, PKVT, OL
L = 300 cm
L = 200 cm
L = 100 cm
Exchanger OK
hloubka 9 cm
L = 200 cm
L = 100 cm
L = 40 cm Exchanger OK
hloubka 15 cm
L = 200 cm
L = 100 cm
L = 40 cm
Exchanger
PKVTi
L = 300 cm
L = 200 cm
L = 120 cm
Exchanger OK/C
CERAMIC
L = 117 cm
L = 97 cm
L = 77 cm
Exchanger
PKVTi/TWIN
L = 300 cm
L = 200 cm
L = 120 cm
P
r
e
s
s
u
r
e

l
o
s
s

(
P
a
)
P
r
e
s
s
u
r
e

l
o
s
s

(
P
a
)
P
r
e
s
s
u
r
e

l
o
s
s

(
P
a
)
P
r
e
s
s
u
r
e

l
o
s
s

(
P
a
)
P
r
e
s
s
u
r
e

l
o
s
s

(
P
a
)
P
r
e
s
s
u
r
e

l
o
s
s

(
P
a
)
P
r
e
s
s
u
r
e

l
o
s
s

(
P
a
)
P
r
e
s
s
u
r
e

l
o
s
s

(
P
a
)
P
r
e
s
s
u
r
e

l
o
s
s

(
P
a
)
Mass flow rate (kg/h) Mass flow rate (kg/h) Mass flow rate (kg/h)
Mass flow rate (kg/h) Mass flow rate (kg/h) Mass flow rate (kg/h)
Mass flow rate (kg/h)
Mass flow rate (kg/h) Mass flow rate (kg/h)
61
pressure losses of convectors Licon
61
Kv values of used valves
Kv values for valve Siemens VDN 215 1/2, direct
Pre-setting degree 1 2 3 4 5 N
Kv 0,10 0,20 0,31 0,45 0,69 0,89
Note: This type of valve is only used in OK/C.
Kv values for valve Licon/Danfoss RA-N 15 UK 1/2
Pre-setting degree 1 2 3 4 5 6 7 N
Kv 0,16 0,20 0,25 0,36 0,47 0,59 0,74 0,81
Note: This type of valve is used for optional accessories supplier for OL and OL/D.
Contents of set for connection of OL and OL/D elements
VALVE RA-N 15
- thermostatic valves Licon/Danfoss RA-N 15 1/2
- valve element with an option of flow presetting
- flow can be set without using tools
- basic setting can be selected in 7 grades
- maximum working overpressure 10 Bar
- maximum working temperature 120C
- threadless connection with thermostatic hose
THERMOSTATIC
HEAD
- thermostatic gas-steam head Licon/Danfoss RA 2000
- fastest reaction time
- alienation fuse
- limiting / blocking pins of temperature setting
EXTENSION PIECE
- serves for evening up the height between the inlet and outlet of exchanger screwing
- stainless design
- connecting thread G 1/2, inner
- A-straight piece for double-row exchangers (height OL and OL/D 15 cm and more)
- B bent piece for single-row exchangers (height OL 9 cm)
A
B
62
weights and volumes of elements Licon
Examples of conversion to variant temperature
difference:
Entered: heating element Licon OR-D2/140
Arithmetic working condition: 75/65/20 C
We shall convert Qn = 1135 W
to temperature difference t = 40 K
Q = Qn x coefficient kt = 1135 x 0.722 = 819 W
Entered: heating element Licon OK 140/60/9
Arithmetic working condition: 75/65/20 C
We shall convert Qn = 1072 W
to temperature difference t = 30 K
Q = Qn x coefficient kt = 1072 x 0.484 = 519 W
The kt coefficient can be found in the table of correction factors for specific element.
Examples of conversion
to variant temperature
difference
t = (tw1 + tw2) / 2 - ti
Where: tw1 is water inlet temperature (C)
tw2 is water outlet temperature (C)
ti is air temperature (C)
t is water cooling (K)
Coefficient of resistance is valid for both 1/2
Floor-mounted PK convectors
Type 9/16 9/20 9/28 9/42 11/16 11/20 11/28 11/42 15/28 15/42 19/28 19/42 30/28 30/42 45/28 45/42
kg/1bm 5 6 7 9 6 7 8 10 10 12 11 13 16 18 21 23
l/1bm 0,23 0,47 0,47 0,72 0,23 0,47 0,47 0,72 0,96 1,5 0,96 1,5 0,96 1,5 0,96 1,5
WEIGHTS AND WATER VOLUMES OF LICON CONVECTORS
Floor-mounted PKVT convectors
Type 7/28 9/28 11/28 11/42
kg/1bm 11 12 14 16
l/1bm 0,47 0,47 0,47 0,70
Floor-mounted PKVTi convectors
Type 13/28
kg/1bm 18
l/1bm 1
Floor-mounted PKVTi Twin convectors
Type 13/34
kg/1bm 22
l/1bm 1,46
Floor grids PM
Width 16 20 28 34 42 Width 16 20 28 34 42 Width 12 20 28 34 42
kg/1bm 4 5 7,5 8,5 11 kg/1bm 1,5 1,8 2 2,5 3 kg/1bm 2 2,5 3 3,5 4
STAINLESS WOOD ALUMINIUM
OL heating benches
Type 9/18 9/24 15/18 15/24 30/18 30/24 45/18 45/24 60/18 60/24
kg/1bm 10 11 14 15 19 20 23 24 28 29
l/1bm 0,5 0,8 1 1,6 1 1,6 1 1,6 1 1,6
OL/D heating benches, plates
Type 100
kg/1bm 10
l/1bm 1,6
Type teraco devo
kg/1bm 27 8
Wall-mounted convectors OK
Type 45/9 45/15 60/9 60/15
kg/1bm 15 16 18 19
l/1bm 1 1,5 1 1,5
Wall-mounted convectors OK/C
Type 97
kg/1bm 50
l/1bm 1,4
Heating registers OR
Type J1 J2 J3 D2 D3
kg/1bm 1,2 2,4 3,6 4,8 7,2
l/1bm 0,25 0,52 0,8 1 1,6
Note: Stated weights do not include the packaging
If needed, heating elements Licon can be equipped with heat
consumption meter. We recommend to use products of com-
pany VIPA, see www.vipa.cz for more information.
Calorimeter
63
General information
Licon
R A D I A T O R S F O R L I F E
64
general information Licon
Instructions for Transport & Storage
When transported, the elements must be handled with extreme care, and locked against motion and damage. The transport and
storage area must be dry and covered against weather conditions.
Maintenance
To prevent drop of heat output, the transition area of the exchanger should be clear off dust before the heating season, which is
performed best by vacuum cleaning using a brush damped in a detergent solution.
Quality
Since August 17, 2006, company Licon is a holder of the ISO 9001:2000 Quality Management Certificate issued by Austrian com-
pany QS. The products are further manufactured and tested accordingly with SN EN 442, and CE certificate is issued for the
products.
Warranties
10-year warranty is provided for tightness of exchanger. Other warranties are provided in accordance with Commercial Code, as
amended. Warranty certificates can be downloaded at: www.licon.cz, including detail warranty conditions.
Company Licon Heat, s. r. o shall not be held liable for any damages caused by improper mounting, or for any damages caused
due to wrong electric or heat-technical installation (e.g. variable voltage or hydraulic pressure which deviates substantially from
standard value).
Company Licon Heat, s. r. o reserves the right to modify technical specifications without previous notice.
C.1390-CPD-0026/05/P
Production
Survey of models produced
References
Licon
R A D I A T O R S F O R L I F E
65
66
survey of models produced Licon
Licon PK
Licon OL/D
Licon OK
Licon PKVT
Licon OL
Licon OR
Licon PKVTi Licon PKVTi TWIN
Licon OK/C
Airport,
Brno
Jaguar & Land Rover Motor Show
Prague
Company Celsis Headquarters,
Lithuania
The Jetd Hotel,
Liberec
Copenhagen Island Hotel
Denmark
Administration building,
Denmark
Residential Complex Karlslunde,
Denmark
Tipsport Arena,
Liberec
Musical Theatre Karln,
Prague 8
SAS Radisson Hotel
Prague 1
Technical University,
Liberec
University,
Brno
REFERENCES
Should you request more detail
information, visit our
web: www.licon.cz
Your professional partner: 01/2009 CZ
Address:
Licon Heat s.r.o.
Registered office:
Krajnkova 2390/11
141 00 Praha 4
Phone: +420 485 131 157
Fax: +420 485 130 331
Email: info@licon.cz
www.licon.cz