Digital SimCode is a proprietary
language devices created with it are
not compatible with other simulators,
nor are digital components created for
other simulators compatible with
Altium Designer's Mixed-Signal Circuit
Simulator.
Due to the complexity of digital devices it is generally not practical to simulate them using
standard, non-event-driven SPICE instructions. For this reason Altium Designer's Mixed-
Signal Circuit Simulator includes a special descriptive language that allows digital devices
to be simulated using an extended version of the event-driven XSPICE. This language
used to model digital devices is called Digital SimCode.
SimCode is a C like description language. You use it to define the characteristics and
behavior of the device you are modeling. It includes functions to define parameters such
as propagation delays, load characteristics, strengths,
and so on. The device behavior is defined using truth
tables, math functions and conditional control
statements, such as IF .. THEN statements.
SimCode source files are written as plain ASCII text
files and saved with the .txt extension.
For information on linking a SimCode model to a schematic component, refer to the Creating and Linking a Digital SimCode
Model application note.
Beginning a SimCode Model Definition
A SimCode device definition begins with a # xxxx source statement. This statement has the form:
# <func name> source
where <func name> is the name of the simulation function used to identify the model definition block. The model definition block
ends with the EXIT statement. Therefore, a SimCode model for a particular device takes the general form:
# MyDevice source
...
...
...
EXIT;
In the above code fragment, the .MODEL statement contained in the .MDL file referenced by the schematic part symbol would
call the function MyDevice in order to simulate the device.
A single SimCode text file can contain any number of model definitions.
SimCode Statement Termination Character
The SimCode language uses the semicolon character " ; " to mark the end of a SimCode statement.
In SimCode, a statement may occupy a single line of code, or take up several lines. The termination character marks the
termination of the complete SimCode statement and is placed immediately after the last clause of the statement, as shown in
the following examples:
DELAY Q1 Q2 Q3 Q4 = 10n;
DELAY Q QN =
CASE (TRAN_LH) : tplh_val
CASE (TRAN_HL) : tphl_val
END;
data = (E0_1 && (CHANGED(D0) || CHANGED(D1)));
DELAY Q1 Q0 =
Summary
This comprehensive
reference describes the
Digital SimCode
language used to
specify simulation
models for digital
devices. The reference
includes in-depth
descriptions for each of
the constituent functions
for the language.
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 2
CASE (data && TRAN_LH) : tplh_D_Q
CASE (data && TRAN_HL) : tphl_D_Q
CASE (TRAN_LH) : tplh_E_Q
CASE (TRAN_HL) : tphl_E_Q
END;
Including Comments in SimCode Files
You may include comments in a SimCode file by preceding the comments with two "slash" characters //. Everything after the
slash characters is ignored. Comments can appear as complete lines, or after a SimCode line, as shown in the following
examples:
EVENT = (present_time + 1e-6); //return in 1us
DELAY Q QN =
// Case 1
CASE (TRAN_LH) : tplh_val
// Case 2
CASE (TRAN_HL) : tphl_val
END;
Comments should be placed in SimCode models to make the code more readable and to aid in debugging.
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 3
SimCode Language Definition
The following items make up the Digital SimCode language, which is then used to construct a digital device simulation model.
Each individual item topic gives full syntax descriptions and examples of usage. In describing the language syntax, the following
style is used:
< > value/variable/pin/expression
[ ] optional parameter
{ }|{ } selections (you must choose ONE of these parameters)
Device Definition Functions
Functions used to define device pins, etc.
INPUTS
OUTPUTS
INTEGERS
REALS
PWR_GND_PINS
IO_PAIRS
Device Setup Functions
Functions used to set certain characteristics of the device pins:
VIL_VIH_VALUE
VIL_VIH_PERCENT
VOL_VOH_MIN
Device Test Functions
Functions used to test for any device setup violations which may occur in the circuit:
SUPPLY_MIN_MAX
RECOVER
SETUP_HOLD
WIDTH
FREQUENCY(FMAX)
Output Pin Functions
Functions used to program the output pins of a device:
STATE
STATE_BIT
LEVEL
STRENGTH
TABLE
EXT_TABLE
LOAD
DRIVE
DELAY
NO_CHANGE
EVENT
Expression Operators and Functions
Used in expressions to manipulate data and to make comparisons which control program flow:
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 4
OPERATORS
MATH FUNCTIONS
PARAM_SET
PWL_TABLE
SELECT_VALUE
MIN_TYP_MAX
NUMBER
VALUE
CHANGE_TIME
WIDTH_TIME
INSTANCE
CHANGED_xx
READ_DATA
Program Control
Functions used to control the flow of the program:
# xxxx source
IF ... THEN
WHILE ... DO
GOTO
GOSUB
RETURN
EXIT
Text Output
Functions used to display messages during simulation and debugging:
PROMPT
MESSAGE
Debug
Functions used to trace through the execution of the SimCode for debugging purposes:
STEP_ON
STEP_OFF
# xxxx source
Syntax
# <func name> source
Description
Identifies the beginning of the SimCode source function. This statement identifies the SimCode function so that it can be called
when it is time to simulate this device. It must be the first statement of each Digital SimCode device function.
Parameters
<func name> - Name of the SimCode function.
Examples
//==================================
# MyDevice source
//==================================
INPUTS VCC, GND, IN1, IN2;
OUTPUTS VCC_LD, IN1_LD, IN2_LD, OUT;
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 5
.
.
.
EXIT;
Notes
The Simulator has the ability to read either uncompiled SimCode source models, or compiled SimCode models. The keyword
source identifies this as a SimCode source model to the Simulator, which automatically compiles the model, on-the-fly, when
the simulation is run.
Should you wish for the compiled model information to be written to file, ensure that the Create compiled SimCode output file
option is enabled in the Simulation Preferences dialog. This dialog is accessed by clicking on the Preferences button in the
Analyses Setup dialog (Design Simulate Mixed Sim). The compiled output is written to an ASCII text file
SimCodeFunctionName simlist.txt which, by default, is stored in the same directory as the ASCII SimCode source
model itself (\Library\Sim). The compiled model information can be extracted to create a compiled SimCode model file
(*.SCB).
CHANGE_TIME
Syntax
CHANGE_TIME(<pin>)
Description
This function returns a real value that indicates the last time the specified input or output pin changed states.
Parameters
<pin> - Input or output pin name.
Examples
T1 = (CHANGE_TIME(INA));
CHANGED_xx
Syntax
CHANGED_xx(<pin> [{<}|{<=}|{>}|{>=} <var/time/value>])
Description
This function is used to determine if the specified pin has changed state.
The _xx that follows the keyword CHANGED can be eliminated (to indicate any type of change) or the xx can be set to:
LH, LX, HL, HX, XL, XH, LZ, ZL, ZH, ZX, HZ or XZ
to indicate a specific type of change. The optional compare operator (<, <=, >, >=) and <var/time/value> would be included to
check for a more specific change. If they are not included, the function will return 1 if the pin has changed at the current
simulation step.
Parameters
<pin> - Input or output pin name.
<var/time/value> - Item to which <pin> is compared.
Examples
IF (CHANGED_LH(CLK)) THEN ...
IF (CHANGED(DATA < 10n)) THEN ...
DELAY
Syntax 1
DELAY <output> [<output> ...] = <delay>;
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 6
Syntax 2
DELAY <output> [<output> ...] =
CASE (<conditional exp>) : <delay>
CASE (<conditional exp>) : <delay>
[CASE (<conditional exp>) : <delay> ...]
END;
Description
Sets propagation delay to specified outputs. The DELAY command is executed once for each pin listed and posts a propagation
delay for each pin that has changed its level. The CASE option allows more than one <delay> to be specified. The <conditional
exp> then determines which <delay> will be used. If a delay is set for a pin that has not changed then the pin will be flagged as
NO-CHANGE and the delay will not be posted. The <delay> can be a real constant, a real variable or a real expression.
Parameters
<output> - Name of/variable index to the output pin.
<conditional exp> - Conditional expression that determines which delay is used.
<delay> - Propagation delay time to the output pin.
Examples
DELAY Q1 Q2 Q3 Q4 = 10n;
DELAY Q QN =
CASE (TRAN_LH) : tplh_val
CASE (TRAN_HL) : tphl_val
END;
data = (E0_1 && (CHANGED(D0) || CHANGED(D1)));
DELAY Q1 Q0 =
CASE (data && TRAN_LH) : tplh_D_Q
CASE (data && TRAN_HL) : tphl_D_Q
CASE (TRAN_LH) : tplh_E_Q
CASE (TRAN_HL) : tphl_E_Q
END;
In this example, if data is nonzero and Q1 is changing from High to Low, the tphl_D_Q delay will be posted for Q1. Then, if Q0
is changing from Low to High, the tplh_D_Q delay will be posted for Q0.
Notes
The DELAY command must be executed exactly once for each output pin, that is, for each pin declared in the OUTPUTS
statement which is NOT listed in the LOAD or NO_CHANGE statements. The order in which the delays are set is based on the
order in which these pins are listed in the DELAY command (i.e. first pin listed is set first). Each <conditional exp> is evaluated
in the order it is listed until one expression evaluates TRUE. When this occurs, the <delay> value associated with the TRUE
expression is posted for the output being set. When using the CASE option, at least one <conditional exp> should evaluate as
TRUE for each output pin listed. If no <conditional exp> evaluates to TRUE, the <delay> associated with the last CASE
statement is posted.
In addition to the standard expression functions, the following terms apply only to the output pin being set and can be used in
the <conditional exp>:
TRAN_LH low-to-high transition
TRAN_LX low-to-other transition
TRAN_HL high-to-low transition
TRAN_HX high-to-other transition
TRAN_HZ high-to-tristate transition
TRAN_XL other-to-low transition
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 7
TRAN_XH other-to-high transition
TRAN_LZ low-to-tristate transition
TRAN_ZL tristate-to-low transition
TRAN_ZH tristate-to-high transition
TRAN_ZX tristate-to-other transition
TRAN_XZ other-to-tristate transition
TRAN_XX other-to-different transition.
If the <delay> value is less than or equal to 0.0 a run-time error message will be displayed. Output pins can be specified by
using the output pin name or by an integer variable that contains the index of an output pin. Pin names and variables cannot be
mixed in the same DELAY statement. References to outputs must be either all pin names or all variable names.
DRIVE
Syntax
DRIVE <output> [<output> ...] =
(v0=<value> v1=<value> ttlh=<value> tthl=<value>);
Description
Declares drive characteristics of output pins. The DRIVE command is used to declare the output pins drive characteristics.
When the output is set to a LOW state, the output pin is connected to voltage value v0 through resistance rol_param. When
the output is set to a HIGH state, the output pin is connected to voltage value v1 through resistance roh_param. The low-to-
high transition time is set by ttlh and the high-to-low transition time is set by tthl.
Parameters
<output> - Name of or variable index to the output pin.
v0<value> - VOL for the output pin. <value> can be a real value or variable.
v1<value> - VOH for the output pin. <value> can be a real value or variable.
ttlh<value> - Low-to-high transition time for the output pin. <value> can be a real value or variable.
tthl<value> - High-to-low transition time for the output pin. <value> can be a real value or variable.
Examples
rol_param = (MIN_TYP_MAX(drv_param: 62.5, 43.75, NULL);
roh_param = (MIN_TYP_MAX(drv_param: 262.5, NULL, 52.5);
DRIVE Q QN = (v0=vol_param,v1=voh_param,ttlh=ttlh_val,
tthl=tthl_val);
Notes
Pin names and variables cannot be mixed in the same DRIVE statement. References to outputs must be either all pin names or
all variable names.
The values used for rol_param should be derived using the data book specs for VOL. This value represents the total
saturation resistance of the pull-down structure of the devices output. A standard LS output in the LOW state, for example,
sinking 8mA will not exceed 0.5V, typically closer to 0.35V. Therefore:
for typ LOW state drive:
rol_param = VOLtyp / IOLmax
rol_param = 0.35V / 8mA
rol_param = 43.75 ohms.
for min LOW state drive:
rol_param = VOLmax / IOLmax
rol_param = 0.5V / 8mA
rol_param = 62.5 ohms.
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 8
The values used for roh_param should be derived using the data book specs for IOS, if available. This value represents the
total saturation resistance of the pull-up structure of the devices output. A standard LS output in the HIGH state with the output
shorted to ground and Vcc=5.25V will source at least 20mA but not more than 100mA. Therefore:
for min HIGH state drive:
roh_param = VCCmax / IOSmin
roh_param = 5.25V / 20mA
roh_param = 262.5 ohms.
for max HIGH state drive:
roh_param = VCCmax / IOSmax
roh_param = 5.25V / 100mA
roh_param = 52.5 ohms.
EVENT
Syntax
EVENT = ({<time>}|{<expression>})
Description
Causes a digital event to be posted. In most cases a digital event is posted when one or more INPUT pins for a SimCode model
changes state. When the event is processed, the SimCode for the specified event is called and run. This instruction allows a
SimCode model to post a digital event at a specified <time>. If the specified EVENT time is greater than the simulation time
(indicated by present_time), then a digital event will be posted. If more than one EVENT is posted in a single call to a
SimCode model, only the longest EVENT <time> will be used. This function allows the creation of one-shots and other similar
device models.
Parameters
<time> - Time at which event should occur.
<expression> - Expression indicating time at which event should occur.
Examples
EVENT = (present_time + 1e-6); //return in 1us
Notes
If a digital event for a specific SimCode model occurs before an EVENT <time> posted by that SimCode, the EVENT <time>
must be posted again. For example, if:
the present simulation time is 1us,
a SimCode model sets EVENT = 2us and
an INPUT pin in the SimCode model changes state at 1.5us,
then the 2us event must be posted again.
EXIT
Syntax
EXIT
Description
Terminates SimCode execution.
Notes
This is the last line of a SimCode model, but it may also be placed at other locations to abort execution of remaining SimCode.
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 9
EXT_TABLE
Syntax
EXT_TABLE <line>
<input pin> [<input pin> ...] <output pin> [<output pin> ...]
<input state> [<input state> ...]
<output state> [<output state> ...];
Description
Sets output logic states based on extended truth table. The EXT_TABLE statement is an extended truth table function used to
set the level and strength of the specified outputs.

Valid input states are:
0 low (input voltage is <= vil_param)
1 high (input voltage is >= vih_param)
^ low-to-high-transition
v high-to-low-transition
X dont care what input voltage is
Valid output states are:
L ZERO (set output level to vol_param).
H ONE (set output level to voh_param).
Z UNKNOWN (set output level to v3s_param).
It also allows INPUT and/or OUTPUT pin names with optional prefixes to specify the output states. Prefixes are:
- State is the previous state.
~ State is the inverse of the state.
-~ State is the inverse of the previous state.
Output state letters can be followed by a colon and a letter to indicate strength:
s STRONG (set output to rol_param for L and roh_param for H).
z HI_IMPEDANCE (set output to r3s_param).
If a strength character is not specified after an output state then STRONG will be used for L and H states and HI_IMPEDANCE
will be used for Z states.
Parameters
<line> - Variable into which the line number used in the table is placed
<input pin> - Name of the input pin
<output pin> - Name of the output pin
<input state> - State of the individual inputs
<output state> - State of the individual outputs based on input conditions
Examples
EXT_TABLE tblIndex
PRE CLR CLK DATA Q QN
0 1 X X H L
1 0 X X L H
0 0 X X H H
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 10
1 1 ^ X DATA ~DATA
1 1 X X Q ~Q;
This example is representative of 1/2 of a 7474 D type flip-flop. If input pins PRE, CLR, and DATA are all high (>= vih_param) and
CLK has a low-to-high transition, Q is set to high (voh_param) and STRONG (roh_param), QN is set to low (vol_param) and
STRONG (rol_param) and tblIndex is set to 4.
Notes
Each row is tested sequentially from top to bottom until the input conditions are met. The outputs are set for the first row to meet
the input conditions. <line> is set to the line number in the table that was used. If no match was made then <line> is set to 0. Pin
names used to specify output states do not need to be in the table heading. Unlike the TABLE statement, input variables are
not allowed.
FREQUENCY (FMAX)
Syntax
FREQUENCY(<input> [<input>...] MIN=<frequency> MAX=<frequency> ["<message>"])
Description
Tests inputs for minimum and maximum frequency violation. The FREQUENCY function compares the <input> period (the time
from one low-to-high edge to the next low-to-high edge) with the reciprocal of the specified <frequency> (1/freq). If the time
period for the <input> is smaller than the reciprocal of the specified MAX frequency or the time period for the <input> is greater
than the reciprocal of the specified MIN frequency, then a WARNING will be displayed. An optional <message> string can be
included in the FREQUENCY statement which will be output if a WARNING is displayed.
Parameters
<input> - Name of or variable index to the input pin under test.
MIN=<frequency> - Minimum frequency allowed on the pin under test.
MAX=<frequency> - Maximum frequency allowed on the pin under test.
<message> - Text string that will be displayed if a warning occurs.
Examples
FREQUENCY(CLK MAX=10MEG "CLK"); //check fmax only
Notes
Data book specifications should be used with this function. Pin and variable names can be mixed in the same FREQUENCY
statement. Only the first FREQUENCY failure for each pin listed will be reported.
GOSUB
Syntax
GOSUB <label>;
Description
Jumps to a subroutine in the SimCode. The GOSUB instruction is used to perform non-sequential execution of the SimCode.
However, unlike the GOTO statement, SimCode execution will continue from the instruction following the GOSUB instruction,
when a RETURN instruction is encountered.
Parameters
<label> - Location in SimCode where program flow resumes.
Examples
GOSUB Shift_Left;
.
Exit;
Shift_Left:
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 11
.
RETURN:
GOTO
Syntax
GOTO <label>;
Description
Jumps to a new location in the SimCode. The GOTO instruction is used to perform non-sequential execution of the SimCode.
Parameters
<label> - Location in SimCode where program flow resumes.
Examples
GOTO Shutdown;
.
Shutdown:
.
Exit;
Notes
Program flow resumes from the location where <label>: appears in the SimCode. <label> must begin with an alpha character,
followed by any number of alpha-numeric characters or the underscore ( _ ) character. Where <label> appears in the code, it
must be followed immediately by a colon ( : ).
IF ... THEN
Syntax 1
IF (<expression>) THEN BEGIN ... [ELSE ...] END;
Syntax 2
IF (<expression>) THEN GOTO <label>;
Description
Conditionally controls flow through the SimCode.
The IF ... THEN statement is used to control the flow of the program, based on whether <expression> evaluates to true or false.
Multiple IF ... THEN statements may be nested.
Parameters
<expression> - Any expression that can be evaluated as true or false.
<label> - Location in SimCode where program flow resumes.
Examples
IF (EN) THEN
BEGIN
STATE Q0 = UNKNOWN;
ELSE
IF (IN2) THEN
BEGIN
STATE Y2 = ONE;
ELSE
STATE Y2 = ZERO;
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 12
END;
END;
IF (x = -2) THEN GOTO Do_Neg2;
...
Do_Neg2:
...
Notes
When the BEGIN ... ELSE ... END form of this statement is used and <expression> evaluates to true, program flow resumes
from the BEGIN statement and skips any optional SimCode between the ELSE and END statements. If <expression> evaluates
to false, program flow resumes from the optional ELSE statement if it exists or after the END statement if it does not exist.
When the GOTO form of this statement is used and <expression> evaluates to true, program flow resumes from the location
where <label>: appears in the SimCode. <label> must begin with an alpha character, followed by any number of alpha-numeric
characters or the underscore ( _ ) character. Where <label> appears in the code, it must be followed immediately by a colon ( :
).
INPUTS
Syntax
INPUTS <input pin>[, <input pin>, ...];
Description
Declares input pins (pins that monitor the circuit). The INPUTS data type is used to define the pins which monitor stimulus
external to the device. These generally include input, i/o, power and ground pins.
Parameters
<input pin> - Name of the input pin.
Examples
INPUTS VCC, GND, PRE, DATA, CLK, CLR;
Notes
Input pin names must begin with a letter and be defined before they are used.
INSTANCE
Syntax
INSTANCE("<instance name>")
Description
Checks if this is the specified device instance. The INSTANCE function returns 1 if the present instance of the SimCode device
matches the <instance name> specified. Otherwise it returns 0.
Parameters
<instance name> - Text string indicating instance name.
Examples
IF (INSTANCE("AU23")) THEN
BEGIN
MESSAGE("U23-Q0 = %d", Q0);
END;
Notes
A circuit may contain more than one of any given device. During simulation it may be important to know if the device being
simulated at this moment is the one you are interested in. This would allow you, for example, to print messages for one specific
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 13
NAND gate without having to wade through messages for all the other NAND gates as well. The instance name is the device
Designator preceded by its SPICE Prefix Character (the letter A).
INTEGERS
Syntax
INTEGERS <var>[, <var>, ...];
Description
The INTEGERS data type is used to define integer variables and arrays.
Parameters
<var> - Name of the variable.
Examples
INTEGERS tblIndex, count, data[64];
Notes
Integer variables and arrays must begin with a letter and be defined before they are used. Integer arrays are defined by
following the array name with a left bracket ( [ ), an integer number which defines the size of the array, and a right bracket ( ] ).
Integer arrays can be set and/or used in expressions.
The following are reserved SimCode integer variables which do not need to be declared:
Variable Use Digital Model Parameter SPICE Option
tp_param tplh/hl index Propagation TPMNTYMX
tt_param ttlh/hl index N/A TTMNTYMX
ld_param LOAD index Loading LDMNTYMX
drv_param DRIVE index Drive DRVMNTYMX
i_param ICC index Current IMNTYMX
user_param USER index User Defined Parameter USERMNTYMX
warn_param Warning
messages
WARN SIMWARN
init_sim Once during
SimCode
initialization
N/A N/A
tran_pin TRAN_xx pin
index
N/A N/A
The first six variables in this list are expected to have a value of 1, 2 or 3. These values represent an index into the min/typ/max
arrays:
Value Represents
1 Index to minimum value.
2 Index to typical value.
3 Index to maximum value.
The Digital Model Parameter can be set independently for each digital device using the respective parameters found on the
Parameters tab of the Sim Model dialog. This dialog is accessed by double-clicking on the entry for the simulation model link in
the Models region of the associated Component Properties dialog.
If a SPICE Option parameter is set on the Advanced Options page of the Analyses Setup dialog, that setting will globally
override the Digital Model Parameter settings for all digital devices. If the variable is set explicitly in the SimCode, that setting
will override all other settings.
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 14
warn_param can be set to any positive value to conditionally display warning messages for the device. Different levels of
warning could be created by the device programmer, accessed by entering different positive values. The value of init_sim is
set 1 during SimCode initialization, otherwise it is set to 0. The value of tran_pin is set to the index of the pin being set during
a DELAY CASE statement. This index is used to determine which pin the TRAN_xx instruction is applied to.
IO_PAIRS
Syntax
IO_PAIRS (<ipin:opin>[, <ipin:opin>, ...]);
Description
Declares input/output pin associations for input loading. The IO_PAIRS statement defines which of the INPUTS pins are
associated with which of the OUTPUTS pins. This association is used by the LOAD statement.
Parameters
<ipin :opin> - Pin names of associated input and output pins.
Examples
IO_PAIRS (IN1:IN1_LD, IN2:IN2_LD);
In this example, IN1 and IN2 are INPUTS and IN1_LD and IN2_LD are OUTPUTS. IN1 and IN1_LD both refer to the same
physical pin on the device.
Notes
Each physical input pin on a device consists of both an ipin and an opin in SimCode. The opin is required to provide input
loading characteristics. This statement can only be used once in the SimCode. Power pins are not listed in the IO_PAIRS
statement.
LEVEL
Syntax 1
LEVEL <output> [<output> ...] = (<expression>);
Syntax 2
LEVEL <output> [<output> ...] = {ZERO}|{ONE}|{UNKNOWN};
Description
Sets the level of the output state. The state of an output pin is determined by its level and its strength. Use the LEVEL
command to set the level of one or more output pins.
<expression> State Level
<= vol_param ZERO vol_param
>= voh_param ONE voh_param
other UNKNOWN v3s_param
Parameters
<output> - Name of or variable index to the output.
<expression> - Any expression compared to VOL or VOH.
Examples
LEVEL Q = ONE;
LEVEL Q1 Q2 Q3 Q4 = ZERO;
LEVEL OUT = ((1+2)/3);
In the last example, OUT will be:
ZERO if vol_param > 1
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 15
UNKNOWN if vol_param < 1 and voh_param > 1
ONE if voh_param < 1
Notes
Output pins can be specified by using the output pin name or by an integer variable that contains the INDEX of an output pin.
Pin and variable names cannot be mixed in the same LEVEL statement. References to outputs must be either all pin names or
all variable names.
LOAD
Syntax
LOAD <output> [<output> ...] =
v0=<value> r0=<value> [v1=<value> r1=<value>] [io=<value>] t=<value>);
Description
Declares loading characteristics of input pins. The LOAD command is typically used with input or power pins to provide loading
for the driving circuit. Since only output pins can provide a load, each input must have a corresponding output. These are
assigned using the IO_PAIRS statement.
If different loads are required for different inputs, multiple LOAD statements may be used. Power pins should be placed in a
separate LOAD statement which does not include the v1/r1 load or io. Power pins are not included in the IO_PAIRS
statement. The IO_PAIRS statement must be entered before any LOAD statements that contain io.
Parameters
<output> - Name of or variable index to the output pin.
v0 - Load voltage for HIGH state input. <value> can be a real constant or a real variable.
r0 - Load resistance for HIGH state input. <value> can be a real constant or a real
variable.
v1 - Load voltage for LOW state input. <value> can be a real constant or a real variable.
r1 - Load resistance for LOW state input. <value> can be a real constant or a real
variable.
io - Off-state load resistance for unused load. <value> must be a real constant
t - Time delay before the load will be applied. <value> must be a real constant
Examples
r0_val = (MIN_TYP_MAX(ld_param: NULL, NULL, 125k);
r1_val = (MIN_TYP_MAX(ld_param: NULL, NULL, 10.5k);
ricc_val = (MIN_TYP_MAX(ld_param: NULL, 833, 525);
LOAD PRE_LD DATA_LD CLK_LD CLR_LD = (v0=vol_param, r0=r0_val,
v1=voh_param, r1=r1_val, io=1e9, t=1p);
LOAD VCC_LD = (v0=gnd_param, r0=ricc_val, t=1p);
Notes
An input load consists of a voltage and a resistance (v0/r0 or v1/r1). The voltage level of the incoming signal determines which
load will be used. If the voltage level goes below VIL and remains below VIH, then the input is considered to be in the LOW
state and the v1/r1 is applied. If the voltage level goes above VIH and remains above VIL, then the input is considered to be in
the HIGH state and the v0/r0 is applied. io is the input state off resistance. The unused load is essentially removed from the
circuit by changing its r value to the value specified for io.
The values for v0, r0, v1 and r1 can be either real constants or real variables. The values for io and t must be real
constants. Pin names and pin variables cannot be mixed in the same LOAD statement. References to outputs must be either all
pin names or all variable names.
For input pins, the values used for r0 should be derived using the data book specs for IIH. A standard LS input, for example, will
sink a maximum of 20uA at Vin=2.7V. Therefore, if vol_param = 0.2V, then:
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 16
for max HIGH state load:
r0 = (Vin - vol_param) / IIHmax
r0 = (2.7V - 0.2V) / 20uA
r0 = 125k ohms
The values used for r1 should be derived using the data book specs for IIL. A standard LS input, for example, will source a
maximum of 400uA at Vin=0.4V. Therefore, if voh_param = 4.6V then:
for max LOW state load:
r1 = (voh_param - Vin) / IILmax
r1 = (4.6V - 0.4V) / 400uA
r1 = 10.5k ohms
For power pins, the value used for r0 should be derived using the data book specs for ICC. For a 74LS151, Icc typ is 6mA at
Vcc=5V and Icc max is 10mA at Vcc=5.25V. Therefore:
for Icc typ : r0 = 5V / 6mA = 833 ohms
for Icc max : r0 = 5.25V / 10mA = 525 ohms
If creating a multiple-parts-per-package device, such as a 74LS00 quad NAND gate, you should adjust the Icc load for the
individual parts accordingly.
MATH FUNCTIONS
The following mathematical functions can be used in SimCode models:
Function Description Example
POW power X= (12 POW(3));
ABS absolute value X= (ABS(-12));
SQRT square-root X= (SQRT(2));
EXP exponent X= (EXP(10));
LOG natural log X= (LOG(0.1));
LOG10 log base 10 X= (LOG10(0.1));
SIN sine X= (SIN(0.1));
COS cosine X= (COS(0.1));
TAN tangent X= (TAN(0.1));
ASIN arc sine X= (ASIN(0.1));
ACOS arc cosine X= (ACOS(0.1));
ATAN arc tangent X= (ATAN(0.1));
HSIN hyperbolic sine X= (HSIN(0.1));
HCOS hyperbolic cosine X= (HCOS(0.1));
HTAN hyperbolic tangent X= (HTAN(0.1));
MESSAGE
Syntax
MESSAGE("<message>"[, <value/pin>...]);
Description
Displays a message without pausing. The MESSAGE statement is used to output the information specified by the <message>
string. It does not interrupt the simulation. The message is displayed in the status window during simulation.
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 17
Parameters
<message> - Message string including formatting characters as needed.
<value> - Variable or constant value.
<pin> - Pin name or index to pin variable.
Examples
MESSAGE("device instance= %s",INSTANCE);
Notes
A format string in MESSAGE is similar to a format that may be used in a printf statement in C. Valid formatting characters
include (but are not limited to):
\t tab
\n new line
\r carriage return
%d Decimal display for short variable or current input/output state.
%D Decimal display for short variable or old input/output state.
%x Hex display for short variable or current input/output state.
%X Hex display for short variable or old input/output state.
%c Character display for short variable or current input/output state.
%C Character display for short variable or old input/output state.
%e Exponential display for real variable.
%f Floating point engineering display for real variable.
%g Short display (%e or %f) for real variable.
%s String constant display.
The only valid string constants are:
INSTANCE The present SimCode device instance name.
FUNC The present SimCode device function name.
FILE The present SimCode device file name.
MIN_TYP_MAX
Syntax
MIN_TYP_MAX(<index>: <min>, <typ>, <max>);
Description
Returns value from MIN_TYP_MAX look-up table. The MIN_TYP_MAX function is similar to the SELECT_VALUE function
except that three values/variables must be entered. The keyword NULL can be substituted for one or two unknown values. If a
predefined integer variable (see INTEGERS) is used as the <index>, unknown (NULL) values are calculated from the known
values as follows:
Known Values Formula
<min>, <max> typical = (<max> + <min>) / 2
<min> only typical = (<min> / <min scale factor>)
maximum = (<min> / <min scale factor>) * <max scale factor>
<typ> only minimum = (<typ> * <min scale factor>)
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 18
maximum = (<typ> * <max scale factor>)
<max> only minimum = (<max> / <max scale factor>) * <min scale factor>
typical = (<max> / <max scale factor>)
Parameters
<index> - Input variable (index to select min (1), typ (2) or max (3) values).
<min> - Minimum data book value.
<typ> - Typical data book value.
<max> - Maximum data book value.
Examples
tplh_val = (MIN_TYP_MAX(tp_param: NULL, 5n, NULL));
In this example, if we assume that the SPICE options PROPMNS and PROPMXS are set to their default values (see Notes),
then:
if tp_param = 1 (i.e. return the min value), then tplh_val = 2.5n
if tp_param = 2 (i.e. return the typ value), then tplh_val = 5n
if tp_param = 3 (i.e. return the max value), then tplh_val = 7.5n
ricch_val = (MIN_TYP_MAX(i_param: NULL, 2500, 1250));
In this example, if we assume that the SPICE options CURRENTMNS and CURRENTMXS are set to their default values (see
Notes), then:
if i_param = 1 (i.e. return the min value), then ricch_val = 3750
if i_param = 2 (i.e. return the typ value), then ricch_val = 2500
if i_param = 3 (i.e. return the max value), then ricch_val = 1250
Notes
If <index> is not one of the predefined variables listed below, then <min scale factor> = 0.5 and <max scale factor> =
1.5.
The <min scale factor> and <max scale factor> for each of these predefined variables can be changed on the
Advanced Options page of the Analyses Setup dialog (Design Simulate Mixed Sim). The <min scale factor> and
<max scale factor> are reversed for ld_param, drv_param and i_param because these parameters control a resistance
value rather than a current value (i.e., maximum load equates to minimum resistance.)
Variable SPICE Option Parameter Default
tp_param PROPMNS <min scale factor> = 0.5
PROPMXS <max scale factor> = 1.5
tt_param TRANMNS <min scale factor> = 0.5
TRANMXS <max scale factor> = 1.5
ld_param LOADMNS <min scale factor> = 1.5
LOADMXS <max scale factor> = 0.5
drv_param DRIVEMNS <min scale factor> = 1.5
DRIVEMXS <max scale factor> = 0.5
i_param CURRENTMNS <min scale factor> = 1.5
CURRENTMXS <max scale factor> = 0.5
vth_param VTHMNS <min scale factor> = 0.5
VTHMXS <max scale factor> = 1.5
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 19
user_param USERMNS <min scale factor> = 0.5
USERMXS <max scale factor> = 1.5
NO_CHANGE
Syntax
NO_CHANGE <output> [<output> ...];
Description
Use the NO_CHANGE function to indicate no-change for specified output pins. Use this statement on bi-directional pins when
the bi-directional pin is being treated as an input.
Parameters
<output> - Name of or variable index to the output pin.
Examples
NO_CHANGE Q1 Q2 Q3 Q4;
Notes
Pin names and variables cannot be mixed in the same NO_CHANGE statement. References to outputs must be either all pin
names or all variable names.
NUMBER
Syntax
NUMBER(<MSB pin>, [<pin>, ...] <LSB pin> );
Description
Returns number based on binary weighted pin states. The NUMBER function returns a short integer that represents the decimal
value of the binary number represented by the list of <pin>. Each bit (represented by a <pin>) is set to 1 if the <pin> is non-zero,
otherwise it is set to 0.
Parameters
<pin> - Name of or index to a pin.
Examples
A = (NUMBER(D3,D2,D1,D0));
In this example, if D3 is HIGH, and D2, D1 and D0 are LOW (1000), then A = 8.
Notes
The first <pin> in the list represents the most-significant-bit (MSB) and the last <pin> in the list represents the least-significant-
bit (LSB).
OPERATORS
The following operators can be used in SimCode expressions:
= Equals (sets a variable or output pin to a value or state).
+ Add
- Subtract
* Multiply
/ Divide
~ Logical not
! Bitwise complement
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 20
&& AND
|| OR
^^ XOR
Bitwise Operators
& AND
| OR
^ XOR
<< Shift left
>> Shift right
Relative Comparators
= Equal
!= Not equal
< Less than
<= Less than or equal to
> greater than
>= greater than or equal to
Description
Operators are used to set and manipulate variables and expressions.
Examples
clk_twl = (25n);
reg = (reg + 1);
vx = (vol_param - 10m);
C = (A * B);
val = (xval / 2);
X = (A && ~(B));
Y = (!(X)); //if X=1 then Y=FFFFFFFE
A = (X & 1); //if X=1 then A=1, if X=2 then A=0
B = (X | 8); //if X=1 then B=9, if X=2 then B=10
C = (X >> 2); //if X=1 then C=0, if X=2 then C=0
D = (2 >> X); //if X=1 then D=1, if X=2 then D=0
E = (X << 2); //if X=1 then E=4, if X=2 then E=8
F = (2 << X); //if X=1 then F=4, if X=2 then F=8
IF (A >= B) THEN ...
IF ((A < 2) && (B > 3)) THEN ...
IF ((C < 2) || (X > 4)) THEN ...
Notes
Expressions must be enclosed within parentheses ( ). Expressions are always evaluated from left to right within parentheses.
You should use parentheses to set precedence within an expression. When using the unary operators (logical NOT and bitwise
complement) on values, variables, expressions, etc. the values, variables, expressions, etc. must be in parentheses ( ).
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 21
OUTPUTS
Syntax
OUTPUTS <output pin>[, <output pin>, ...];
Description
Declares output pins (pins that drive or load the circuit). The OUTPUTS data type is used to define the pins which affect the
operation of circuitry external to the device. These generally include input, output, I/O and power pins. Input and power pins are
included in this list because their presence constitutes a load on the driving circuitry.
Parameters
<output pin> - Name of the output pin.
Examples
OUTPUTS VCC_LD, PRE_LD, DATA_LD, CLK_LD, CLR_LD, QN, Q;
Notes
Output pin names must begin with a letter and be defined before they are used.
PARAM_SET
Syntax
PARAM_SET(<param var>)
Description
The PARAM_SET function is used to determine if a parameter in the SimCode model definition has been set. It returns 1 if the
specified parameter was set (e.g., vil_param=0.8) otherwise it returns 0.
Parameters
<param var> - SimCode model definition parameter.
Examples
A = PARAM_SET(ld_param);
IF (PARAM_SET(voh_param)) THEN ...
Notes
See INTEGERS and REALS for a list of SimCode model definition parameters and their associated variable names.
PROMPT
Syntax
PROMPT("<message>"[, <value/pin>...]);
Description
The PROMPT statement is used to pause simulation and display the information specified by the <message> string. The
message is displayed in the status window during simulation. The user must click on a button to continue execution of the
SimCode.
Parameters
<message> - Message string including formatting characters as needed.
<value> - Variable or constant value.
<pin> - Pin name or index to pin variable.
Examples
PROMPT("input=%d time=%f device=%s", D1, t1, INSTANCE);
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 22
Notes
A format string in PROMPT is similar to a format that may be used in a printf statement in C. Valid formatting characters include
(but are not limited to):
\t tab
\n new line
\r carriage return
%d Decimal display for short variable or current input/output state.
%D Decimal display for short variable or old input/output state.
%x Hex display for short variable or current input/output state.
%X Hex display for short variable or old input/output state.
%c Character display for short variable or current input/output state.
%C Character display for short variable or old input/output state.
%e Exponential display for real variable.
%f Floating point engineering display for real variable.
%g Short display (%e or %f) for real variable.
%s String constant display.
The only valid string constants are:
INSTANCE The present SimCode device instance name.
FUNC The present SimCode device function name.
FILE The present SimCode device file name.
PWL_TABLE
Syntax
PWL_TABLE (<IN var>: <IN1>,<OUT1>,<IN2>,<OUT2>[,...<INn>,<OUTn>])
Description
This piece-wise-linear function is essentially a look-up table. The value of <IN var> is used to look up an entry in a table which
consists of pairs of values. The first value in each pair is an input compare value and the second value is the corresponding
output value. If the <IN var> value is less than the first <IN> value, the first <OUT> value is returned. If the <IN var> value is
greater than the last <INn> value, then the last <OUTn> value is returned. Linear interpolation is done between entries
according to the formula:
value = (((OUTA-OUTB)/(INA-INB))*(<IN var>-INA)+OUTA)
where <IN var> falls between the input compare values INA and INB. The actual output value will fall between output values
OUTA and OUTB.
Parameters
<IN var> - input variable (integer or real)
<INx> - input compare value
<OUTx> - output value at <INx>
Examples
twh = (PWL_TABLE(var: 5,180n,10,120n,15,80n));
In this example, if var = 10 then twh = 120n and if var = 12 then twh = 104.
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 23
Notes
Two or more IN/OUT data value pairs must be entered and the IN values must be entered in ascending order. There is no limit
to the maximum number of IN/OUT data pairs that can be entered.
PWR_GND_PINS
Syntax
PWR_GND_PINS (<pwrpin>, <gndpin>);
Description
The PWR_GND_PINS statement defines which of the input pins are power and ground and sets the Power and Ground
parameters of the device to absolute voltages as follows:
pwr_param = voltage on <pwrpin>
gnd_param = voltage on <gndpin>
Parameters
<pwrpin> - name of the power pin
<gndpin> - name of the ground pin
Examples
PWR_GND_PINS(VCC, GND);
Notes
This statement can only be used once in the SimCode. Only one pin can be defined for power and one for ground.
READ_DATA
Syntax
READ_DATA(<array>[, <array>, ...])
Description
The READ_DATA function opens the file specified by the "data=" parameter in the devices .MODEL statement (in the
intermediate linked model file *.mdl) and reads ASCII text data into one or more arrays. The number and type (integer/real) of
the values per line that will be read is based on the number and type of array variables that are specified in the function call. The
number of data lines read is determined by the number of data lines in the specified file and/or the size of the smallest array in
the function call.
The READ_DATA function returns the number of lines read. A negative number is returned if an error is encountered:
-1 Invalid file name
-2 Cant find file
-3 Invalid array
-4 Illegal array access
-5 Data type
-6 Expected data value
Parameters
<array> - Name of the array into which the value is placed.
Examples
MYDEVICE.MDL file:
.MODEL AMYDEVICE XSIMCODE(file="{MODEL_PATH}MYDEVICES.SCB"
+ func=MyDevice data="{MODEL_PATH}MYDEVICE.DAT" {mntymx})
MYDEVICE.DAT file:
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 24
8, 8E-6
9, 9E-6
10, 1E-5
11, 1.1E-5
MyDevice SimCode:
nlines = READ_DATA(int_array, real_array);
This example opens a filed called MYDEVICE.DAT. It reads 2 columns of data from the file where the first column contains
integer values and the second column contains real values. If the arrays are declared as int_array[3] and real_array[5] then only
the first 3 data lines will be read and nlines will be set to 3.
Notes
Multiple values per line in the data file must be separated by commas.
The real values in the data file must be in scientific notation.
The devices .MODEL statement which contains the data= parameter must be placed in the device symbols .MDL file.
REALS
Syntax
REALS <var>[, <var>, ...];
Description
The REALS data type is used to define real variables and arrays.
Parameters
<var> - name of the variable
Examples
REALS tplh_val, tphl_val, ricc_val, vbias, values[64];
Notes
Real variables and arrays must begin with a letter and be defined before they are used. Real arrays are defined by following the
array name with a left bracket ( [ ), an integer number which defines the size of the array, and a right bracket ( ] ). Real arrays
can be set and/or used in expressions.
The following are reserved SimCode real variables which do not need to be declared:

Variable Use Digital Model Parameter
vil_param low input state value VIL value
vih_param high input state value VIH value
vol_param low output state value VOL value
voh_param high output state value VOH value
v3s_param tri-state output state value N/A
rol_param low output strength value N/A
roh_param high output strength value N/A
r3s_param tri-state output strength value N/A
pwr_param voltage on power pin PWR value
gnd_param voltage on ground pin GND value
present_time present simulation time N/A
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 25
previous_time previous simulation time N/A
sim_temp circuit operating temperature N/A (SPICE Option: TEMP)
The Digital Model Parameter can be set independently for each digital device using the respective parameters found on the
Parameters tab of the Sim Model dialog. This dialog is accessed by double-clicking on the entry for the simulation model link in
the Models region of the associated Component Properties dialog. Entering a value for any of PWR, GND, VIL, VIH, VOL, and
VOH in the Sim Model dialog, will override any value specified by the SimCode model.
The values of pwr_param and gnd_param are set each time the PWR_GND_PINS statement is executed. The value of
present_time and previous_time are set each time the time step changes. The value of sim_temp is the current
operating temperature of the circuit which can be set from the SPICE Option TEMP.
RECOVER
Syntax
RECOVER(<clk input> = {LH}|{HL}
<mr input> [<mr input> ...]
{TREC=<time>}|{TRECL=<time> TRECH=<time>} ["<message>"];
Description
Tests inputs for recovery time violations. The RECOVER function compares the time difference between a level change (LH or
HL) on the <clk input> and a level change on the <mr input> to a specified test time. RECOVER test times are specified jointly
using TREC=<time> (which sets TRECL and TRECH to the same value) or individually using TRECL=<time> and TRECH=<time>.
If the compare time is less than the specified <time> a warning will be displayed during simulation. An optional <message>
string can be included in the RECOVER statement which will be output if a warning is displayed.
Parameters
<clk input> - Name of or index to the input clock/reference pin under test
<mr input> - Name of or index to the input set/reset pin under test.
TREC - Recovery time for both low and high going <mr pin>.
TRECL - Recovery time for low going <mr pin>.
TRECH - Recovery time for high going <mr pin>.
<time> - Specified test time.
<message> - Text string that will be displayed if a warning occurs.
Examples
RECOVER(CLK=LH PRE CLR TREC=trec_val
"CLK->PRE or CLR");
Notes
Data book specifications should be used with this function. TRECL=<time> and TRECH=<time> can be entered in the same
RECOVER test. The RECOVER test will be made only if the state of the <mr input> matches the time parameter (TRECL=LOW,
TRECH=HIGH) when the <clk input> makes the specified transition (LH or HL). For example, if <clk input>=LH and TRECL is
specified then the <mr input> must be LOW when the <clk input> goes from LOW to HIGH for a RECOVER test to be made.
Pin names and variables can be mixed in the same RECOVER statement.
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 26
RETURN
Syntax
RETURN
Description
Returns from a subroutine in the SimCode. The RETURN instruction is used to return program flow to the instruction that
followed the last GOSUB instruction.
SELECT_VALUE
Syntax
SELECT_VALUE (<index>: <val/pin/var>,<val/pin/var>[,<val/pin/var>,...]);
Description
Returns a value from a simple look-up table. The SELECT_VALUE function returns the value of the number or variable
indicated by the value of the index variable.
Parameters
<index> - input variable (index to <val/pin/var>)
<val/pin/var> - output value, pin or variable
Examples
A = (SELECT_VALUE(B: 16, 8, 4, 2, 1));
In this example, if B = 2 then A = 8 (the 2nd value).
Notes
The number of values and/or variables used is not limited.
SETUP_HOLD
Syntax
SETUP_HOLD(<clk input> = {LH}|{HL}
<data input> [<data input> ...]
{TS=<time>}|{TSL=<time> TSH=<time>}
{TH=<time>}|{THL=<time> THH=<time>} ["<message>"];
Description
Tests inputs for setup and hold time violations The SETUP_HOLD function compares the time difference between a level
change (LH or HL) on the <clk input> and a level change on the <data input> to a specified test time. SETUP test times are
specified jointly using TS=<time> (which sets TSL and TSH to the same value) or individually using TSL=<time> and
TSH=<time>. HOLD test times are specified jointly using TH=<time> (which sets THL and THH to the same value) or individually
using THL=<time> and THH=<time>. If the compare time is less than the specified <time> a WARNING will be displayed. An
optional <message> string can be included in a SETUP_HOLD statement which will be output if a WARNING is displayed.
Parameters
<clk input> - Name of or index to the input clock/reference pin under test.
<data input> - Name of or index to the input data pin under test.
TS - Setup time for both low and high going <data input>.
TSL - Setup time for low going <data input>.
TSH - Setup time for high going <data input>.
TH - Hold time for both low and high going <data input>.
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 27
THL - Hold time for high going <data input>.
THH - Hold time for low going <data input>.
<time> - Specified test time.
<message> - Text string that will be displayed if a warning occurs.
Examples
SETUP_HOLD(CLK=LH DATA Ts=ts_val Th=th_val "CLK->DATA");
Notes
Data book specifications should be used with this function. TSL=<time>, TSH=<time>, THL=<time> and THH=<time> can be
entered in the same SETUP_HOLD statement. The SETUP and/or HOLD test will be made only if the state of the <data input>
matches the time parameter (TSL or THL=LOW, TSH or THH=HIGH) when the <clk input> makes the specified transition (LH or
HL). For example, if <clk input>=LH and TSL is specified, then the <data input> must be LOW when the <clk input> goes from
LOW to HIGH for a SETUP test to be made.
Pin names and variables can be mixed in the same SETUP_HOLD statement.
STATE
Syntax 1
STATE <output> [<output>...] = (<expression>);
Syntax 2
STATE <output> [<output>...] = {ZERO}|{ONE}|{UNKNOWN};
Description
The state of an output pin is determined by its level and its strength. The STATE command sets the level and strength for one
or more output pins or variables. If <expression> is less than or equal to vol_param, the output will be set to ZERO. If
<expression> is greater than or equal to voh_param, the output will be set to ONE. Otherwise, the output will be set to
UNKNOWN. The level and strength values are set according to the state:
<expression> State Level Strength
<= vol_param ZERO vol_param rol_param
>= voh_param ONE voh_param roh_param
other UNKNOWN v3s_param r3s_param
Parameters
<output> - Name of, or variable index to, the output pin.
<expression> - Any expression to be compared to VOL or VOH.
Examples
STATE Q = ONE;
STATE Q1 Q2 Q3 Q4 = ZERO;
STATE OUT = ((1+2)/3);
In the last example, OUT will be:
ZERO if vol_param > 1
UNKNOWN if vol_param < 1 and voh_param > 1
ONE if voh_param < 1
Notes
Output pins can be specified by using the output pin name or by an integer variable that contains the index of an output pin. Pin
and variable names cannot be mixed in the same STATE command. References to outputs must be either all pin names or all
variable names.
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 28
STATE_BIT
Syntax
STATE_BIT <output> [<output> ...] = (<expression>);
Description
The state of an output pin is determined by its level and its strength. The STATE_BIT command is used to set the level and
strength for one or more output pins based on the value of the <expression>. The state of the first pin listed is set according to
the first (least-significant-bit) of the expression's value, the state of the second pin listed is set according to second bit of the
expression's value, and so on. The level and strength values are set by the bit's value:
Bit Value State Level Strength
0 ZERO vol_param rol_param
1 ONE voh_param roh_param
Parameters
<output> - name of or variable index to the output pin
<expression> - any expression which can be bitwise matched with the outputs
Examples
STATE_BIT Q1 Q2 Q3 Q4 = (internal_reg);
In this example, if internal_reg = 11 (1011 binary) then Q1 (LSB) = ONE, Q2 = ONE, Q3 = ZERO and Q4 (MSB) = ONE.
Notes
Output pins can be specified by using the output pin name or by an integer variable that contains the index of an output pin. Pin
and variable names cannot be mixed in the same STATE_BIT statement. References to outputs must be either all pin names or
all variable names.
The maximum number of output pins/vars is limited to 16.
STEP_OFF
Syntax
STEP_OFF
Description
Turns off the SimCode trace mode.
STEP_ON
Syntax
STEP_ON
Description
Turns on the SimCode trace mode. This causes the SimCode to display the Program Counter (PC) number and each SimCode
instruction before it is executed.
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 29
STRENGTH
Syntax 1
STRENGTH <output> [<output> ...] = (<expression>);
Syntax 2
STRENGTH <output> [<output> ...] = {STRONG}|{HI_IMPEDANCE};
Description
The state of an output pin is determined by its level and its strength. Use the STRENGTH command to set the strength of one or
more output pins.
Value State Strength
STRONG ZERO rol_param
STRONG ONE roh_param
HI_IMPEDANCE N/A r3s_param
<expression> N/A <expression>
Parameters
<output> - Name of or variable index to the output pin.
<expression> - Any expression to be used directly as a strength.
Notes
Output pins can be specified by using the output pin name or by an integer variable the contains the index of an output pin. Pin
and variable names cannot be mixed in the same STATE statement. References to outputs must be either all pin names or all
variable names.
SUPPLY_MIN_MAX
Syntax
SUPPLY_MIN_MAX(<min value>, <max value>);
Description
The SUPPLY_MIN_MAX function checks the voltage difference between the power and ground pins defined in
PWR_GND_PINS. If the WARN parameter is set to ON on the Parameters tab of the associated Sim Model dialog and the
voltage difference (pwr_param - gnd_param) is less than <min value> or greater than <max value> a warning will be displayed
during simulation.
Parameters
<min value> - Minimum recommended power supply voltage.
<max value> - Maximum recommended power supply voltage.
Examples
SUPPLY_MIN_MAX(4.75, 5.25);
Notes
Data book specifications should be used with this function. PWR_GND_PINS must be defined to use this function.
TABLE
Syntax
TABLE <line>
<input> [<input> ...] <output pin> [<output pin> ...]
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 30
<input state> [<input state> ...] <output state> [<output state> ...];
Description
The TABLE statement operates like a truth table to set the level and strength of the specified outputs.
Valid input states are:
0 low (input voltage is <= vil_param).
1 high (input voltage is >= vih_param).
X dont care what input voltage is.
Valid output states are:
L ZERO (set output level to vol_param)
H ONE (set output level to voh_param).
Z UNKNOWN (set output level to v3s_param).
Output state letters can be followed by a colon and a letter to indicate strength:
s STRONG (set output to rol_param for L and roh_param for H).
z HI_IMPEDANCE (set output to r3s_param).
If a strength character is not specified after an output state then STRONG will be used for L and H states and HI_IMPEDANCE
will be used for Z states.
Parameters
<line> - Variable into which the table line number is placed.
<input> - Name of the input pin or variable index to the input pin.
<output pin> - Name of the output pin.
<input state> - State of the individual inputs.
<output state> - State of the individual outputs based on input conditions.
Examples
TABLE tblIndex
INA INB OUT
0 0 H
0 1 H
1 0 H
1 1 L;

This example is representative of 1/4 of a 7400 2-input NAND gate. If input pins INA and INB are both high (>= vih_param),
OUT is set to ZERO (vol_param) and STRONG (rol_param) and tblIndex is set to 4.
Notes
Each row is tested sequentially from top to bottom until the input conditions are met. The outputs are set for the first row to meet
the input conditions. The <line> is set to the line number in the table that was used. If no match was made then <line> is set to
0.
Input pin and variable names cannot be mixed in the same TABLE statement. References to inputs must be either all pin
names or all variable names.
VALUE
Syntax
VALUE(<pin>)
Description
Returns the value of the specified pin. The VALUE function returns a real number that indicates the voltage level of the
specified pin.
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 31
Parameters
<pin> - Name of, or index to, a pin.
Examples
v = (VALUE(D3));
VIL_VIH_PERCENT
Syntax
VIL_VIH_PERCENT (<vil%>, <vih%>);
Description
VIL and VIH do not use a min/typ/max array to select their values, but must be declared explicitly for each digital device. The
VIL_VIH_PERCENT statement sets the VIL and VIH parameters of the device to a percentage of the supply voltage as follows:
vil_param = (pwr_param - gnd_param) * <vil%>
vih_param = (pwr_param - gnd_param) * <vih%>
Parameters
<vil %> - Percentage of the supply voltage which defines vil.
<vih %> - Percentage of the supply voltage which defines vih.
Examples
VIL_VIH_PERCENT(33, 67);
Notes
PWR_GND_PINS must be defined to use this function.
The % values must be greater than 0 and less than 100.
The vil_param and vih_param values set by VIL_VIH_PERCENT are overridden by any values set for the VIL value and VIH
value parameters on the Parameters tab of the associated Sim Model dialog (accessed by double-clicking on the entry for the
linked simulation model in the associated Component Properties dialog).
VIL_VIH_VALUE
Syntax
VIL_VIH_VALUE (<vil>, <vih>);
Description
VIL and VIH do not use a min/typ/max array to select their values, but must be declared explicitly for each digital device. The
VIL_VIH_VALUE statement sets the VIL and VIH parameters of the device to absolute voltages as follows:
vil_param = <vil>
vih_param = <vih>
Parameters
<vil> - Absolute voltage level which defines vil.
<vih> - Absolute voltage level which defines vih.
Examples
VIL_VIH_VALUE(1.25, 1.35);
Notes
In order to more accurately model the actual switching characteristics of a digital input, VIL and VIH are not generally set to their
specified data book values. The exception is the case of devices with a specified hysteresis such as the 74LS14. Typically, the
hysteresis of a digital device is small, in the order of 100mV, but never 0V.
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 32
The vil_param and vih_param values set by VIL_VIH_VALUE are overridden by any values set for the VIL value and VIH
value parameters on the Parameters tab of the associated Sim Model dialog (accessed by double-clicking on the entry for the
linked simulation model in the associated Component Properties dialog).
VOL_VOH_MIN
Syntax
VOL_VOH_MIN (<vol offset>, <voh offset>, <min voh-vol>);
Description
VOL and VOH do not use a min/typ/max array to select their values, but must be declared explicitly for each digital device. The
VOL_VOH_MIN statement sets the VOL and VOH parameters of the device as follows:
vol_param = gnd_param + <vol offset>
voh_param = pwr_param + <voh offset>
Parameters
<vol offset> - Voltage offset which must be applied to ground pin voltage to get vol.
<voh offset> - Voltage offset which must be applied to power pin voltage to get voh.
<min voh-vol> - Minimum allowed difference between voh and vol.
Examples
VOL_VOH_MIN(0.2, -0.4, 0.1);
In this example:
If gnd_param = 0V and pwr_param = 5.0V, then
vol_param = 0.2V and voh_param = 4.6V
If gnd_param = 0V and pwr_param = 0.5V, then
vol_param = 0V and voh_param = 0.1V
Notes
In order to more accurately model the actual characteristics of a digital output, VOH is not generally set to its specified data
book value. The reason for this deviation is that data book values for VOH are specified for maximum IOH load. In Digital
SimCode, VOL and VOH represent an unloaded output voltage.
PWR_GND_PINS must be defined to use this function.
The vol_param and voh_param values set by VOL_VOH_MIN are overridden by any values set for the VOL value and VOH
value parameters on the Parameters tab of the associated Sim Model dialog (accessed by double-clicking on the entry for the
linked simulation model in the associated Component Properties dialog). These are offset values rather than absolute voltages.
The <voh offset> is negative so that when added to pwr_param, the resulting VOH will not be greater than pwr_param. If the
difference between the resulting vol_param and voh_param is less than <min voh-vol>, then vol_param will be set to the value
of gnd_param and voh_param will be set to gnd_param + <min voh-vol>.
WHILE ... DO
Syntax
WHILE (<expression>) DO BEGIN ... END;
Description
The WHILE ... DO statement is used to loop through a section of SimCode until <expression> evaluates to false.
Parameters
<expression> - Any expression that can be evaluated as true or false
Examples
i = 1;
WHILE (i <= 5) DO
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 33
BEGIN
data[i] = data[i + 1];
i = i + 1;
END;
Notes
Program flow will remain in a loop between the BEGIN and END statements until <expression> evaluates to false, then program
flow resumes after the END statement.
WIDTH
Syntax
WIDTH(<input> [<input>...] {TWL=<time>}|{TWH=<time>} ["<message>"];
Description
The WIDTH function compares the pulse width on each <input> to the specified test WIDTH times. A low level test time is
specified using TWL=<time> while a high level test time is specified using TWH=<time>. If the compare time is less than the
specified <time> a WARNING will be displayed. An optional <message> string can be included in the WIDTH statement which
will be output if a WARNING is displayed.
Parameters
<input> - Name of or variable index to the input pin under test.
TWL - Width of a low going pulse.
TWH - Width of a high going pulse.
<message> - Text string that will be displayed if a warning occurs.
Examples
WIDTH(CLK TWL=clk_twl TWH=clk_twh "CLK");
WIDTH(PRE CLR TWL= pre_clr_twl "PRE or CLR");
Notes
Data book specifications should be used with this function. The input pins can be input pin names and/or integer variables that
contain an index value to an input pin. Pin names and variables can be mixed in the same WIDTH statement.
WIDTH_TIME
Syntax
WIDTH_TIME(<input>)
Description
This function returns a real value that indicates the last pulse width encountered on the specified <input>.
Parameters
<input> - Name of or index to an input pin.
Examples
PW = (WIDTH_TIME(CP2));
TR0117 Digital SimCode Reference

Version (v1.3) Mar 19, 2008 34
Revision History
Date Version No. Revision
01-Dec-2004 1.0 New product release
24-May-2005 1.1 Updated for SP4
09-Jun-2006 1.2 Updated for Altium Designer 6.3
19-Mar-2008 1.3 Updated Page Size to A4.
02-Aug-2011 - Updated template.
Software, hardware, documentation and related materials:
Copyright 2011 Altium Limited.
All rights reserved. You are permitted to print this document provided that (1) the use of such is for personal use only and will not be copied or
posted on any network computer or broadcast in any media, and (2) no modifications of the document is made. Unauthorized duplication, in
whole or part, of this document by any means, mechanical or electronic, including translation into another language, except for brief excerpts in
published reviews, is prohibited without the express written permission of Altium Limited. Unauthorized duplication of this work may also be
prohibited by local statute. Violators may be subject to both criminal and civil penalties, including fines and/or imprisonment.
Altium, Altium Designer, Board Insight, DXP, Innovation Station, LiveDesign, NanoBoard, NanoTalk, OpenBus, P-CAD, SimCode, Situs,
TASKING, and Topological Autorouting and their respective logos are trademarks or registered trademarks of Altium Limited or its subsidiaries.
All other registered or unregistered trademarks referenced herein are the property of their respective owners and no trademark rights to the
same are claimed.

S-ar putea să vă placă și