Sunteți pe pagina 1din 1

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
INPUT DATA
LATERAL FORCE ON DIAPHRAGM: v
dia, WIND
= 350 plf,for wind
v
dia, SEISMIC
= 350 plf,for seismic
GRAVITY LOADS ON THE ROOF: w
DL
= 262 plf,for dead load
w
LL
= 0 plf,for live load
DIMENSIONS: L
w
= 8 ft , h = 16 ft
L = 7 ft , h
p
= 0 ft
PANEL GRADE ( 0 or 1) = 1 <= Sheathing and Single-Floor
MINIMUM NOMINAL PANEL THICKNESS = 15/32 in
COMMON NAIL SIZE ( 0=6d, 1=8d, 2=10d ) 1 8d
SPECIFIC GRAVITY OF FRAMING MEMBERS 0.5
EDGE STUD SECTION 2 pcs, b = 2 in , h = 6 in
DESIGN SUMMARY
BLOCKED 15/32 SHEATHING WITH 8d COMMON NAILS
@ 4 in O.C. BOUNDARY & ALL EDGES / 12 in O.C. FIELD,
5/8 in DIA. x 10 in LONG ANCHOR BOLTS @ 34 in O.C.
HOLD-DOWN FORCES: T
L
= 4.02 k , T
R
= 3.87 k (USE PHD5-SDS3 SIMPSON HOLD-DOWN)
DRAG STRUT FORCES: F = -0.35 k
EDGE STUD: 2 - 2'' x 6'' DOUGLAS FIR-LARCH No. 1, CONTINUOUS FULL HEIGHT.
SHEAR WALL DEFLECTION: D = 0.97 in
ANALYSIS
THE MAX SHEAR WALL DIMENSION RATIO L / B = 2.0 < 2 [Satisfactory]
THE UNIT SHEAR FORCE v
b
= 306 plf, ( 1 Side Diaphragm Required, the Max. Nail Spacing = 4 in )
THE SHEAR CAPACITIES PER UBCTable 23-II-I-1 :
Min. Min.
Common PenetrationThickness
Nail (in) (in) 6 4 3 2
8d 1 1/2 15/32 260 380 490 640
Note: The indicated shear numbers have reduced by specific gravity factor per note 1 of the table.
THE DRAG STRUT FORCE: F

= (L-L
w
) MAX( v
dia, WIND
, W
0
v
dia, SEISMIC
) = -0.35 k ( W
0
= 1 ) (Sec. 1633.2.6)
THE MAX SPACING OF 5/8" DIA ANCHOR BOLT (Tab.11E, NDS 2001, Page 85) S = 34 in
THE HOLD-DOWN FORCES:
v
dia
Safty Holddown
(plf) Factors SIMPSON
Left 0.9 T
L
= 3922
Right 0.9 T
R
= 3716
Left 2/3 T
L
= 4024
Right 2/3 T
R
= 3871
THE MAXIMUM SHEAR WALL DEFLECTION: ( Section 4.3, ASD MANUAL SUUP, Page SW-17)
= 0.971 in
Where: v
b
= 306 plf L
w
= 8 ft E = 1.7E+06 psi
A = 16.50 in
2
h = 16 ft G = 9.0E+04 psi
t = 0.298 in e
n
= 0.037 in d
a
= 0.15 in
CHECK EDGE STUD CAPACITY
F
c
= 1500 psi C
D
= 1.6 C
P
= 0.14 A = 16.5 in
2
E = 1700 ksi C
F
= 1.10 F
c
'
= 365 psi > f
c
= 201 psi
[Satisfactory]
Techincal References:
1. "National Design Specification, NDS", 2001 Edition, AF&AP, AWC, 2001.
2. Alan Williams: "Structuiral Engineering Reference Manual", Professional Publications, Inc, 2001.
P
H
D
5
-
S
D
S
3
350
350
SEISMIC
WIND
12349
10515
12349
40838
39200
10515
205
Panel Grade
Wall Seismic
at mid-story (lbs)
Resisting
Moments (ft-lbs)
Net Uplift
(lbs)
Overturning
Moments (ft-lbs)
Shear Wall Design
Blocked Nail Spacing
Boundary & All Edges
Sheathing and Single-Floor
3
8
0.75
b b a
Bending Shear Nail slip Chord splice slip n
w w
h h
v h v d
h
e
EA Gt
L L
D=+++=+++
DDDD

S-ar putea să vă placă și