Sunteți pe pagina 1din 25

Connectivity Solutions

for Rockwell Automation

Industrial networking made easy!


fieldbus and industrial ethernet gateways - EMBEDDED CONNECTIVITY
WIRELESS SOLUTIONS - NETBITER REMOTE MANAGEMENT SOLUTIONS

Quick find:

Our brands

Your partner for industrial communication

About HMS Industrial Networks ............................................................................. 3


Anybus Communicator & Anybus X-gateway introduction ................................. 4,5

Device connectivity gateways Serial\CAN\ protocol conversion

Protocol conversion overview ..............................................................................6,7


Modbus RTU to EtherNet/IP, DeviceNet, ControlNet gateway...................................8
DF1 to EtherNet/IP, DeviceNet, ControlNet gateway ............................................9
CAN to EtherNet/IP, DeviceNet, ControlNet gateway ..............................................10
RS-232/422/485 to EtherNet/IP, DeviceNet, ControlNet gateway .....................11

Network to network connectivity gateways

Network to network connectivity overview .................................................... 12,13

Network gateways with a Master/Scanner interface

DeviceNet and EtherNet/IP to Fieldbus / Industrial Ethernet ............................ 14


CANopen Master to DeviceNet, ControlNet, EtherNet/IP ....................................... 15
PROFIBUS-DPV1 Master to DeviceNet, ControlNet, EtherNet/IP .............................. 16
Modbus-TCP Master to DeviceNet, ControlNet, EtherNet/IP .............................. 17

Network gateways with a Slave/Adapter interface

CANopen Slave to DeviceNet, ControlNet, EtherNet/IP ........................................ 18


CC-Link Slave to DeviceNet, ControlNet, EtherNet/IP ............................................ 19
ControlNet Adapter to Fieldbus / Industrial Ethernet ....................................... 20
DeviceNet Adapter to Fieldbus / Industrial Ethernet ......................................... 21
EtherNet/IP Adapter to Fieldbus / Industrial Ethernet ..................................... 22
EtherCAT Slave to DeviceNet, ControlNet, EtherNet/IP ........................................... 23
J1939 Slave to EtherNet/IP .................................................................................... 24
Modbus RTU Slave to DeviceNet, ControlNet, EtherNet/IP ..................................... 25
Modbus TCP Slave to DeviceNet, ControlNet, EtherNet/IP ................................. 26
PROFIBUS-DPV1 Slave to DeviceNet, ControlNet, EtherNet/IP .............................. 27
PROFINET-IO Slave to DeviceNet, ControlNet, EtherNet/IP .......................................28
PROFINET-IRT Slave to DeviceNet, ControlNet, EtherNet/IP .......................................29

Wireless gateway solutions

Wireless Gateway Overview .................................................................................. 30


Anybus Wireless Bridge - 802.11 WLAN / Bluetooth............................................... 31

Netbiter Remote Management monitoring and control solutions

Remote Management Overview ....................................................................... 32,33


Netbiter Argos features......................................................................................... 34
Netbiter EasyConnect connectivity gateways ........................................................ 35

Embedded interchangeable Fieldbus/Ethernet connectivity

Embedded Anybus Technology Overview ........................................................... 36,37


Anybus CompactCom Chip, Brick and Modules for CIP networks ........................ 38
Anybus-IC DIL-32 solutions .................................................................................. 39
Technical Information Embedded.......................................................................... 40
Technical Information Gateways ........................................................................ 41
Technical Information Remote Management..................................................... 42
Technical Support ................................................................................................. 43
Customer Case Stories ................................................................................ 44,45,46
Core values ........................................................................................................... 47

Industrial networking made easy

The Anybus range of products from HMS


is the worlds most used 3rd party product
range for industrial network connectivity.

HMS Industrial Networks is a leading global supplier of industrial


communication technology.
HMS provides network enabling solutions for Rockwell Automation products
such as Drives, I/Os, Power regulators and gateway solutions.

HMS helps solve many application needs


with a broad product offering.
The Anybus product family offers
stand-alone gateway solutions and
interchangeable embedded modules for
fieldbus and Ethernet.
Device and network to network gateways
Over 300 stand-alone gateways
solving almost any kind of industrial
communication connectivity problem.

Office Locations:

Sweden HQ, USA, Germany, Japan, China, UK, France, Italy, India, Denmark.
Distributors in 50 countries worldwide.

Encompass program

Embedded network solutions


Interchangeable Anybus embedded
solutions in different form factors, provide
a proven and trusted way to connect
industrial devices to all leading fieldbus
and industrial Ethernet networks.

Save time, save energy, save resources

Remote Management
A free, turn-key solution for remote
monitoring and control of industrial
applications: Netbiter streamlines
service operations and reduces energy
consumption.

HMS participates as an Encompass Product Partner in the Rockwell


Automation PartnerNetwork. Through Encompass Product Partners,
customers can quickly locate complementary products that best solve
any application challenges. These products are critical components or
connectivity solutions that extend and enhance Rockwell Automation
installations.

Flexible solutions for


your industrial market

Encompass - a rewarding
partnership

The industrial design of Anybus gateways


fitx all industrial networking needs,
regardless of industrial market.

HMS has been an active Encompass member for more

Automotive, factory automation, building


automation, food and beverage, mining, oil
and gas, water treatment and marine are
just some of the industrial segments where
Anybus gateways are used in conjunction
with many Rockwell Automation customer
applications today.

than 10 years. The Encompass program has been very


beneficial to HMS, not just as a way to get direct sales
from Rockwell Automation channels, but also as a
way to follow Rockwell Automation through the everchanging world of industrial automation. Being on the
road together with Rockwell Automation and talking to
our mutual customers have given us crucial feedback
about how our products perform in the field and how
we can improve them.
This has enabled us to develop a brand new generation
of HMS products which have been tailor-made to help
Rockwell Automation customers solve their connectivity
needs, now and in the future.

Kevin Knake
Executive Vice President
HMS America

Industrial networking made easy!

PROVEN AND TRUSTED INDUSTRIAL GATEWAYS USED BY LEADING


DEVICE MANUFACTURERS, SYSTEM INTEGRATORS AND END USERS

Limitless connectivity
Anybus gateways guarantee full Rockwell Automation/Allen Bradley PLC compatibility. Regardless if you are networking
your devices via a serial port, bridging between fieldbus networks or migrating to modern industrial Ethernet networks,
Anybus gateways include all the network combinations to solve your connectivity requirement.

Anybus communication gateways

Why choose an Anybus Gateway?

For over 20 years, Anybus gateways from HMS have successfully


integrated and connected devices, machines, networks and PLC
systems worldwide.

There are many companies today providing gateway solutions


for industrial network connectivity. Below are just some of the
reasons why Anybus gateways are unique:

Over 250 stand-alone gateways


solving almost any industrial network
connectivity requirement

Anybus Communicator and


Anybus X-gateway- proven
and trusted!

Proven and trusted to enhance and


extend the Rockwell Automation solution

Over 250 individual off-the-shelf gateways are available to help


solve almost any kind of industrial communication connectivity
problem. All versions are very easy to configure, requiring no
programming skills.

Get up and running quickly, using


pre-defined configurations
No programming or PLC function blocks
needed

Reliability, performance and ease of use have made Anybus


Communicator and Anybus X-gateway the leading gateway
choices within device and system integration.

Enable a seamless flow of information


within the CIP architecture

Anybus gateways help streamline network infrastructures


through easy system and device integration, thus helping to
reduce the overall cost of ownership within the entire plant.

No restrictions to physical location and


no PLC rack space needed

Flexible and versatile - integration gateways regardless of the


industrial market

Industrial strength

Anybus gateways with their industrial design are the perfect choice for all industrial networking needs, regardless of industrial
market. Automotive, factory automation, building automation, food and beverage, mining, oil and gas, water treatment and
marine are just some of the industrial segments where Anybus gateways are used today.

Anybus gateways are designed for harsh industrial


environments and are certified to leading industry
standards.

HAZ.LOC

Reductions to cost of ownership


through high production volumes,
reduced cabling and elimination of 3rd
party accessories
Included in Integrated Architecture
Builder
Included in Rockwell Automation
TECHConnect support database

Page 4
Industrial networking made easy!

www.anybus.com

Page 5
Industrial networking made easy!

www.anybus.com

Anybus Communicator - Protocol converter gateways

Anybus Communicator - Protocol converter gateways

Device connectivity through the Anybus Communicator

Protocol converters are needed to fill the communication gap

Common device protocols such as Modbus-RTU, DF1, CAN, or ASCII are often used when connecting a non-networked
industrial device to a PLC system and its fieldbus or industrial Ethernet network. To allow these devices to participate on an
Industrial Network, a gateway (protocol converter) can be used.

An Anybus Communicator gateway can be used to fill this communication gap. A complete family of gateway/protocol
converters that connect any industrial device to all leading fieldbus or Industrial Ethernet networks.
No PLC function blocks, no programming required!

Enabling devices with a Modbus RTU and DF1 via RS-232/422/485

Enabling devices with a configurable CAN based interface

Allen Bradley
PLC5

ControlLogix PLC

Anybus Communicator
Protocol converter

Anybus Communicator
Protocol converter

Allen Bradley
PLC 5

DF1
via e.g RS-232

CONTROLNET NETWORK
ETHERNET/IP NETWORK

DF1
via e.g RS-232
PowerFlex Drive
and motor

Modbus RTU
via e.g RS-232

Configurable
CAN based
protocol

Modbus RTU
Multi-drop via RS-485

Multi-drop CAN based


up to

Configurable
CAN based
protocol

Drive and motor

Kinnectic 3
servo drive

Bar code scanner


Relays
Weight scale

Free and Included configuration software for all protocol types

Enabling devices with a configurable RS-232/422/485 interface


CompactLogix PLC

Anybus Configuration Manager


The WindowsTM based Anybus Configuration Manager
supports ControlNet, DeviceNet and EtherNet/IP versions of
the Anybus Communicator.

Anybus Communicator
Protocol converter


DEVICENET NETWORK

DF1
Configurable Custom
Query/Response
Protocol via RS-232

Configurable Custom
Produce/Consume
Protocol via RS-422
Barcode scanner

Custom ASCII based


protocol via RS-232
Weight scale

Configures protocols such as Modbus RTU, DF1, ASCII or


customer specific produce/consume or query/response
protocols
Save/Load function means a completed configuration
can be re-used for many other installations
Password protection prevents unauthorized upload and
download of configurations
Ability to make popular checksum calculations
Built-in line listener with test functions

Anybus Configuration Manager CAN


The WindowsTM based Anybus Configuration Manager
CAN provides you with a flexible and easy-to-use CAN
frame-building environment with several ready-made CAN
functions. The software supports ControlNet, DeviceNet and
EtherNet/IP versions of the Anybus Communicator CAN.






Page 6
Industrial networking made easy!

www.anybus.com

Graphical CAN frame building support using several


ready-made CAN functions
Configures any CAN 2.0A or 2.0B based protocol
(11 and 29 bit identifiers)
Configures up to 128 transactions containing a total of
256 CAN frames
Save/Load function means a completed configuration
can be re-used for many other installations
Password protection prevents unauthorized upload and
download of configurations
Monitor/Modify function of process I/O data informing
of CAN transaction status
Diagnostic transaction Live List in the network I/O
informing of CAN transaction status

Page 7
Industrial networking made easy!

www.anybus.com

Anybus Communicator - Protocol converter gateways

Anybus Communicator - Protocol converter gateways

Anybus Communicator RTU

Anybus Communicator DF1

Converting from Modbus RTU protocols to ControlNet,


DeviceNet and EtherNet/IP

Converting from DF1 protocols to ControlNet,


DeviceNet and EtherNet/IP

With the Anybus Communicator RTU you can connect a


non-networked device to any major fieldbus or industrial
Ethernet network. The Communicator handles the
complete Modbus-RTU serial protocol without the need for
extensive PLC function blocks.
The Communicator RTU has a selectable serial
RS-232/422/485 interface making it possible to connect
one or multiple devices using just one Communicator.
This compact gateway consumes very little space in a
cabinet and is easily mounted on a standard
DIN rail.

APPLICATION EXAMPLE SINGLE-DROP

Integrates non-networked devices


and machines with a serial
RS-232/422/485 interface to a
DeviceNet/ControlNet or
EtherNet/IP PLC control system.

APPLICATION EXAMPLE MULTI-DROP

CompactLogix
DeviceNet Network

ControlLogix
Communicator RTU
DeviceNet

EtherNet/IP Network

Communicator RTU
EtherNet/IP

Configuration

As the most common serial


Modbus RTU interface is used, HMS
takes away the hassle of scripting
and serial frame-building by using
an easy 6-step visual configuration
wizard that contains predefined
Modbus RTU commands.

Proven and trusted

Modbus RTU
via RS-232
Example: Kinetic 3 servo drive with
a serial Modbus RTU interface

Example: Connects up to 31 PF4 drives via RS-485

The Anybus Communicator has


been safely connecting devices to
Rockwell Automation networks
and systems for over 10 years.

Features and benefits

Its flexibility means that it is used


in a wide variety of industries such
as factory automation, mining,
waste water management,
Infrastructure Building and HVAC
and many more.
With the Anybus Communicator,
your devices are connected fast. Its
unrivalled performance, flexiblity
and reliability gives you the peace
of mind you need
when solving
your connectivity
problems.
Niklas Selander
Product Manager Anybus Gateways

Modbus RTU via RS-485/422

When converting the Modbus RTU protocol, the


Communicator acts as Master on the serial network

Predefined 6-step Modbus RTU configuration wizard

Enables any automation device with a serial RS-232/422/485


Modbus RTU Slave interface to participate on a network

No hardware or software changes are required for the


connected automation device

Compatible with all Allen Bradley and Guard PLCs

Complete protocol conversion performed by the


Communicator, no PLC function blocks required

Save/Load function means a completed configuration can be


reused for many other installations

CE, RoHS, UL, cUL and Haz.Loc certifications

Global free technical support and consultancy

Configuration video available on www.anybus.com

Using the Rockwell Automation Integrated


Architecture Builder (IAB), engineers can integrate
the Communicator making it easy to include in your
network system design.

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Communications adapter, profile
n. 12

DeviceNet

1 = 5*5.08 PLUG 2 = 125-500 kbit/s


3 = 512 byte IN/OUT
4 = Communications adapter, profile
n. 12

EtherNet/IP

1 = RJ45 2 = 10/100 Mbit/s


3 = 512 IN/OUT
4 = EtherNet/IP group 2 and 3 server

Order information
Network: PartNo:
ControlNet AB7006
DeviceNet AB7001
EtherNet/IP AB7007

When to use

APPLICATION EXAMPLE SINGLE-DROP

Integrates non-networked devices


and machines with a serial
RS-232/422/485 interface to a
DeviceNet/ControlNet or
EtherNet/IP PLC control system.

APPLICATION EXAMPLE MULTI-DROP

CompactLogix
EtherNet/IP Network

HMS takes away the hassle


of scripting and serial frame
building by using an easy visual
configuration that allows for the
easy generation of DF1 scan lists.

ControlLogix
Communicator
EtherNet/IP

Example: Allen Bradley SLC500


with a serial DF1 interface
Example: Connecting PLC5s via RS-485

Features and benefits


When converting the DF1 protocol the Communicator acts


as a DF1 Half Duplex Master on the serial network

Furthermore, as the
Communicator is not restricted
to the length of a serial cable, it
can be installed almost anywhere
within the installation.

Enables any automation device with a serial RS-232/422/485


DF1 interface to participate on a network

No hardware or software changes are required for the


connected automation device

Compatible with all Allen Bradley and Guard PLCs

Complete protocol conversion performed by the


Communicator, no PLC function blocks required

With its intelligent internal


data mapping system, the
Communicator enables even very
slow devices to participate on the
network without any performance
restrictions.

Save/Load function means a completed configuration can be


re-used for many other installations

CE, RoHS, UL, cUL and Haz.Loc certifications

Global free technical support and consultancy

Configuration video available on www.anybus.com

*See page 41 for mechanical and technical


specifications

Optional accessories

USB-RS232 configuration adapter


Part No: 019570

Page 8
Industrial networking made easy!

www.anybus.com

DF1 RS-485/422

DF1 via RS-232

Tech Tip

Using the Communicator


to connect to serial devices
eliminates the need for a serial
option card and the need
for complex function block
programming.

Communicator
ControlNet

ControlNet Network

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Comm adapter, profile n. 12

DeviceNet

1 = 5*5.08 PLUG 2 = 125-500 kbit/s


3 = 512 byte IN/OUT
4 = Communications adapter,
profile n. 12

EtherNet/IP

1 = RJ45 2 = 10/100 Mbit/s


3 = 512 IN/OUT
4 = EtherNet/IP group 2 and 3 server

Order information
Network: PartNo:
ControlNet AB7006
DeviceNet AB7001
EtherNet/IP AB7007

*See page 41 for mechanical and technical


specifications

Using the Rockwell Automation Integrated


Architecture Builder (IAB), engineers can integrate
the Communicator making it easy to include in your
network system design.

Optional accessories

USB-RS232 configuration adapter


Part No: 019570

Page 9
Industrial networking made easy!

www.anybus.com

PROTOCOL CONVERTER GATEWAYS

When to use

The Communicator DF1 is used to enable nonnetworked automation devices to participate on


DeviceNet, ControlNet or EtherNet/IP.
With its selectable serial RS-232/422/485 interface, the
Communicator converts the DF1 protocol and enables
devices such as Rockwell Automation/Allen Bradley
PLC-5 and SLC-500 among others, to participate on the
network without the need for extensive PLC
function blocks.

Anybus Communicator - Protocol converter gateways

Anybus Communicator - Protocol converter gateways

Anybus Communicator RS-232/422/485

Anybus Communicator CAN

Converting from RS-232/422/485 protocols to ControlNet,


DeviceNet and EtherNet/IP

Converting from CAN-based protocols to ControlNet,


DeviceNet and EtherNet/IP

With the Anybus Communicator RS-232/422/485


you can connect your non-networked device to any
major fieldbus or industrial Ethernet network. The
Communicator handles the complete serial protocol
without the need for extensive PLC function blocks.

The Anybus Communicator CAN allows almost any CAN


device supporting an 11-bit or 29-bit identifier to be easily
integrated into a Rockwell Automation control system.
The Anybus Communicator CAN performs an intelligent
conversion between a CAN-based protocol of an
automation device and the chosen DeviceNet, ControlNet
or EtherNet/IP network. The Communicator CAN is a
compact gateway that consumes very little space in a
switching cabinet and is easily mounted onto a
standard DIN rail.

When to use

APPLICATION EXAMPLE SINGLE-DROP

Integrate non-networked devices


and machines using a configurable
serial RS-232/422/485 interface to
a DeviceNet/ControlNet or
EtherNet/IP PLC control system.

APPLICATION EXAMPLE MULTI-DROP

CompactLogix
DeviceNet Network

ControlLogix
Communicator RTU
DeviceNet

EtherNet/IP Network

Communicator RTU
EtherNet/IP

Protocol configuration

For industrial devices with a serial


RS-232/422/485 interface, HMS
makes it possible to configure
almost any Produce/Consume,
Request/Response or simple ASCII
protocols with its flexible serial
frame building method.

ASCII
via RS-232
Industrial machine connected via a
custom ASCII based RS-232 protocol

Barcode scanners connected via RS-485 using a custom


produce/consume protocol

Did you know?

Using the Anybus


Communicator
together with
the HMS M-Bus
converter allows
data from
measuring devices
onto DeviceNet, ControlNet or
EtherNet/IP.
M-Bus (Meter-Bus) is a standard
for remote reading of measuring
devices. It is predominantly
used in buildings, for example in
electricity meters, gas meters,
water meters or other types of
consumption meters.
*M-Bus converter sold separately, visit
www.anybus.com for more information

Custom protocol via RS-485/422

Build your own RS-232/422/485-based protocol in a


graphical environment in just a few minutes
Proven and trusted intelligent gateways providing unrivalled
flexibility and functionality
No hardware or software changes are required for the
connected automation device
Compatible with all PLCs from Rockwell Automation and
with other manufacturers such as Siemens, Schneider,
Mitsubishi etc

Complete protocol conversion performed by the


Communicator, no PLC function blocks required

Save/Load function means a completed configuration can be


reused for many other installations

Free global technical support and consultancy

CE, RoHS, UL, cUL and Haz.Loc certifications

Global free technical support and consultancy

Configuration video available on www.anybus.com


Using the Rockwell Automation Integrated
Architecture Builder (IAB), engineers can integrate
the Communicator making it easy to include in your
network system design.

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Communications adapter, profile
n. 12

DeviceNet

1 = 5*5.08 PLUG 2 = 125-500 kbit/s


3 = 512 byte IN/OUT
4 = Communications adapter, profile
n. 12

EtherNet/IP

1 = RJ45 2 = 10/100 Mbit/s


3 = 512 IN/OUT
4 = EtherNet/IP group 2 and 3 server

Order information
Network: PartNo:
ControlNet AB7006
DeviceNet AB7001
EtherNet/IP AB7007

*See page 41 for mechanical and technical


specifications

Optional accessories

USB-RS232 configuration adapter


Part No: 019570

Page 10
Industrial networking made easy!

www.anybus.com

When to use

APPLICATION EXAMPLE SINGLE-DROP

Generic CAN has traditionally


been used with sensors, barcode
readers and drives within the
European car manufacturing
industry.

ControlLogix
EtherNet/IP Network
Communicator CAN for EtherNet/IP
supporting dual-port Ethernet eliminating
the need for an external switch

Many of these devices have


fieldbus support for PROFIBUS or
CANopen. In addition they also
have a generic CAN port. Through
this port these devices can be
integrated with a DeviceNet/
ControlNet or EtherNet/IP PLC
control system.

Protocol configuration

Configuring CAN-based protocols


can be quite tricky. With the
Anybus Configuration Manager
CAN, HMS provides you with a
flexible and easy-to-use CAN frame
building environment with several
built-in CAN functions.
The configuration manager allows
for a mixture of both Query/
Response and/or Produce/
Consume protocols to be
configured.

Did you know?

With Anybus Communicator CAN


it is possible to configure the CAN
protocol SAE J1939. J1939 is often
used in the marine industry.

Configurable CAN network

Connects one or multiple devices

CAN gateways that connect CAN devices to fieldbus/


Ethernet networks

Support for custom CAN 1.0, 2.0A and 2.0B protocols

Handles mixed Produce/Consume and Request/Response


protocols and transactions

No hardware or software changes needed to your devices

No PLC code or function blocks required

Compatible with all PLCs from Rockwell Automation and

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 512 byte IN/OUT
4 = Comm adapter, profile n.12

DeviceNet

1 = 5*5.08 PLUG 2 = 125-500 kbit/s


3 = 512 byte IN/OUT
4 = Communications adapter,
profile n.12

EtherNet/IP

1 = RJ45 2 = 10/100 Mbit/s


3 = 507 byte IN/OUT
4 = EIP group 2+3, DLR support

with other manufacturers such as Siemens, Schneider,


Mitsubishi etc

Versions with Dual Port switched Ethernet allows for daisy


chaining and eliminates the need for external switches

Anybus Configuration Manager included for easy visual CAN


frame building

CE, RoHS, UL, cUL, ATEX and Haz.Loc certifications

Configuration video available on www.anybus.com

Global free technical support and consultancy


Using the Rockwell Automation Integrated
Architecture Builder (IAB), engineers can integrate
the Communicator making it easy to include in your
network system design.

Order information
Network:
Part No:
EtherNet/IP
ControlNet
DeviceNet

AB7318
AB7314
AB7313

*See page 41 for mechanical and technical


specifications

Optional accessories

USB-RS232 configuration adapter


Part No: 019570

Page 11
Industrial networking made easy!

www.anybus.com

PROTOCOL CONVERTER GATEWAYS

It supports RS-232/422/485 making it possible to


connect one or multiple devices using one Communicator.
This compact gateway consumes very little space in
a switching cabinet and is easily mounted on
a standard DIN rail.

Anybus X-gateway - Network to network gateways

Anybus X-gateway - Network to network gateways

Network to Network connectivity with Anybus X-gateway

Over 250 versions available solving any connectivity problem

Anybus X-gateways are a certified and proven industrial gateway family connecting almost any two industrial networks. Over 250
versions available, all very easy to configure and install. No extra programming required!

The X-gateways help system integrators to easily interconnect any two networks, enabling consistent information flow
throughout the entire plant. X-gateways are designed for use in industrial automation plants where many different networks
are used.

Fieldbus to EtherNet/IP migration projects

Replacement for parallel I/O wiring projects

Some examples that show how devices on a PROFIBUS or CANopen network can be seamlessly integrated within the CIP architecture
and a Rockwell Automation PLC control system running EtherNet/IP.

Anybus X-gateways serve as natural replacements to existing parallel wiring installations between I/O blocks used to bridge
data between two different networks. X-gateways increase the I/O data capacity and eliminate the need for two I/O blocks,
wiring time and cabling. A Master interface included in an X-gateway also eliminates the need for an additional PLC master.

ControlLogix PLC
EtherNet/IP Scanner
EtherNet/IP Network
Anybus X-gateway
Interface 1: EtherNet/IP Adapter
Interface 2: PROFIBUS Master

Anybus X-gateway
Interface 1: EtherNet/IP Adapter
Interface 2: CANopen Master

Slaves on a CANopen Network

Slaves on a PROFIBUS Network

I/O Block

Slaves on a PROFIBUS Network

I/O Block

Anybus X-gateway
Interface 1: EtherNet/IP Adapter
Interface 2: PROFIBUS Master

Slaves on a PROFIBUS Network

Connecting Rockwell Automation systems to other PLC systems

Configuration software included, no programming required!

Ethernet networks such as PROFINET and Modbus TCP can easily be integrated within a CIP architecture. In this case with a
MicroLogix PLC running DeviceNet. The use of Modbus TCP PLC Client (Master) is not required.

Anybus X-gateway Configuration (Adapter/Slave to Adapter/Slave versions)


For Adapter/Slave to Adapter/Slave versions, configuration is made via the built-in serial interface. For this purpose, a PC with an
installed terminal program (for example Windows Hyper Terminal) can be connected via a serial RS-232 cable to the configuration
port of the X-gateway. A terminal editor program is available for download at www.anybus.com. The easy-to-use configuration
interface allows you to define the I/O data sizes on each network side and to define the data mapping and separation between cyclic
I/O data and parameter data.

MicroLogix PLC
DeviceNet Scanner
DeviceNet Network

Anybus X-gateway
Interface 1: DeviceNet Adapter
Interface 2: Modbus TCP Client
(Master)

Anybus X-gateway
Interface 1: DeviceNet Adapter
Interface 2: PROFINET Slave

Anybus X-gateway Configuration (CIP networks to Modbus TCP Master)


X-gateway configuration is made over Ethernet via a built-in web page. The configuration page is used to configure Ethernet TCP/IP
settings, Modbus TCP client configuration and I/O data register mapping between Modbus TCP and the chosen network. The uplink
fieldbus or Ethernet slave interface to the PLC is configured with a standard device description file (EDS) in the PLC engineering tool.

Slaves on a Modbus TCP Network

Slaves on a PROFINET Network

Anybus X-gateway Configuration (CIP networks to CANopen Master)


X-gateway versions with a CANopen Manager (Master) interface can be configured with the free and included CANopen
Configuration Manager. A PC connects to the CANopen network via a USB-CAN adapter. In addition, any standard CANopen
configuration tool can be used to configure the CANopen interface. The uplink fieldbus or Ethernet Slave interface is configured with
a standard device description file (EDS) and RSNetworx.

S7 PLC
PROFINET
Master

Page 12
Industrial networking made easy!

Anybus X-gateway Configuration (DeviceNet and EtherNet/IP Scanner and PROFIBUS Master versions)
When using an X-gateway with a DeviceNet or EtherNet/IP Scanner/Master versions, Slave/Adapter configuration can be made either
via RSNetworx or with the included Anybus NetTool software. PROFIBUS Master and Slave configuration is made by the NetTool-PB
version also included free of charge. Anybus NetTool contains all necessary documentation and configuration cables.

www.anybus.com

Page 13
Industrial networking made easy!

www.anybus.com

Anybus X-gateway - Network to network gateways

Anybus X-gateway - Network to network gateways

DeviceNet & EtherNet/IP Scanner


connectivity to Fieldbus and Ethernet

CANopen Master connectivity to


ControlNet, DeviceNet & EtherNet/IP

Connecting CIP devices to any other Fieldbus and


Industrial Ethernet network and PLC system

Connecting a CANopen network to a Rockwell


Automation PLC system

These Anybus X-gateways are bridges between a nonCIP PLC system (Siemens, Schneider, Mitsubishi etc)
and Rockwell Automation devices with a DeviceNet or
EtherNet/IP interface.

The X-gateway CANopen series provides CANopen


Master (Manager) /Slave connectivity to a Rockwell
Automation PLC system with ControlNet, DeviceNet or
EtherNet/IP.

The X-gateway copies cyclic I/O data in both directions


enabling data exchange between networks. This
ensures a consistent information flow throughout
the entire plant.

The fact that Anybus X-gateways combine high


reliability and flexibility make them indispensible
connectivity tools for system integrators and plant
operators within all industries.

When to use

Integrating Rockwell Automation


devices (eg. drives) on DeviceNet
or EtherNet/IP to another network
and PLC system.

When to use

S7 PLC
PROFINET Network

Utilizing the Scanner interface on


the X-gateway means a Rockwell
Automation PLC and RSNetworx
is not required. This can be of
benefit when winning a contract
to retro-fit an existing (nonCIP) installation with Rockwell
Automation devices.

Anybus X-gateway
Interface 1: PROFINET Slave
Interface 2: DeviceNet Scanner
Mixed Rockwell Automation devices on a DeviceNet Network

Order information
DeviceNet Scanner: Part.No
CANopen Slave
CC-Link Slave
EtherCAT Slave
Modbus RTU Slave
Modbus TCP Slave
PROFIBUS Slave
PROFINET IO Device

AB7816
AB7819
AB7697
AB7817
AB7630
AB7663
AB7647

EtherNet/IP Scanner: Part.No


CANopen Slave
CC-Link Slave
EtherCAT Slave
Modbus RTU Slave
Modbus TCP Slave
PROFIBUS Slave
PROFINET IO Device

AB7677
AB7680
AB7699
AB7678
AB7669
AB7671
AB7670

Anybus X-gateway
Interface 1: EtherNet/IP Adapter
Interface 2: CANopen Master

Coupling/De-coupling different
parts of a machine or extending
the physical network distance
within an installation.

Devices (slaves) on an CANopen Network

The X-gateway CANopen can be


configured with the free and
included CANopen Configuration
Manager.
* See page 13 for more information

The X-gateway consists of two communication interfaces. The


first interface provides Scanner functionality controlling up to 63
DeviceNet and EtherNet/IP adapters. The second Adapter/Slave
interface can support any one of 12 other industrial networks.

An easy way to transmit I/O data between a ControlNet,


DeviceNet or EtherNet/IP network and all other major
fieldbus and Ethernet networks

Allows for cyclic I/O data exchange between networks

Fast I/O data transfer with average timing between


networks: 10-15 ms

Additional parameter data supported (depending on


network combination)

Optional control and status information added to the I/O


data for diagnostic purposes

Included Anybus OPC server for extended functionality


available with the EtherNet/IP version

Included IT functions such as integrated web server, email


and FTP client

Robust stand-alone metal housing with HazLoc, ATEX, CE


and RoHS certifications

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other


5 = Amount of slaves / adapters

DeviceNet

EtherNet/IP

1 = 5*5.08 PLUG 2 = 125-500 kbit/s


3 = 512 byte IN/OUT
4 = ODVA 2.0 Scanner Group 2
Client/Server / UCMM support
5 = 63 adapter/slaves
1 = RJ45 2 = 10/100 Mbit/s
3 = 512 byte IN/OUT
4 = EIP group 2+3, DLR support, IT
functions
5 = 63 adapter/slaves

*See page 41 for mechanical and technical


specifications

Using the Rockwell


Automation Integrated
Architecture Builder (IAB),
engineers can integrate
the X-gateway making it easy to
include in your network system
design.

Page 14
Industrial networking made easy!

www.anybus.com

Order information
Network:
Part No:
ControlNet
DeviceNet
EtherNet/IP 2-port

AB7303
AB7302
AB7306

Optional accessories

CANopen-to-USB configuration
adapter. Part.No: 021370
*CAN Configuration Manager available for
download at www.anybus.com

The X-gateway consists of two communication interfaces. The


first interface provides CANopen Master or Slave functionality.
The second interface provides ControlNet, DeviceNet or
EtherNet/IP Adapter functionality.

Allows transparent transfer of I/O data between CANopen


and another network

CANopen master functionality allows connection of up to


126 CANopen Slaves

Dual port Ethernet with switch functionality for EtherNet/IP


with DLR support

Ethernet versions with IT functions such as dynamic web


server, supporting downloadable customer specific web
pages

CANopen NMT Master and Configuration Manager


functionality

DIN-rail mountable slimline plastic housing with HazLoc,


ATEX, CE and RoHS certifications
Using the Rockwell Automation Integrated
Architecture Builder (IAB), engineers can integrate
the X-gateway making it easy to include in your
network system design.

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other


5 = Amount of slaves / adapters

CANopen
Master

1 = DSUB9M
2 = Up to 1 Mbit/s,
3 = 128 PDOs Receive/128 PDOs
Transmit, 510 bytes IN/OUT
4 = CANopen specification DS301
v4.0.2
5 = 126 slaves

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 512 byte IN/OUT
4 = Comm adapter, profile n.12

DeviceNet

1 = 5*5.08 PLUG 2 = 125-500 kbit/s


3 = 512 byte IN/OUT
4 = Communications adapter,
profile n.12

EtherNet/IP

1 = 2x RJ45 2 = 10/100 Mbit/s


3 = 507 byte IN/OUT
4 = EIP group 2+3, DLR support

*See page 41 for mechanical and technical


specifications

Page 15
Industrial networking made easy!

www.anybus.com

NETWORK TO NETWORK GATEWAYS

* See page 13 for more information

EtherNet/IP Network

Configuration

Configuration

EtherNet/IP Adapter setup via an


on-board web interface and
DeviceNet Adapter setup via the
included NetTool-DN config tool.

ControlLogix PLC
EtherNet/IP Scanner

Integrates Rockwell Automation


devices to other PLC systems with
a CANopen network.

Anybus X-gateway - Network to network gateways

Anybus X-gateway - Network to network gateways

Modbus TCP Master connectivity to


ControlNet, DeviceNet & EtherNet/IP

PROFIBUS Master connectivity to


ControlNet, DeviceNet & EtherNet/IP

Connecting a Modbus TCP network to a Rockwell


Automation PLC system

Connecting a PROFIBUS network to a Rockwell


Automation PLC system

The Anybus X-gateway Modbus TCP series are bridges


between a Modbus-TCP network and a Rockwell
Automation PLC system with ControlNet, DeviceNet or
EtherNet/IP.

This Anybus X-gateway is a bridge between a PROFIBUS


network and a Rockwell Automation PLC system with
ControlNet, DeviceNet or EtherNet/IP.
The X-gateway copies cyclic I/O data in both directions
enabling data exchange between networks. This
ensures a consistent information flow throughout
the entire plant.

The X-gateway copies cyclic I/O data in both directions


enabling data exchange between networks. This
ensures a consistent information flow throughout
the entire plant.
When to use

Anybus X-gateway
Interface 1: DeviceNet Adapter
Interface 2: Modbus TCP Client (Master)
Relays (slaves) on a Modbus TCP Network

Configuration

* See page 13 for more information

Tech Tip

The X-gateway consists of two communication interfaces.


The first interface provides Modbus TCP Client (Master)
functionality controlling up to 126 Modbus TCP Slaves. The
second interface provides ControlNet, DeviceNet or EtherNet/IP
Adapter functionality.

Allows for fast transparent transfer of I/O data between two


networks.

High performance and short throughput delay,


approximately 5 ms

If required, field replacement


can be made by simply moving
the memory card without
connecting a PC and with no
specialist help.

SD memory card slot for backup, configuration and Easy


Replacement

AB9003
AB9002
AB9006

SD memory card, industrial grade


Part No: 021530

Migrate from PROFIBUS to


Industrial Ethernet (EtherNet/IP).

EtherNet/IP Network

Anybus X-gateway
Interface 1: EtherNet/IP Adapter
Interface 2: PROFIBUS DPV1 Master

Coupling/De-coupling different
parts of a machine or extending
the physical network distance
within an installation.

Drives (slaves) on an PROFIBUS Network

Configuration

The X-gateway is equipped with an


SD memory card slot for Easy
Replacement, configuration copy
and backup.

Order information
Network:
Part No:

ControlLogix PLC
EtherNet/IP Scanner

Dual Port switched Ethernet allows daisy chaining on the


Modbus TCP ans EtherNet/IP network
Robust design for optimized cabling, DIN-rail or wall mount
options

Easy web based configuration tool. No programming or


scripting required

Live list which provides information to the uplink PLC about


the status of connected Modbus-TCP server devices and
configured transactions
Using the Rockwell Automation Integrated
Architecture Builder (IAB), engineers can integrate
the X-gateway making it easy to include in your
network system design.

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other


5 = Amount of slaves / adapters

Modbus
TCP

1=
2=
3=
4=

2*RJ45
10/100 Mbit/s
256 bytes IN/OUT
Modbus TCP functions:
3,4,6,16,23
5 = 126 slaves

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 256 byte IN/OUT
4 = Communications adapter, profile
n.12

DeviceNet

1 = 5*5.08 PLUG 2 = 125-500 kbit/s


3 = 256 byte IN/OUT
4 = Bit-strobed, Change-of-state or
Cyclic I/O

EtherNet/IP

1 = 2*RJ45 2 = 10/100 Mbit/s


3 = 256 byte IN/OUT
4 = DLR support

*See page 41 for mechanical and technical


specifications
*Wall mounted version for increased vibration
protection is also available. Contact HMS.

Page 16
Industrial networking made easy!

www.anybus.com

PROFIBUS configuration is defined


with NetTool-PB, a Windows
based configuration software for
PROFIBUS.
HMS NetTool-PB is included free of
charge with all CIP versions using a
PROFIBUS Master.
* See page 13 for more information

Tech Tip

The X-gateway is equipped with a


powerful PROFIBUS DPV1 Master
interface. No additional PROFIBUS
PLC or software is required.

Order information
Network:
Part No:
ControlNet
DeviceNet
EtherNet/IP

AB7803
AB7802
AB7800

Optional accessories

USB-RS232 configuration adapter


Part No: 019570

The X-gateway consists of two communication interfaces. The


first interface provides PROFIBUS DPV1 Master functionality
controlling up to 125 PROFIBUS Slaves. The second interface,
ControlNet, DeviceNet or EtherNet/IP Adapter functionality.

An easy way to transmit I/O data between a PROFIBUS


network and ControlNet, DeviceNet or EtherNet/IP

Allows for cyclic I/O data exchange between networks

Fast I/O data transfer with average timing between


networks: 10-15 ms

Additional parameter data supported (depending on


network combination)

Optional control and status information added to the I/O


data for diagnostic purposes

Included Anybus OPC server for extended functionality


available with the EtherNet/IP version

Robust stand-alone metal housing with HazLoc, ATEX, CE


and RoHS certifications

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other


5 = Amount of slaves / adapters

PROFIBUS

1=
2=
3=
4=

2*DSUB9
12 Mbit/s,
512 bytes IN/OUT
DPV1 Master, 5 = 125 slaves

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Comm adapter, profile n.12

DeviceNet

1 = 5*5.08 PLUG 2 = 125-500 kbit/s


3 = 512 byte IN/OUT
4 = Bit-strobed, Change-of-state or
Cyclic I/O

EtherNet/IP

1 = RJ45 2 = 10/100 Mbit/s


3 = 512 byte IN/OUT
4 = EIP group 2, DLR support

*See page 41 for mechanical and technical


specifications

Using the Rockwell Automation Integrated


Architecture Builder (IAB), engineers can integrate
the X-gateway making it easy to include in your
network system design.

Page 17
Industrial networking made easy!

www.anybus.com

NETWORK TO NETWORK GATEWAYS

Configuration is made over


Ethernet via a built-in web page.
It is used to configure Ethernet
TCP/IP settings, Modbus TCP client
configuration and I/O data register
mapping between Modbus TCP
and the chosen CIP network.

Accessories

Integrating Rockwell Automation


devices and PLC systems to
PROFIBUS installations.

DeviceNet Network

Coupling/De-coupling different
parts of a machine or extending
the physical network distance
within an installation.

ControlNet
DeviceNet
EtherNet/IP 2-port

When to use

PLC 5 DeviceNet Scanner

Integrating Rockwell Automation


devices and PLC systems to
Modbus TCP installations.

Anybus X-gateway - Network to network gateways

Anybus X-gateway - Network to network gateways

CANopen Slave connectivity to


ControlNet, DeviceNet & EtherNet/IP

CC-Link Slave connectivity to


ControlNet, DeviceNet & EtherNet/IP

Connecting a CANopen network to a Rockwell


Automation PLC system

Connecting a CC-Link network to a Rockwell


Automation PLC system

This Anybus X-gateway is a bridge between a CANopen


network and a Rockwell Automation PLC system with
ControlNet, DeviceNet or EtherNet/IP.

This Anybus X-gateway is a bridge between a CC-Link


network and a Rockwell Automation PLC system with
ControlNet, DeviceNet or EtherNet/IP.

The X-gateway copies cyclic I/O data in both directions


enabling data exchange between networks. This
ensures a consistent information flow throughout
the entire plant.

The X-gateway copies cyclic I/O data in both directions


enabling data exchange between networks. This
ensures a consistent information flow throughout
the entire plant.

When to use

MicroLogix PLC
EtherNet/IP Scanner

Integrating Rockwell Automation


devices and PLC systems to
CANopen installations.

Configuration

When to use
EtherNet/IP Network

Anybus X-gateway
Interface 1: EtherNet/IP Adapter
Interface 2: CANopen Slave

The X-gateway contains a built-in


configuration interface. For this
purpose, a PC with an installed terminal program (eg. Windows
Hyper Terminal) can be connected
to configure the I/O data sizes.

Slaves on a CANopen Network


PLC
CANopen Master

* See page 13 for more information

AB7868
AB7859
AB7838

* See page 14 for DeviceNet and EtherNet/IP


Master/Scanner versions

Optional accessories

USB-RS232 configuration adapter


Part No: 019570
Using the Rockwell
Automation Integrated
Architecture Builder
(IAB), engineers can
integrate the X-gateway making
it easy to include in your network
system design.

Configuration

EtherNet/IP Network

Anybus X-gateway
Interface 1: EtherNet/IP Adapter
Interface 2: CC-Link Slave

The X-gateway contains a built-in


configuration interface. For this
purpose, a PC with an installed terminal program (eg. Windows
Hyper Terminal) can be connected
to configure the I/O data sizes.

FMCG equipment (slaves) on a CC-Link Network


PLC
CC-Link Master

* See page 13 for more information

Order information
Network:
Part No:
The X-gateway consists of two communication interfaces. The
first interface provides CANopen Slave functionality. The second
interface provides ControlNet, DeviceNet or EtherNet/IP Adapter
functionality.

An easy way to transmit I/O data between a CANopen


network and ControlNet, DeviceNet or EtherNet/IP

Allows for cyclic I/O data exchange between networks

Fast I/O data transfer with average timing between


networks: 10-15 ms

CANopen PDO and SDO data objects supported

Optional control and status information added to the I/O


data for diagnostic purposes

Included Anybus OPC server for extended functionality


available with the EtherNet/IP version

EtherNet/IP version with IT functions such as dynamic web


server, supporting downloadable customer specific web
pages

Robust stand-alone metal housing with HazLoc, ATEX, CE


and RoHS certifications

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

CANopen

1=
2=
3=
4=

DSUB9M
10 Kbits to 1 Mbit/s,
512 bytes IN/OUT
Supports profile CIA DS301
V4.02

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

DeviceNet

EtherNet/IP

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Communications adapter, profile
n.12
1 = 5*5.08 PLUG 2 = 125-500 kbit/s
3 = 512 byte IN/OUT
4 = Bit-strobed, Change-of-state or
Cyclic I/O
1 = RJ45 2 = 10/100 Mbit/s
3 = 512 byte IN/OUT
4 = EIP group 2, DLR support

*See page 41 for mechanical and technical


specifications

Page 18
Industrial networking made easy!

www.anybus.com

ControlNet
DeviceNet
EtherNet/IP

AB7871
AB7862
AB7841

* See page 14 for DeviceNet and EtherNet/IP


Master/Scanner versions

Optional accessories

USB-RS232 configuration adapter


Part No: 019570
Using the Rockwell
Automation Integrated
Architecture Builder
(IAB), engineers can
integrate the X-gateway making
it easy to include in your network
system design.

The X-gateway consists of two communication interfaces. The


first interface provides CC-Link Slave functionality. The second
interface provides ControlNet, DeviceNet or EtherNet/IP Adapter
functionality.

An easy way to transmit I/O data between a CC-Link


network and ControlNet, DeviceNet or EtherNet/IP

Allows for cyclic I/O data exchange between networks

Fast I/O data transfer with average timing between


networks: 10-15 ms

Optional control and status information added to the I/O


data for diagnostic purposes

Uses the CC-Link PLC profile for data exchange

Included Anybus OPC server for extended functionality


available with the EtherNet/IP version

EtherNet/IP version with IT functions such as dynamic web


server, supporting downloadable customer specific web
pages

Robust stand-alone metal housing with HazLoc, ATEX, CE


and RoHS certifications

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

CC-Link

1 = DSUB9 Female
2 = 156 kbps to 10 Mbit/s,
3 = Ver 1: 128 I/O points, 16 words
IN/OUT
4 = Ver 2.0: 896 I/O points, 128
words IN/OUT

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Communications adapter,
profile n.12

DeviceNet

1 = 5*5.08 PLUG 2 = 125-500 kbit/s


3 = 512 byte IN/OUT
4 = Bit-strobed, Change-of-state or
Cyclic I/O

EtherNet/IP

1 = RJ45 2 = 10/100 Mbit/s


3 = 512 byte IN/OUT
4 = EIP group 2, DLR support

*See page 41 for mechanical and technical


specifications

Page 19
Industrial networking made easy!

www.anybus.com

NETWORK TO NETWORK GATEWAYS

Order information
Network:
Part No:
ControlNet
DeviceNet
EtherNet/IP

ControlLogix PLC
EtherNet/IP Scanner

Integrating Rockwell Automation


devices and PLC systems to CC-Link
installations.

Anybus X-gateway - Network to network gateways

Anybus X-gateway - Network to network gateways

ControlNet Adapter to Fieldbus


and Industrial Ethernet

DeviceNet Adapter to Fieldbus


and Industrial Ethernet

Connecting a ControlNet network to any other


Fieldbus or Industrial Ethernet network

Connecting a DeviceNet network to any other


Fieldbus or Industrial Ethernet network

This Anybus X-gateway is a bridge between a ControlNet


network and any other network from another PLC
vendor.

This Anybus X-gateway is a bridge between an


DeviceNet network and any other network from
another PLC vendor.

X-gateways are designed for use in industrial


automation plants where many different networks are
used. They copy cyclic I/O data in both directions
enabling a consistent information flow throughout
the entire plant.

X-gateways are designed for use in industrial


automation plants where many different networks are
used. They copy cyclic I/O data in both directions
enabling a consistent information flow throughout
the entire plant.

When to use

When to use
ControlNet Network

Enabling Rockwell Automation


devices with a ControlNet
interface to participate on other
PLC systems and networks.

Anybus X-gateway
Interface 1: ControlNet Adapter
Interface 2: PROFINET I/O Device

Coupling/De-coupling different
parts of a machine or extending
the physical network distance
within an installation.

Order information
Network:
Part.No
AS-Interface Master
CANopen Master
Modbus TCP Master
PROFIBUS Master

AB7823
AB7303
AB9003
AB7803

CANopen Slave
CC-Link Slave
ControlNet Adapter
DeviceNet Adapter
EtherNet/IP Adapter
EtherCAT Slave
Interbus Slave
Interbus Fiber Optic
Lonworks
Modbus Plus Slave
Modbus RTU Slave
Modbus TCP Slave
PROFIBUS Slave
PROFIBUS IO Device
PROFINET IRT Device

AB7838
AB7871
AB7864
AB7855
AB7834
AB7687
AB7866
AB7867
AB7872
AB7870
AB7869
AB7636
AB7845
AB7654
AB7941

Example: PROFINET Network


PLC

This X-gateway provides one communication


interface with ControlNet Adapter/Slave functionality. The
second interface can be a choice of 14 other industrial networks
(Master/Slave) including, CANopen, Modbus, PROFIBUS,
PROFINET, EtherCAT and more.

Configuration

ControlNet I/O data size and other


network configurations can be
made in various ways depending on
the X-gateway version selected.
* See page 13 for more information

An easy way to transmit I/O data between a ControlNet


network and any other industrial network

Interconnects Rockwell Automation PLC systems with other


PLC types

Fast I/O data transfer with average timing between


networks: 10-15 ms (approx 5 ms Modbus TCP Master
versions)

Included Anybus OPC server and IT functions such as web


browser, email and FTP client for versions supporting
PROFINET and Modbus-TCP

I/O data configuration via on-board interface or via the free


and included Anybus Configuration Manager

Get up-and-running quickly, no programming skills required

Robust stand-alone metal housing with HazLoc, ATEX, CE


and RoHS certifications

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Communications adapter, profile
n.12

*See page 41 for mechanical and technical


specifications

Using the Rockwell


Automation Integrated
Architecture Builder (IAB),
engineers can integrate
the X-gateway making it easy to
include in your network system
design.

Page 20
Industrial networking made easy!

PLC 5 DeviceNet Scanner

Interconnecting PLC systems and


networks from similar or different
vendors.

www.anybus.com

DeviceNet Network

Enabling Rockwell Automation


devices with a DeviceNet interface
to participate on other PLC
systems and networks.

Anybus X-gateway
Interface 1: DeviceNet Adapter
Interface 2: Modbus TCP Slave

Coupling/De-coupling different
parts of a machine or extending
the physical network distance
within an installation.

Order information
Network:
Part.No
AS-Interface Master
CANopen Master
Modbus TCP Master
PROFIBUS Master

AB7822
AB7302
AB9002
AB7802

CANopen Slave
CC-Link Slave
ControlNet Adapter
DeviceNet Adapter
EtherNet/IP Adapter
EtherCAT Slave
Interbus Slave
Interbus Fiber Optic
Lonworks
Modbus Plus Slave
Modbus RTU Slave
Modbus TCP Slave
PROFIBUS Slave
PROFINET IO Device
PROFINET IRT Device

AB7859
AB7862
AB7855
AB7854
AB7833
AB7686
AB7857
AB7858
AB7863
AB7861
AB7860
AB7635
AB7844
AB7653
AB7940

Example: Modbus TCP Network


PLC
Modbus TCP Master

This X-gateway provides one communication interface with


DeviceNet Adapter/Slave functionality. The second interface
can be a choice of 14 other industrial networks (Master/Slave)
including, CANopen, Modbus, PROFIBUS, PROFINET, EtherCAT
and more.

Configuration

An easy way to transmit I/O data between a


DeviceNet network and any other industrial network

* See page 13 for more information

Interconnects Rockwell Automation PLC systems with other


PLC types

Fast I/O data transfer with average timing between


networks: 10-15 ms (approx 5 ms with CANopen and
Modbus TCP Master versions)

Included Anybus OPC server and IT functions such as web


browser, email and FTP client for versions supporting
PROFINET and Modbus-TCP

I/O data configuration via on-board interface or via the free


and included Anybus Configuration Manager

Get up-and-running quickly, no programming skills required

Robust stand-alone metal housing with HazLoc, ATEX, CE


and RoHS certifications

DeviceNet I/O data size and other


network configurations can be
made in various ways depending on
the X-gateway version selected.

Network Features
DeviceNet Adapter Features

1 = Network connector, 2 = Baud rate, 3 = I/O data,


4= Other

DeviceNet

1 = 5*5.08 PLUG 2 = 125-500 kbit/s


3 = 512 byte IN/OUT
4 = Bit-strobed, Change-of-state or
Cyclic I/O

*See page 41 for mechanical and technical


specifications

Using the Rockwell


Automation Integrated
Architecture Builder
(IAB), engineers can
integrate the X-gateway making
it easy to include in your network
system design.

Page 21
Industrial networking made easy!

www.anybus.com

NETWORK TO NETWORK GATEWAYS

ControlLogix PLC
ControlNet Scanner

Interconnecting PLC systems and


networks from similar or different
vendors.

Anybus X-gateway - Network to network gateways

Anybus X-gateway - Network to network gateways

EtherNet/IP Adapter to Fieldbus


and Industrial Ethernet

EtherCAT Slave connectivity to


ControlNet, DeviceNet & EtherNet/IP

Connecting an EtherNet/IP network to any other


Fieldbus or Industrial Ethernet network

Connecting an EtherCAT network to a Rockwell


Automation PLC system

This Anybus X-gateway is a bridge between an


EtherNet/IP network and any other network from
another PLC vendor.

This Anybus X-gateway is a bridge between an EtherCAT


network and a Rockwell Automation PLC system with
ControlNet, DeviceNet or EtherNet/IP.

X-gateways are designed for use in industrial


automation plants where many different networks are
used. They copy cyclic I/O data in both directions
enabling a consistent information flow throughout
the entire plant.

The X-gateway copies cyclic I/O data in both directions


enabling data exchange between networks. This
ensures for a consistent information flow throughout
the entire plant.

When to use

When to use
EtherNet/IP Network

Enabling older fieldbus network


migration to the EtherNet/IP
network.

Anybus X-gateway
Interface 1: EtherNet/IP Adapter
Interface 2: Modbus RTU Slave

Coupling/De-coupling different
parts of a machine or extending
the physical network distance
within an installation.

AB7820
AB7306
AB9006
AB7800

CANopen Slave
CC-Link Slave
ControlNet Adapter
DeviceNet Adapter
EtherNet/IP Adapter
EtherCAT Slave
Interbus Slave
Interbus Fiber Optic
J1939
Lonworks
Modbus Plus Slave
Modbus RTU Slave
Modbus TCP Slave
PROFIBUS Slave
PROFINET IO Device
PROFINET IRT Device

AB7838
AB7841
AB7834
AB7833
AB7668
AB7682
AB7836
AB7837
AB7665
AB7842
AB7840
AB7839
AB7632
AB7832
AB7649
AB7942

PLC
Modbus RTU Master

This X-gateway provides one communication


interface with EtherNet/IP Adapter/Slave functionality. The second interface can be a choice of 14 other industrial
networks (Master/Slave) including, CANopen, Modbus,
PROFIBUS, PROFINET, EtherCAT and more.

Configuration

An easy way to transmit I/O data between an


EtherNet/IP network and any other industrial network

* See page 13 for more information

Interconnects Rockwell Automation PLC systems with other


PLC types

Fast I/O data transfer with average timing between


networks: 10-15 ms (approx 5 ms with CANopen and
Modbus TCP Master versions)

Included Anybus OPC server for extended functionality

EtherNet/IP interface with IT functions such as dynamic web


server, supporting downloadable customer specific web
pages

I/O data configuration via on-board interface or via the free


and included Anybus Configuration Manager

Get up-and-running quickly, no programming skills required

Robust stand-alone metal housing with HazLoc, ATEX, CE


and RoHS certifications

DeviceNet Network

Coupling/De-coupling different
parts of a machine or extending
the physical network distance
within an installation.

Anybus X-gateway
Interface 1: DeviceNet Adapter
Interface 2: EtherCAT Slave

Configuration

Example: Modbus RTU Network

Order information
Network:
Part.No
AS-Interface Master
CANopen Master
Modbus TCP Master
PROFIBUS Master

PLC 5 DeviceNet Scanner

Integrating Rockwell Automation


devices and PLC systems to
EtherCAT installations.

EtherNet/IP I/O data size and other


network configurations can be
made in various ways depending on
the X-gateway version selected.

The X-gateway contains a built-in


configuration interface. For this
purpose, a PC with an installed
terminal program (eg. Windows
Hyper Terminal) can be connected
to configure the I/O data sizes.
* See page 13 for more information

Order information
Network:
Part No:
ControlNet
DeviceNet
EtherNet/IP

AB7687
AB7686
AB7682

Example: EtherCAT Network

PLC Master

This X-gateway consists of two communication interfaces. The


first interface provides EtherCAT Slave functionality. The second
interface with provides ControlNet, DeviceNet or EtherNet/IP
Adapter functionality.

An easy way to transmit I/O data between a EtherCAT


network and ControlNet, DeviceNet or EtherNet/IP

Allows for cyclic I/O data exchange between networks

Fast I/O data transfer with average timing between


networks: 10-15 ms

CANopen PDO and SDO data objects supported

Optional control and status information added to the I/O


data for diagnostic purposes

*See page 41 for mechanical and technical


specifications

Included Anybus OPC server for extended functionality


available with the EtherNet/IP version only

Using the Rockwell


Automation Integrated
Architecture Builder (IAB),
engineers can integrate
the X-gateway making it easy to
include in your network system
design.

Robust stand-alone metal housing with HazLoc, ATEX, CE


and RoHS certifications

Network Features
EtherNet/IP Adapter Features

1 = Network connector, 2 = Baudrate, 3 = I/O data,


4= Other

EtherNet/IP

Page 22
Industrial networking made easy!

1 = RJ45
2 = 10/100 Mbit/s 3 = 512 IN/OUT
4 = EtherNet/IP group 2 and 3
server. DLR support

www.anybus.com

* See page 14 for DeviceNet and EtherNet/IP


Master/Scanner versions

Optional accessories

USB-RS232 configuration adapter


Part No: 019570

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

EtherCAT

1 = 2*RJ45 2 = 100 Mbit/s


3 = 512 byte IN/OUT
4 = Supports CANopen objects PDO
and SDO

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Comm adapter, profile n.12

DeviceNet

1 = 5*5.08 PLUG 2 = 125-500 kbit/s


3 = 512 byte IN/OUT
4 = Bit-strobed, Change-of-state or
Cyclic I/O

EtherNet/IP

1 = RJ45 2 = 10/100 Mbit/s


3 = 512 byte IN/OUT
4 = EIP group 2, DLR support

*See page 41 for mechanical and technical


specifications

Using the Rockwell Automation Integrated


Architecture Builder (IAB), engineers can integrate
the X-gateway making it easy to include in your
network system design.
Page 23
Industrial networking made easy!

www.anybus.com

NETWORK TO NETWORK GATEWAYS

Interconnecting PLC systems and


networks from similar or different
vendors.

Anybus X-gateway - Network to network gateways

Anybus X-gateway - Network to network gateways

J1939 network connectivity to


EtherNet/IP

Modbus RTU Slave connectivity to


ControlNet, DeviceNet & EtherNet/IP

Connecting a CAN-based SAE J1939 protocol to a


Rockwell Automation PLC system using EtherNet/IP

Connecting a Modbus RTU network to a Rockwell


Automation PLC system

This Anybus X-gateway is a bridge between the CAN


based SAE J1939 network and a Rockwell Automation
PLC system with EtherNet/IP.

This Anybus X-gateway is a bridge between a Modbus


RTU network and a Rockwell Automation PLC system
with ControlNet, DeviceNet or EtherNet/IP.

The X-gateway copies cyclic I/O data in both directions


enabling data exchange between networks. This
ensures for a consistent information flow throughout
the entire plant.

The X-gateway copies cyclic I/O data in both directions


enabling data exchange between networks. This
ensures for a consistent information flow throughout
the entire plant.

When to use

As a low-cost stand-alone gateway


used on oil and gas equipment,
marine vessels, locomotives,
pumping stations, generators,
engine test cells and other mobile
and stationary equipment.

EtherNet/IP Network

Use to access engine parameters


from a Programmable Logic
Controller (PLC), HMI or PC and
send data to the J1939 network
for control and management.
Used as an on-vehicle gateway to
interface a J1939 network to an
on-board industrial automationbased control and monitoring
system or HMI.

Configuration

Configuration of the X-gateway


J1939 is simple using the free
and included Windows based
BWConfig software. It enables
the setting up of an I/O table
containing selected J1939 PGNs
and the rate that each will be
read or written from the J1939
network.
BWConfig will then automatically
map the I/O table to a range of
addresses accessible from the
X-gateway EtherNet/IP interface.
The configuration is downloaded
from the PC to the X-gateway via
an RS-232 connection and is saved
in the FLASH memory.

Order information
Network:
Part No:
EtherNet/IP

AB7665

HMI/SCADA

Industrial PC

ControlLogix
PLC Scanner

Integrating Rockwell Automation


devices and PLC systems to
Modbus RTU installations.

ControlLogix PLC

Anybus X-gateway
Interface 1: EtherNet/IP Adapter
Interface 2: SAE J1939

EtherNet/IP Network

Retro-fitting devices on an older


installation with a Modbus Plus
network into a modern CIP
architecture.

Anybus X-gateway
Interface 1: EtherNet/IP Adapter
Interface 2: Modbus RTU Slave

Coupling/De-coupling different
parts of a machine or extending
the physical network distance
within an installation.

Example: Equipment using J1939

Example: Devices on a Modbus RTU Network


PLC
Modbus RTU
Master

Did you know?

The X-gateway consists of two communication interfaces. The


first interface provides SAE J1939 connectivity. The second
interface provides ControlNet, DeviceNet or EtherNet/IP
Adapter functionality.

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

J1939

An easy way to transmit I/O data between a J1939


and EtherNet/IP. With additional support for Modbus TCP.
Fast I/O data transfer with average timing between
networks: 10-15 ms

Use to access engine parameters from a Programmable


Logic Controller (PLC), HMI or PC

Transmission and reception of all types of J1939 messages,


including PDU1, PDU2, broadcast and destination specific

J1939 Transport Protocol for transmission and reception


of large messages (Both connection based (RTS/CTS) and
broadcast (BAM) are supported

Included Anybus OPC server for extended functionality


available with the EtherNet/IP version

EtherNet/IP interface with IT functions such as dynamic


web server, supporting downloadable customer specific
web pages

Robust stand-alone metal housing with HazLoc, ATEX, CE


and RoHS certifications

1=
2=
3=
4=

5-pole 5.08 mm
N/A
9 - 1785 bytes
Accordance to J1939-81 spec

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

EtherNet/IP

1 = RJ45 2 = 10/100 Mbit/s


3 = 512 byte IN/OUT
4 = EIP group 2, DLR support

*See page 41 for mechanical and technical


specifications

Using the Rockwell


Automation Integrated
Architecture Builder (IAB),
engineers can integrate
the X-gateway making it easy to
include the gateway in your system
network design.

Page 24
Industrial networking made easy!

Anybus Communicator RTU with


RTU Master functionality could
be used instead if there is a no
existing Modbus RTU PLC Master
within the installation.

The X-gateway consists of two communication interfaces. The


first interface provides Modbus RTU Slave functionality. The
second interface provides ControlNet, DeviceNet or EtherNet/IP
Adapter functionality.

Network specific features

Configuration

An easy way to transmit I/O data between a Modbus RTU


network and ControlNet, DeviceNet or EtherNet/IP

Network specific features

Allows for cyclic I/O data exchange between networks

Fast I/O data transfer with average timing between


networks: 10-15 ms

Support for Modbus RTU functions: 1, 2, 3, 4, 5, 6, 8, 15,16,


22, 23

Included Anybus OPC server for extended functionality


available with the EtherNet/IP version

EtherNet/IP side with IT functions such as dynamic web


server, for downloadable customer specific web pages

The X-gateway contains a built-in


configuration interface. For this
purpose, a PC with an installed
terminal program (eg. Windows
Hyper Terminal) can be connected
to configure the I/O data sizes.
* See page 13 for more information

Order information
Network:
Part No:
ControlNet
DeviceNet
EtherNet/IP

AB7869
AB7860
AB7839

* See page 14 for DeviceNet and EtherNet/IP


Master/Scanner versions

Optional accessories

USB-RS232 configuration adapter


Part No: 019570
www.anybus.com

Robust stand-alone metal housing with HazLoc, ATEX, CE


and RoHS certifications

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

Modbus
RTU

1 = DSUB9F 2 = 1,2-57,6 kbit/s


3 = 256 registers in each direction
4 = RS232 and RS485 transmission

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Comm adapter, profile n.12

DeviceNet

1 = 5*5.08 PLUG 2 = 125-500 kbit/s


3 = 512 byte IN/OUT
4 = Bit-strobed, Change-of-state or
Cyclic I/O

EtherNet/IP

1 = RJ45 2 = 10/100 Mbit/s


3 = 512 byte IN/OUT
4 = EIP group 2, DLR support

*See page 41 for mechanical and technical


specifications

Using the Rockwell Automation Integrated


Architecture Builder (IAB), engineers can integrate
the X-gateway making it easy to include in your
network system design.

Page 25
Industrial networking made easy!

www.anybus.com

NETWORK TO NETWORK GATEWAYS

When to use

For Modbus RTU Master


See page 8

Anybus X-gateway - Network to network gateways

Anybus X-gateway - Network to network gateways

Modbus TCP Slave connectivity to


ControlNet, DeviceNet & EtherNet/IP

PROFIBUS DPV1 Slave connectivity to


ControlNet, DeviceNet & EtherNet/IP

Connecting a Modbus TCP network to a Rockwell


Automation PLC system

Connecting a PROFIBUS network to a Rockwell


Automation PLC system

This Anybus X-gateway is a bridge between a Modbus


TCP network and a Rockwell Automation PLC system
with ControlNet, DeviceNet or EtherNet/IP.

This Anybus X-gateway is a bridge between a PROFIBUS


network and a Rockwell Automation PLC system with
ControlNet, DeviceNet or EtherNet/IP.

ControlLogix
PLC Scanner

When to use

Integrating Rockwell Automation


devices and PLC systems to
Modbus TCP installations.
Coupling/De-coupling different
parts of a machine or extending
the physical network distance
within an installation.

* See page 13 for more information

Order information
Network:
Part No:
ControlNet
DeviceNet
EtherNet/IP

AB7636
AB7635
AB7632

* See page 14 for DeviceNet and EtherNet/IP


Master/Scanner versions

Optional accessories

USB-RS232 configuration adapter


Part No: 019570

PLC
Modbus TCP
Master

The X-gateway consists of two communication interfaces. The


first interface provides Modbus TCP Slave functionality. The
second interface provides ControlNet, DeviceNet or EtherNet/IP
Adapter functionality.

Network specific features

An easy way to transmit I/O data between a Modbus TCP


network to ControlNet, DeviceNet or EtherNet/IP

Network specific features

Allows for cyclic I/O data exchange between networks

Fast I/O data transfer with average timing between


networks: 10-15 ms

Modbus/TCP class 0, class 1 and partially class 2 slave


functionality

Included Anybus OPC server for extended functionality


available with the EtherNet/IP version
EtherNet/IP side with IT functions such as dynamic web
server, for downloadable customer specific web pages

Robust stand-alone metal housing with HazLoc, ATEX, CE


and RoHS certifications

Retro-fitting an existing installation


and migrating from PROFIBUS to
Industrial Ethernet (EtherNet/IP)

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

Modbus
TCP

1 = 2*RJ45 2 = 100 Mbit/s


3 = 512 byte IN/OUT
4 = Classes 0, 1 and partial Class 2

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

DeviceNet

EtherNet/IP

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Communications adapter, profile
n.12
1 = 5*5.08 PLUG 2 = 125-500 kbit/s
3 = 512 byte IN/OUT
4 = Bit-strobed, Change-of-state or
Cyclic I/O
1 = RJ45 2 = 10/100 Mbit/s
3 = 512 byte IN/OUT
4 = EIP group 2, DLR support

*See page 41 for mechanical and technical


specifications

Using the Rockwell Automation Integrated


Architecture Builder (IAB), engineers can integrate
the X-gateway making it easy to include in your
network system design.
Page 26
Industrial networking made easy!

www.anybus.com

EtherNet/IP Network

Anybus X-gateway
Interface 1: EtherNet/IP Adapter
Interface 2: PROFIBUS DPV1 Slave

Coupling/De-coupling different
parts of a machine or extending
the physical network distance.

Example: Devices on a Modbus TCP Network

ControlLogix PLC
EtherNet/IP Scanner

Integrating Rockwell Automation


devices and PLC systems to
PROFIBUS installations.

Anybus X-gateway
Interface 1: ControlNet Adapter
Interface 2: Modbus TCP Slave

Configuration

The X-gateway contains a built-in


configuration interface. For this
purpose, a PC with an installed terminal program (eg. Windows
Hyper Terminal) can be connected
to configure the I/O data sizes.

When to use
ControlNet Network

For PROFIBUS DPV1 Master


See page 17

The X-gateway copies cyclic I/O data in both directions


enabling data exchange between networks. This
ensures for a consistent information flow throughout
the entire plant.

Drives (slaves) on an PROFIBUS Network


PLC

PROFIBUS Master

Configuration

The X-gateway contains a built-in


configuration interface. For this
purpose, a PC with an installed terminal program (eg. Windows
Hyper Terminal) can be connected
to configure the I/O data sizes.
* See page 13 for more information

The X-gateway consists of two communication interfaces. The


first interface provides PROFIBUS DP/DPV1 Slave functionality.
The second interface provides ControlNet, DeviceNet or
EtherNet/IP Adapter functionality.

An easy way to transmit I/O data between a PROFIBUS


network to ControlNet, DeviceNet or EtherNet/IP

Allows for cyclic I/O data exchange between networks

Fast I/O data transfer with average timing between


networks: 10-15 ms

* See page 14 for DeviceNet and EtherNet/IP


Master/Scanner versions

Optional accessories

Additional parameter data supported (depending on


network combination)

Optional control and status information added to the I/O


data for diagnostic purposes

PROFIBUS functionality such as Watchdog, Sync and Freeze


and diagnostics. Standard DP as well as DPV1 acyclic data
services (Class1/Class2)

Included Anybus OPC server for extended functionality


available with the EtherNet/IP version

Robust stand-alone metal housing with HazLoc, ATEX, CE


and RoHS certifications

Order information
Network:
Part No:
ControlNet
DeviceNet
EtherNet/IP

AB7845
AB7844
AB7832

USB-RS232 configuration adapter


Part No: 019570
Using the Rockwell
Automation Integrated
Architecture Builder
(IAB), engineers can
integrate the X-gateway making
it easy to include in your network
system design.

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

PROFIBUS

1=
2=
3=
4=

DSUB9
Up to 12 Mbit/s,
244 bytes IN/OUT
DP/DPV1

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Comm adapter, profile n.12

DeviceNet

1 = 5*5.08 PLUG 2 = 125-500 kbit/s


3 = 512 byte IN/OUT
4 = Bit-strobed, Change-of-state or
Cyclic I/O

EtherNet/IP

1 = RJ45 2 = 10/100 Mbit/s


3 = 512 byte IN/OUT
4 = EIP group 2, DLR support

*See page 41 for mechanical and technical


specifications

Page 27
Industrial networking made easy!

www.anybus.com

NETWORK TO NETWORK GATEWAYS

For Modbus TCP Master


See page 16

The X-gateway copies cyclic I/O data in both directions


enabling data exchange between networks. This
ensures for a consistent information flow throughout
the entire plant.

Anybus X-gateway - Network to network gateways

Anybus X-gateway - Network to network gateways

PROFINET I/O Slave connectivity to


ControlNet, DeviceNet & EtherNet/IP

PROFINET IRT Slave connectivity to


ControlNet, DeviceNet & EtherNet/IP

Connecting a PROFINET network to a Rockwell


Automation PLC system

Connecting a PROFINET IRT network to a Rockwell


Automation PLC system

This Anybus X-gateway is a bridge between a


PROFINET I/O network and a Rockwell Automation PLC
system with ControlNet, DeviceNet or EtherNet/IP.

This Anybus X-gateway is a bridge between a PROFINET


IRT network and a Rockwell Automation PLC system with
ControlNet, DeviceNet or EtherNet/IP.

The X-gateway copies cyclic I/O data in both directions


enabling data exchange between networks. This
ensures a consistent information flow throughout
the entire plant.

The X-gateway copies cyclic I/O data in both directions


enabling data exchange between networks. This
ensures for a consistent information flow throughout
the entire plant.

When to use

Integrating Rockwell Automation


devices and PLC systems to
PROFINET IRT installations.

When to use

PLC 5 DeviceNet Scanner


DeviceNet Network

Coupling/De-coupling different
parts of a machine or extending
the physical network distance
within an installation.

The X-gateway contains a built-in


configuration interface. For this
purpose, a PC with an installed terminal program (eg. Windows
Hyper Terminal) can be connected
to configure the I/O data sizes.
* See page 13 for more information

Order information
Network:
Part No:
ControlNet
DeviceNet
EtherNet/IP

AB7654
AB7653
AB7849

* See page 14 for DeviceNet and EtherNet/IP


Master/Scanner versions

Optional accessories

USB-RS232 configuration adapter


Part No: 019570
Using the Rockwell
Automation Integrated
Architecture Builder
(IAB), engineers can
integrate the X-gateway making
it easy to include in your network
system design.

Example: PROFINET Network


PLC Master

The X-gateway consists of two communication interfaces. The


first interface provides PROFINET I/O Device/Slave functionality.
The second interface provides ControlNet, DeviceNet or
EtherNet/IP Adapter functionality.

An easy way to transmit I/O data between a PROFINET


network to ControlNet, DeviceNet or EtherNet/IP

Allows for cyclic I/O data exchange between networks

Fast I/O data transfer with average timing between


networks: 10-15 ms

Additional parameter data supported (depending on


network combination)

Optional control and status information added to the I/O


data for diagnostic purposes

PROFINET IO device functionality Conformance Class A

Included Anybus OPC server for extended functionality


available with the EtherNet/IP version

Robust stand-alone metal housing with HazLoc, ATEX, CE


and RoHS certifications

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

PROFINET

1 = RJ45 2 = 10/100 Mbit/s


3 = 220 byte IN/OUT
4 = RT Communication and Cyclic data
exchange, IO Device, Class A

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Communications adapter, profile
n.12

DeviceNet

1 = 5*5.08 PLUG 2 = 125-500 kbit/s


3 = 512 byte IN/OUT
4 = Bit-strobed, Change-of-state or
Cyclic I/O

EtherNet/IP

1 = RJ45 2 = 10/100 Mbit/s


3 = 512 byte IN/OUT
4 = EIP group 2, DLR support

*See page 41 for mechanical and technical


specifications

Page 28
Industrial networking made easy!

EtherNet/IP Network

Did you know?

Anybus X-gateway
Interface 1: DeviceNet Adapter
Interface 2: PROFINET I/O Device

Configuration

ControlLogix PLC
EtherNet/IP Scanner

The AIDA Group - Audi, BMW,


Daimler, Porsche and VW
standardize on PROFINET
technology.
Automation devices must fulfil
specific PROFINET capabilities to
be approved for their production
facilities. As the X-gateway
technology is certified by AIDA,
Rockwell Automation equipment
could be installed in these
automotive plants.

Configuration

The X-gateway contains a built-in


configuration interface. For this
purpose, a PC with an installed
terminal program (eg. Windows
Hyper Terminal) can be connected
to configure the I/O data sizes.
* See page 13 for more information

Order information
Network:
Part No:
ControlNet
DeviceNet
EtherNet/IP

AB7941
AB7940
AB7942

* See page 14 for DeviceNet and EtherNet/IP


Master/Scanner versions

Optional accessories

USB-RS232 configuration adapter


Part No: 019570

Anybus X-gateway
Interface 1: EtherNet/IP Adapter
Interface 2: PROFINET IRT Device

Example: PROFINET IRT Network


PLC Master

The X-gateway consists of two communication interfaces. The


first interface provides PROFINET IRT Device/Slave functionality.
The second interface provides ControlNet, DeviceNet or
EtherNet/IP Adapter functionality.

An easy way to transmit I/O data between a PROFINET IRT


network to ControlNet, DeviceNet or EtherNet/IP

Allows for cyclic I/O data exchange between networks

Integrated PROFINET IRT 2-port switch functionality

Fast I/O data transfer between the two networks

Additional parameter data supported (depending on


network combination)

Optional control and status information added to the I/O


data for diagnostic purposes

PROFINET IRT device functionality Conformance Class C

Included Anybus OPC server for extended functionality


available with the EtherNet/IP version

Robust stand-alone metal housing with HazLoc, ATEX, CE


and RoHS certifications
Using the Rockwell Automation Integrated
Architecture Builder (IAB), engineers can integrate
the X-gateway making it easy to include in your
network system design.

www.anybus.com

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

PROFINET
IRT

1 = 2*RJ45 2 = 100 Mbit/s


3 = 220 byte IN/OUT
4 = IRT Communication and Cyclic
data exchange, IO Device, Class C

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = 2*BNC Coax + RJ45 (NAP)


2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Communications adapter,
profile n.12

DeviceNet

1 = 5*5.08 PLUG 2 = 125-500


kbit/s
3 = 512 byte IN/OUT
4 = Bit-strobed, Change-of-state or
Cyclic I/O

EtherNet/IP

1 = RJ45 2 = 10/100 Mbit/s


3 = 512 byte IN/OUT
4 = EIP group 2, DLR support

*See page 41 for mechanical and technical


specifications

Page 29
Industrial networking made easy!

www.anybus.com

NETWORK TO NETWORK GATEWAYS

Integrating Rockwell Automation


devices and PLC systems to
PROFINET installations.

Anybus Wireless Bridge - Proven wireless BluetoothTM or WLAN connectivity

Anybus Wireless Bridge


Connecting EtherNet/IP installations via Bluetooth
or Wireless LAN (WLAN)
Anybus Wireless Bridge allows Industrial Ethernetbased equipment to be installed with wireless WLAN or
Bluetooth technology.
This makes it possible to bridge the EtherNet/IP
protocol over a distance of up to max. 1000 meters
(open air range).

When to use

Devices and equipment connected via


Ethernet cables can be a problem.
When setting up communication through
hazardous areas, hard-to-reach locations
or moving installations, cables are just not
desirable.

Configuration

Configuration is made through a


push button method or with a web
configuration page.
SNMP AT commands are available
for advanced setup.

Order information
Wireless version
Part No:
WLAN 2.4 GHz
WLAN 2.4 GHz + cabling
WLAN 5.0 GHz
WLAN 2.4 GHz + cabling
Bluetooth
Bluetooth + cabling

021440-B
021445-B
021450-B
021450-B
021430-B
021435-B

Optional accessories

All versions with cabling include


the following:
1x Anybus Wireless Bridge unit
1x 12VDC power adapter with
M12 connector and relevant
power plug converter.
1x Ethernet cable (1.8 m) with
RJ45 and M12 connectors

Wireless transmission is made via WLAN 2.4 or 5 GHZ or via


Bluetooth technology. The Anybus Wireless Bridge is an
Intelligent antenna thanks to the ease of use and cost efficiency
of the installation and configuration. Another unique feature is
the Low Emission Mode which solve potential interference
disturbances.

Wireless LAN 802.11b/g/n or Bluetooth transmission

Wireless LAN 2.4 (Range 400 meters) and 5 GHz version


(Range 200 meters)

Point-to-point Ethernet cable replacement (both in Ad-Hoc


and Infrastructure mode)

Wireless LAN client adapter in an Infrastructure setup

Bluetooth version 2.1 + EDR, Range: 1000 m (open air)

Part of a Multipoint setup with a NAP device (Bluetooth)

Unique Low Emission Modeto handle interference


disturbances without consequences to the WLAN
conformity or the interoperability with other devices

Built-in antenna with a unique half globe radio coverage


pattern, making installation easy and cost efficient

Support for redundant wireless networks for critical


applications

Easy configuration via push button or via web configuration


pages

NETWORK COMMUNICATION
Ethernet Interface: 10/100BASE-T
with automatic MDI/MDIX crossover IP, TCP, UDP, HTTP, LLDP, ARP,
DHCP Client/Server, DNS support,
SNMP user management and access
control

WIRELESS SUPPORT
IEEE802.11b/g, Bluetooth 2.1

SECURITY
WEP64, WEP128,WPA-PSk, WPA2PSk, TkIP, CCMP (AES) and LEAP


DIMENSIONS
91 x 66 x 36.2 mm (LxWxH)
3.58 x 2.6 x 1.42 (LxWxH)
ENVIRONMENTAL
Operating temp: -30 to +65 C
Storage temp: -40 to +85C
Humidity RH 5-90% non-condensing
POWER
9-30 VDC, OEM*: 3.3 VDC
HOUSING
IP65 classed plastic housing with
sealed M12 connectors
*See www.anybus.com for more information

Page 31
Industrial networking made easy!

www.anybus.com

WIRELESS ethernet

When Ethernet cables


are not desirable!

Especially suitable for mobile,


rotating and temporary
installations where there is a need
for replacing the Ethernet cable
with a robust and maintenancefree wireless connection.

Netbiter Remote management solution

Netbiter Remote management solution

Save time, save energy, save resources!

A REMOTE MANAGEMENT SYSTEM ENABLING YOU TO


SUPERVISE AND CONTROL INDUSTRIAL EQUIPMENT
Remote access to
Rockwell Automation
equipment
Through Netbiter you can now read/write
parameter data, or even start or stop Rockwell
Automation equipment such as PLCs, drives,
power relays, temperature controllers etc.
Netbiter provides a secure connection to Rockwell Automation
equipment via a Netbiter EasyConnect communication gateway.

Netbiter is unlike any other solution.


It takes the hassle out of remote
management and gets your devices and
equipment online fast!

What you get with Netbiter:


Secure hosting via
Netbiter Argos
Access and store your device / installation data.

Netbiter system overview

1. Secure hosting via Netbiter Argos


2. Argos cloud based management services

Real-time access to your device data 24/7

Pre-made or customized device dashboards

Fully scalable solution for one or multiple sites

Backup redundancies preventing loss of data

3. Device connectivity via Netbiter gateways

Cloud-based management
services
Full suite of management tools at your fingertips.

Get instant access from


any location
You can gain access to your devices,
machines and installations from any device
(Laptop, iPAD, iPhone or any mobile device)
from any location just by using a standard
web browser.

Visualize, monitor and control through web dashboards

Configurable alarm management suite

Equipment diagnostics and data logging/trends

Instant or scheduled reporting functions

BMS linking and integration

Connectivity via Netbiter


gateways

Reduce equipment downtimes

Netbiter EasyConnect gets your devices online fast.

Configure alarm parameters for your devices


and equipment. Direct alarms and GPS
information are sent instantly to service staff
via SMS, or Email.

Reduce energy consumption

Plugnplay connectivity - no programming required!

Device connectivity via Ethernet, GSM or GPRS

Secure access through firewalls, No IT issues

A flexible remote management solution for Rockwell Automation


applications

Remotely start and stop industrial devices and equipment to save energy. Monitor facility parameters such as
power consumption or HVAC data. Gain an insight to how your devices are actually used in the field. Utilize
this data with future designs of more energy efficient industrial equipment.

The flexibility of Netbiter means that you can remotely monitor almost anything. You configure which parameters you want to
monitor. Regardless of industrial market, automotive, factory automation, building automation, oil and gas, renewable energy,
water treatment or marine industries, Netbiter can be used anywhere Rockwell Automation is active today.

Streamline service operations and improve customer service


Through remote monitoring your devices and equipment, you are able to cut back or scale down your service
operations. In addition, data stored on the Netbiter Argos data center can be incorporated into a BMS (Business
Management System) enabling you to offer improved customer service contracts.

Page 32
Save time, save energy, save resources

www.netbiter.com

Page 33
Save time, save energy, save resources

www.netbiter.com

Netbiter Remote management solution

Netbiter Remote management solution

Netbiter Argos Data Center

Netbiter EasyConnect Gateways

Online cloud-based hosting and management portal

Series of wired and wireless connectivity gateways


with automatic Netbiter Argos data center integration

With Netbiter Argos, HMS provides a FREE, professional


data center for gathering and storing information from
your equipment in the field.

Netbiter EasyConnect are small robust, remote


communication gateways designed to get your industrial
equipment and installations online fast!

Netbiter Argos presents you with a host of cloud


management features that enable you to visualize,
monitor and control your equipment in a fast and
efficient way.

The gateways are designed for industrial applications


and are available with GSM/GPRS wireless access or
Ethernet communication. Automatic integration with
the Netbiter Argos data center ensures easy web
based management of all your remote sites.

When to use

Configuration

Netbiter EasyConnect gateways


feature a plugnplay integration
making it possible to perform large
scale installations quickly without
being an IT network expert.

Used in conjunction with Netbiter


EasyConnect gateways the
Netbiter Argos data center stores
all your site information giving you
instant remote access at any time.
This can dramatically improve your
service operations and reduce
operational costs.

Order information
Version
Part No:
EC150 (Ethernet only)
EC220 (GSM/GPRS only)
EC250 (Eth/GSM/GPRS)

When requiring remote access


to device parameter data for
monitoring or control

To protect installations and site


assets
To reduce energy consumption
through installation optimization
or through equipment
diagnostics and data trending

Optional accessories
Cloud services for remote management

Argos hosting features

SIM card for wireless versions

Visualize, monitor and control equipment using web-based


dashboards

Secure socket layer encryption


(SSL)

Argos GPS Tool-kit

Use ready-made dashboards or design your own with


an included suite of design tools with drag and drop
functionality

Firewall-friendly connection to
Argos from Netbiter gateways
when using Ethernet

Additional power supplies

The integrated alarm management suite allows you to


configure alarm thresholds, direct alarms to service
personnel (SMS, E-mail) and get exact GPS coordinates
through the integrated Google Maps

Did you know?

Netbiter is an integrated part of an


award-winning web based energy
control system which won a
Swedish e-prize in 2011 by helping
to reduce energy consumption in
churches by 35%.

Diagnostics and data trends enable you to analyze field


data, spot deviations or view actual customer usage.
Data trending can also help optimize and reduce energy
consumption in your installations
Effective Geo-fencing and mobile asset management
through GPS tracking. Together with Netbiter GPS receivers,
it is possible to view the location of each device in the field
on a geographical map. Geo-fencing can create secure zones
around site equipment preventing theft

Argos can be integrated into almost any business application


such as CRM, ERP or SCADA systems

Argos also features a suite of management report functions


in PDF, docx, html, xml or xls formats which can be
automatically generated, exported or sent directly via e-mail

Exclusive Netbiter SIM cards


for Wireless GPRS versions
eliminates Ping access
attempts and therefore
reduces unnecessary GPRS
traffic
24/7 monitoring of the server
solution health

Redundant servers at different


geographical locations

Anti-theft protection systems

Fire detection systems

Redundant Internet
connections from different
Internet providers

Power backup systems


(generators)

*See www.netbiter.com for more information

Page 34
Save time, save energy, save resources

www.netbiter.com

Range of GSM antennas

Connectivity

Security

Antenna extension cable

Range of digital and analog of


I/O extenders

Instant Netbiter Argos connectivity on power-up via


Ethernet, GSM or GPRS networks.

Connectivity to field equipment via a serial RS-232/485


Modbus interface.

On-board I/O extends the EasyConnect gateways by

Breakthrough connectivity technology allows for safe,

Netbiter EasyConnect gateways offer


unique technology for secure access
to your industrial equipment behind
firewalls and via mobile GSM/GPRS
based communication networks.
The gateways eliminate the need
for public and fixed IP address, VPN
tunnels and expensive M2M specific
SIM cards.

secure access to industrial equipment behind firewalls,


without the need for IT expertise.

Netbiter SIM-cards

Eliminates the need for costly public and fixed IP

For EasyConnect gateways that

addresses, complicated VPN tunnels and expensive M2M


specific SIM cards.

use cellular
technology, HMS
offers a SIM card
with roaming
capabilities to a
large number of
operators around the world.

*See www.netbiter.com for more


information

Also available:
Netbiter WS range

The Netbiter WS100 and WS200


gateways give full access to
remote devices in a flexible and
user friendly way. The gateways
contain on-board web pages to
remotely monitor and control
devices connected to an Ethernet
LAN or via GSM/GPRS networks.

allowing sensors and additional equipment to be added to


the system.

For wireless versions, HMS offers a Netbiter specific SIM


card with roaming capabilities to a large number of cellular
operators around the world.

Pre-made manufacturer device templates can be saved and


uploaded to speed up installation with large-scale sites.

*See page 42 for mechanical and technical


specifications

Page 35
Save time, save energy, save resources

www.netbiter.com

remote management

When you need to minimize


scheduled or emergency on-site
service

NB1001
NB1000
NB1003

Anybus Embedded - Interchangeable Fieldbus and Ethernet connectivity solutions

Anybus Embedded - Interchangeable Fieldbus and Ethernet connectivity solutions

Connecting Devices

PROVEN AND TRUSTED INTERCHANGEABLE INTERFACES


INSTALLED IN MILLIONS OF INDUSTRIAL DEVICES WORLDWIDE

Anybus users estimate that they have


saved up to 70 % of the development
costs compared to in-house development

One development project gives


you access to all networks
During the development project, you design the Anybus
module into your product.
You implement the Anybus driver in your processor which
enables your product to exchange data with the Anybus
module. Your product can now participate on the chosen
network.

Anybus Embedded modules


For over 20 years, Anybus embedded modules have provided
ControlNet, DeviceNet and now EtherNet/IP connectivity
capabilities for all types of industrial devices.

Once you have implemented the Anybus module, your


device has full network interchangeability. Simply plug
in another Anybus module to offer your product to any
market or business segment.

Instant CIP and other network


connectivity with just one
development

Why Anybus?
By choosing Anybus, you make sure that you have the
latest industrial connectivity technology inside your
product. Anybus embedded solutions are built on HMSs
own network processors and combine low costs, flexibility
and low power consumption with the performance you
need.

It doesnt matter if you manufacture robots, drives, weight scales,


barcode scanners or any other industrial device.
Anybus modules will seamlessly integrate into your device and
enable you to connect to over 20 different industrial networks.
You choose the solution that meets your demands regarding
size, physical interfaces, performance, power consumption,
interchangeability and so on.

Since Anybus incorporates expertise gathered from


thousands of device implementations, plus original
technology from the network founders, you can rest
assured that you get a fast and easy design project, and
that there is proven technology inside your product.

With Anybus, you will get:


Global connectivity which will open up new markets for your
product.

Leif Malmberg, Product Line Manager,


Embedded Solutions, HMS

A faster ROI and shorter time to market.


A future-proof solution. Avoid worrying about new networks,
network upgrades, maintenance costs and conformance issues.

Get connected to:


AS-Interface

CANopen

CompoNet

EtherNet/IP

FL-net

Modbus Plus

Powerlink

PROFINET-IRT

BACnet MSTP

CC-Link

ControlNet

EtherCAT

Interbus

Modbus-RTU

PROFIBUS

PROFINET-IRT Fiber Optic

BACnet/IP

CC-Link IE Field

DeviceNet

FIPIO

Lonworks

Modbus-TCP

PROFINET-IO

Sercos III

Connecting Devices

Page
36

www.anybus.com

Connecting Devices

Page
37

www.anybus.com

Anybus Embedded - Interchangeable Fieldbus and Ethernet connectivity solutions

Anybus Embedded - Interchangeable Fieldbus and Ethernet connectivity solutions

Embedded CIP technology through


Anybus CompactCom

Embedded CIP technology through


Anybus-IC

Integrating ControlNet, DeviceNet or EtherNet/IP


network connectivity into your industrial devices

Integrating DeviceNet or EtherNet/IP network


connectivity into small industrial devices

The Anybus-CompactCom family provides instant


connectivity to any CIP or 17 other industrial networks
with just one fast, one-time development.

Anybus-ICs are small connectivity modules with a


size of only 9 cm. They are designed for integration
into small-sized devices with limited space for the
communication interface.

With CompactCom you can keep the same drivers and


configuration while switching between the different
form factors or networks. This flexibility makes
the CompactCom the most compelling alternative
to extensive in-house development.

HMIs
Drives
Weigh scales
I/O blocks
Temperature controllers
Valve manifolds

Used with automation devices such as:

Robot controllers
Micro PLCs
Bar-code scanners
Welding controllers
RFID applications

We know EtherNet/IP
At HMS, we take pride in

providing the highest


levels of network
functionality and
performance within
our Anybus products.

Technology such
as Dual-port
EtherNet/IP with
integrated switch
and with support
for announced
and beacon-based
DLR (Device level
ring) are some of
the latest EtherNet/
IP technology that
HMS integrates into our Anybus
product families.
Joakim Wiberg
EtherNet/IP Specialist at HMS

CHIP

Sensors

BRICK

Quick implementation that covers many networks and


flexible form factor make Anybus CompactCom a safe choice.
CompactComs unique generic interface knits together I/O,
parameters, and diagnostics functionality which creates total
transparency when it comes to the data exchange between the
network and the device.
Cost, size and performance optimized family of
communication interfaces for a wide range of industrial
automation devices

Provides instant connectivity to all CIP networks as well as


any other network through only one development

Switch networks or form factors and keep the same driver


and configuration
All new and future network updates and enhancements
maintained by HMS

Short in-design with free assistance from HMS ensures a fast


time to market

Pre-certified at ODVA for full interoperability and network


compliance

3.3 volt design with low power consumption and high data
throughput

EtherNet/IP versions available with an integrated 2-port switch


and for beacon-based DLR support

All modules available with our without plastic housing.

M12 connectors for IP65/67 available for DeviceNet & EtherNet/IP

Page
38

Welding machines

Weigh scales

I/O blocks

RFID applications

Network specific features

1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other

ControlNet

1 = BNC 2 = Fixed 3 = 256 byte


IN/OUT 4 = Redundancy available.
Galvanic isolated bus electronics. CIP
forwarding support.

DeviceNet

1 = 5.08 plug 2 = 125-500 kbit/s


3 = 256 byte IN/OUT
4 = Automatic Baud rate support.
UCMM Capable. CIP forwarding
support.

EtherNet/IP

1 = 2*RJ45 2 = 10/100 Mbit/s full/half


duplex 3 = 256 IN/OUT
4 = CIP forwarding support, 2-port
switch supporting announced and
beacon based DLR.

*See page 40 for mechanical and technical


specifications

Connecting Devices

Valve manifolds
LED signs

MODULE

Anybus CompactCom

Bar-code scanners

Module order information


Network version:
Part.No
ControlNet
ControlNet (no housing)
DeviceNet
DeviceNet (no housing)
EtherNet/IP 2-port
EtherNet/IP 2-port (no housing)

AB6220
AB6320
AB6201
AB6301
AB6224
AB6324

* CompactCom Brick solution allows for full


connector flexibility. CompactCom in Chip format
allows full integration into your PCB design. Contact
HMS for more information.

www.anybus.com

Core embedded Anybus


technology
Anybus network processors
provide cutting edge fieldbus
and Industrial Ethernet
communication which off-loads
your own microprocessor from all
communication tasks.
Integrated into existing Anybus
embedded and gateway products,
they allow for low cost, optimal or
high performance and a greater
degree of flexibility.

Anybus-IC

Network specific features

Choose Anybus-IC if you have limited space, if you require a very


simple integration or if you need to use special network
connectors for example M12 connectors to achieve IP65
rating.

1 = Total I/O, 2 = SCI I/O, 3 = SSC I/O, 4 = Baud


rate, 5 = Other

Very small size - ideal when space is an issue.

Contains all analog and digital components for full network


connectivity

Operates as a stand-alone device (I/O) or together with


another microcontroller

Serial Communication Interface (SCI) using a protocol


based on Modbus-RTU

DeviceNet

1 = 144 byte IN/OUT 2 = 128 byte


IN/OUT 3 = 16 byte IN/OUT
4 = 125-500 kbit/s
5 = Auto baud rate support, UCMM
Capable, Quick Connect

EtherNet/IP

1 = 144 byte IN/OUT 2 = 128 byte


IN/OUT 3 = 16 byte IN/OUT
4 = 10/100 Mbit/s full/half duplex
5 = IT functions

*See page 40 for mechanical and technical


specifications

Synchronous Serial Channel (SSC) for process data


communication using shift register chain

Order information
Network version:

Configuration and monitoring via a PC configuration port

Very low power consumption with wide temperature


coverage

DeviceNet
EtherNet/IP

IT functions in Anybus-IC EtherNet/IP version: Embedded


webserver, Email client and FTP server

Ethernet TCP/UDP/IP socket interface allowing customer


specific TCP/IP protocols

Pre-tested and verified for ODVA fieldbus/industrial


Ethernet conformance

Connecting Devices

Page
39

Part.No
AB6001
AB6003

www.anybus.com

embedded solutions

Used with automation devices such as:

Anybus-IC can be used with various network


connectors such as M12 or screw terminals which
makes it an ideal for devices that are used in harsh
industrial environments.

Anybus Embedded - Interchangeable Fieldbus and Ethernet connectivity solutions

Anybus Gateways - Protocol converters and network to network gateways

-IC

CompactCom

Communicator

X-gateway

CompactCom M30 modules


Technical Details - CompactCom C30 Modules

Technical Details

Dimensions (L W H) 525022 mm, 2.041.970.86


513716 mm, 2.014.460.63 (modules without housing)

Communicator RTU, Communicator DF1, Communicator RS-232/485


Protocol Modbus RTU Master, DF1, ASCII, Configurable protocols

Dimensions (L W H) 422115 mm
1.650.830.59

Protection class IP20

Max stations 31 (with RS485/422)

RoHS Compliance Yes

RoHS Compliance Yes

Module types Active modules: Includes parallel and serial application interfaces and full
industrial network functionality
Passive modules: Physical layer interface only providing transparent
pass-through for serial data
Application drivers Standard and Lite drivers available depending on host application
requirements

Application interface MIF (Monitor interface)


4.8 kbps-57.6 kbps
SCI (PROFIBUS, DeviceNet and CANopen) 4.8 kbps-625 kbps
SCI (Ethernet versions)
4.8 kbps-57.6 kbps
SSC
Discrete shift registers
Ethernet versions (IT functions) Transparent socket interface
FTP server
E-mail
Web server with SSI support

UL, cUL File number: E214107

Emission EN 61000-6-4 EN55011 Radiated emission, EN55011 Conducted emission


Immunity EN 61000-6-2 EN61000-4-2 Electrostatic discharge, EN61000-4-3 Radiated immunity,
EN61000-4-4 Fast transients/burst, EN61000-4-5 Surge immunity,
EN61000-4-6 Conducted immunity

Current consumption DeviceNet


PROFIBUS
CANopen
Ethernet versions

Current comsumption Less than <250 mA, (2-port 2xRJ45) <500 mA, ControlNet <1 000 mA

Environmental Characteristics
Operating temp -40 to 70 oC, -40-158 oF
-40 to 85 oC, -40-176 oF (modules without housing)
-40 to 85 oC, -40-176 oF (max storage temperature)

80 mA
150 mA
150 mA
250 mA

Environmental Characteristics RTU, DF1, RS-232/485


Operating temp 0 to 55 oC, 32 to 131 oF
Storage temp -40 to 85 oC, -40 to 185 oF
Relative Humidity 0-95 % non condensing

If you want a fully


integrated on-chip solution
within your PCB design
CompactCom
30-series

Anybus CompactCom C30


Available now!

If you want a complete


interface where you add
your own connectors
Anybus CompactCom B30
Available now!

Installation altitude Up to 2 000 m

Environmental Characteristics Communicator CAN

Carrier board and resource CD

Operating temp -25 to 55 oC, -13 to 131 oF


Storage temp -40 to 85 oC, -40 to 185 oF

Module

Relative Humidity 5-95 % non condensing

If you want a complete


ready-made plug-in
module

Installation altitude Up to 2 000 m

Dimensions (LWH) 1207527 mm, 4,722,951,06


Protection class IP20, NEMA rating 1
Enclosure material PC ABS, UL 94
Installation position Any
EN 50022

Power 24 VDC +/- 10 %


Current consumption Max 300 mA, Typical 200 mA

X-gateway CANopen Environmental Characteristics


EN 60950-1

Operating temp -25 to 55 oC, -13 to 131 oF

IEC 60068-2-1
IEC 60068-2-2

Storage temp -40 to 85 oC, -40 to 185 oF

IEC 60068-2-1
IEC 60068-2-2

Relative Humidity 5-95 % non condensing

IEC 60068-2-30

Installation altitude Up to 2 000 m

X-gateway Modbus TCP Client/Master Technical Details

Standard

Weight 160 g, 0,35 lb


Dimensions (LWH) 11035101 mm, 4,331,383,98
Protection class IP20, NEMA rating 1
Enclosure material PC ABS, UL 94 VO
Installation position Horizontal
Mounting DIN rail (357,5/15) or Wall Mount

EN 50022

X-gateway Modbus TCP Electrical Characteristics

Anybus CompactCom M30


Available now!

Power 24 VDC +/- 10 %

(NP30-based)

Current consumption Max 300 mA, Typical 200 mA

Proven and trusted Anybus


technology targeting general
automation.

CompactCom
40-series

Standard

X-gateway CANopen Electrical Characteristics

Short circuit protection Yes


Galvanic isolation on subnetwork Yes

IEC 68-2-30

Weight 150 g, 0,33 lb

Mounting DIN rail (357,5/15)

Reverse voltage protection Yes

Humidity 5-95 % non-condensing

Brick

EN 61000-6-4
EN 61000-6-2

Current consumption Max 300 mA, Typical 100 mA

Starter kit

New Anybus CompactCom Options

ISA 12.12.01

Hardware Characteristics

Storage temperature -40 to +85 oC


-40 to +185 oF

Serial carrier board including two modules, driver and resource CD

UL 508 Ind. Cont. Eq.

Power 24 VDC +/- 10 %

Operating temperature -40 to +85 oC


-40 to +185 oF

Starter kit

EN 50022

Electrical Characteristics

Environmental Characteristics

Humidity 5-95 % non-condensing

Relative Humidity 5-95 % non condensing

IEC 68-2-1, IEC 68-2-2


IEC 68-2-1, IEC 68-2-2

Installation altitude Up to 2 000 m

X-gateway CANopen Technical Details

CE 2004/108/EC

Power 5 VDC, +/- 5 %

Power requirements 3.3 VDC, +/- 0.15 VDC

Storage temp -40 to 85 oC, -40 to 185 oF

Enclosure material PC ABS, UL 94

Hazardous Locations CLASS 1, DIVISION 2, GROUPS A, B, C


AND D, T4

Electrical Characteristics

Electrical Characteristics

Operating temp 0 to 65 oC, 32 to 149 oF (for all other networks)

Protection class IP20, NEMA rating 1

UL File number: E203225

Immunity EN 61000-6-2 EN61000-4-2 Electrostatic discharge


EN61000-4-3 Radiated immunity
EN61000-4-4 Fast transients/burst immunity
EN61000-4-5 Surge immunity
EN61000-4-6 Conducted immunity

Current consumption Max 300 mA, Typical 200 mA

X-gateway Environmental Characteristics

Dimensions (LWH) 1207527 mm, 4,722,951,06

Certifications

Emission EN 61000-6-4 EN55016-2-3 Radiated emission

CE - Declaration of Pre-Conformity

Power 24 VDC +/- 10 %

Standard

Mounting DIN rail (357,5/15)

CE - Declaration of Pre-Conformity

Network conformance Yes: Pre-certified for full fieldbus and Industrial Ethernet network
conformance

Chip

Baud rate 20 kbit/s - 1 Mbit/s

Installation position Any

Pre-tested and verified for fieldbus Yes


and Ethernet conformance

EN 50022

X-gateway Electrical Characteristics

Physical standards RS232/422/485

UL, c-UL File number: E214107

Certifications

Mounting DIN rail (357,5/15)

Max stations 31 (with RS485/422)

Weight 150 g, 0,33 lb

Certifications

Network status led outputs Integrated on front with housing, via application interface without housing

Installation position Any

Protocol Configurable CAN 1.0, 2.0A and 2.0B based protocols

Technical Details

Network node address and baud Accessible via the shift register interface (SSC) and via SCI interface
rate input

Ethernet features 1 and 2-port versions, transparent socket interface, integrated 2-port
switch, IT functions (FTP server, E-mail, Web server with SSI support)

Enclosure material Aluminium

Communicator CAN

Network status LED outputs Accessible via the shift register interface (SSC) and via SCI interface

Drive Profile support DeviceNet and EtherNet/IP

Protection class IP20, NEMA rating 1

Physical standards RS232/422/485

Module connector DIL-32

Application interfaces Parallel Dual Port Ram (dpram): 8 bit data bus, 14 bit address bus
Asynchronous serial interface with Baudrate between 19.2 kbps - 625
kbps

Standard

Weight 500 g, 1,100 lb


Dimensions (LWH) 12611042 mm, 4,964,331,65

Serial baud rate 1,2-57,6 kbit/s

Galvanically isolated network Yes


interface

Galvanically isolated network interface Yes

X-gateway Technical Details

X-gateway Modbus TCP Environmental Characteristics


Anybus CompactCom C40
Concept release

Anybus CompactCom B40


Concept release

Anybus CompactCom M40


Concept release

(NP40-based)

High performance industrial


communication supporting
motion and sync applications.

Operating temp -25 to 55 oC, -13 to 131 oF

IEC 60068-2-1
IEC 60068-2-2

Storage temp -40 to 85 oC, -40 to 185 oF

IEC 60068-2-1
IEC 60068-2-2

Relative Humidity 5-95 % non condensing

IEC 60068-2-30

Installation altitude Up to 2 000 m

Certifications (All versions)


UL File number: E203225

Contact HMS for more details....

Connecting Devices

Hazardous Locations* CLASS 1, DIVISION 2, GROUPS A, B, C AND D, T4

Page
40

www.anybus.com

UL 508 Ind. Cont. Eq.


ANSI/ISA 12.12.01-2000

ATEX* Zone 2, Cat 2

EN60079-15
EN60079-11

CE 2004/108/EC

EN61000-6-4
EN61000-6-2

Page 41
Industrial networking made easy!

www.anybus.com

Netbiter Remote management solution

EasyConnect

Always Free Tech Support


At HMS, technical support is FREE of charge and available from all HMS offices and
distributors around the world. HMS has CIP specialized development engineers, global technical
support teams, and CIP-trained sales, all dedicated to increasing your automation performance,
raising productivity, decreasing product downtime and reducing your costs and efforts.

TECHNICAL
SPECIFICATIONS

Rockwell Automation Knowledge Base Program

Description

EC250

EC220

EC150 + EC150-M

Order code

NB1003

NB1000

NB1001 Plastic Housing


NB1002 Metal Housing

10/100 Mbit/s + failover mode

10/100 Mbit/s

Quad band GPRS Class 12


850/900/1800/1900 MHz

Quad band GPRS Class 12


850/900/1800/1900 MHz

E-mail, SMS

E-mail, SMS

E-mail, SMS

Ethernet
GSM/GPRS
Alarms

In addition to HMS online technical support, HMSs products can also be found via Rockwells
own Knowledge Base Support Program. For more information visit: https://rockwellautomation.
custhelp.com/

Support contacts

The first line of support

HMS - America
Tel: +1 312 829 0601
Email: us-support@hms-networks.com

The HMS Academy is an umbrella for all HMS training


and e-learning activities. Through our Academy trainings,
videos and other materials, you can learn more about
industrial communication and get a better insight into
HMS products and solutions.

HMS - China
Tel : +86 (0)10 8532 3023
Email: cn-support@hms-networks.com

Relay output
(max 24 V, AC/DC, 1A)
Digital inputs
(Isolated, max 24 V DC)
Analog inputs
(PT100, 0-10 V or 0-20 mA)

Analog output (0-10 V)

Serial port #1

RS-232 up to 115,2 kbit/s

RS-232 up to 115,2 kbit/s

RS-232 up to 115,2 kbit/s

Serial port #2 (isolated)

RS-485 up to 115,2 kbit/s

RS-485 up to 115,2 kbit/s

RS-232/RS-485 up to 115,2 kbit/s

SMA female

SMA female

Modbus-RTU, ASCII, Modbus TCP

Modbus-RTU, ASCII

Modbus-RTU, ASCII, Modbus TCP

HMS - India
Tel: +91 20 40111201
Email: in-sales@hms-networks.com

Wall mounting / DIN rail

NO / YES (optional)

YES / YES (optional)

Mechanical dimensions

90x 70 x 58 mm

92x 115 x 25mm

NO/YES
YES/YES (metal, optional)
90 x 70 x 58mm
92 x 115 x 25mm (metal)

HMS - Italy
Tel : +39 039 59662 27
Email: it-support@hms-networks.com

Operating temperature

-30 to +65 C

-30 to +65 C

-40 to +65 C -40 to +75 C (metal)

9-24 V DC

9-24 V DC

9-24 V DC

3W

2W

2W

CE, CULUS, (FCC/IC, PTCRB


ATEX / Haz.Loc pending)

CE, CULUS, FCC/IC, PTCRB


(ATEX/Haz.Loc pending)

CE, (ATEX/Haz.Loc pending)

Antenna connector
Protocols

Power supply
Power consumption
Certifications

HMS - France
Tel: +33 (0)368 368 033
Email: fr-support@hms-networks.com
HMS - Germany
Tel: +49 721 989777-301
Email: ge-support@hms-networks.com

HMS - Japan
Tel: +81 (0)45 478 5340
Email: jp-support@hms-networks.com
HMS - Sweden (HQ) + HMS UK
Tel : +46 (0)35 17 29 20
Email: support@hms-networks.com

Webinars
Spend an hour with an industrial communication specialist
to learn how to connect different fieldbus and industrial
Ethernet and wireless networks. HMS webinars are held
free of change via Webex in various languages and at
different locations and time-zones.
How-to application notes
Step-by-step instructions on how to carry out specific
actions using the different Anybus products.
How-to videos
Screen recordings of how to configure Anybus and Netbiter
gateways. Follow these to get up and running
in a few minutes.
Hands-on training
Get hands-on training on HMS products and technologies.
The trainings are run at an HMS office or at your location
if you prefer!

Stay connected!
HMS provides a 3-year product
guarantee on all Anybus and
Netbiter gateways

Page 42
Save time, save energy, save resources

www.netbiter.com

We regularly send out information specific


to a HMS product line via both e-mail and social media.
Sign-up on our websites and stay informed about the
latest HMS product developments, industry news, case studies,
tips and tricks and much more.

Connecting Devices

Page
43

www.anybus.com

Anybus Communicator - Protocol converter gateways

Anybus X-gateway - Network to network gateways

Case Study: Protocol conversion

Case Study: Network to network

Rockwell Automation and HMS provide intelligent


solutions for the Guangzhou Metro Line 5 BAS system

Network to network and PLC system connectivity for


C.I.A Automation and Robotics

Solution:
Country:
Company:
Summary:


Solution:
Country:
Company:
Summary:


Device connectivity using a custom serial protocol


China
Guangzhou Metro
Anybus Communicator enables
communication between different
devices in Guangzhou Metros surveillence
system and the ControlNet network.

Network to Network connectivity


Italy
C.I.A. Automation and Robotics
Anybus X-gateways provide robots
with connectivity to several
industrial networks such as for
example PROFIBUS and DeviceNet.

System integration made easy for


Chinese subway line.

Automation: a must to be able to


compete on the global market.

Guangzhou Metro Line in China connected various monitoring


equipment to ControlNet using solutions from Rockwell
Automation and the Anybus Communicator from HMS.

C.I.A. Automation and Robotics has extensive experience in the


field of advanced automation, proposed as a strategic tool to
increase the competitiveness of Italian companies in the world.
It offers advanced technologies such as laser scanners,
stereoscopic vision equipment and systems that can reproduce a
die and copy it directly, automatically recomposing the scanning
scattergrams, a very differentiating solution.

The Guangzhou Metro Line 5 spans 40 kilometres east to


west through Guangzhou City. The line includes 24 stations
and has a capacity of transporting a whopping 50 million
passengers per day.
Like all modern subway lines, the Guangzhou Metro Line 5
has a comprehensive monitoring system overlooking
ventilation, air conditioning, water supply, drainage,
elevators etc.
The Challenge
The Metro Line system has numerous points with large amounts
of data. The monitoring system has a total of about 210,000 I/O
points. The entire project was forecasted to contain 280,000
points, of which 70,000 points were allocated to the BAS system.
Consequently, system integration required a great deal of work
and deadlines were tight 24 stations were to be simultaneously
opened. Indeed, never before in the country had so many stations
been opened at one time.

BAS Metro Line 5 System Overview


The Solution
The Rockwell Automation system is widely used in the rail
transport field. The central segment of the Metro Line 5 BAS
system uses ControlLogix Redundancy Controllers from the
Rockwell Automation Integrated Architecture platform. Together
with the Anybus Communicator ControlNet gateway, devices
with a serial RS-485 interface with a custom protocol were easily
integrated into the system.
The BAS system was implemented one month before Guangzhou
Metro Line 5 was successfully commissioned. The system
integration was carried out by Beijing-based HollySys Automation
Technologies.

The Challenge
We have produced automation systems, testing benches
and machinery managed by PLCs and Scada systems for the
foodstuffs, chemical, glass, plastics, metalworking, metallurgical
and automobile industries, explained Mr Angelo Galimberti,
the sole director of C.I.A. Automation and Robotics. As well as
many other applications, such as robotised stations for servomechanical machinery, palletisation lines, assembly lines and
processing lines such as for handling, cutting, hot and cold
pressing, welding, tacking, induction, brazing, deburring, etc.
As most of C.I.A Automation and Robotics applications are
specific, they have to interface different kinds of devices in their
automatic systems that use different communication protocols.
The Solution
We have produced various equipment with PROFIBUS master
PLCs and DeviceNet slaves, or with DeviceNet master PLCs and

PROFIBUS slaves, and so on, said Galimberti. HMS products


have enabled us to resolve and simplify a number of these
applications. The protocols we use the most are PROFIBUS and
DeviceNet, which cover almost 90% of the cases we deal with
involving robots and PLCs.
The Result
He added that C.I.A. was satisfied with the performance of HMS
products and that no major problems were encountered. I
believe that we will continue to find space for HMS products in
our future applications, whenever we need to interface system
parts that use different communication protocols, concluded
the director of C.I.A. Automation & Robotics.

The Communicator required no programming and was configured to use a uniform method to access sub-systems; thereby, saving us a great deal of

This need for flexibility in diverse design conditions led us to try HMS products, which we appreciated immediately because they are particularly

time in the project implementation stage.

comprehensive and can be used to interface different kinds of machines, even pre-existing machinery.

Zhao Feng, HollySys project manager of the Guangzhou Metro Line 5 project.

Angelo Galimberti, Director of C.I.A. Automation and Robotics.

Page 44
Industrial networking made easy!

www.anybus.com

Page 45
Industrial networking made easy!

www.anybus.com

Netbiter Remote management solution

Connecting Devices

Case Study: Remote management

WORK WITH THE WORLDS NUMBER ONE CHOICE FOR


INDUSTRIAL COMMUNICATION

Solution:
Country:
Company:
Summary:

Remote monitoring and control


USA
Bauer Compressors
Netbiter monitors compressors
in order to reduce downtime and
optimize gas consumption.

Remote management helps improve


customer care and service.
Bauer Compressors is a leading manufacturer of compressor
systems that offer commercial and industrial solutions for oxygen,
natural gas (CNG), and some noble gases. Having a turnover (not
consolidated) of over 140 million Euro worldwide, the BAUER
KOMPRESSOREN Group has become a global player in the high
pressure sector. A world market share of over 70% for breathing
air applications underpins BAUERs technological leadership.
The Challenge
Bauer recently launched a new product line that includes remote
monitoring capability a feature that is new to the compressor
market. In selecting the remote monitoring vendor, Bauer
wanted an easy-to-implement solution for the site installations,
and a solution that provides easy central management of all the
monitored sites. We wanted to implement remote monitoring
on our compressors in order to reduce downtime and optimize gas
consumption, explains Tommy Michaelides, Bauer Compressors
Inc., the US subsidiary.
The Solution
Bauer chose the Netbiter Solution, consisting of GSM-enabled
remote devices and the Netbiter Online Management Portal. This
industrial grade remote management solution enables access
to mobile and stationary installations for applications such as
monitoring, control, alarm management, data logging, reporting,
location tracking and service call. It is primarily made for
remote monitoring, but control is also possible: for instance PLC
parameters can be changed.

Facts about HMS





Operations in 10 countries:
Sweden, Germany, USA,
Japan, Denmark, China, Italy,
France, UK and India.

Customers in more than


50 countries.
With this web
interface, operators
can analyze the
problem thanks to
a PC and a smart
This is a very modular solution we
can duplicate easily on any other
phone. Some are
plant, whatever the compressor or
using an iPhone,
the PLC.
and it is really
Tommy Michaelides
appreciated by our
customers, explains
Tommy Michaelides. This is a very modular solution we can
duplicate easily on any other plant, whatever the compressor or
the PLC. New development is minimized and
our objective is to offer this option more on our different ranges of
products.
Bauer studied the offers from several vendors but the choice was
made for HMS: it was less expensive and it appeared to be more
proven. Most of all, as it is a long term project for Bauer, it appears
to us to be the most promising offer: the web system is attractive
and it is open to all PLCs and any kind of fieldbus concludes
Tommy Michaelides.
The Result
This added-value option is very new in our industry. Return
on investment for our customers should be very short. Firstly,
it simplifies maintenance operations. Second, it also enables
quicker intervention when a problem occurs. Thus, downtimes are
reduced and gas consumption can also be optimized. Thats very
valuable as gas is expensive.

Page 46
Save time, save energy, save resources

www.netbiter.com

Head office in Halmstad,


Sweden.

Network connectivity expertise at


your service
With more than 2 million communication modules installed globally, HMS
Industrial Networks is indisputably the worlds number one provider of
industrial connectivity solutions.
Customers include most major industrial
automation companies such as
Rockwell Automation, Siemens, Mitsubishi,
Yaskawa, Schneider Electric,
Toshiba, Panasonic, ABB and Hitachi.

Founded in 1988.

Focus on what you do best

More than 240 employees.

By partnering with HMS, you get access to the knowledge of some of the
worlds leading experts on industrial connectivity experts who are with
you all the way from the design project and throughout the product life cycle.

Listed on NASDAQ-OMX
Nordic Exchange in
Stockholm.

With HMS as your communication partner, you will not have to worry about
network upgrades, new technologies or conformance testing. HMS handles
all connectivity issues, so you can focus on your core business.

Partnership with HMS is for the long-term


We work closely with our customers to offer expertise and know-how. We
help you broaden your market and stay up-to-date when it comes to network
connectivity. Indeed, many of our customers regard HMS as their internal
development department for industrial communication.

Netbiter monitors compressors in order to reduce


downtime and optimize gas consumption.

Get in touch with us, and we'll tell you more about how to get connected.
Staffan Dahlstrm
Chief Executive Officer, HMS

HMS Industrial Networks


Through Anybus and Netbiter technology, HMS Industrial Networks provides reliable solutions to connect devices to
any major industrial network, as well as remote management solutions. Anybus is a globally recognized brand, offering
customers a competitive advantage in all types of applications. HMSs knowledgeable staff along with distributors and
partners in over 50 countries worldwide, are there to help you and your business increase productivity and performance
while lowering cost and time to market.

www.anybus.com - www.netbiter.com

HMS Industrial Networks - worldwide


HMS - France
HMS - Sweden (HQ)
Tel : +46 (0)35 17 29 00 (Halmstad HQ) Tel: +33 (0)368 368 034
Tel: + 46 (0)35 17 29 24 (Vsters office) Email: fr-sales@hms-networks.com
Email: sales@hms-networks.com

HMS - Italy
Tel : +39 039 59662 27
Email: it-sales@hms-networks.com

HMS - China
Tel : +86 (0)10 8532 3183
Email: cn-sales@hms-networks.com

HMS - Germany
Tel: +49 721 989777-000
Email: ge-sales@hms-networks.com

HMS - Japan
Tel: +81 (0)45 478 5340
Email: jp-sales@hms-networks.com

HMS - Denmark
Tel: +45 35 38 29 00
Email: dk-sales@hms-networks.com

HMS - India
Tel: +91 20 40111201
Email: in-sales@hms-networks.com

HMS - UK
Tel: +44 (0) 1926 405599
Email: uk-sales@hms-networks.com

HMS - United States


Tel: +1 312 829 0601
Email: us-sales@hms-networks.com

Anybus and Netbiter are registered trademarks of HMS Industrial Networks AB, Sweden, USA, Germany and other countries. Other marks and words belong to their respective companies. All other
product or service names mentioned in this document are trademarks of their respective companies.
Part No: MMA500 Version 1 09/2012 - HMS Industrial Networks - All rights reserved - HMS reserves the right to make modifications without prior notice.

S-ar putea să vă placă și