iFaceSeriesInstallationGuide

Version1.0
DateSep2009
AboutthisGuide
This guide provides actual installation instructions only. For information
regardinguserinstructions,pleaserefertoiFaceSeriesUserManual.
iFaceSeriesInstallationGuideV1.0
I
Content
1SystemConfiguration.............................................................................. 1
1.1Viewofoperationpanel ................................................................ 1
1.2Theillustrationofsystemconstruction .......................................... 2
1.3Thesketchmapofcommunication................................................ 3
2Installation.............................................................................................. 4
2.1Doorsensorconnection ............................................................... 6
2.2Exitbuttonconnection.................................................................. 6
2.3TimeRingconnection .................................................................. 7
2.4Doorlockconnection.................................................................... 8
2.5Ethernetconnection................................................................... 12
2.6RS232connection...................................................................... 13
2.7RS485connection...................................................................... 14
2.8 WiegandOutputConnection....................................................... 15
2.9PowerConnection...................................................................... 16
3.Others................................................................................................. 17
3.1Reset......................................................................................... 17
3.2 Antidismantlebutton.................................................................. 17
3.3Uflashdiskusing....................................................................... 18
3.4ReserveBattery......................................................................... 19
iFaceSeriesInstallationGuideV1.0
1
Powerkey
Resetkey
USB
Loudspeaker
Batteryslot
Touchscreen
Camera
Baseline
FingerprintSensor
LEDlight
1SystemConfiguration
1.1Viewofoperationpanel
Power TCP/IP USB
iFaceSeriesInstallationGuideV1.0
2
1.2Theillustrationofsystemconstruction
iFaceSeriesInstallationGuideV1.0
3
PC
PC
1.3Thesketchmapofcommunication
1FingerprintmachinedirectlyconnectswithPCthroughRS232or
TCP/IP.
2FingerprintmachineconnectswithPCthroughRS485network.
3FingerprintmachineconnectswithPCthroughTCP/IPnetwork.
TCP/IP
TCP/IP
TCP/IP

RS485Switch
RS232

RS485
Switch
TCP/IP orRS232
PC
iFaceSeriesInstallationGuideV1.0
4
Power TCP/IP USB
2Installation
Caution: Do not to connect peripheralequipment before the
power of the device is cut down, otherwise it is possible to
damagethedevicebadly.
Pleasefollowinstructiontoconnectperipheralequipment
Doorsensorconnection(Sensor,GND)
Exitbuttonconnection(Button,GND)
Alarmconnection(NC2,COM2,NO2)
Doorlockconnection(NC1,COM1,NO1)
Ethernetconnection(RJ451,RJ452,RJ453,RJ456)
RS232connection(232T,232R,GND)
RS485connection(485A,485B)
Wiegandoutputconnection(WD0,WD1,GND)
Powerconnection(+12V,GND)
iFaceSeriesInstallationGuideV1.0
5
Thedefinitionofterminalconnection
Fromlefttoright
1 NO2 ConnecttoCableBellNOterminal
2 COM
2
ConnecttoCableBellCOMterminal
3 NC2 ConnecttoCableBellNCterminal
Tieup
together
4 Sens
or
ConnecttoDoorsensor
5 GND ForDoorsensorandreleasebutton
6 Butto
n
ConnecttoReleasebutton
Tieup
together
7 NO1 ConnecttoLockNCterminal
8 COM
1
ConnecttoLockCOMterminal
9 NC1 ConnecttoLockNOterminal
Tieup
together
10 485 ConnecttoRS485B
11 485+ ConnecttoRS485A
Tieup
together
12 GND Connect to RS232 and Weigand
GND
13 TXD ConnecttoRS232TXD
14 RXD ConnecttoRS232RXD
Tieup
together
15 WD0 ConnecttoWeigandoutWD0
16 WD1 ConnecttoWeigandoutWD1
17 SGN
D
Connectto screenwire
Tieup
together
18 GND ConnecttoPowerGND
19 +12V ConnecttoPower+12v
Tieup
together
iFaceSeriesInstallationGuideV1.0
6
2.1Doorsensorconnection
The door sensor is used to detect the door openclose state ,
terminal can monitor if the door has been unauthorized open
throughthedoorsensor,atthistimeitcanoutputaalarmsignal,
moreover, terminal can trigger prompt warning if the door is not
closetightly.
2.2Exitbuttonconnection
Theexitbuttonisinstalledforindooroperation.Whentheswitch
of the button is close, the door will open. The distance is
approximately1400mmfromgroundtoexitbuttonbottom. Make
surethattheexitbuttonpositionistoaligncorrect,uprightandthe
connection is accurate and reliable. (Unused exposed end of
cable should be cut off, and use insulating tape to wrap it.)Pay
attention to electromagnetic disturbance.(For example: The light
switch,thecomputerandsoon)
DoorSensor
Button
PowerSupply
iFaceSeriesInstallationGuideV1.0
7
2.3TimeRingconnection
Connecttheelectricalbelltothefingerprintmachine,when arrivethe
appointtime,thefingerprintmachinewillsendsignalto triggerrelay
TheterminalsupportsbothNormalOpenbellsandNormalClose
bellsatthesametime.
NormalOpenbells
NormalClosebells
iFace
Bell
iFace
Bell
Powersupply
Powersupply
iFaceSeriesInstallationGuideV1.0
8
2.4Doorlockconnection
The way of installing door lock depends on the type of lock and
local condition. Internal resistor which comes from long distance
transfer should be taken into consideration when selecting the
cableofelectricpower.Thedoorlockshouldbeinstalledreliable
and stable .Ensure the wiring is correct. For the strike lock and
electromagnetic lock, you should pay attention to positive and
negativeterminalconnection.Theunusedbareendofwireshould
be cut off and use insulating tape to wrap it. The delay time of
strikelockisadjustableaccordingtodifferentconditions.
Select electric lock it is better to use strike lock for the two
direction opening glass door (both open to inside or outside
direction),forthesingleopeningwooddoorincompanyinternal,
we recommend to use magnetic lock, the magnetic lock also be
called as electric magnetic lock,. The magnetic lock is more
reliablethanthestrikelock,butthestrikelockismuchsaferthan
themagneticlock.Inthesmalllivingcommunity,itisbettertouse
strikelockandmagneticforcelock.Theelectriccontrollockgives
out higher noise the electric control lock is commonly used to
buildingcommunication.Nowthereisasoundlesselectriccontrol
lockwhichisabletobeapplied.Pleasepayattention,thelockis
madeofironandeasyrust,soyoumustbewareofnotexposingit
to water or harsh condition, there are some other electric locks
available,wedontrecommendyoutousethem.
Connectwithelectriclock
The NormalOpen lock is open when the power is on. The
NormalClose lock is closed when power is on. The machine
iFaceSeriesInstallationGuideV1.0
9
supportsbothofthetwokindsoflocksatthesametime.Theway
oflockconnectionchangeswiththetypeoflock.ForNOlock,the
NO terminal will be used for NC lock, the NC terminal will be
used.
ThisaccesscontrolmachineispoweredbyDC12Vandwork
current400mA.IfthelockworkelectricpowerisDC12Vandthe
work current is less than 1000mA, the fingerprint machine and
lock are able to be powered by one adapter together, please
refertotable1,2.
In the following three cases, we recommend that fingerprint
machineandlockarepoweredseparately.
1)The working voltage of the lock is DC12V, but the current
differenceofthefingerprintmachineandthelockdoesntexceed
1A.
2)ThelockvoltageisnotDC12V.
3) The distance between lock and fingerprint machine is too
far.
iFaceSeriesInstallationGuideV1.0
10
Picture1Powerbyonesupply
Picture2powerbyonesupply
NCLOCK
NOLOCK
DC12V
DC12V
iFaceSeriesInstallationGuideV1.0
11
Picture3Theterminalandlockpoweredbyindependentadapters
Picture4Theterminalandlockpoweredbyindependentadapters
NOLOCK
NCLOCK
LockPower
LockPower
DC12V
DC12V
iFaceSeriesInstallationGuideV1.0
12
2.5Ethernetconnection
TheterminalprovidetwowaysconnectEthernet.
1TheterminalconnectwithPCthroughcrosscable
2The terminal connect with PC through network and HUB to
createalocalnetwork
IP192.168.1.100
SubMask 255.255.255.0
IP192.168.1.101
Mask255.255.255.0
Switch
PC
PC
iFace
iFaceSeriesInstallationGuideV1.0
13
iFace
2.6RS232connection
TheterminalconnectwithPCthroughRS232
NoteDont upload or download facial module through RS232,
becausethelargedatawilleffectthetransferspeed.
PCSerialPort
iFaceSeriesInstallationGuideV1.0
14
PC

2.7RS485connection
TheterminalconnectwithPCthroughRS485
NoteDont upload or download facial module through RS485
becausethelargedatawilleffectthetransferspeed.
RS485Switch
RS232

RS485
iFaceSeriesInstallationGuideV1.0
15
2.8WiegandOutputConnection
ThedevicehasWiegandoutputfunction,canconnectthemajorityaccess
controllersonthemarket,atthistimeitisusedasareader
Note
1Thedistancebetweendeviceandaccesscontrollerorcardreader
shouldntbeover90meters(Ifalongerdistanceisneededorthereis
interferenceinusingenvironment,pleaseuseWiegandsignaldelay.).
2) To ensure the stability oftheWiegandsignal,the device must share the
GNDwithcontrollerorWeigandreader.
3)IfthedistanceofWiegandoutputor485communicationisover90meters,
inordertoreducetheinterferencecausedbythelongdistance,itis
suggestedtousethecablewithshieldandconnecttheshieldcabletothe
SGNDterminal.
iFaceSeriesInstallationGuideV1.0
16
2.9PowerConnection
ThedevicesworkingvoltageisDC12V,withworkingcurrent
500mA,standbycurrent50mA.hasprovidedtwowaystoconnect
power,pleaseselectonereferringtotheactual.
1Terminalconnection,Makesuretheconnectionasthe
diagram(Dontconnectthepolesinreverse.).
2Slot connection :Insert the plug of DC12V adapter into the
powerslotdirectly.
PowerSlot
DC12V
Terminalconnection Slotconnection
iFaceSeriesInstallationGuideV1.0
17
3.Others
3.1Reset
Due to operation error or other accidence, which leads the
machinenottowork,youcanrestartmachinethroughresetkey
takeasmalltoolwhichdiameterisnomorethan2mm
findresetmarkofresontheleftsmallholeonthebottomof
device,seefollowingfigure
Usethetoolplugintotheholerefertothepictureonright,then
plugout.Themachineisabletorestar
3.2Antidismantlebutton
Antidismantle button is on middle of device, whose function is
Reset
iFaceSeriesInstallationGuideV1.0
18
realized by backcover pressing the antidismantle button.When
thedeviceisbeingdismantled,itwillsendaalarmsignalthrough
theterminal.
3.3Uflashdiskusing
thereisaminiportofUSB,pleaseseefigurecircleontheleft
USBcanbeusedtouploadanddownloaddatabyUdisk,
Antidismantlebutton
iFaceSeriesInstallationGuideV1.0
19
3.4ReserveBattery
Workprinciple
Before use,make sure the reserve battery is installed properly.
Wheneverusepowersupplyorreservebattery,youneedpress
power key to turn on the terminal. In normal state, When the
power cut down, the reserve battery will switch into discharge
state to power on the terminal, In power off state, when the
powercutdown,thereservebatterywillnotswitchintodischarge
statetopoweron.Ifyouwanttopowerontheterminal,youneed
presspowerkeytoturnontheterminal.
USBPort
iFaceSeriesInstallationGuideV1.0
20
Technicalparameter
Chargetime Lessthan4H Discharge
time
Morethen5.5H
Working
environment
050 Relative
humidity
1090
Storing
environment
Please store the battery when the discharge
capacityisfull.,andtheenvironmentis205
Cycleage Cycletimesofchargeanddischarge300times
Notice
There is a danger of battery exploding,leak,fever,fire,break,if
youdontreadthenoticecarefully.
DoNotuseitover50
DoNotinversepolarityconnection
DoNotputthebatteryintowaterorletittogetwet
Do Not use and store battery near heatgenerating
machine(suchasfireorheater)
Batteryslot
Powerkey
iFaceSeriesInstallationGuideV1.0
21
DoNotthrowbatteriesintofireorhotbattery
Do Not use wire or other metal short the positive and
negativeterminal.

S-ar putea să vă placă și