Sunteți pe pagina 1din 19

Table-of-Contents Web Registration

U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com


Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
2
Air/Gas Analysis
AI
Air Sampling
Specifications
Apex Sampling Pumps
Large LCD of flow rate, volume sampled, elapsed sample time, and temperature
l
Digital circuitry for precise and constant control of flow rate
l
Long-term stability between calibrations
Versatile pumps offer a broad measurement range to cover a variety of sampling applications.
Three-button controls create user-friendly interface for operation. LCD can also be customized for your
preferred data view. Apex pumps are designed to deliver real-time readings. Apex Pro pumps add data
storage (100 events) and download via infrared RS-232 interface and software (sold separately). Both
models are available with AA alkaline or rechargeable NiMH batteries.
Whats included: four AA alkaline batteries (models 86543-00, -10) or NiMH battery and 115 VAC charger
(models 86543-02, -12).
RZ-86543-50 Low-flow controller/CPU for sample volumes 5 to 750 mL/min .................................................
RZ-86543-51 Infrared interface cable and software for use with Apex Pro models 86543-02, -12 .................
Data displayed: flow rate, volume
sampled, elapsed sample time,
temperature, operating mode,
program details
Operating temperature: 41 to 104F
(5 to 40C)
Battery life
AA alkaline: varies by user settings
NiMH: 34 hours
Tubing ID:
1
4" (6.4 mm)
Dimensions:
3
1
2"W x 5
3
4"H x 1
3
4"D
86543-00
Catalog
number
Description Flow range
Low flow range,
constant flow

Pump wt Power Price


RZ-86543-00
Apex pump 0.8 to 5 L/min 5 to 750 mL/min
17.8 oz
(0.5 kg)
Four AA alkaline batteries
RZ-86543-02 NiMH with 115 VAC charger
RZ-86543-10
Apex Pro pump 0.8 to 5 L/min 5 to 750 mL/min
17.8 oz
(0.5 kg)
Four AA alkaline batteries
RZ-86543-12 NiMH with 115 VAC charger

Requires purchase of Low-flow controller 86543-50 (sold separately below).


Call our Application
Specialists for more
information on air
sampling equipment.
847-549-7600
Specifications
Data displayed: sample time, alarm
Operating temperature: 32 to 105F (0 to 40C)

Tubing ID:
1
4" (6.4 mm)
Dimensions: 6"W x 4"H x 5-
1
2"D
Allegro T100M Air Sampling Pump
Expanded flow range capabilities
l
Sample volumes from 3 to 30 L/min
l
Suitable for use with impactors
Rotary vane sampling pump features broader 3 to 30 L/min sampling range. Built-in,
adjustable flowmeter (5 to 50 L/min) allows easy display and adjustment to flow rate. This
pump is specifically designed for use with cassettes and is also an excellent choice for work
with impactors for impaction sampling. Order optional impactor or optional adjustable
stand (sold separately below) for easy sample collection.
Whats included: flowmeter, in-line filters, muffler jar, and 6 feet of vinyl tubing.
86444-10 shown with stand 86444-51 and
86444-50 sampler
RZ-86444-50 Impactor sampler ......................................................................................................
RZ-86444-51 Optional adjustable stand ........................................................................................
Catalog number Description Flow range Pump wt Power Price
RZ-86444-10 T100M air sampling pump 3 to 30 L/min 10 lb (5.0 kg) 115 VAC
Instruments are
not included.
Customize
your case
with prescored
Pick-N-Pluck foam
Unbreakable Instrument Cases
Protect your valuable instrumentationcases are absolutely air- and water-tight. They
are constructed of high-impact polypropylene and feature ABS plastic latches.
A
1
4"-thick neoprene O-ring guarantees a water- and dust-proof seal. Each case includes
a Pick-N-Pluck foam linercustomize your case by simply removing pieces of foam.
Models 40460-92 and -94 also include adjustable handle and rolling wheels
for easy transport.
Catalog
number
Interior
dimensions
Exterior
dimensions
Price
RZ-40460-80 8
1
2"L x 6"W x 3
3
4"H 9
1
4"L x 7
3
4"W x 4
1
2"H
RZ-40460-82 9
1
2"L x 7
1
2"W x 4
1
2"H 10
3
4" x 9
3
4"W x 5"H
RZ-40460-84 12
1
4"L x 9
1
4"W x 5
1
4"H 13"L x 12"W x 6"H
RZ-40460-86 17"L x 11
3
4"W x 6"H 18
1
2"L x 15
1
4"W x 6
7
8"H
RZ-40460-88 22"L x 17"W x 8"H 24
1
4"L x 19
1
2"W x 9"H
RZ-40460-92 22"L x 17"W x 12
1
2"H 24
3
4"L x 19
1
2"W x 13
3
4"H
RZ-40460-94 29"L x 7
3
4"W x 10
1
2"H 32
1
2"L x 20
1
2"W x 11
1
4"H
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
3
Air/Gas Analysis
AI
Air Sampling
Sampling Pump Kits
Reduce flow rates to as low as 0.001 L/min with the optional low flow modules
GilAir 3 is a compact yet full-featured sampler.
GilAir 5 is a double-diaphragm pump with a larger
capacity battery to handle higher flow rates. Clock
features run and hold functions.
Whats included: air boss (bag fill adapter), tubing,
tool kit, rechargeable NiCd battery; 120 or 230 VAC
charger; and filter cassette holder.
Approval
UL: Class I, Div 1, Groups A, B, C, D; Class II,
Groups E, F, G; Class III CENELEC (86276-81 and
86276-87 only). CE.
Built-in rotameter on
GilAir 3 and 5
Low-Flow Modules customize your pump for sampling volumes from 0.001 to 0.75 L/min.
RZ-86276-84 Low-flow module, constant flow ..................................................................................................................
RZ-86276-85 Low-flow module, multiflow .........................................................................................................................
230 VAC only
Data displayed: elapsed time,
low battery, flow fault
Operating temperature:
32 to 113F (0 to 40C)
Battery life: 8 to 10 hrs at
3 L/min (full charge)
Tubing ID:
1
4" (6.4 mm)
Dimensions:
3
11
16"W x 4"H x 2"D
86276-86
86276-80
Low-flow module
86276-84
l
Gilian pumps with automated
constant flow control ensure
accuracy in high flow ranges
l
EMI/FRI protection prevents
interference from plant
operations
l
See-through inlet filter housing
protects pumps from dirt and
debris while allowing easy
inspection
Gilibrator-2 calibration system provides a
convenient and highly automated way to
check almost any commercial air sampling
pump. The system consists of an electronic
base which is used with any one of three
sizes of wet cells, and includes everything
needed to calibrate sampling pump air flows
from 0.001 to 30 L/min.
Whats included: three (low, standard, and
high) interchangeable wet cells, control base
with rechargeable NiCad battery pack, DC
charger / AC power supply, tubing, hard-
shell carrying case, and a thermal dot matrix
printer.
Gilibrator-2

Diagnostic Calibration System


Calibrate air flow from 0.001 to 30 L/min with 1% wet cell accuracy
86276-96
Specifications
Specifications
Accuracy:
1% of rdg
230 VAC
units only
Cell dimensions:
2"W x 4"H x 2"D (low);
2
1
2"W x 6"H x 2
11
16"D (standard);
3
1
2"W x 8"H x 3
3
4"D (high)
Specifications
Data displayed: flow rate, run time, total volume sampled
Operating temperature: 32 to 113F (0 to 45C)
Battery life: 8 to 11 hours
Tubing ID:
1
4" (6.4 mm)
Dimensions: 3
3
16"W x 4
15
16"H x 2
1
16"D
Weight: 2 lb (1.0 kg)
3500 Air Sample Pump Kit
Pump is accurate, reliable, and easy-to-use
l
Holds calibration for 30 days, even through temperature or flow rate changes
l
Calibrate in one location and run tests in another without fear of resulting error!
Pump also displays total run time so you
know when to recalibrate. The NiMH
battery eliminates memory-related
data loss. A green indicator light flashes
when the pump is operating within 5% of
the set flow rateyou know at a glance it
is working.
Whats included: air boss, 36"L tubing,
tool kit, NiMH battery pack, AC charger,
and filter cassette kit.
Approval
UL: Class I, Div 1, Groups A, B, C, D; Class II,
Groups E, F, G; Class III Temp Code 3C.
cUL: Class I, Div 1, Groups C, D; Class II,
Groups F, G; Class III Temp Code 3C
CENELEC (EEx ib llb T4). CE.
Catalog
number
Flow range
Low flow range,
constant flow
Low flow range

,
multiflow
Power Price
RZ-86276-70
20 to 3500 mL/min 700 to 3500 mL/min
20 to 750 mL/min
at 18" 3" H
2
O
115 VAC
RZ-86276-71 230 VAC

Requires use of low-flow adapter 86276-73. Does not display live flow in this mode.
Display shows
flow rate, run time,
and total volume
sampled.
86276-70
RZ-86276-73 Low-flow adapter for multiflow sorbent sampling volumes
from 20 to 750 mL/min ....................................................................................................................
Catalog number Description High flow range

Low flow range

, constant flow Low flow range

, multiflow Pump wt Power Price


RZ-86276-80
GilAir 3 0.75 to 3 L/min
0.001 to 0.50 L/min,
to 25" (640 mm) H2O
0.001 to 0.75 L/min
at 18" 3" (460 80 mm)
H2O (constant pressure)
21 oz (0.6 kg)
115 VAC
RZ-86276-81 230 VAC
RZ-86276-86
GilAir 5 0.75 to 5 L/min 22.5 oz (0.7 kg)
115 VAC
RZ-86276-87 230 VAC

Flow control is 5% of set point.

0.001 to 0.75 L/min flow rates require low-flow module 86276-84 or 86276-85.
Catalog number Flow range Power Price
RZ-86276-96
0.001 to 0.25 L/min; 0.02 to 6 L/min; 2 to 30 L/min
115 VAC
RZ-86276-97 230 VAC
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
4
Air/Gas Analysis
AI
Air Sampling / Accessories
C
10370-01
Gas Sampling Accessories
A Scienceware

Gas Washing Bottle consists of a 250-mL polypropylene graduated


cylinder with extended base, a 38-mm vinyl stopper with
1
4" OD tubes, and a removable
gas dispersion fitting with 70-m porosity polyethylene disc. Maximum pressure is 0.5 psi.
B Gas Dispersion Tube linear polyethylene bell-mouthed fitting has a sealed 70-m
porosity disc.
C Glass Gas Sampling Bulbs are designed for the collection and storage of environmental
samples. Top cap with a PTFE/silicone septum lets you withdraw analytical samples. Both
ends have a 4-mm valve plug and are ground to accept
3
8" ferrules and hand compressible
fittings for a gas-tight seal. GPI thread size: 13-425.
A
06652-00
B
06614-25
Economical choice for noncorrosive gases such as
CO, SO
2
, H
2
S, radon, and mercaptans
l
Strong seams for added durability
l
Resists temperatures up to 400F
All standard and light-blocking models have either
an on/off valve (
3
16" nickel-plated brass hose barb)
or a silicone septum in polypropylene housing;
dual-valve models have both. Max temp:
225F (107C) continuous use, 400F (204C)
intermittent use. Individually sealed in
a dust-protected outer bag.
Light-Blocking Tedlar PVF Bags
Double-wide seamed bags are ideal for light-sensitive applications.
Dual-Valve Tedlar PVF Bags
Single-wide seamed bags have both on/off and septum valves
for convenient mixing.
Tedlar

PVF Gas Sampling Bags


Standard Tedlar PVF Bags
Single-wide seam; available in 2-mil and 4-mil thick styles.
FEP Sampling Bags
Reusable bags resist damage from radiation and
corrosive gases
l
Extra rugged5 mil thick
l
Resists temperatures up to 200F
Available in two stylesbags with on/off valve (
3
16" nickel-plated
brass hose barb) or with a silicone septum in a polypropylene
housing. Max temp: 200F (93C). Thickness: 5 mil. Individually
sealed in a dust-protected outer bag.
Tedlar PVF bag with
septum valve
Light-blocking Tedlar
PVF bag with on/off
valve
Simply twist on/off valves
to control gas introduction
or release.
Septum valves permit more
precise workuse a syringe
to introduce and remove
known sample volumes.
FEP bag
with septum valve
On/off valve Septum valve
Volume Dimensions
Cat. no. Price Cat. no. Price
Standard 2-mil bags
RZ-01409-10 RZ-01409-20 0.3 L 6"L x 6"W
RZ-01409-11 RZ-01409-21 1.6 L 9"L x 9"W
RZ-01409-12 RZ-01409-22 3.8 L 12"L x 12"W
RZ-01409-13 RZ-01409-23 8.1 L 15"L x 15"W
RZ-01409-14 RZ-01409-24 20.3 L 18"L x 18"W
RZ-01409-15 RZ-01409-25 37.7 L 24"L x 24"W
RZ-01409-16 RZ-01409-26 85.7 L 30"L x 30"W
Standard 4-mil bags
RZ-01409-31 1.6 L 9"L x 9"W
RZ-01409-32 3.8 L 12"L x 12"W
RZ-01409-33 8.1 L 15"L x 15"W
On/off valve
Volume Dimensions
Cat. no. Price
RZ-01409-51 1.6 L 9"L x 9"W
RZ-01409-52 3.8 L 12"L x 12"W
RZ-01409-53 8.1 L 15"L x 15"W
Catalog number Volume Dimensions Price
RZ-01409-90 0.3 L 6"L x 6"W
RZ-01409-91 1.6 L 9"L x 9"W
RZ-01409-92 3.8 L 12"L x 12"W
RZ-01409-93 8.1 L 15"L x 15"W
RZ-01409-94 20.3 L 18"L x 18"W
RZ-01409-95 37.7 L 24"L x 24"W
RZ-01409-96 85.7 L 30"L x 30"W
On/off valve Septum valve
Volume Dimensions
Cat. no. Price Cat. no. Price
RZ-01430-10 RZ-01430-50 0.5 L 6"L x 6"W
RZ-01430-20 RZ-01430-60 1.2 L 6"L x 10"W
RZ-01430-30 RZ-01430-70 4.7 L 12"L x 12"W
RZ-01430-40 RZ-01430-80 50.0 L 24"L x 36"W
Tedlar PVF dual-valve
bag with on/off and
septum valves
Key Catalog number Description Volume Dimensions Qty Price
A RZ-06652-00 Gas washing bottle 250 mL Accepts tubes up to
1
4" OD 1 ea
B RZ-06614-25 Gas dispersion tube 12"L x 1" OD at bell,
3
58" OD tube 4/bg
C
RZ-10370-00
Glass gas sampling bulb
125 mL 11
1
2"L x 3
1
2"W
1 ea

RZ-10370-01 250 mL 11
3
4"L x 3
3
4"W
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
5
Air/Gas Analysis
AI
Gas Detection, Detector Pumps / Tubes
Pump Kit and
Gas Detection Tubes
Easy, one-handed operation
l
Wider diameter tubes with well-spaced graduation
marks are easier to read
l
Two-year shelf life
The accuro

gas detector pump is a manually operated


bellows pump that draws a calibrated 100-mL sample
through the short-term gas detection tubes
(order tubes separately). Provides fast, accurate,
reliable results in just seconds.
Whats included: pump, tube opener, spare parts kit,
rubber caps (10/pk), and nylon case.
86514-00
Pump Kit
Gas Detection Tubes
Catalog
number
Description
Sample
volume
Price
RZ-86514-00 accuro

pump kit 100 mL


Catalog
number
Gas/vapor Range TLV
Price/
box of 10
RZ-86514-10 Acetic acid 5 to 80 ppm 10 ppm
RZ-86514-12 Acetone 10 to 12,000 ppm 750 ppm
RZ-86514-61 Alcohol
25 to 5,000 ppm methanol 200 ppm

50 to 4,000 ppm propanol 400 ppm
100 to 5,000 butanol 50 ppm
25 to 2,000 ethanol 1000 ppm
RZ-86514-13 Ammonia 0.05 to 10% 25 ppm
RZ-86514-14 Ammonia 5 to 700 ppm 25 ppm
RZ-86514-15 Ammonia 0.25 to 3 ppm 25 ppm
RZ-86514-16 Arsine 0.05 to 3 ppm 0.05 ppm
RZ-86514-18

Benzene 0.5 to 10 ppm 0.5 ppm


RZ-86514-20 Benzene 15 to 420 ppm 0.5 ppm
RZ-86514-22 Carbon dioxide

0.1 to 1.2% 5000 ppm


RZ-86514-24 Carbon dioxide 1 to 20% 5000 ppm
RZ-86514-26 Carbon monoxide 2 to 300 ppm 25 ppm
RZ-86514-27 Carbon monoxide

5 to 700 ppm 25 ppm


RZ-86514-28 Carbon monoxide 0.1 to 7% 25 ppm
RZ-86514-30 Chlorine 0.2 to 30 ppm 0.5 ppm
RZ-86514-29 Chloroform 2 to 10 ppm 10 ppm
RZ-86514-53 Ethyl acetate 200 to 3,000 ppm 400 ppm
RZ-86514-54

Ethylene 0.2 to 5 ppm asphyx


RZ-86514-31

Ethylene glycol 10 to 180 mg/m


3
100 mg/m
3

RZ-86514-32

Ethylene oxide 1 to 15 ppm 1 ppm


RZ-86514-34 Formaldehyde 2 to 40 ppm 0.3 ppm
RZ-86514-55 Hexane 50 to 3,000 ppm 50 ppm
RZ-86514-35 Hydrochloric acid 1 to 10 ppm 5 ppm
RZ-86514-58 Hydrocyanic acid

2 to 150 ppm 5 mg/m


3

RZ-86514-59 Hydrogen fluoride 0.5 to 90 ppm 3 ppm
RZ-86514-60 Hydrogen sulfide 0.2 to 5 ppm 10 ppm
RZ-86514-37 Hydrogen sulfide 2 to 200 ppm 10 ppm
RZ-86514-38 Hydrogen sulfide

1 to 200 ppm 10 ppm


RZ-86514-39 Hydrogen sulfide 100 to 2,000 ppm 10 ppm
RZ-86514-40 Hydrogen sulfide 2 to 40% 10 ppm
RZ-86514-62 Mercury 0.05 to 2 mg/m
3
0.025 mg/m
3

RZ-86514-64

Methyl bromide 3 to 100 ppm 5 ppm


RZ-86514-42 Nitrogen dioxide

0.5 to 25 ppm 3 ppm


RZ-86514-65 Nitrous gases 2 to 100 ppm
25 ppm NO

3 ppm NO3
RZ-86514-44 Oxygen 5 to 23%
RZ-86514-46 Ozone 0.05 to 1.4 ppm 0.05 to 1 ppm
RZ-86514-56
Petroleum
hydrocarbons
10 to 300 ppm
RZ-86514-57
Petroleum
hydrocarbons
100 to 2,500 ppm
RZ-86514-66 Sulfur dioxide 1 to 25 ppm 2 ppm
RZ-86514-50 Toluene 50 to 400 ppm 50 ppm
RZ-86514-67 Trichloroethylene 2 to 250 50 ppm
RZ-86514-68 Vinyl chloride 1 to 50 5 ppm
RZ-86514-52 Xylene 10 to 400 ppm 100 ppm

Models contain 10 twin tubes (5 tests/box).

SEI certified by Safety Equipment Institute


Diffusion Tubes
Direct-read tubes identify workers exposure
to chemicals
Direct-reading diffusion tubes are used
specifically for personal exposure monitoring.
These tubes do not require the use of a gas
detector pump because the contaminant
molecules pass into the tube by diffusion
processes and are brought into contact with
the reagent systems. Exposure levels are
easily read by the markings on the side of
the tube. Use tube holder 86515-50 to clip
diffusion tube onto shirt collar or pocket.
Catalog
number
Chemical
Standard range Price/bx
of 10 1 hour 4 hours
RZ-86515-51 Acetic acid 10/a-D 10 to 200 ppm 1.3 to 25 ppm
RZ-86515-52 Ammonia 20/a-D 20 to 1500ppm 2.5 to 200 ppm
RZ-86515-53 Butadiene 10/a-D 10 to 300 ppm 1.3 to 40 ppm
RZ-86515-54 Carbon dioxide 500/a-D 500 to 20,000 ppm 65 to 2500 ppm
RZ-86515-55 Carbon dioxide 1%/a-D 1 to 30 % 0.13 to 4 %
RZ-86515-56 Carbon monoxide 50/a-D 50 to 600 ppm 6 to 75 ppm
RZ-86515-57 Ethanol 1000/a-D 1000 to 25,000 ppm 125 to 3100 ppm
RZ-86515-58 Hydrochloric acid 10/a-D 10 to 200 ppm 1.3 to 25 ppm
RZ-86515-59 Hydrocyanic acid 20/a-D 20 to 200 ppm 2.5 to 25 ppm
RZ-86515-60 Hydrogen sulfide 10/a-D 10 to 300 ppm 1.3 to 40 ppm
RZ-86515-61 Nitrogen dioxide 10/a-D 10 to 200 ppm 1.3 to 25 ppm
RZ-86515-62 Perchloroethylene 200/a-D 200 to 1500 ppm 25 to 200 ppm
RZ-86515-63 Sulfur dioxide 5/a-D 5 to 150 ppm 0.7 to 19 ppm
RZ-86515-64 Toluene 100/a-D 100 to 3000 ppm 13 to 380 ppm
RZ-86515-65 Trichloroethylene 200/a-D 200 to 1000 ppm 25 to 125 ppm
RZ-86515-50 Tube holder with clip. Pack of 3 ......................................... /pk
Tube 86515-55 shown
with holder 86515-50
GO
to page(s)

14691472
Protect workers from airborne
contaminants. See our wide
selection of respirators and masks.
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
6
Air/Gas Analysis
AI
Gas Detection, Detector Tubes / Pumps
Manual Gas Sampling Pump
Springless design for accurate
50- and 100-cc sample volumes
l
Flow finish indicator signals stroke completion
l
Built-in tube tip breaker for clean
break every time
Hand-operated precision piston pump works with
RAE System gas detection tubes (sold separately
above). Features flow-finish indicator to signal
stroke completion, stroke counter, and built-in
tube-tip breaker.
Whats included: wrist strap.
Automatic
Gas Sampling Pump
Provides continuous or fixed-volume sampling
from 50- to 950-cc in 50-cc increments
l
Ensure error-free sample drawing
with this intrinsically safe automatic
gas sampling pump
l
LCD indicates sampling status, selected
flow rate, or sample volume
Pump accepts RAE System detection tubes
(sold separately above).
Whats included: calibration tube, inlet adapter
replacement, rechargeable NiCd battery pack
with built-in charger, and adapter for four AA
alkaline batteries (not included).
Approval: UL and cUL classified as intrinsically
safe for Class 1, Division 1, Groups A, B, C, and
D environments; EX 1211CT2 (Europe); CE
Gas Detection Tubes
Sharp, clear color change for unambiguous measurements
l
Precalibrated, maintenance-free tubes accurately and
reproducibly indicate toxic gas concentrations.
Two-year shelf life. Box of 10 tubes.
Catalog number Gas Range TLV (ppm) Price/box
RZ-86260-50 Acetone 0.1 to 2% 750
RZ-86260-51 Ammonia 5 to 100 ppm 25
RZ-86260-52 Ammonia 25 to 500 ppm 25
RZ-86260-53 Ammonia 1 to 15% 25
RZ-86260-54 Benzene 0.5 to 40 ppm 10
RZ-86260-55 Benzene 5 to 100 ppm 10
RZ-86260-56 Carbon dioxide 0.05 to 1% 5000
RZ-86260-57 Carbon dioxide 1 to 20% 5000
RZ-86260-70 Carbon dioxide 300 to 5000 ppm 5000
RZ-86260-58 Carbon monoxide 5 to 100 ppm 25
RZ-86260-59 Carbon monoxide 20 to 500 ppm 25
RZ-86260-60 Carbon monoxide 0.2 to 4% 25
RZ-86260-71 Chlorine 0.5 to 8 ppm 0.5
RZ-86260-61 Chlorine 5 to 100 ppm 0.5
RZ-86260-73 Hydrocarbons 50 to 1000 ppm
RZ-86260-74 Hydrogen chloride 1 to 20 ppm 5
RZ-86260-75 Hydrogen fluoride 0.5 to 20 ppm 3
RZ-86260-76 Hydrogen sulfide 0.2 to 2 ppm 10
RZ-86260-62 Hydrogen sulfide 2.5 to 60 ppm 10
RZ-86260-77 Hydrogen sulfide 10 to 120 ppm 10
RZ-86260-78 Hydrogen sulfide 25 to 250 ppm 10
RZ-86260-63 Hydrogen sulfide 50 to 800 ppm 10
RZ-86260-79 Hydrogen sulfide 100 to 2000 ppm 10
RZ-86260-64 Hydrogen sulfide 0.1 to 2% 10
RZ-86260-65 Hydrogen sulfide 2 to 40% 10
RZ-86260-80 MEK 0.02 to 6% 200
RZ-86260-66 Nitrogen oxides 1 to 50 ppm
RZ-86260-81 Phosphine 5 to 50 ppm 0.3
RZ-86260-82 Sulfur dioxide 2 to 30 ppm 2
RZ-86260-67 Sulfur dioxide 5 to 100 ppm 2
RZ-86260-68 Sulfur dioxide 200 to 4000 ppm 2
RZ-86260-83 Toluene 10 to 300 ppm 50
RZ-86260-84 Water vapor 2 to 10 lbs/MMCF
RZ-86260-85 Water vapor 6 to 40 lbs/MMCF
RZ-86260-69 Xylene 10 to 200 ppm 100
Catalog number Description Sample volume Price
RZ-86260-00
Manual gas
sampling pump
50 and 100 cc
Catalog number Description Sample volume Price
RZ-86260-10
Automatic gas
sampling pump
50 to 950 cc
RZ-09376-01 Replacement batteries,
AA. Pack of 4 ................................................... /pk
GO
to page(s)

2
Safely store gas detection equipment for
transport and use in the field. See our rugged,
water-tight Pelican

cases on page 7.
T
echnical info
Easy-to-use colorimetric tubes:
1. Break off the tube tips at both ends.
2. Insert tube into pump (not included) and
draw sample.
3. Read the concentration directly from
the printed scale.
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
7
Air/Gas Analysis
AI
CMS Analyzer / Single-Gas Detectors
CMS Analyzer and Chips
Eliminate user error for a consistent measurement every time
l
Digital display of gas
concentration eliminates
ambiguous results
l
Internal recorder stores up to
50 measurements with
time/date stamp
Just load a CMS gas specific
chip into the bottom port
of the analyzer. Easy-
to-use, three-step slide
switch allows analyzer to
take measurements. Gas
concentration is displayed in
seconds with digital readout.
Operates on four AA batteries
(included). Chips contain
10 tests each and are sold
separately at right.
Approval: UL and CSA listed
intrinsically safe for class
1, Div 1, Groups A-D, T4;
CENELEC EEx ib IIC T4; MSHA
86513-00
CMS Chips
Catalog number Gas/vapor Range Price
RZ-86513-08 Acetic acid 2 to 50 ppm
RZ-86513-09 Acetone 40 to 600 ppm
RZ-86513-10 Ammonia 2 to 50 ppm
RZ-86513-12 Ammonia 100 to 2000 ppm
RZ-86513-14 Benzene 10 to 250 ppm
RZ-86513-16 Carbon dioxide 200 to 3000 ppm
RZ-86513-18 Carbon dioxide 1 to 20%
RZ-86513-20 Carbon monoxide 15 to 150 ppm
RZ-86513-22 Chlorine 0.2 to 10 ppm
RZ-86513-23 Ethylene oxide 0.4 to 5 ppm
RZ-86513-24 Formaldehyde 0.2 to 5 ppm
RZ-86513-25 Hydrogen cyanide 2 to 50 ppm
RZ-86513-26 Hydrogen sulfide 0.2 to 5 ppm
RZ-86513-28 Hydrogen sulfide 2 to 50 ppm
RZ-86513-30 Nitrogen dioxide 0.5 to 25
RZ-86513-32 Oxygen 1 to 30%
RZ-86513-34 Ozone 25 to 1000 ppb
RZ-86513-35 Petroleum hydrocarbons 20 to 500 ppm
RZ-86513-36 Petroleum hydrocarbons 100 to 3000 ppm
RZ-86513-37 Sulfur dioxide 5 to 150
RZ-86513-38 Toluene 10 to 300 ppm
RZ-86513-39 Vinyl chloride 10 to 250 ppm
RZ-86513-40 Xylene 10 to 300 ppm
RZ-09376-01 Replacement batteries, AA. Pack of 10 ................... /pk
Specifications for Analyzer
Power: four AA batteries (included)
Dimensions: 3
1
2"W x 8"H x 1
3
4"D
Instrument wt: 25.6 oz (0.7 kg)
Catalog number Description Price
RZ-86513-00 CMS analyzer
MSHA
Pac 3000/5000 Single-Gas Monitors
Bump test moderequires user to expose monitor to gas periodically or prior to use
The monitor features a robust, rubber-coated weatherproof polymer housing that will stand up
to the typical abuse in an industrial environment. Monitor is maintenance free and can be easily
operated using two buttons. Its small size makes it comfortable and easy to wear all day on a
belt, breast pocket, or lapel. A loud audible alarm, two bright visual alarms, and strong vibrating
alarms alert you to hazardous concentrations of gas.
The Pac 3000 only shows gas formula until the measured value exceeds alarm set point. The
Pac 5000 will continuously display gas concentrations, and is equipped with an event logger
which will store up to 60 alarm activations or other events.
Approval: UL and cUL classified intrinsically safe in Class I, Div. 1,
Groups A, B, C, D, E, F, G T4; ATEX; CE
Catalog
number
Sensor Range Resolution
Alarm set points
Price
Low High
Pac 3000 single-gas monitors
RZ-86515-04 O2 0 to 25% 0.1% 19.50% 23.50%
RZ-86515-00 CO 0 to 500 ppm 1 ppm 35 ppm 50 ppm
RZ-86515-02 H2S 0 to 100 ppm 1 ppm 10 ppm 20 ppm
Pac 5000 single-gas monitors
RZ-86515-14 O2 0 to 25% 0.1% 19.50% 23.50%
RZ-86515-10 CO 0 to 500 ppm 1 ppm 35 ppm 50 ppm
RZ-86515-12 H2S 0 to 100 ppm 1 ppm 10 ppm 20 ppm
Specifications
Alarm: 90 dB at 12 inches (audible/visible/vibrating)
Sensor life: 2 years
Functions: actual concentration, operating time
Display: LCD
Power: lithium battery (included)
Battery life: 2 years
86515-04
Dimensions: 2
1
2"W x 3
1
4"H x
3
4"D
Instrument wt: 4 oz (0.1 kg)
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
8
Air/Gas Analysis
AI
Single-Gas Detectors
ToxiRAE II Personal Gas Monitors
No expiration dateturn on and off
to preserve battery and sensor life
Monitors provide continuous measurement
and display of toxic gas concentration
levels. Readings include STEL, TWA, peak,
and high/low values. Varying audio alarm
signals different alarm conditions to cue
appropriate level of response. Durable,
impact-resistant ABS housing is IP55-rated
and performs well even with RFI interference.
Single button monitor is easy to operate, with
simple calibration procedure and adjustment
of factory settings.
Whats included: belt clip/hard hat adapter,
wrist strap, calibration adapter, and batteries.
Approval: UL and cUL classified intrinsically safe
in Class I, Div. 1 Groups A, B, C, D T6, ATEX, CE
86538-02
Catalog
number
Sensor Range Resolution
Alarm set points
Price
Low High
RZ-86538-04 O
2
0 to 30% 0.1% 19.50% 23.50%
RZ-86538-00 CO 0 to 500 ppm 1 ppm 35 ppm 200 ppm
RZ-86538-02 H
2
S 0 to 100 ppm 1 ppm 10 ppm 20 ppm
RZ-86538-06 SO
2
0 to 20 ppm 0.1 ppm 2 ppm 10 ppm
RZ-86538-08 NO 0 to 250 ppm 1 ppm 25 ppm 50 ppm
RZ-86538-10 NO
2
0 to 20 ppm 0.1 ppm 1 ppm 10 ppm
RZ-86538-12 Cl
2
0 to 10 ppm 0.1 ppm 0.5 ppm 5 ppm
RZ-86538-14 HCN 0 to 100 ppm 1 ppm 4.7 ppm 50 ppm
RZ-86538-16 NH
3
0 to 50 ppm 1 ppm 25 ppm 50 ppm
Specifications
Alarm: 90 dB at 4 in. (audible/visible/vibrating)
Sensor life: 2 years
Functions: high/low, STEL, TWA, peak,
low-battery indicator
Display: LCD
Power: two AA lithium batteries
Battery life: 2 years
Dimensions: 2"W x 3
1
2"H x 1"D
Instrument wt: 3.6 oz (0.1kg)
GasAlertClip

Extreme Personal Monitors


Compact and easy to useno maintenance required!
Specifications
Approval:
UL: Class I, Div. 1, A, B, C, D; Class I, Zone 0,
Group IIC CENELEC: EEx ia IIC Operated by an advanced microcontroller and electrochemical
sensor, the GasAlertClip Extreme monitors provide continuous,
maintenance-free operation for up to two years from the day of
activation. These disposable battery-operated monitors are easy to
usesimply clip the meter to your pocket or belt and go!
View important gas-reading information
and detector life remaining data on the
full-feature LCD display. No calibration is
required for H
2
S or CO; O
2

self calibrates.
Monitors feature audible, visible, and
vibrating alarms. Each monitor is
encased in a shock- and water-resistant
ABS enclosure and offers RFI protection
to withstand the rigors of industrial and
field use.
GasAlertClip3 Extreme offers the same
great features plus a three-year sensor.
Whats included: alligator belt clip and
calibration cap.
Alarm: 95 dB at 1 ft
(audible/visible/vibrating)
Sensor life: 2 years
Functions: low-battery indicator
Display: alphanumeric status panel
Power: 3 V lithium battery (included)
Dimensions: 2"W x 3
1
4"H x 1"D
Instrument wt: 4 oz (0.1 kg)
86383-03
Catalog
number
Sensor Range Accuracy
Alarm set points
Price
Low High
GasAlertClip with 2-year sensor
RZ-86383-05 O
2
0 to 30% 0.1% 19.5% 23.5%
RZ-86383-01 CO 0 to 300 ppm 1 ppm 35 ppm 200 ppm
RZ-86383-03 H
2
S 0 to 100 ppm 0.3 ppm 10 ppm 15 ppm
RZ-86383-07 SO
2
0 to 100 ppm 1 ppm 5 ppm 10 ppm
GasAlertClip3 Extreme with 3-year sensor
RZ-86383-11 CO 0 to 300 ppm 1 ppm 35 ppm 200 ppm
RZ-86383-09 H
2
S 0 to 100 ppm 0.3 ppm 10 ppm 15 ppm
GasAlert

Extreme Single-Gas Detectors


Simple four-button operation
The easy-to-read LCD shows continuous real-time
gas concentrations and instrument status. The
detectors feature simple auto zero and calibration
procedures. All models feature a 90 dB alarm
and bright LED to warn you of the presence of
hazardous conditions. The LOW, HIGH, and TWA
alarms have adjustable set points; peak values can
be displayed on demand. The full function self-test
verifies sensor, circuit, and battery integrity and
activates the audible/visual/vibrating alarms each
time you turn on the instrument.
Whats included: pocket/belt clip, test cap and hose,
and 3 V lithium battery.
Approval: UL Class I, Div. 1, Groups A, B, C, D; CE
Specifications
Alarm
Audible: 95 dB at 1 ft
Visual: dual red LEDs
Optional: vibrating
Sensor life: 2 years
Functions: TWA, peak, adjustable alarm
set points, low battery indicator
Display: backlit LCD
Power: 3 V lithium battery (included)
Battery life: 2 years
Dimensions: 2"W x 3
3
4"H x 1"D
Instrument wt: 4 oz (0.1 kg)
81991-13
Catalog
number
Sensor Range Resolution
Alarm set points
Price
Low High
RZ-81991-15 O
2
0 to 30% 0.1% 19.5% 23.5%
RZ-81991-11 CO 0 to 999 ppm 1 ppm 35 ppm 200 ppm
RZ-81991-13 H
2
S 0 to 100 ppm 1 ppm 10 ppm 15 ppm
RZ-81991-17 SO
2
0 to 100 ppm 1 ppm 2 ppm 5 ppm
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
9
Air/Gas Analysis
AI
Single-Gas / Multigas Detectors
Specifications
Gasman Single-Gas Monitors
Datalog and download up to
3000 hours with time and date stamp
l
Rechargeable lithium-ion battery
for 12 hours of operation
l
Rugged housing is IP 65/67 rated
for dust and water resistance
Small size and light weight ensure the monitors
are comfortable to wear all day long. Visible
flashing LED, audible 85 dB, and vibrating
alarms quickly alert the wearer to potential
gas hazards. Data is recorded by the monitor
and can be downloaded to a PC or printer using
the adapter/PC interface (sold separately).
Whats included: calibration cap, pocket clip,
and rechargeable lithium-ion battery.
Approval: UL and cUL Class I Div. 1
Groups A, B, C, D (pending), ATEX, CE
Alarm: 85 dB (audible), visible,
vibrating
Sensor life: 2 years
Functions: STEL, TWA, peak hold,
zero, low-battery indicator
Display: backlit LCD
Power: rechargeable lithium-ion
Battery life: 12 hours
Dimensions: 2"W x 4"H x 1
1
4"D
Instrument wt: 4 oz (0.1 kg)
RZ-86550-50 Adapter/PC interface, 110 VAC .......................................
RZ-86550-51 Adapter/PC interface, 230 VAC European .....................
Catalog
number
Sensor Range Resolution
Alarm set points
Price
Low High
RZ-86550-00 O
2
0 to 25% 0.1% 19.5% 23.5%
RZ-86550-02 CO 0 to 500 ppm 1 ppm 30 ppm
RZ-86550-04 H
2
S 0 to 250 ppm 1 ppm 5 ppm 20 ppm
RZ-86550-06 LEL 0 to 100% 1% 20% LEL
RZ-86550-08 SO
2
0 to 10 ppm 0.1 ppm 2 ppm
RZ-86550-10 NO 0 to 100 ppm 1 ppm 25 ppm
RZ-86550-12 NO
2
0 to 10 ppm 0.1 ppm 1 ppm
RZ-86550-14 O
3
0 to 1 ppm 0.1 ppm 0.5 ppm
86550-00
X-am 2000 Multigas Monitors
Reliable measurements, long life, and easy operation at a low cost of ownership
l
Large display allows for readings at a glance
l
Quick response to combustible gases
l
Withstands electromagnetic interference
l
Long 5-year sensor life
These meters are compact and lightweightabout the size of a mobile phoneproviding
comfort for long periods of wear. Meter can be easily set up using its straightforward menu
and two-button control panel. Gas is sensed through the top or front of the instrument
ensuring reliable detection regardless of meter placement or orientation. Robust, IP67-
rated design features shock-proof sensors to protect against impact or vibration, and an
integrated rubber boot provides dust and water protection even after being immersed
in water. The multitone audible alarm, 180 visual alarm, and built-in vibrating alarm
ensure wearer does not miss warnings. Meter includes a datalogger to store readings and
download via infrared interface to a PC for later analysis.
Whats included: crocodile clip and two AA batteries.
Approval: UL and cUL classified intrinsically safe in Class I, Div. 1,
Groups A, B, C, D, E, F, G T4; CSA; ATEX; CE
Accessories
RZ-86515-23 Rechargeable battery kit includes charger module
and rechargeable battery pack ..............................................................
RZ-86515-24 Bump test station ............................................................
RZ-86515-25 GasVision

software allows you to chart and


graphically display exposure data .......................................................
Sensor Range Resolution
Alarm set points
Low High
Combustibles 0 to 100% LEL 1% LEL 10% 20%
O2 0 to 25% 0.1% 19.5% 23.5%
CO 0 to 2000 ppm 1 ppm 35 50
H2S 0 to 200 ppm 1 ppm 10 ppm 20 ppm
Alarm: 90 dB at 1 ft (audible/visible/
vibrating)
Functions: datalogging, STEL, TWA,
min/max, low-battery indicator
Sensor life: 5 years
Display: LCD
Output: IR
Power: two AA batteries (included)
Battery life: 12 hours
Dimensions: 1
7
8"W x 5
1
8"H x 1
1
4"D
Instrument wt: 7.8 oz (0.22 kg)
Catalog number Description Price
RZ-86515-20 Four-gas monitor; O2, LEL, CO, H2S
RZ-86515-21 Three-gas monitor; O2, LEL, H2S
RZ-86515-22 Three-gas monitor; O2, LEL, CO
Specifications
86515-20
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
10
Air/Gas Analysis
AI
Multigas Detectors
GasAlertMicroClip

Multigas Detector
Performance of a multigas monitor with the feel and simplicity of a single-gas monitor
l
Simple single-button operation
l
Simple automatic calibration procedure
Lightweight, compact monitor is designed with a rugged housing with concussion-proof
boot for your most demanding work environments. Continuous LCD shows simultaneous
gas concentrations for H
2
S, CO, O
2
, and combustibles. Features four alarm levels: instant
low and high alarm level for all gases, TWA and STEL for CO and H
2
S, and an over-limit
alarm. A 95 dB alarm tone, bright alarm bars, and internal vibrating alarm are ideal for
high-noise areas. Features a standard datalogger (16 hours) and event logger (10 events)
to record TWA, STEL, and maximum exposure to gas and displays on command.
Approval: CSA Class I, Div. 1, Groups A, B, C, D; CE; ATEX
Whats included: belt clip, calibration hose/cap, and lithium polymer battery.
Confined-space kit includes IR connectivity kit, aspirator pump, 10-ft sampling hose,
calibration hose, 34-L gas cylinder, regulator, and hard carrying case.
Alarm: 95 dB (audible/visible/vibrating)
Functions: auto calibration, STEL, TWA,
peak readings, auto backlight, user-selectable
field options
Display: backlit LCD
Output: none
Power: lithium poly (included)
Battery life: 14 hours
Dimensions: 2
1
2"W x 4
1
4"H x 1
1
2"D
Instrument wt: 5.6 oz (0.2 kg)
Sensor Range Resolution Accuracy
Alarm set points
Low High
Combustibles 0 to 100% LEL 1% LEL 1% LEL 10% LEL 20% LEL
O2 0 to 30% 0.1% 0.1% 19.5% 23.5%
CO 0 to 500 ppm 1 ppm 1 ppm 35 ppm 200 ppm
H2S 0 to 100 ppm 1 ppm 1 ppm 10 ppm 15 ppm
Specifications
Catalog number Description Price
RZ-86418-20 Compact multigas detector
RZ-86418-22 Compact multigas detector with confined space kit
86418-20
Specifications
GasAlertMax

Four-Gas Detector
Simultaneously view four gas
concentration levels on
easy-to-read LCD
l
Plug-in Versapak

battery is
easy to replace and provides
14 hours of operation
l
Wide-angled alarm bar is
visible from all angles
Detector features internal sampling
pump for remote sampling and
easy one-button control. Order
the confined space kit to ensure
safe entry into a confined space.
Whats included: plug-in replaceable
sensors, two NiMH rechargeable
batteries, two-port charger, 10-ft
sampling hose, and holster with
belt loop. Confined space kit also
includes 34L calibration gas cylinder,
calibration hose, regulator,
and hard carrying case.
Approval:
CSA intrinsically safe
for Class I, Division 1,
Grade A, B, C, and D,
Class I, Zone 0,
Grade IIC;
CENELEC EEx ia IIC.
Alarm: 95 dB (audible/visible)
Functions: auto calibration,
maximum readings, TWA
(Time Weighted Average),
and auto backlight
Display: backlit LCD
Output: none
Power: two NiMH batteries
with 110 VAC charger
Battery life: 12 hours
Dimensions: 3"W x 6"H x 1
1
2"D
Instrument wt: 1 lb (0.5 kg)
Kit 81990-22

Oxygen cell has one-year warranty.

Sensor Range Resolution Accuracy


Alarm set points
Low High
Combustibles 0 to 100% 1% 1% 10% 20%
O
2
0 to 30% 0.1% 0.1% 19.5% 23.5%
CO 0 to 500 ppm 1 ppm 1 ppm 35 ppm 200 ppm
H
2
S 0 to 100 pm 1 ppm 1 ppm 10 ppm 15 ppm
RZ-81990-62 Four-in-one calibration gas cylinder, 58 L .....................
RZ-81990-80 Remote vibrator alarm provides additional
protection in high-noise environments ...............................................
RZ-81990-74 Battery charger; 230 VAC, European plug .....................
RZ-81990-82 Replacement battery, NiMH ...........................................
Catalog number Description Price
RZ-81990-20 Four-gas detector
RZ-81990-22 Four-gas detector with confined-space kit
81990-20
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
11
Air/Gas Analysis
AI
Multigas Detectors
GasAlertMicro5

Compact Multigas Monitors


Portable gas detectors simultaneuosly monitor and display up to five gases including
O
2
, combustibles (LEL), and three additional toxic gases
l
Integral, concussion-proof
boot and water-resistant
design handles rugged
environments
l
Audible, visible, and vibrating
alarm for high-noise areas
l
Auto back light in low-light
conditions
Water resistant with concussion-
proof enclosure, these monitors
feature superior design and
functionality at a competitive
price. Automatically cycles
through calibration when turned
on. Large, high-contrast LCD
shows continuous, real-time gas
concentrations. TWA, STEL, and
maximum exposure recorded
and displayed on command.
Additional user-selectable field
options include confidence beep,
pass-code protection, latching
alarm, safe display function,
stealth mode, span level, and selectable
ppm resolution for SO2 and CL2.
Whats included: belt clip, calibration hose/cap, and two AA
batteries. Confined-space kits also include an aspirator pump,
10-ft sampling hose, calibration hose, 34-L gas cylinder, regulator,
and hard carrying case.
Approval: CE; CSA Intrinsically safe for Class I, Div. 1, Groups A,
B, C, D; CENELEC EEx ia d IIC
Specifications
Alarm: 95 dB (audible/visible/
vibrating)
Functions: auto calibration, STEL,
TWA, peak readings, auto
backlight, user selectable field
options
Display: backlit LCD
Output: none
Power: two AA batteries (included)
Battery life: 16 hours
Dimensions: 2
1
2"W x 4"H x 1
1
4"D
Instrument wt: 7.5 oz (0.2 kg)
Sensor Range Resolution Accuracy
Alarm set points
Low High
Combustables 0 to 100% LEL 1% LEL 1% LEL 10% LEL 20% LEL
O2 0 to 30% 0.1% 0.1% 19.5% 23.5%
CO 0 to 999 ppm 1 ppm 1 ppm 35 ppm 200 ppm
H2S 0 to 100 ppm 1 ppm 1 ppm 10 ppm 15 ppm
SO2 0 to 100 ppm 0.1 ppm 0.1 ppm 2 ppm 5 ppm
CL2 0 to 50 ppm 0.1 ppm 0.1 ppm 0.5 ppm 1 ppm
Description
Monitor only With confined-space kit
Catalog number Price Catalog number Price
O2, CO, H2, SO2, LEL RZ-86418-02 RZ-86418-12
O2, CO, H2, CL2, LEL RZ-86418-04 RZ-86418-14
RZ-09376-01 Replacement batteries, AA. Pack of 4 ..................... /pk
GasAlertMicro

Compact Multigas Monitor


Palm-sized unit displays H2S, CO, O2, and combustibles (LEL)
simultaneously
l
Integral, concussion-proof boot for
rugged environments
l
Audible, visible, and vibrating alarm
for high-noise areas
l
Auto back light in low-light
conditions
Rugged monitor features superior
design and functionality at a
competitive price. Automatically
cycles through calibration when
turned on. Large, high-contrast LCD
shows continuous, real-time gas
concentrations. TWA, STEL, and
maximum exposure recorded and
displayed on command. Additional
user-selectable field options include
confidence beep, pass-code protection,
latching alarm, calibration due date,
safe display function, stealth mode,
and span levels.
Whats included: belt clip, calibration
hose/cap, and two AA batteries. Confined-space kit also includes
an aspirator pump, 10-ft sampling hose, calibration hose, 34-L gas
cylinder, regulator, and hard carrying case.
Approval: CE; CSA Intrinsically safe for Class I,Div. 1, Groups A, B,
C, D; CENELEC EEx ia d IIC
Specifications
Alarm: 95 dB (audible/visible/
vibrating)
Functions: auto calibration, STEL,
TWA, peak readings, auto backlight,
user selectable field options
Display: backlit LCD
Output: none
Power: two AA batteries (included)
Battery life: 16 hours
Dimensions: 2
1
2"W x 4"H x 1
1
4"D
Instrument wt: 7.5 oz (0.2 kg)
86418-00
Compact and lightweight
fits easily in your hand.
Catalog number Description Price
RZ-86418-00 Compact multigas monitor
RZ-86418-10 Compact confined-space kit
Sensor Range Resolution Accuracy
Alarm set points
Low High
Combustibles 0 to 100% LEL 1% LEL 1% LEL 10% LEL 20% LEL
O2 0 to 25% O2 0.1% O2 0.1% O2 19.5% O2 23.5% O2
CO 0 to 500 ppm 1 ppm 1 ppm 35 ppm 200 ppm
H2S 0 to 100 ppm 1 ppm 1 ppm 10 ppm 15 ppm
Call our Application Specialists for
help selecting the best gas monitor
for your application.
847-549-7600
RZ-09376-01 Replacement batteries, AA. Pack of 4 ..................... /pk
86418-02
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
12
Air/Gas Analysis
AI
Multigas Detectors
X-am 3000 Four-Gas Monitor
Built-in remote sampling pump is ideal for confined-space
pre-entry sampling
l
Three distinctive alarms signal the presence of hazards
l
Different alarm tones distinguish between pre and main alarm
l
Menus can be password protected to prevent tampering
Small size and light weight make this monitor ideal for confined-space entry
or all-day wear. Large, easy-to-read display quickly indicates gases measured
and their concentrations. Monitor features two high-intensity alarm lights, a
loud audible alarm, and a vibrating alarm to alert you of hazards even in high-noise
areas. Three easy-to-use buttons allow you to power unit, acknowledge alarm, and access
features. Rugged, IP65-rated, chemical-resistant polymer housing withstands bumps and
drops associated with harsh industrial environments and confined-space entries.
Approval: UL and cUL classified intrinsically safe in Class I, Div. 1,
Groups A, B, C, D, E, F, G T4; CSA; ATEX; CE; MSHA
Accessories
RZ-86515-32 Bump test station ............................................................
RZ-86515-33 Battery charger for rechargeable
NiMH battery ..........................................................................................
86515-30
Sensor Range Resolution
Alarm set points
Low High
Combustibles 0 to 100% LEL 1% LEL 10% 20%
O2 0 to 25% 0.1% 19.5% 23.5%
CO 0 to 2000 ppm 1 ppm 35 50
H2S 0 to 200 ppm 1 ppm 10 ppm 20 ppm
Alarm: 90 dB at 1 ft (audible/visible/
vibrating)
Functions: STEL, TWA, max readings
Sensor life: 2 years
Display: LCD
Output: none
Power: rechargable NiMH or two
AA batteries
Battery life: 24 hours (diffusion
mode), 12 hours (pump mode)
Dimensions: 5
1
2"W x 3
1
2"H x 2
1
4"D
Instrument wt: 19.4 oz (0.55 kg)
Specifications
Catalog number Description Price
RZ-86515-30 Four-gas monitor with sampling pump
RZ-86515-31
Four-gas monitor with confined-space kit and
sampling pump

Whats included: belt clip, calibration
adapter, pump adapter, filter, 10 ft
of Tygon

tubing, and NiMH battery.


Confined-space kit includes battery charger,
calibration gas, regulator, rubber boot, and
hard carry case.
Micro MAX Pro Multigas Detectors
Features unique voice assist warnings in four languages for additional safety
l
Voice Assist speaker
l
Loud 90-dB horn
l
Operates using internal sampling pump or in diffusion mode
l
Non-intrusive battery compartment
These multiple gas detectors are designed to provide the ultimate in personal safety.
Functions are accompanied by a verbal voice message. Voice warns of everything from
simple on/off function to hazard warnings and alarmsmaking it an excellent choice for
low-light applications. The voice message can be changed to speak English, Spanish,
French, or German. When unit goes into alarm, the voice alert is accompanied by 90-dB
audible and bright flashing visual alarms. An internal sample draw pump can be used to
perform pre-entry testing. The instrument is housed in a rugged case that provides superior
RFI/EMI shielding, as well as dust, water, and impact resistance. Designed, tested, and
manufactured under strict ISO 9001 standards.
Approval: UL classified for use in Class I, II, III Division I, Groups A, B, C, D, E, F, G
Whats included: rechargeable NiMH battery.
Sensor Range Resolution
Alarm set points
Low High
Combustibles 0 to 100% LEL 1% LEL 10% 20%
O2 0 to 30 % 0.10% 19.50% 23.50%
CO 0 to 1000 ppm 1 ppm 35 ppm 100 ppm
H2S 0 to 200ppm 1 ppm 10 ppm 15 ppm
SO2 0 to 100 ppm 1 ppm 2 ppm 5 ppm
Specifications
Alarm: 90 db, voice
Functions: TWA, STEL, peak
Display: backlit LCD
Output: RS-232
Power: rechargeable NiMH battery (included) or
four AAA alkaline batteries (not included)
Battery life: 13 hrs
Dimensions: 4
3
4"W x 3"H x 2"D
Instrument wt: 17.6 oz
Catalog number Description Price
RZ-10107-90
Two-gas detector;
O2, H2S

RZ-10107-91
Three-gas detector;
O2, LEL, CO

RZ-10107-92
Four-gas detector;
O2, LEL, CO, H2S

RZ-10107-93
Five-gas detector; O2,
LEL, CO, H2S, SO2

10107-92
RZ-09376-00 Batteries,
AAA. .............................................. /pack of 4
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
13
Air/Gas Analysis
AI
Four-Gas Monitor
Lithium-ion batteries provide up to 18 hours of continuous operation
l
Records up to 20,000 points for thorough record keeping
l
Concussion-proof boot for added durability
Reliable and rugged monitor includes a robust internal pump for remote
confined space monitoring.
Datalogging Monitor includes four sensors, internal pump, rechargeable lithium-ion
batteries, 120 VAC/DC adapter, alkaline battery adapter, calibration adapter, inlet probe,
water trap filters, carbon filters, reference guide, case, ProRAE software suite for
Windows

95/98/NT, computer interface cable, and instruction manual.


Datalogging Monitor with Confined Space Entry Kit also includes a four-gas mixture in a
34-L cylinder, calibration regulator with 15-ft Tygon

tubing, tool kit, and hard carrying case.


Approval: UL and cUL classified intrinsically safe in Class I, Div. 1, Groups A, B, C, and D;
EEx ia IIC T4
86263-27
Alarm
Visual: flashing red LED
Audible: 90 dB buzzer
Functions: datalogging up to 20,000 points
Display: 2 line, 16 digit LCD with backlight
Output: serial
Power: 120 VAC/DC, rechargeable
lithium-ion batteries, or optional
four AA alkaline batteries
Battery life: 18 hours
Specifications
Sensor Range Resolution Response time
Combustibles 0 to 100% LEL 1% 15 seconds
O2 0 to 30% 0.1% 15 seconds
CO 0 to 500 ppm 1 ppm 20 seconds
H2S 0 to 100 ppm 1 ppm 30 seconds
Catalog number Description Price
RZ-86263-27 Datalogging monitor
RZ-86263-28 Datalogging monitor with confined-space kit
Accessories
RZ-09376-01 Batteries, AA.
Pack of 4 ................................................... /pk
Dimensions:
4
5
8"W x 1
7
8"H x 3"D
Instrument wt:
1 lb (0.5 kg)
MultiRAE Multigas Monitor with PID
Rugged, booted instrument detects volatile organic compounds up to 2000 ppm
l
Internal memory stores response factors for common LEL gases and VOCs
l
Audible alarm has varying tones to distinguish specific alarm conditions
Alarm: 90 dB
Functions: two-point calibration, min/max
readings, Time Weighted Average (TWA),
Short Term Exposure Levels (STEL),
date/ time/elapsed time/temperature,
adjustable audible/visual alarm
Display: 2 line, 16-digit LCD with backlight
Output: serial
(datalogging models only)
Power: rechargeable adapter
or four AA batteries
Battery life: 10 hours
Dimensions: 4
5
8"W x 3"H x 2"D
Instrument wt: 16 oz (0.5 kg)
Most confined-space monitors provide less than total
protection because they miss many toxic vapors and
gases at low levels. The MultiRAE sampling monitor
features a Photo Ionization Detector (PID) that gives
you total protection from volatile organic compounds.
MultiRAE Monitor with PID and Datalogger has
an internal pump and comes with an operation video,
3"L inlet probe, water-trap filter, built-in rechargeable
battery, battery charger, alkaline battery adapter, calibration
adapter, carbon filters, rubber boot, belt clip, and a computer
interface cable as well as Windows

and DOS software for


storing up to 80 hours of readings and downloading up to
20,000 data points.
MultiRAE Confined-Space Kit includes a MultiRAE monitor
with PID and datalogger (86263-14), four-gas and isobutylene
calibration kit, 10 water trap filters, 15-ft Tygon

tubing, op video,
tool kit, and hard transport case.
Approval: UL and cUL classified intrinsically safe in Class I, Div. 1
Groups A, B, C, and D; EEx ia IIC T4.
RZ-86263-50 Four-gas calibration kit ...................................................
RZ-86263-52 PID calibration kit ............................................................
RZ-86262-50 Lamp cleaning kit ............................................................
Catalog number Description Price
RZ-86263-14 MultiRAE monitor with PID and datalogger
RZ-86263-21 MultiRAE monitor with PID and confined-space kit
86263-14 with
protective boot
Specifications
Sensor Range Resolution
Alarm set points
Low High
Combustibles 0 to 100% LEL 1% LEL 10 LEL 20% LEL
O
2
0 to 30% 0.1% 19.5% 23.5%
CO 0 to 500 ppm 1 ppm 35 ppm 200 ppm
H
2
S 0 to 100 ppm 1 ppm 10 ppm 20 ppm
PID (VOCs)
0 to 200 ppm,
200 to 2000 ppm
0.1 ppm,
1 ppm
50 ppm 100 ppm
Gas Detection, Multigas / PID
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
14
Air/Gas Analysis
AI
Specifications for ToxiRAE Plus Personal PID
Alarm: 90 dB, auto shut off pump at
low-flow condition
Functions: instantaneous, average,
Short Term Exposure Limit (STEL),
and peak value; battery voltage;
elapsed time
Display: alarm, darkness, or manually
activated backlighted LCD
Detector lamp: 10.6 eV
Output: serial (datalogging model only)
Power: rechargeable NiMH battery
or four AA alkaline batteries
(not included)
Battery life: 10 hours
Dimensions: 8
1
4"L x 3"W x 2"H
Instrument wt: 19 oz (0.6 kg)
Alarm: 90 dB buzzer and flashing red
LED patterns indicate exceeded
preset limits: high, low, and Short
Term Exposure Limit (STEL) or
Time Weight Average (TWA)
Functions: STEL and TWA values of
toxic and VOC gases; programmable
alarm; battery voltage; elapsed time
Display: 8-digit LED
Detector lamp: 10.6 eV
Output: serial (datalogging model only)
Power: rechargeable NiCd battery or
two AA alkaline batteries
(not included)
Battery life: 10 hours
Dimensions: 6"L x 1
3
4"W x 1"H
Instrument wt: 6.4 oz (0.2 kg)
Accessories for All Detectors
RZ-86263-52 PID calibration kit includes 100-ppm
isobutylene, 34-liter cylinder, and regulator with adapter .................
RZ-86262-50 Lamp cleaning kit ............................................................
RZ-86264-50 Automotive power adapter ............................................
RZ-09376-01 Batteries, AA. Pack of 4 ............................................ /pk
ToxiRAE Plus Personal PID
Both models include rechargeable
NiCd battery, single-unit charging
station, 110 VAC battery charger,
alkaline battery adapter for two
AA batteries, and calibration
adapter with tubing.
Standard Detector features
two operation modes
operate in display mode to
view instantaneous, STEL, TWA,
and peak readings; use password-
protected program mode to
ensure secure alarm and calibration settings.
Datalogging Detector has the same features as the standard
model, plus 4000-reading datalogging with time/date stamp and
programmable, manual, periodic, or scheduled start/stop. Includes
software for Windows

98, NT, or XP and computer interface cable.


Approval: UL and cUL classified intrinsically safe in Class I,
Division 1, Groups A, B, C, D; EEx ia IIC T4; CE.
86261-00
MiniRAE 2000 Survey PID
Powerful, versatile, and user-friendly
with a standard operating range of
0 to 10,000 ppm, the MiniRAE 2000 is
ideal for many industrial applications.
Strong internal pump draws samples
up to 100 feet horizontally or vertically.
All monitors include 10.6 eV lamp, 5" inlet
probe, water trap filter, rubber boot with
belt clip, alkaline battery adapter, tool kit,
built-in rechargeable NiMH battery for
10 hours of continuous operation,
120 VAC battery charger, wrist strap,
operation video, and shipping case.
Standard Detector offers two modes.
Use survey mode to display instantaneous
readings, activate high/low alarms, and store
up to 15,000 readings with user ID, site ID,
serial number, and time/date stamp. Choose
hygiene mode to display or record TWA,
STEL, and peak levels. Activate separate
alarms for each parameter.
Datalogging Detectors have the same features
as the standard MiniRAE 2000. Download data
and upload instrument setup from a PC through
RS-232 link to a serial port. Include cable and
software for Windows 98, NT, or XP.
Datalogging Detector with Accessories and
Calibration Kit includes lamp cleaning
kit, five porous metal filters, O-rings,
organic vapor zeroing kit, gas outlet
port and tubing, 100 ppm isobutylene
calibration gas, 34-liter cylinder,
regulator, flow controller, and case.
Approval: UL and cUL classified intrinsically
safe in Class I, Division 1, Groups A, B, C, D;
EEx ia IIC T4; CE.
86262-15
Specifications for MiniRAE 2000 Survey PID
l
Electrodeless 10.6 eV lamp ionizes chemicals for more sensitive
concentration readings
l
Immediate VOC readingseliminates costly and time-consuming
lab analysis
PID technology provides real-time detection of Volatile Organic
Compounds (VOC), hazardous gases, or vapors in parts per
milliontake immediate safety action in response to excessive
exposure instead of waiting days or weeks for lab results.
Choose the pocket-size ToxiRAE monitor for personal monitoring;
select the handheld MiniRAE 2000 for environmental, industrial
hygiene, health, safety, and plant applications.
Catalog number Description Price
RZ-86262-15 Standard MiniRAE 2000 survey PID
RZ-86262-20 Datalogging MiniRAE 2000 survey PID
RZ-86262-25
Datalogging MiniRAE 2000 survey PIDr with
accessories and calibration kit

Catalog number Description Price
RZ-86261-00 Standard ToxiRAE Plus personal PID
RZ-86261-10 Datalogging ToxiRAE Plus personal PID
Range Resolution Accuracy
0 to 99.9 ppm 0.1 ppm 10% of reading < 2000 ppm
100 to 10,000 ppm 1 ppm 20% of reading > 2000 ppm
Photo Ionization Detectors (PID)
Photo ionization detector (PID) ensures highly sensitive
broad-band toxic gas detection for maximum worker protection
Range Resolution Response time Accuracy
0 to 99.9 ppm 0.1 ppm 10 seconds
10% of reading
100 to 2,000 ppm 1 ppm 10 seconds
Gas Detection, PID
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
15
Air/Gas Analysis
AI
RZ-81973-50 Calibration kit ...........................
RZ-81973-60 RS-232 interface.
Includes Windows

98 software .....................
Accessories
Catalog number Range Resolution Accuracy Price
CO
2
monitor
RZ-81973-20 0 to 50,000 ppm (0 to 5%) 100 ppm (0.01%) 5% reading or 50 ppm


CO
2
analyzer
RZ-81973-00 0 to 10,000 ppm 10 ppm 5% reading or 100 ppm


CO
2
incubator monitor
RZ-81973-10 0 to 50% 0.01% to 3%, 0.1% above 3% 5% reading or 300 ppm

Whichever is greater
Specifications
Alarm: audible/visible
Display: backlit LCD
Dimensions: 2
5
8"W x 5
1
2"H x
13
16"D
Instrument wt: 1.7 lb (0.7 kg)
Power: one NiCd rechargeable battery
with 110/240 VAC charger (included)
Battery life: 8 hours
81973-20
81973-10
Carbon Dioxide Meters
Rapid detection of changing CO
2
levels
l
Maintenance-free pressure and temperature compensated sensor
l
Ideal for IAQ surveys, food packaging, ventilation verification, and incubator checks
CO
2
Monitor is a compact and lightweight detection device that immediately responds
to excessive levels of CO
2
ideal for personal monitoring. Meter features a maintenance-
free infrared sensor and audible/visible alarms that respond intermittently to CO
2

concentrations above 5000 ppm and continuously to concentrations above 10,000 ppm.
CO
2
Analyzer features a dual wavelength pressure and temperature compensated
sensor for fast, accurate CO
2
measurement. Built-in datalogger stores up to 850
readingsideal for indoor air quality surveys and ventilation checks. Audible/visual
alarm responds intermittently to CO
2
concentrations above 5000 ppm and continuously
to concentrations above 10,000 ppm.
CO
2
Incubator Monitor provides fast, accurate CO
2
level monitoring. Features a powerful
internal pump for extracting samples; two sampling modes, sample draw and diffusion;
integral fan; and maintenance-free dual wavelength pressure and temperature compensated
sensors. Keep records of your CO
2
levels with the built-in datalogging feature. Choose to
log your readings continuously or with the manual snapshot mode. Nonvolatile memory
holds approximately 100 snapshot readings and 800 sets of continuous datalogged readings.
Download stored readings to your PC for storage or analysis via the infrared data link.
Alarm features a variable pitched tone to indicate CO
2
levels.
Whats included: one 8-hour continuous-use NiCd battery with 110/240 VAC charger.
Model 81973-10 also includes a sampling probe and hose assembly.
Alarm: adjustable audible/visible
Display: backlit LCD with graphic display
Operating temperature: 40 to 140F (40 to 60C)
System requirements: Windows

95 or above
Output: RS-232, 0 to 1 VDC
Data storage: 2700 points
Power: rechargeable NiMH battery
with 115 VAC adapter
Dimensions: 3
1
8"W x 7
7
8"H x 1
5
8"D
Instrument wt: 2 lb (0.9 kg)
Specifications
86437-00
Catalog number Range Resolution Accuracy Price
RZ-86437-00 0 to 2000 ppm 1 ppm 20 ppm CO2 + 2% of reading
RZ-86437-02 0 to 20% 0.01% 0.02% CO2 + 2% of reading
l
Intuitive, menu-driven display with shortcut buttons for easy operation
l
Quickly store and datalog up to 2700 readings
Low-maintenance, high-accuracy CO
2
sensor only requires calibration every two years.
Backlit display shows reading both numerically and graphicallystore data in memory
or download to PC via RS-232. Includes a second probe portorder optional temperature/
humidity probe to expand measurement capabilities (sold separately below).
Ideal for applications including: laboratory fume hood checks, industrial hygiene studies,
spot measurement of food and beverage storage/lines, and HVAC monitoring.
Whats included: CO
2
probe, rechargeable battery with 115 VAC adapter, software,
RS-232 cable, and manual.
Approval: Meter: IP54; Probe: IP65 (NEMA 4), CE
Compliance: EN 61326-1:1997 for electromagnetic compatibility
RZ-37301-90 Optional temperature/humidity probe ...................................................................
Datalogging Carbon Dioxide Meters
Silicone-based infrared sensor ensures superior stability over time and temperature
Air Quality, Carbon Dioxide
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
16
Air/Gas Analysis
AI
Air Quality Meters
Simultaneously monitor temperature, humidity, carbon dioxide, and carbon monoxide
l
Easy, menu-driven operationno training required
l
User-selectable alarm settings to alert operator when readings reach the programmed level
Versatile monitors combine the basic functionality of a temperature/humidity meter with
expanded gas monitoring capabilities for your most complete portable IAQ tool. These
compact, multiparameter instruments are ergonomically designed for handheld use or use
the flip-out stand for stand-alone monitoring. Audible, visible, and internal vibrating alarms
indicate when readings reach a particular levelyou can step away from the instrument
during testing.
Whats included: RTD probe, rechargeable lithium ion battery with 115 VAC charger/adapter,
manual, and soft carrying case. Datalogging model also includes software.
Alarm: 85 dB/red LED (audible/visible) and
internal vibrating alarm
Display: backlit, multiparameter LCD
Operating temperature:
4 to 122F (20 to 50C)
Power: rechargeable 16-hour lithium ion battery with
115 VAC charger/adapter (included)
Battery life: 16 hours
Dimensions: 3
1
2"W x 6
11
16"H x 1
1
2"D
Instrument wt: 15 oz (0.4 kg)
Specifications
Catalog number Description Price
RZ-86439-00 Air quality meter
RZ-86439-10 Air quality meter with datalogging
Parameter (sensor) Range Resolution Accuracy
CO
2
(infrared) 0 to 250 ppm; 0 to 500 ppm (selectable) 1 ppm 3% of reading
CO (electrochemical) 0 to 500 ppm; 0 to 10,000 ppm (selectable) 1 ppm 3% of reading
Temperature (RTD) 32 to 104F (O to 40C) 0.1F (0.1C) 0.2F (0.1C)
RH (capacitive polymer) 0 to 95% 1% 2% of reading
86439-01
Features one-button
calibration
RZ-93831-70 Optional RTD probe for
secondary temperature ..........................................................................
RZ-86384-50 Calibration kit for 86384-01 .............................................
RZ-86384-51 Calibration kit for 86384-11 .............................................
RZ-09376-01 Replacement batteries, AA. Pack of 4 ..................... /pk
IAQ-Calc

Meters
Easy-to-use keypad scrolls through all readings at the touch of a button
l
Low-drift NDIR CO
2
sensor gives stable, accurate readings
l
Check building IAQ conditions to optimize productivity
l
Ideal for testing HVAC system performance
The IAQ-Calc CO
2
Meter provides cost-
effective CO
2
measurements. The sampling
function records multiple point
measurements.
The IAQ-Calc Advanced IAQ Meter
calculates % outside air from either
CO2 or temperature readings and
directly calculates dew point,
wet bulb temperature, absolute
humidity, and humidity ratio. The
dual-line display simultaneously
displays multiple parameters.
Datalogger logs up to 26,900
samples with time/date stamp.
The included LogDat2 software
permits easy transfer of data to
your computer and the LogDat2
Companion for Excel

automatically
graphs all your data.
Whats included: NIST-traceable
certificate, carrying case, and
batteries. Model 86384-15 also
includes probe and AC adapter.
Catalog number Description Price
RZ-86384-05 IAQ-Calc CO2 meter (measures CO2 only)
RZ-86384-15 IAQ-Calc advanced IAQ meter
Specifications
Display: multiparameter LCD
Operating temperature:
41 to 158F (5 to 70C)
System requirements: Windows

3.1
or Windows 95 or higher
Power: four AA batteries (included)
or 115 VAC adapter
(included with 86384-11)
Dimensions: 4"W x 6
11
16"H x 1
1
2"D
Instrument wt
Model 86384-01: 12 oz (0.4 kg)
Model 86384-11: 17 oz (0.5 kg)

Applies to the advanced IAQ meter only.


Parameter Range Resolution Accuracy
CO
2
0 to 5000 ppm 1 ppm
3% of reading or
50 ppm, whichever is greater
CO

0 to 500 ppm 0.1 ppm


3% of reading or
3 ppm, whichever is greater
RH

5 to 95% 0.1% 2%
Temperature

32 to 140F
(0 to 60C)
0.1F
(0.1C)
1.0F
(0.6C)
% outside air

0 to 100% 0.1%
86384-11
GO
to page(s)

731748
For our complete line of humidity products,
go to pages 731748
Air Quality, IAQ Meters
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
17
Air/Gas Analysis
AI
RZ-86316-61 Ozone calibrator (0.1 ppm) ..............................................................................................
86316-30
Pocket Ozone Detector
Accurate, easy-to-read digital display
l
Versatile meter can be used for fixed or portable monitoring
l
Ideal for leak checks in generators, valves and piping
The heated metal oxide semiconductor has a range of 0.02 to 10 ppm; digital readout is in 0.01
ppm increments. Use as a permanent monitor indoors when the concentration average is below
0.1 ppm; use outdoors or at concentrations up to 10 ppm for short periods of time. Includes
rechargeable batteries, charger, and carrying case.
Order optional calibrator to verify that your ozone monitor is conforming to the original calibration.
Calibrator recalibrates detector at 0.1 ppm. It measures 2
1
4"W x 3
3
4"H x 1"D and includes a 9 V battery.
Display: LCD Power: rechargeable batteries with a charger (included) Dimensions: 2"W x 4"H x 1"D
Specifications
RZ-86316-61 Ozone calibrator (0.1 ppm) ...............................................................................................
RZ-09376-04 Replacement battery, 9 V. Pack of four ..................................................................... /pk
Continuous Ozone Monitors
Fixed or portable systems alert workers to hazardous ozone levels
l
Easy-to-read, multicolor graphical display
l
HMOS sensor for superior sensitivity
LED bar graph changes color as ozone levels increase: green indicates a safe level, yellow is caution
level, and red is the danger level. Both models feature a heated metal oxide semiconductor (HMOS)
sensor for excellent sensitivity and quick response time. Order optional calibrator to verify that your
ozone monitors are conforming to their original calibration.
Fixed Ozone Monitor with Alarm has an audio alarm that is triggered at 0.1 ppm (danger level).
Features include a connection for external equipment control. Portable Ozone Monitor can be
permanently installed for on-site use or carried with you to detect leaks throughout your plant.
Display: LED color bar graph
Output: 0 to 3 VDC
Dimensions: 2
3
8"W x 3
1
4"H x 1
3
8"D
Power
Model 86316-10: AC adapter (included)
Model 86316-20: rechargeable eight hour NiMH battery
and an AC adapter/recharger (included)
86316-10
Display 86316-20
Specifications
86487-00
Display: green/red indicator light
Output: 250 VAC, 5 A
Power: 12 to 24 VDC power supply
Dimensions: 3
1
2"W x 3"H x 1
3
4"D
Specifications
RZ-86316-61 Ozone calibrator (0.1 ppm) ..............................................................................................
Ozone Relay Switch
Monitors ozone levels to control ozone generators and alarm relays
l
User adjustable setpointselect appropriate ozone level to meet your needs
l
Ideal for use as leakage alarm in water treatment plants, food storage and processing,
semiconductor manufacturing, and sterilization areas.
Switch is housed in rugged, ABS plastic case that is easily mounted to any wall or inside
air ducts. HMOS sensor detects the presence of ozone in 0.03 to 1 ppm range. Simply
configure alarm set point to desired levelswitch has red visible indicator and activates
relay when level is exceeded. Switch operates on 12 to 24 VDC power supply and features
SPDT nonlatching relay output.
LED provides
visual indication
when ozone level
is exceeded.
Catalog number Description Range Price
RZ-86316-10 Fixed ozone monitor with alarm
0.02 to 0.14 ppm (0.2 to 0.30 or more ppm
with an external data readout)

RZ-86316-20 Portable ozone monitor 0.02 to 0.14 ppm
Catalog number Description Range Price
RZ-86316-30 Ozone detector 0.02 to 10 ppm
Catalog number Description Range Price
RZ-86487-00 Ozone relay switch 0.03 to 1 ppm
Ozone Detectors
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
18
Air/Gas Analysis
AI
86392-00
AirAware Fixed-Gas Monitors
Easy to usesingle button calibration and fresh air zero functions!
l
Bright LCD shows instantaneous concentrations of gas.
l
Broad gas ranges with quality sensors
Low/high alarm settings alert workers of potential gas hazards. Basic monitor plugs easily
into any AC outletno installation required. Models with 4 to 20 mA output have dual
relays to trigger remote alarms/ sirens, turn on fans, or shut down a process.
Approval: CSA
Specifications
Power
Monitors: 120 VAC
Monitors with output: 12 to 24 V AC/DC
Dimensions: 3
1
8"W x 5
1
4"H x 2
5
8"D
Alarm: 85 dB (audible/visual)
Functions: continuous monitoring, one-button calibration,
fresh-air zero
Output: 4 to 20 mA and 5 A SPDT relays (86392-10, -12, -14 only)
Sensor Range Resolution
Alarm set points Monitor Monitor with 4 to 20 mA output
Low High Catalog number Price Catalog number Price
O2 0 to 30% 0.1% 19.5% 23.5% RZ-86392-00 RZ-86392-10
CO 0 to 500 ppm 1 ppm 3 ppm 70 ppm RZ-86392-02 RZ-86392-12
Cl2 0 to 100 ppm 0.1 ppm 0.5 ppm 1 ppm RZ-86392-14
Dimensions:
2
3
8"W x 3
1
2"H x 1
3
8"D
86316-00
Datalogging VOC Detector with Alarm
Prevent health hazards by detecting leaks and poor air quality early
l
Detects acetone, methylene chloride, naphtha, trichloroethylene, and more
l
Ideal for laboratories, paint/print shops, and woodworking facilities
Use this economical VOC detector wherever solvents are present. The sensor is highly
sensitive to VOCs and solvent vapors. The LED bar graph displays the hazard level of gas
or vaporgreen indicates normal, yellow for caution, and red for danger. An audible alarm
also alerts you to dangerous levels. Responds in one minute. A rechargeable NiCd battery
lets you take the detector anywheretrace leaks to their source. Features include a 0 to
2 VDC output for datalogging and a connection for external equipment control.
Display: LED color bar graph
Output: 0 to 2 VDC
Specifications
Power: rechargeable NiCd battery
with an AC adapter/charger (included)
Catalog number Description Range

Price
RZ-86316-00 VOC detector with alarm 50 to 100 ppm

For most solvent based VOCs.


81949-00
Leak Hunter Plus

Gas Leak Detector


Microvolume thermal conductivity cells provide
the most sensitive leak detection possible
l
LCD with nine-segment bar graph displays exact leak rate
Measure any gas with a thermal conductivity different from
the surrounding air in cc/sec, cc/min, cu ft/min, or ppm.
To operate, simply select calibration data for one of twelve
gases and take your readings. Audible alarm changes
frequency according to leak rate.
Whats included: 8"L detachable probe, flexible probe
extension (increases probe length to 16"), probe clip for
one-handed operation, built-in stand with nonskid feet,
one 9 V NiCd rechargeable battery, AC adapter/charger,
and carrying case.
Detection limits
Specifications
Probe: 8" detachable
Functions: peak hold, autoranging
(for maximum sensitivity), low-
battery, and cell failure indications
Power: 9 V NiCd battery (included)
Battery life: 8 hrs
Instrument wt: 3.3 lb (1.5 kg)
Group Gas Sensitivity
1
H2 8.10 x 10
6
cc/sec
He 1.00 x 10
5
cc/sec
2
Neon 5.80 x 10
5
cc/sec
Xenon 5.81 x 10
5
cc/sec
3
R11 6.84 x 10
5
cc/sec
R12 7.90 x 10
5
cc/sec
R21 7.98 x 10
5
cc/sec
R22 9.46 x 10
5
cc/sec
4
CH4 1.06 x 10
4
cc/sec
Ar 1.37 x 10
4
cc/sec
CO2 1.53 x 10
4
cc/sec
H2O vapor 1.75 x 10
4
cc/sec
Catalog number Power
Probe
length
Dimensions Price
RZ-81949-00 115 VAC
8" 3"W x 6
3
4"H x 1"D

RZ-81949-05 220 VAC
Fixed-Gas Detectors
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
19
Air/Gas Analysis
AI
CheckPoint O
2
and O
2
/CO
2
Analyzers
Measure gas levels in modified atmosphere packages (MAP) in just 10 seconds
l
Internal memory function stores up to 10 tests
l
Battery powered for up to 2400 measurements
Compact, handheld CheckPoint analyzer packs excellent functionality in a
portable, easy-to-use instrument. Simply use probe assembly to penetrate
package to be sampled. Powerful, internal pump draws 15-mL sample and displays
gas concentration level in seconds on bright, 3-digit LED display. Memory
function allows you to store up to 10 readings to be recorded later. Auto-calibration
feature ensures quick calibration at the touch of a button. Analyzer will power off
automatically after one minute of inactivity to save battery life. Display hold option
enables you to lock the display for easy readability.
Analyzers are encased in a rugged, anodized aluminum housing with IP53 rating
for impact and splash resistance. Integrated needle holder prevents accidental
sticks when probe is not in use. Select from single O
2
or combined O
2
/CO
2
model
to suit your application.
Whats included: sampling probe assembly, ten septa, ten replacement needles and
filters, four AA batteries, and NIST-traceable calibration certificate.
Sensor type
O
2
: electrochemical
CO
2
: infrared (86490-02 only)
Specifications
Catalog number Description Range Resolution Accuracy Price
RZ-86490-00 CheckPoint O2 0 to 100% 02 0.1%
0.1% (0 to 5%),
2% (5 to 100%)

RZ-86490-02 CheckPoint O2 /CO2
0 to 100% O2
0 to 100% CO2
0.1%
O2: 0.1% (0 to 5%),
2% (5 to 100%);
CO2: 0.2% (0 to 10%),
2% (10% to 100%)

Catalog number Description Range Resolution Accuracy Power (VAC, Hz) Price
RZ-86490-20 CheckMate II O2 10 ppm to 100% 0.10% 1% of reading 115, 50/60
RZ-86490-21 CheckMate II O2/CO2
O2: 10 ppm to 100%
CO2: 0 to 100%
O2: 0.1%
CO2: 0.1%
O2: 1% of reading;
CO2: 2% FSD
115, 50/60
Sampling pump:
200 mBar max vacuum pump
Sampling assembly: probe with integral
needle holder and sampling hose
Power: four AA
batteries (included)
Dimensions:
3"W x 5
2
3"H x 2
1
2"D
Sensor type
O2: ceramic solid state
CO2: infrared
Specifications
Sampling pump: built-in, automatic
sample draw
Sampling assembly: probe with integral
needle holder and sampling hose
86490-02
Needle and
probe are
conveniently
stored inside
meter case
when not in use.
Icon-based, smart keys allow
hassle-free operation.
86490-21
CheckMate II O
2
and O
2
/CO
2
Analyzers
Configure up to five hundred customized product testing programs
l
Logging of more than 10,000 test results
l
Download data via built-in USB port
l
LAN monitor capability
l
Requires only a small sample volume use for both food and pharmaceutical
headspace measurements.
Benchtop CheckMate II analyzers are fast, reliable, and easy to use. Powerful
units require only 2-mL O2 or 5-mL CO2 sample volume. Gas sampling starts
automatically as syringe is introduced to the package for fail-safe operation.
Sensor features water trap system to maintain sensor integrity. Gas levels
display in 5 seconds on backlit LCD.
Use icon-based smart keys to customize sampling, alarms, and data recording
parameters for up to 500 different product types. Complete documentation of test
results with time/date stamp can be sorted and printed immediately, or stored
for download later to computer. Analyzers feature self-diagnostics to monitor
operation and prevent common user errors. Select from single O2 or combined
O2/CO2 model to suit your application.
Whats included: sampling probe assembly, ten septa, ten replacement needles,
five replacement sampling hoses, ten water trap filters, two rolls of replacement
printer paper, USB stick for download, and NIST-traceable calibration certificate.
Dimensions: 11
7
8"W x 7"H x 8
5
8"D
Headspace Analyzers, O
2
/ CO
2
Table-of-Contents Web Registration
U.S. Toll-free: 800-323-4340 Outside the U.S.: 847-549-7600 www.coleparmer.com
Canada 800-363-5900 India 91-22-6716-2222 UK 0500-345-300
20
Air/Gas Analysis
AI
Display
10360-70
Headspace O
2
/CO
2
Analyzers
Measure the amount of oxygen in food packaging to ensure
product quality and safety
l
Save time and money by preventing spoilage
Use these analyzers to measure residual oxygen in gas-flushed
CAP/MAP food packages. Analyzers resist nitrogen and carbon
dioxidecommonly used as background gases in packaging.
Calibrate the units by sampling room airnormal air reading is
20.9% oxygen. Durable sensor in the analyzer has excellent zero
and span stability after calibration.
Handheld Oxygen Analyzer
This handheld analyzer is compact and lightweight so you can
take it anywhere you need to measure residual oxygen levels in
packages. Use a sampling probe assembly with a needle to pierce
through the package. A built-in pump draws and delivers a sample
to the sensor. Analyzer can also be used for applications where
the oxygen level is very high (50 to 100%), without overloading
the sensor. Other features include auto shut-off after 45 minutes
of nonuse and low-battery indication.
Whats included: one sampling probe assembly, two needles,
one syringe filter, two septas, four rechargeable NiCd batteries,
and a charger with 115 VAC adapter.
Note: analyzer must always be used with rechargeable
NiCd batteries.
Specifications
Sensor type: electrochemical cell
Sampling pump: internal with
adjustable timer from 5 to 10 seconds
Sampling assembly: probe with
male luer connection for side-port
needle, coiled PTFE tubing
Power: four AA NiCd
rechargeable batteries
(included)
Battery life: 8 hours
Dimensions: 4"W x 8"H x 1
3
4"D
Handheld analyzer 10360-20
Accessories for Both Analyzers
RZ-10360-24 Replacement sampling probe assembly .......................
RZ-10360-26 Replacement needles, side-port hole.
Pack of three .................................................................................... /pk
RZ-10360-28 Replacement septa provide leak-tight seal
upon needle penetration. Pack of 200 ........................................... /pk
Benchtop O
2
/CO
2
Analyzer
Use this benchtop analyzer for continuous package testing in the
laboratory or at the packing line. Analyzer features a heavy-duty,
maintenance-free sensor that compensates for slight temperature
variations. Unlike other sensors, accuracy is not affected by flow
rate, heat, or hydrocarbon gases.
Model 10360-30 is used to sample food packs, insert the needle tip
of the probe into the food pack through a foam seal pad. Seal pad
provides a tight seal and prevents air from leaking into the package
through the puncture hole. Press the pump button to draw a
sample from the package. The built-in pump draws in the precise
amount of sample required for analysis, then turns off after a pre-
set sampling time.
Pharmaceutical oxygen headspace analyzer (model 10360-60) is
ideal for measuring headspace oxygen in vials.
Select model 10360-70 for oxygen and carbon dioxide testing.
10360-70 features a solid state infrared sensor for measuring CO2
as well as electrochemical cell for O2.
Whats included: sampling probe assembly, needle, syringe filter,
small pack of septa, NiCd battery, and a 115 VAC adapter.
Benchtop analyzer
10360-30
Sensor type: heavy-duty
electrochemical O2 cell;
Infrared CO2 sensor
(model 10360-70 only)
Sampling pump: miniature diaphragm
type with adjustable timer from 1 to
10 seconds
Sampling assembly: probe/needle
holder for luer needle with side hole;
disposable filter,
1
16" OD inert tubing.
Power: 115 VAC or rechargeable
NiCd battery (included)
Battery life: 8 hours
Dimensions: 10"W x 4"H x 9
3
4"D
Specifications
Catalog number Range Resolution Accuracy Price
RZ-10360-20 0.1 to 100% oxygen 0.1% 1%
Catalog number Range Resolution Accuracy Price
RZ-10360-30 0.1 to 100% O2 0.1% O2 0.1%
RZ-10360-60 0.1 to 100% O2 0.1% O2 0.1%
RZ-10360-70
0.1 to 100% O2,
0.1 to 100% CO2
0.1% O2,
0.1% CO2
0.1%
Headspace Analyzers, O
2
/ CO
2

S-ar putea să vă placă și