Four-wire

Villa Intercom System


Installer & User Manual

VILLA INTERCOM SYSTEM
Please read this user manual carefully
before using the products. Please keep
it for future reference.
VER:1.0
340302000860
Content
1. 1
2. 1
3. 3
4. 3
5. 4
One door station4
Two door stations5
Signal unlock6
Power unlock6
6
6. 6
7. Product Appearance7
8. 8
Component s
Door Station Installation
Indoor Phone Installation
Door Station Switch Installation
Syst em Di agr ams
Speci f i cat i ons
Operation
Indoor phone Jumper Setting
,Any question towards our product
distributors or, please contact Genway agents
Genway customer service center directly .
sale service consultation procedure-After
Describe product name.
Describe product model.
Describe the trouble.
mail address-and e. Leave your Tel No.
Statement
Please forgive us if we could not notify you timely
towards any alteration to our product model No .
or technical parameter .
s manual is not consistent with the actual'If the user
the, operations due to technology upgrading
explanation right is reserved to Genway company .
F5D10 F5D50
F3120
F5S70
F3010 F3190
F5S60
F3110
Indoor phone with built-in
power supply doesn't use
this.
F5S50
Door station switch
F5S50

60.5
45.5
1
2
8
94
9
2
8. Operation
1. When a visitor presses the call button of door station, the indoor
phone rings, and the screen shows the visitor's image.
2. If there is no answer, the system will automatically reset to
standby state after 60s.
[Note] If the system have two door stations, it will ring busy tone when
calling from the other door station as the line is busy.
Call

In ring, talk or monitor state, press button of indoor phone to
open the door, at the same time, the door phone and the indoor
phone will sound "di" to prompt that door is open.
Unlock

1. In standby state, press button of indoor phone to monitor the
conditions around the door station.
2. If there are two door stations, the monitor for different entrances
is available by turns.
Door station 1 End monitor Door station 2 End monitor
3. In monitor state, pick up the handset of indoor phone can talk to
the visitor.(If hands-free indoor phone: press button)
[
If someone calls from door station, it will end monitoring and
begin to call immediately.
Monitor
Note] It will automatically end the monitor after 60s;
Intercom between indoor phone
1.In standby state, press button in any of the indoor phones
st
(1 indoor phone), the other indoor phones will ring together.
2.Pick up the handset (if hands-free indoor phone: press button)
nd
of one indoor phone (2 indoor phone), the other indoor phones
will stop ringing
3.At this time pick up the handset (if hands-free indoor phone:
st
press button) of the 1 indoor phone, intercom is available
st nd
between the 1 and the 2 indoor phones.
[Note] 1.You can also pick up the handset of the indoor phone, then
press button to start the intercom.
2.There is no image during the intercom between indoor phone.
8 1
This device is used in "two
door stations" system.
Press button
1. Components
Option of door station
Accessories
Accessories
Option of indoor phone
Other fittings
Power supply Indoor phone accessories User manual
[Note] The power supply varies in different countries, please check with us before ordering.
2. Door Station Installation
Unit: mm
Door/Wall
Panel
Frame
Screw
Door/Wall
Panel
Frame
Screw
Unit: mm
Talk
1. Pick up the handset of indoor phone to talk with the visitor.
(If hands-free indoor phone: press button)
2. During talk, hang up the handset to end the talk.(If hands-free
indoor phone: press button)
[Note] It will automatically end the talk after 120s.
Press button Press button Press button
Mute setting
Adjust the [Ring Volume Adjustment] of indoor phone to the
lowest, the ring will turn off, and the indicator is on.
F3030
F3H40

D1
W1
H
1
D2
H
2
W2
(H1)(W1)(D1) (H2)(W2)(D2)
16610838 16412642 F5D10
20810838 20612642 F5D50

201
F5D10/F5D50
F5S70
1
3
5
58 48
6
0
Name plate
Plastic
1.Insert the screw driver in the
notch. Turn and push the
plastic upwards.
2.Change the name plate.
3.Put the plastic back to the
groove.
Change name plate
Built-in Installation
2 7
7. Product Appearance

During installation, put


the wire through the hole
of PC plate, then connect
it with door station terminal,
and glue the PC plate on
the door station rear panel
at last.
Iron door
Installation size
Wall
Installation size
Unit: mm
Change name plate
Name plate
Plastic
Door/Wall Panel
Frame
Plugs
Screw

1.Push the right edge


and move to right.
2.Take off
the plastic.
4.Then insert the right
edge into sideling.
5.Push the left edge
and move to left.
3.Change the name
plate
Unit: mm
Door/Wall Panel Frame
PC plate Screw
Door station
Indoor phone
Camera MIC
Speaker Call button
Name plate Sensitive LED
Status indicator
Power Supply indicator
Busy indicator
Mute indicator
Buttons
Adjustment
Talk button
Monitor button
Unlock button
Internal call button
Brightness Adjustment
Contrast Adjustment
Chroma Adjustment
Talk Volume Adjustment
Ring Volume Adjustment
6. Specifications
Indoor phone Jumper Setting
There are several jumpers on indoor phone rear panel, adjust them as follows:
91mm
8
0
m
m
6
9
m
m
66mm
Size:
6 3
phone as the main indoor phone, and set the others as
subsidiary indoor phone, adjust the jumper as follows:
If have more then one indoor phone, set one of indoor
Main indoor phone Subsidiary indoor phone
2.
The unlock time on the indoor phone can be
set separately. Adjust the jumper as follows:
Unlock time setting
Unlock time: 1s Unlock time: 5s
3.
The last indoor phone's Video matching jumper should
be "ON". The "
Video matching
System Diagrams" has the details.
Video matching: ON Video matching: OFF
1. Main indoor phone setting
If have one indoor phone, adjust the
jumper as follows:
[Note] Please disconnect the power when setting the jumpers, after completing, restart
the indoor phone.
Mind the installation size while producing a groove for the back cover.
Control the depth of the groove carefully so that it is the same as the one of the back
cover.
We suggest the installation height between 1100mm and 1400mm.But please also
consider other situations such as view angle of the camera and disabled persons.
Don't install door station near humid ,stove, and dusty condition.


There are waterproof silicon sheet attached on the door station's back side, please
install the door station to the smooth wall to guarantee the waterproof function.

Installation tips
3. Indoor Phone Installation
Unit: mm Bracket
Method 1 Method 2
4. Door Station Switch Installation
185X120X31
66mm
60mm
110X86X20
Method 1 Method 2
B: Black & White
(or it is color)
N: Built-in power supply
Number: Lcd screen size
Operating voltage:
Operating current: 7
Quiescent current: 10
Temperature:
Humidity:
Resolution:
DC 14V
00mA(DC 14V)
0mA(DC 14V)
-10~+55
10~95
Screen size: 4CRT/ 5TFT/ 7TFT
450 Line/320*324/480*324
Camera
Door
station
model
F5D10
F5D50
F5S50
F5S60
F5S70
F 5 D1 0 - C
Function:
Call/Talk/Access control
Shell No.
Villa door station code
Four-wire system
F3010 /F3030 / F3110 / F3120
/ F3190/ F3H40
F 3 03 0 - X
Function:
Call/Talk/Access control
color camera
(or it is B ) &W
Black & White
1/3 CCD&CMOS
PAL system
Visible angle: 90
Light source: infrared
Min. Illumination:
0.1 Lux
Color
1/3 CCD&CMOS
PAL system
Visible angle: 90
Light source:
white light LED
Min. Illumination:
0.1 Lux
Indoor
phone
model
Shell No.
Indoor phone code
Four-wire system
Operating voltage:
Operating current:
Quiescent current:
Temperature:
Humidity:
DC 14V
200mA(DC 14V)
30mA(DC 14V)
-40~+70
10~95
Technical
parameter
Technical
parameter
Signal unlock (Note: this way of unlocking needs separate power supply.)
NC
NO
COM
NC
NO
COM
Power unlock
(Note: only F5D10, F5D50, and F5S50
have this function)
NC
NO
COM
+12V
GND
Short circuit
Magnetic
lock
Power
supply
Door station
terminal
Power
supply
Door station
terminal
Electric lock
Electric lock
Door station
terminal
NC connection NO connection
NC
NO
COM
AUDIO
GND
VDOOR
VIDEO
Door station
Indoor phone
2 4
Lock
Power supply
AUDIO
GND
VDOOR
VIDEO
2
4
2
2
4
4
AUDIO
GND
VDOOR
VIDEO
3
2
4
1
3
2
4
1
3
2
4
1
-
+
D
C
1
4
V
AUDIO
GND
VDOOR
VIDEO
GND
[Note] Switch have two method to get the
power supply.
1. Separately power supply.
2. Power supply from indoor phone.
5. iagrams System D (one door station)
4 5
AUDIO
GND
VDOOR
VIDEO
AUDIO
GND
VDOOR
VIDEO
GND
DC14V
GND
DC14V
AUDIO
GND
VDOOR
VIDEO
Video matching
AUDIO
GND
VDOOR
VIDEO
GND
Video matching
AUDIO
GND
VDOOR
VIDEO
-
+
DC14V
GND
DC14V
[Note] 1. system can connect
with 1~4 indoor
phones.
2.The last indoor phone's
video matching jumper
should be "ON".
use the power supply from the indoor
phone, the wiring as follows:
Power supply
Indoor phone
Indoor phone
Power supply
Door station terminal
Indoor phone terminal
Indoor phone terminal
Indoor phone terminal
(Last one)
5. iagrams System D (two door stations)
Magnetic lock
Door station 1
Door station 2
Power supply
Power supply
Power supply
Indoor phone
Indoor phone
Indoor phone
Door station
terminal
Door station
terminal
Power supply
(optional)
Power supply
Power supply
Indoor phone
terminal
Indoor phone terminal
Indoor phone terminal
(Last one)
Door station
switch
D
o
o
r

s
t
a
t
i
o
n

2
I
n
d
o
o
r

p
h
o
n
e
D
o
o
r

s
t
a
t
i
o
n

1
Power supply
Door station switch
terminal
Indoor phone
terminal
Video matching
Video matching
Video matching
Video matching
Wiring suggestion:
Wiring distance from door station to the last
indoor phone should be less than 100m.
1. If distance 50m, use quad cable, with the
single wire resistance 4. Recommend
RVV40.75 wire.
2. If distance50m, use 3-core cable and
coaxial-cable, with the single wire resistance
4. Recommend RVV31.0 and SYV-75
wire.
1) VDOOR, AUDIO, GND terminal use 3-core
cable.
2) VIDEO, GND terminal use coaxial cable.
Door station
switch
4
4
4
4
DC14V
DC14V
Electric lock
!
The wiring between indoor
phones must be connected
hand in hand, as the right
diagrams shows.