Meter is designed especially for those regions / areas where power theft is a major concern. The meter is protected against Electrostatic Discharge (ESD), Surge Immunity, AC / DC Magnetic Fields as per IEC 61000-X-X requirements. When one of the input wires i.e. Phase or neutral is disconnected or fan dimmer used to tamper the meter then Alarm LED on meter name plate lights up and segment of Reverse Energy Flow "Erth" appears
Meter is designed especially for those regions / areas where power theft is a major concern. The meter is protected against Electrostatic Discharge (ESD), Surge Immunity, AC / DC Magnetic Fields as per IEC 61000-X-X requirements. When one of the input wires i.e. Phase or neutral is disconnected or fan dimmer used to tamper the meter then Alarm LED on meter name plate lights up and segment of Reverse Energy Flow "Erth" appears
Meter is designed especially for those regions / areas where power theft is a major concern. The meter is protected against Electrostatic Discharge (ESD), Surge Immunity, AC / DC Magnetic Fields as per IEC 61000-X-X requirements. When one of the input wires i.e. Phase or neutral is disconnected or fan dimmer used to tamper the meter then Alarm LED on meter name plate lights up and segment of Reverse Energy Flow "Erth" appears
EN ERGY METER R- 2 8 3 Re d e f ining Te chnolog ica l Horiz ons Re d e f ining Te chnolog ica l Horiz ons R283 Electronic Single Phase Energy Meter is developed for domestic and commercial users. It is designed especially for those regions/areas where power theft is a major concern. This model comes up with comprehensive Anti-Tampering features. State of the art Digital Signal Processor and highly accurate Sigma Delta ADC integrated circuits have been incorporated to measure kWh. Current (I) sensors are provided on both Neutral and Phase wires to record/measure the energy in case of different tampering conditions. Fulfills IEC 62052, class 1 accuracy requirements. The meter is protected against Electrostatic Discharge (ESD), Surge Immunity, AC/DC Magnetic Fields as per IEC 61000-X-X requirements. Seven digits register showing energy consumption (kWh) kWh reading display on LCD in case of power outage/failure Meter can also measure voltage, phase current and neutral current (Optional) Low battery indication ( ) when 25% life of the battery is left Error indication (Error 1/Error 2) in case of hardware/software faults Pulse output (3200 impulses/kWh) displayed via LED on meter name plate R-283 Features (Contd......) Self diagnostic of memory Reliable LCD with ultraviolet protection No effect of tilt on meter accuracy Resistant against dust & moisture Anti Tampering Features When one of the input wires i.e. phase or neutral is disconnected or fan dimmer used to tamper the meter then Alarm LED on meter name plate lights up and segment of Earth Fault Detection Erth appears on LCD. In this condition meter keeps on billing by measuring the current flow (Current = 1 Amp) with reference voltage and unity power factor. When meters input and output are interchanged/reversed to tamper the meter, then Alarm LED on meter face plate lights up and segment of Reverse Energy Flow Rev displays on LCD, which indicate that the connection of meter are reversed. However, in this case the meter keeps on recording energy accurately. Protection against external influence such as strong Electromagnetic field, Radar magnet, CD drive, etc. Electrical Specifications: Operating Voltage 240 Volt Basic/Max Current 10/40 Amp Reference Frequency 50Hz Accuracy Class 1.0 Meter Constant 3200 imp/kWh Starting Current 40mA Power Consumption o Voltage Circuit Less than 2W, 10VA o Current Circuit Less than 4VA (at basic current) Initial Start up Time After 5seconds of supply of rated voltage Billing Record Monthly reading for last 24 months of 4 tariffs and totals (TL) of the following: kWh kvarh Cumulative MDI(kW) Current Month MDI(kW) Avg. Power Factor(PF) Temperature Range: Storage -25 C to 80 C Operating -25 C to 60 C Relative Humidity: Storage 0 to 95% Operating 0 to 95% Weight & Dimension: Weight 1.26 Kg Dimension 23.9cm 16.4cm 8cm Windows Displays Sequence: Each window displays for 5 seconds and scrolls automatically. 01. Meter Serial Number. 02. Active Energy (KWh) 03. Maximum Demand Interval (MDI) of Last Month (KW) 04. Maximum Demand Interval (MDI) of Current Month (KW) 05. Instantaneous Active Power (KW) CONNECTION DIAGRAM & INSTRUCTIONS Connection Diagram Dielectric Strength: Power Frequency Withstand 4 KV for One Minute Impulse Voltage Withstand 8 KV: 1.2/50 Micro Sec. Short Time over Current 1200 Amperes for 0.5 Sec Insulation Resistance More than 5 Mega Ohms. Creepage Distance 20mm Minimum DC Magnetic Field 1000 Amp/Turns AC Magnetic Field 400 Amp/Turns Electromagnetic Compatibility/ Disturbance (EMC): Electro Static Discharge IEC 61000 4 2 Radio Interference IEC 61000 4 3 Fast Transient Burst IEC 61000 4 4 Surge Immunity IEC 61000 4 5 Damp Oscillatory Wave Immunity IEC 61000 4 12 Attari I ndustrial Estate, Plot # 2, Street # 2 18 KM. Ferozepur Road, Lahore- Pakistan PABX : +92-42-35990015 Tel: +92-42-35924781-4 Fax: +92-42-35924780 E-mail: marketing@mtilimited.comURL: www.mtilimited.com
The Exciting Impedance Ze of The Auxiliary Transformer T and The Capacitance of The Potential Divider Together Form A Resonant Circuit That Will Usually Oscillate at A Certain Frequency