Sunteți pe pagina 1din 20

5A-9Aconvert1C.

ppt
1
5A to 9A Stroker.
Electronic Controller Conversion
Guideline Manual.
Part Numbers:-
Conversion Kit :- S20-18478-0
Active unit:- S20-18337-0
Passive unit:- S20-18338-0
5A-9Aconvert1C.ppt
2
Take a few minutes to FULLY read THESE information / data sheets BEFORE starting.
Make sure the unit supply voltage is the same as the coils on thevalve being driven ( i.e. 24VDC ) !
Ensure that you are aware of the available adjustments on the electronics controller and hydraulics.
Make sure you have the correct tools to do the intended job ( i.e. D.V.M. ) e.t.c.
Ensure that any link options have been correctly selected BEFOREapplying power.
Isolate this unit from all other equipment BEFORE any form of welding takes place.
Check ALL connections to and from this unit to ensure correct connectionswith NO short circuits.
Make sure that Screened cable is used where recommendedin the application data sheets.
Start operating a new system at LOWpressure and with SMALL command signals.
Ensure that each valve coil has dedicated wires ( where required ) to the connector for correct operation.
Check that the units supply voltage is CORRECT, ELECTRICALLY CLEAN and STABLE.
Fit correctly rated In-Line fuses on all SUPPLY and OUTPUT lines to protect unit if recommended.
Operate the units within the specified operating temperature range for best & reliable performance.
Ensure that any unused wires / terminals are terminated safely and not shorted together.
Contact Parker Denison HPD, Marysville, for additional information if you are still unsure of connecting this unit.
ALWAYS
Arc Weld or Charge Batteries while this driver unit is connected as damage may be caused.
Connect this units input in series OR parallel with another as damage may occur.
Attempt to use this unit if you are unsure of connections or expected operation.
Attempt to use this unit in Areas where AC or DC coils HAVE NOT been fully suppressed.
Attempt to use a power supply that is not rated for the correct required O/P current under full load.
Allow wires TO or FROM the unit to be short circuited ( to each other or chassis/cabinet e.t.c. ).
Attempt to use this unit in areas of intense RF without adequate screening measures.
Disconnect or connect wires to or from this unit unless it it isolated from the power supply.
Wherever Possible.
IMPORTANT NOTE :-
Before starting to install or Apply any Parker Denison electronic control products, please read the Helpful Hints for Trouble
Free Application and Use of Electronic Driver cards and Modules booklet which is on the Parker Denison literature website.
NEVER
Keep High Voltage AC cables separate from Low Voltage DC signal and supply cables.
5A-9Aconvert1C.ppt
3
Parker Denison has always been a leader in product quality, operation longevity and innovation regarding the
piston products range. Over the years and as technology has changed, new methods of controlling the piston
pumps have been developed that allow the operator new unprecedented levels of control and system
optimization that could not be realized before and cannot be matched by our competitors today.
Advances in manufacturing techniques, materials and general Electro-hydraulic controls has seen a reduction
in overall size, complexity and moving parts while increasing accuracy, repeatability and operating life. With
this in mind, this manual is intended to guide you through the upgrade from the 5A electro-hydraulic pump
stroker to the newer generation 9A version.
The 9A Electro-hydraulic pump stroker offers many benefits, some of which are being more cost effective,
easier to maintain, more reliable over time while still offering the best performance from the piston pumps or
motors in the applications it is used with.
Introduction:
Methodology:
The conversion process described in this manual covers the electronic needs only, and will allow the user to
control the 9A stroker without adding or increasing wire count between the existing controller location and the
pump. This is an enormous advantage especially during retro-fit applications. This method also does not
require any local power to be applied at the pump, again a major advantage during the re-fitting process.
The converter unit has been designed to cater for several user configurations and comes with user selectable
links that allow choice of in-circuit or out-circuit 30 load resistor, differential or Normal input signal amplifier
and user +/-10V outputs for local connection to joysticks e.t.c.
The unit also comes with visual indicators that show power on status as well as which output ( A or B ) is
being powered.
The converter comes factory set to give the following I/O characteristics:-
100% +Volts DC Input ( **based on +300ma into 30 ) = 100% +Output = approx. PWM +300mA.
100% -Volts DC Input ( **based on -300ma into 30 ) = 100% -Output = approx. PWM -300mA.
The output current settings can be changed by the user if required by using the I Min and I Max adjustments
provided for each coil driver output. DO NOT overdrive the stroker coils or long term damage may occur due
to overheating.
The output PWM frequency is factory set to 140Hz. This may also be changed if required by the user.
**Note:- These values will alter slightly due to the Heating effect the input signal will have on the 30
resistor if used.
Approvals:
Both the active Stroker Converter Unit ( SCU ) and the pump mounted Passive Converter Unit ( PCU )
have been tested to and passed the current CE regulatory tests for the following standards:
EN-12895 Industrial trucks ( Emissions ) and
EN-12895 Industrial trucks ( Immunity ).
The unit has been further tested to the new Euro-Norms of:-
EN-61000-6-3 Generic Emissions for domestic & Light industrial
EN-61000-6-2:2001Generiv immunity for industrial environments
Use of this controller under conditions not specified by EN-12895 will require the user to clarify the application
with Parker Denison technical staff before proceeding.
To maintain compliance with the tested EMC specifications listed above, the converter must only be connected
to the vehicle battery supply and must NOT be allowed to control or operate the pump system while the
vehicle is connected to ANY external power supply ( I.e. battery Charger or engine warmer e.t.c.) and must be
fully isolated from external supplies if this situation occurs .
This controller has been designed specifically to operate with the Parker Denison range of pumps and 9A
electro hydraulic strokers.
Use of the controller with products other than those mentioned above or for applications outside those shown
will require clarification with Parker Denison technical personnel at:
5A-9Aconvert1C.ppt
4
Connectors: The connectors used are of the AMP SUPERSEAL 1.5 Series variety and are easily available from most
electrical suppliers. Details of the wire crimp are shown below this text.
The main SCU has 1 x 6 way male ( Main I/O ) and 1 x 2 way female ( Output to PCU ), Attached to the
unit and comes with the mating half connectors for customer connection on the application.
Stroker Converter Unit ( SCU )
Factory settings
165mA
-0.125V
+0.125V
165mA
+10V
300mA
-10V
300mA
Fig 1
I Min A 165mA @ +0.125V
I Max A 300mA @ +10V
I Min B 165mA @ -0.125V
I Max B 300mA @ -10V
Dither Frequency 140Hz
LK 1 - Load select OUT
LK 2 - Normal amplifier - IN
Number of positions: 1 to 6
Contact material: CuZn (brass), CuSn (phosphor bronze), pre-tin
Housing material: polyamide 6.6 glass filled UL-approved
Sealing: Silicon rubber, yellow
Contact sections: 0.35 - 2.5 mm
Current load: 14 A maximum
Processing: Hand-tool semi- and fully-automatic
Accessories: Protective sleeve for 2, 3 and 5 positions
Dielectric withstanding: 1,5 kVAC
Temperature range: -40 to +125C
Operates
A coil
Operates
B coil
5A-9Aconvert1C.ppt
5
Pre-Installation
Instructions:
5A coil resistance simulation ( loading )
LK 1.
1. Ensure command signal power supply 0V is
connected to the converter power supply 0V.
2. Check if command source needs resistive load
( simulating the 5A stroker ) to operate correctly.
3. If 30 load IS REQUIRED, ensure that LK1
( see this page or page 13 for full block diagram
details ) is in the IN position.
4. If load is different to 30 provided, ensure that
LK1 is in the OUT position then select external (
customer supplied ) resistor value needed and fit
across command source output as required.
5. If NO resistive load is required, ensure that LK1
is in the OUT position.
Input Amplifier Configuration
LK 2.
1. Ensure command signal power supply 0V is connected to the converter power supply 0V.
2. If the command source requires a Load, follow the instructions above to ensure correct operation, and
set LK2 to the Diff ( differential ) input select position.
3. Connect the two wires from the command source across the +V input and V input terminals in the
Input connector ( see page 12 for connector pin details ) being careful to observe polarity.
4. If the command source DOES NOT require a load, set LK2 to the NORM ( Normal ) input select
position.
5. Connect the +/-Voltage wire to the +V input only ( -V input is connected to 0V by LK2 ).
See page 14 for adjustment and link locations on this
module.
30 Load resistor
5 watts.
0V
LK 1
LK 2
NOTE:
LK 2 Shown in NORMAL I/P
mode
NOTE:
LK 1 Shown with NO
load connected
Input amplifier
and signal
conditioning
+I/P ( Voltage
Command only )
NORM
DIFF
Common
-I/P ( Voltage Command
only )
IN
OUT
Common
30 Load
5A-9Aconvert1C.ppt
6
Dry Test Instructions: - NO HYDRAULIC POWER IS NEEDED FOR THIS TEST !!
1. The SCU is factory set to give 165mA I Min at 0.125VDC command I/P and 300mA I Max at 10VDC. ( see fig 1 on
page 4 ). Adjustments have been provided to allow the user to change these settings if required ( see page 12 for locations )
2. Ensure command source is set to zero output volts (0V).
3. Apply +24VDC power to the SCU and ensure the BLUE Power On light is on and bright.
4. Increase the + direction command a small amount off zero and see that the YELLOW A coil LED lights.
5. Slowly increase the command to give MAX Positive (+) O/P volts and ensure that the YELLOW A coil LED lights brightly.
6. Return command to zero volts (0V) O/P position.
7. Increase the direction command a small amount off zero and see that the GREEN B coil LED lights.
8. Slowly increase the command to give MAX Negative (-) O/P volts and ensure that the GREEN B coil LED lights brightly.
9. Return command to zero volts (0V) O/P position.
Main Instructions:
8. Re-connect the existing 2 way female MS style connector ( in 5. ) to the new 2 way male MS style receptacle on the PCU.
9. Connect the GREY 3 pole connector marked A to the 9A stoker A coil and securely tighten the locking screw.
10. Connect the BLACK 3 pole connector marked B to the 9A stoker B coil and securely tighten the locking screw.
11. Check that ALL the PCU mounting hardware is securely tightened ( PCU to bracket and bracket to 9A stroker ).
12. Physically install the Stroker Converter Unit ( SCU ), P/No. S20-18337-0 to in-cab location to meet unit environmental
specifications using hardware ( customer supplied ) that will allow for safe and reliable usage in the intended working
environment ( see page 14 & 15 for details).
13. Where possible, remove old controller unit completely to simplify system and wiring connections ( see connection options ).
14. DISCONNECT the existing 2 core cable going to pump stroker from old electronic controller and Install new 2 way male AMP
SUPERSEAL 1.5 Series supplied connector onto cable, observing wire polarity noted in 4. at all times.
15. Mate newly installed 2 way male AMP SUPERSEAL 1.5 Series connector to 2 way polarized, female AMP SUPERSEAL 1.5
Series connector from main converter unit ( S20-18337-0 ).
16. Decide whether to use a Passive or Active configuration ( see pages 8 thro 11 for details )
17. For ACTIVE system, refer to pages 8 & 9.
18. For PASSIVE system, refer to pages 10 & 11.
19. Check ALL mechanical connections and mounting hardware are correct, intact and tight.
20. Connect SCU to fused ( 1 amp delayed ) +24VDC power supply.
1. Ensure pump to be worked on is commanded to zero stroke from existing controller.
2. Power down the hydraulic system connected to the pump to be converted.
3. Power down the existing electronic controller unit.
4. BEFORE any disconnection takes place check and make accurate notes of existing system cable connections, any
colors and signal polarities. This information will be used as a reference for connections using the NEW converter
units and should be kept safe until the new installation is proved to be fully functional.
5. Dis-connect ( Un-screw only ) the 2 way female MS style electrical connector from the 5A stroker.
6. Mechanically exchange the pump mounted 5A for the new 9A electro-hydraulic stroker using separate instructions supplied.
7. Mount NEW Passive Connector Unit ( PCU ), P/No. S20-18338-0 to 9A stroker assembly as shown in this document
( see pages 16, 17 & 18 for details ).
5A-9Aconvert1C.ppt
7
NOTE:- EXTREME CARE SHOULD BE TAKEN WHILE MAKING ADJUSTMENTS TO AVOID
OVERDRIVING THE 9A COILS AND/OR OVERSPEEDING EQUIPMENT ATTACHED TO THE
PUMP.
1) If it is found that the pump is stroking ABOVE MAXIMUM ( which will be exhibited as the pump reaching full stroke
BEFORE the command input is at 100% ), adjustments to the I Max settings should be made to re-calibrate.
2) If it is found that the pump IS NOT stroking to maximum with the factory pre-settings, adjustments can be made with the
aide of an in-line current meter measuring D.C. CURENT at the coil being driven,
1. You are about to stroke the pump in a live test to prove functionality. Ensure that the area is clear and that people are
aware that machinery may move unexpectedly.
2. Ensure command source is set to zero output volts (0V).
3. Apply +24VDC power to the SCU and ensure the BLUE Power On light is on and bright.
4. Increase the + direction command a small amount off zero and see that the YELLOW A coil LED lights.
5. Check that the pump is beginning to stroke the correct way.
6. Slowly increase the command to give MAX Positive (+) O/P volts and ensure that the YELLOW A coil LED lights brightly.
7. Return command to zero volts (0V) O/P position.
8. Increase the direction command a small amount off zero and see that the GREEN B coil LED lights.
9. Slowly increase the command to give MAX Negative (-) O/P volts and ensure that the GREEN B coil LED lights brightly.
10. Return command to zero volts (0V) O/P position.
Wet Test Instructions: - HYDRAULIC POWER IS NEEDED FOR THIS TEST !!
5A-9Aconvert1C.ppt
8
Active Joystick with
internal D.C. voltage
driver for direct
connection to 5A stroker.
Existing 2 wires
to old 5A stroker
used to transmit
new PWM signal
for 9A stroker
Part Number:
S20-18338-0
Made in U.K.
Passive
connector
unit.
C
o
i
l

C
o
i
l

Passive PWM steering unit fitted to 9A pump


stroker for easy new or retro-fit connection.
Active Joystick with
internal D.C. voltage
driver for direct
connection to 5A stroker.
+24 VDC
2 wires to 5A stroker
300mA approx.
Existing Configuration
NEW Configuration Setting Information:
LK 1 = Load IN
LK 2 = DIFF position
I Min & I Max to suit
Dither at Factory setting ( 140Hz )
ACTIVE system.
(1) (2)
(5)
(6)
New 2 WAY male
AMP Superseal
series 1.5
connector.
2 WAY female
AMP
Superseal series
1.5 connector
from SCU.
1
2
Part Number:
S20-18337-0
5A to 9A
Electro-Hydraulic
Stroker Converter Unit.
Made in U.K.
Power ON
Output A ON
Output B ON
1
2
+24 VDC
Stroker Converter Unit
( SCU )
5A-9Aconvert1C.ppt
9
NOTES:-
1) Control using Active Joystick with integral DC
current driver.
2) Ensure the load resister is connected if required
to make command signal source work correctly.
( see page 13 for location and full instructions ).
3) Ensure that LK2 is set to allow differential amplifier
configuration.
+24VDC
0VDC
+V Output from
joystick / controller
Existing 2 core cable with
new plug fitted at SCU
end.
Existing 2 pole connector,
removed from 5A stroker and
plugged directly into pump
mounted passive Connector
unit ( PCU ).
DIN 43650 connectors.
Positive signal activates
coil A
Negative signal
activates coil B
Cannon 2 pole connector.
Passive unit mounted on rear of
coil protection extrusion.
Connection Diagrams:
0V Output from
joystick / controller
Drawings NOT to scale !
ACTIVE system.
Part Number:
S20-18337-0
5A to 9A
Electro-Hydraulic
Stroker Converter Unit.
Made in U.K.
Power ON
Output A ON
Output B ON
Stroker Converter Unit ( SCU )
A M P
1
2
3
4
5
6
1
2
1
2
1
2
3
4
5
6
A M P
FEMALE
MALE
FEMALE
MALE
( PCU )
5A-9Aconvert1C.ppt
10
A.C Volts
2 wires to 5A stroker
300mA approx.
Command I/P
NOTE: Jupiter 5A driver card
removed to simplify the system.
PCU steering unit fitted to 9A pump stroker for
easy new or retro-fit connection.
Existing Configuration
NEW Configuration
Command I/P
Passive joystick or
potentiometer
Jupiter or other 5A
controller.
Passive joystick or
potentiometer
Setting Information:
LK 1 = Load OUT
LK 2 = NORM position
I Min & I Max to suit
Dither at Factory setting ( 140Hz )
PASSIVE system.
Existing 2 wires
to old 5A stroker
used to transmit
new PWM signal
for 9A stroker
(1) (2)
(3)
(5)
(4)
New 2 WAY male
AMP Superseal
series 1.5
connector.
2 WAY female
AMP
Superseal series
1.5 connector
from SCU.
1
2
1
2
Part Number:
S20-18337-0
5A to 9A
Electro-Hydraulic
Stroker Converter Unit.
Made in U.K.
Power ON
Output A ON
Output B ON
Part Number:
S20-18338-0
Made in U.K.
Passive
connector
unit.
C
o
i
l

C
o
i
l

+24 VDC
Stroker Converter Unit (
SCU )
5A-9Aconvert1C.ppt
11
Part Number:
S20-18337-0
5A to 9A
Electro-Hydraulic
Stroker Converter Unit.
Made in U.K.
Power ON
Output A ON
Output B ON
NOTES:-
1) Control using a Passive potentiometric style
joystick or command source.
2) Ensure the load resister is disconnected
( see page 13 for location and full instructions ).
3) Ensure that LK2 is fitted in the NORM position.
+24VDC
0VDC
-10VDC 10VDC
Command
signal
Existing 2 core cable with
new plug fitted at SCU
end.
Existing 2 pole connector, removed
from 5A stroker and plugged directly
into pump mounted passive
connector unit ( PCU ).
Cannon 2 pole connector. Passive
unit mounted on rear of coil
protection extrusion.
Drawings NOT to scale !
Connection Diagrams:
DIN 43650 connectors.
Positive signal
activates coil A
Negative signal
activates coil B
PASSIVE system.
1
2
1
2
1
2
3
4
5
6
A M P
+10VDC
A M P
1
2
3
4
5
6
FEMALE MALE
FEMALE
MALE
( PCU )
Stroker Converter Unit ( SCU )
5A-9Aconvert1C.ppt
12
Specifications ( Stroker Converter unit ( SCU ) S20-18337-0 ):
1) Board Style: Parker Denison Unique Size and Mounting.
2) Input Connector Type: 6 way male AMP Superseal connector series 1.5
3) Output Connector type: 2 way female - AMP Superseal connector series 1.5
4) Input Supply Voltage(s): 24V D.C. ( +18 - +32VDC absolute maximum )
5) Input Supply Current ( Max ): Maximum Valve Current Setting + 50mA Quiescent (Max)
6) Command Input Type(s): DC Voltage or current
7) Command Input Value(s): 0 to +/- 10VDC ( max ) or 0 300mA ( max )
8) Input resistance: 10 K +/- 5% ( when NOT in differential mode )
9) Input type: Normal or Differential amplifier ( Link selectable ).
10) Load resistor value: 30 ( 5% ) @ 5 Watts ( max ).
11) User voltages: 10VDC @ 5mA / output, current limited for protection.
12) Available adjustments: I Max ( A & B ) , I Min ( A & B )
Dither Frequency adjust ( Common setting for A and B coils ).
13) Dither Frequency :( on coil output ) Variable from 100Hz to 300Hz ( +/- 20% )
14) Environmental: Totally ENCAPSULATED Printed Circuit Board.
15) IP Rating SCU unit : IP68 ( Min ) ( When assembled correctly )
16) NEMA Rating: NEMA 6P
17) Humidity: 95% Non Condensing.
18) Storage temp.: 120 Deg C ( 250F ) Max.
19) Working temp.: -40 Deg C ( -40F) Max
+70 Deg C ( 160F ) Max Inc Ambient.
20) Enclosure Material: Aluminium alloy.
Pin
1
2
Function
+ Output to PCU
- Output to PCU
Pin Designations:
Note:-
Coil A operates from a + command signal.
Coil B operates from a command signal.
Drawings NOT to scale !
Output Connector
Input Connector
AMP
1
2
3
4
5
6
Pin
1
2
3
4
5
6
Function
+24V supply input
0V supply input
+10V ref @ 5mA
-10V ref @ 5mA
+V Input signal
-V Input signal
1
2
3
4
5
6
AMP
FEMALE
MALE
FEMALE
MALE
1
2
1
2
Stroker Converter Unit ( SCU )
5A-9Aconvert1C.ppt
13
S
t
r
o
k
e
r

C
o
n
v
e
r
t
e
r

U
n
i
t

(

S
2
0
-
1
8
3
3
7
-
0

)


B
l
o
c
k

D
i
a
g
r
a
m
.
D
.
C
.
D
.
C
.
I

M
i
n
I

M
a
x
0

5
0
0
m
A
I

M
i
n
I

M
a
x
0

5
0
0
m
A
F
.
E
.
T
.

O
u
t
p
u
t

S
t
a
g
e
F
.
E
.
T
.

O
u
t
p
u
t

S
t
a
g
e
O
u
t
p
u
t

P
o
l
a
r
i
t
y

S
t
e
e
r
i
n
g

C
C
T
.
P
o
w
e
r

s
u
p
p
l
y

p
r
o
t
e
c
t
i
o
n

a
n
d

c
o
n
v
e
r
s
i
o
n
+
1
0
V

r
e
f
-
1
0
V

r
e
f
-
O
/
P
+

O
/
P
D
i
t
h
e
r

F
r
e
q
u
e
n
c
y
I
n
t
e
r
n
a
l

S
u
p
p
l
i
e
s
.
A
L
L

a
d
j
u
s
t
m
e
n
t
s

a
r
e

c
l
o
c
k
w
i
s
e

t
o

i
n
c
r
e
a
s
e
+
1
0
V

u
s
e
r

r
e
f
e
r
e
n
c
e

o
u
t
p
u
t

@
5
m
A
-
1
0
V

u
s
e
r

r
e
f
e
r
e
n
c
e

o
u
t
p
u
t

@
5
m
A
+
2
4
V
D
C

s
u
p
p
l
y

i
n
p
u
t
-
I
/
P

(

V
o
l
t
a
g
e

C
o
m
m
a
n
d

o
n
l
y

)

C
h
a
n
n
e
l

.
C
h
a
n
n
e
l

.
N
O
T
E
:
A

p
o
s
i
t
i
v
e

(
+
)

v
o
l
t
a
g
e

o
n

t
h
e

I
/
P

w
i
l
l

a
c
t
i
v
a
t
e

c
h
a
n
n
e
l

.
A

N
e
g
a
t
i
v
e

(
-
)

v
o
l
t
a
g
e

o
n

t
h
e

I
/
P

w
i
l
l

a
c
t
i
v
a
t
e

c
h
a
n
n
e
l

.
0
V
D
C

s
u
p
p
l
y

i
n
p
u
t
3
0

L
o
a
d

r
e
s
i
s
t
o
r

5

w
a
t
t
s
.
0
V
L
K

1
L
K

2
N
O
T
E
:
L
K

2

S
h
o
w
n

i
n

D
I
F
F
E
R
E
N
T
I
A
L

I
/
P

m
o
d
e
N
O
T
E
:
L
K

1

S
h
o
w
n

w
i
t
h

N
O

l
o
a
d

c
o
n
n
e
c
t
e
d
I
n
p
u
t

a
m
p
l
i
f
i
e
r

a
n
d

s
i
g
n
a
l

c
o
n
d
i
t
i
o
n
i
n
g
)

+
I
/
P

(

V
o
l
t
a
g
e

C
o
m
m
a
n
d

o
n
l
y

N
O
R
M
D
I
F
F
C
o
m
m
o
n
I
N
O
U
T
C
o
m
m
o
n
3
0

L
o
a
d
5A-9Aconvert1C.ppt
14
Drawings NOT to scale !
NOTE:- Unit shown with Load IN-circuit and
Differential amplifier mode selected.
Converter unit
Adjustments:
Indicates
shorting
link
--------I/P
--------Diff.
---NORM.
A
Coil
B
Coil
I

M
a
x
I

M
i
n
Dither
Freq.
Load---
IN-------
OUT-----
I

M
a
x
I

M
i
n
L
K

1
L
K

2
ALL adjustments are
clockwise to increase
B Coil A Coil
Module REAR view
Converter unit
dimensions:
Unit lid
4mm
NOTE:- Unit shown
with NO lid attached
for clarity.
5A-9Aconvert1C.ppt
15
Drawings NOT to scale !
SPU Assembly Details:
The SCU is designed into an inverted enclosure. The base mounting plate is actually the enclosure lid which is
intended to be assembled to the main housing first using the 4 x countersunk screws provided. Once assembled
correctly, this protects the links and potentiometer adjustments after system calibration from unauthorized
access, tampering and also provides mechanical and environmental protection during usage.
Once the Lid has been securely attached to the main housing, the SCU can then be attached to the chosen
bulkhead / operating location by using customer supplied fasteners ( upto M4 ) suitable for extended use in the
bulkhead material.
Even though the SCU is fully encapsulated to give the best possible mechanical and electrical protection,
consideration for the SCU positioning should take into account the ambient and working temperature, vibration,
cable lengths / connections and other external environmental issues such as moisture ( condensation ) e.t.c.
when a mounting location is being decided upon.
All screws and/or fasteners used should be checked for tightness and correct fitting to ensure the operational
reliability of the SCU and the attached components.
NOTE: The diagnostic LEDs ( 2 x Green and 1 x Blue ) are low voltage and low current indicators
only and will not harm the operator or cause the unit to malfunction if broken.
Assemble lid to main
housing using 4 x countersunk
screws supplied. Ensure
tightness is correct.
Attach
assembled SCU to
operational position.
Ensure fastener
tightness ( M4
maximum ) is
correct.
3 x LED indicators
( Blue = power on,
Greens = Outputs
on )
Main housing
Enclosure
Lid
NOTE:- cables omitted from drawing for clarity.
Gasket cast as
part of the Lid to
aide assembly and
part location.
2
1 1
2
1
2
5A-9Aconvert1C.ppt
16
1) Board Style: Parker Denison Unique Size and Mounting.
2) Input Connector Type: 2 pole, Cannon P/N GS02-10SL-4P-111 connector
3) Output Connector A side Grey, DIN 43650.
4) Output Connector B side Black, DIN 43650.
5) Input type: PWM signal from SCU unit only
6) Available adjustments: None.
7) Environmental: Totally ENCAPSULATED Printed Circuit Board.
8) IP Rating: IP68 ( Min ) ( When assembled correctly )
9) NEMA Rating: NEMA 6P
10) Humidity: 95% Non Condensing.
11) Storage temp.: 120 Deg C ( 250F ) Max.
12) Working temp.: -40 Deg C ( -40F) Max
+70 Deg C ( 160F ) Max Inc Ambient.
13) Enclosure Material: Aluminium alloy.
14) Support bracket material: Anodised aluminium
Front view
Specifications ( Passive Converter Unit ( PCU ) S20-18338-0 ):
40mm
Part Number:
S20-18338-0
Made in U.K.
Passive
connector
unit.
C
o
i
l

C
o
i
l

Rear view
Top view Side view
C
L
C
L
50mm
5
0
m
m
26mm
4
0
m
m
4 off M3 threaded hole
-I/P ( PWM from
converter )
+I/P ( PWM from
converter )
Passive signal
steering
network.
Channel A
Passive signal
steering
network.
Channel B
Dotted line
indicates
passive
connector unit
enclosure
Block Diagram
17mm
5A-9Aconvert1C.ppt
17
Pump Hysteresis graph:
Mounting Options:
This graph shows the total pump
hysteresis ( 9A stroker + pump
mechanicals ) when using the
new SCU and PCU. The input
signal to the converter was a DC
current signal at +/-350mA
current capability ( applied to the
30 load ) with no dither to
simulate the type of signal that
would have been connected to
the original 5A stroker.
As can be seen from the result,
the converter allows the 9A
stroker and pump to perform as
expected.
This picture shows the two ways
that the passive unit can be
mounted depending on pump
orientation. With the passive unit
mounted in this way, coil
protection is maintained as well
as offering protection to the
passive unit and the 2 pole
connector. The anodised
aluminium support bracket comes
pre-assembled to the passive unit
and uses two bolts ( supplied ) to
fix mechanically to the 9A stroker
assembly as shown.
Drawings NOT to scale !
Electro-hydraulic Stroker +
Pump Hysteresis curve
5A-9Aconvert1C.ppt
18
Assembly Detail:
11 11
NOTE:
Use the 2 x bolts supplied with 9A stroker unit to secure this bracket/PCU
assembly to the stroker assembly.
5A-9Aconvert1C.ppt
19
FAQs and comments:
Q There is NO blue light on the SCU.
A Ensure the power supply to the SCU is turned on ( i.e. if run through ignition key circuit ).
Check fuse is correctly fitted and intact, change fuse if required.
Check power supply polarity to the SCU is correct.
Check the Power supply has enough current output capability and is not collapsing under load.
Q What if the pump strokes the opposite way to my old system.
A Check polarity of wires from SCU to PCU is correct. Change connection if required.
Check polarity of command input wires to SCU are correct. Change connection if required.
Q What are the part numbers for the connectors used ?
A The connector type is : AMP Superseal connector series 1.5
6 Way socket housing 282108-1
6 way pin housing 282090-1
2 way socket housing 282104-1
2 way pin housing 282080-1
Common Pin / socket seal 281934-4
Common Pin 183036-1
Common Socket 183036-1
2 pole MS female connector - T.B.A.
5A-9Aconvert1C.ppt
20
Notes:
Parker Hannifin Corporation.
Hydraulic Pump Division HPD
14249 Industrial parkway,
Marysville, OH, 43040.
Tel (1) 937-644-4564
www.denisonhydraulics.com
www.Parker.com