Sunteți pe pagina 1din 2

1755 La Costa Meadows Drive | San Marcos, California 92078 USA

760-744-6950 Toll Free (US): 800-854-1993 Fax: 760-736-6250


www.uidcomponents.com
Order Information Sheet (OIS)
ST98
FlexMASSter

Insertion Mass Flow Meter


INSTRUCTIONS: To order an ST98, please ll in the numbered Block above with the appropriate Code from the categories below. See Ordering Guide on page 2 for ST98 High Temperature. Once you
have determined all specications, contact an FCI representative or FCI directly for price information or additional options not shown. Consult FCI on the cost of special data and documentation. Final
acceptance of the part number is subject to FCIs approval.
Special Instructions
________________ ______________________________________
________________ ______________________________________
Block No. Code W or * Description
ST98
-
Block No. 1 2 3 4 5 6 7 8 9 10 11
Optional Accessories
9
Part # Description
FC88 Portable Hand-Held Communicator
014108-02 PC Interface Communication Kit
Code [ BLOCK 1 ] Flow Direction
1 Horizontal right to left, or vertical up
2 Horizontal left to right, or vertical down
Code [ BLOCK 2 ] Material of Construction
15
FPC Style Sensor
E 316 stainless steel (to 350 F [177 C])
G 316 stainless steel (to 500 F [260 C])
F Hastelloy-C276 (to 350 F [177 C])
H Hastelloy-C276 (to 500 F [260 C])
FP Style Sensor
3 316 stainless steel (to 350 F [177 C])
7 316 stainless steel (to 500 F [260 C])
4 Hastelloy-C276 (to 350F [177C])
8 Hastelloy-C276 (to 500F [260C])
S Style Sensor
1 316 stainless steel (to 350 F [177 C])
5 316 stainless steel (to 500 F [260 C])
2 Hastelloy-C276 (to 350 F [177 C])
6 Hastelloy-C276 (to 500 F [260 C])
W Agency approved, customer specied
* Other
Code [ BLOCK 9 ] Interconnecting Cable
0 Not required (customer supplied)
PVC Jacket
A 10 [3 m]
B 25 [7,6 m]
C 50 [15 m]
W Agency approved, customer specied
5
Code [ BLOCK 10 ] Calibration 1: Application
6, 7, 8, 9, 10
Standard Calibration
A Air: 1.25 SFPS to 125 SFPS; 10 psia to 65 psia; 40 F to 100 F
[0,4 NMPS to 38 NMPS; 0,7 bar (a) to 3,5 bar (a); 4 C to 38 C]
D Compressed air; 6 SFPS to 600 SFPS; 50 psia to 165 psia;
40 F to 100 F [1,8 NMPS to 183 NMPS; 3,5 bar (a) to 11 bar (a);
4 C to 38 C]
Custom Calibration
B Air
C Air equivalency (digester gas, ue gas, etc.)
E Nitrogen, helium, argon, carbon dioxide,
compressed air, or digester gas
F Hydrocarbons (natural gas, methane, ethane, propane, etc.)
G Hydrogen or hydrogen mixture
W Agency approved, customer specied
8
Code [ BLOCK 11 ] Calibration 2: Setup
0 Standard
9
A Temperature compensation
C Vortab (VEL, VFK, VIS, VMR or VSR)
1 Vortab (VIP)
D Flat velocity prole
F Temperature compensation and Vortab (VEL, VFK, VIS, VMR or VSR)
2 Temperature compensation and Vortab (VIP)
G Temperature compensation and at velocity prole
Code [ BLOCK 6 ] Insertion Length
1 1 to 6 [25 mm to 152 mm]
2 1 to 12 [25 mm to 305 mm]
3 1 to 21 [25 mm to 533 mm]
W Agency approved, customer specied
Code [ BLOCK 7 ] Enclosure
4
Integral Congurations
Nonincendive for Class I, Div. 2, Groups A, B, C, D;
Suitable for Class II, Div. 2, Groups F & G; Class III,
Div. 2 (meets IP66)
A Carbon steel, NEMA Type 4
1 Aluminum, NEMA Type 4X
Class I, Division 1 hazardous locations: Groups B, C, D,
E, F, G; ATEX/IECEx II2 GD Exd IIC
B Aluminum, NEMA Type 4X
Remote Transmitter Congurations
Local aluminum enclosure: NEMA Type 4X (meets IP67) Class I,
Div. 1, Groups B, C, D, E, F, G; ATEX/IECEx II2 GD Exd IIC
Local Remote
C Aluminum Carbon steel, NEMA Type 4
Approval per Code A
2 Aluminum Aluminum, NEMA Type 4X
Approval per Code 1
D Aluminum Aluminum, NEMA Type 4,
explosion-proof
Approval per Code B
E Aluminum None, panel mount
W Agency approved, customer specied
* Other
Code [ BLOCK 8 ] Transmitter Option
0 4-20 mA output, no display
A 4-20 mA output, with display
B HART protocol, 100 Vac to 240 Vac [50/60 Hz]
14

C HART protocol with display, 100 Vac to 240 Vac
[50/60 Hz]
14

D HART protocol, 9 Vdc to 36 Vdc
14
E HART protocol with display, 9 Vdc to 36 Vdc
14

F PROFIBUS DP Prole 3, no display
19

G PROFIBUS DP Prole 3, protocol with display
19
W Agency approved, customer specied
3
* Other
Code
3 4 5
[ BLOCKS 3-5 ] Process Connection
Compression Fitting
Teon Ferrule to 200 F [93 C], 150 psig [10 bar (g)]
C T 0 3/4 inch male NPT retractable with S style sensor
18
D N 0 1 inch male NPT retractable with FP / FPC style sensors
17
G

Flange
1, 17, 18
select Codes for Blocks 4-5 from Table A
Metal Ferrule
2
to 500 F [260 C], 250 psig [17 bar (g)]
M T 0 3/4 inch male NPT
18
N N 0 1 inch male NPT
17
J

Flange
1, 17, 18
select Codes for Blocks 4-5 from Table A
(continued next column)
Code
3 4 5
[ BLOCKS 3-5 ] Process Connection (continued)
Retractable Packing Gland with
Graphite Packing Material
16
Low Pressure to 50 psig [3,5 bar (g)]
P A 0 1-1/4 inch male NPT
Q

Flange
13
select Codes for Blocks 4-5 from Table A
Medium Pressure to 250 psig [17 bar (g)]
12
R A 0 1-1/4 inch male NPT
T

Flange
13
select Codes for Blocks 4-5 from Table A
W W W Agency approved, customer specied

* * * Other
g
For ST98 High Temperature
(850 F [454 C]), see page 2
Ordering Guide
Table A
Code [ BLOCK 4 ] Flange or NPT Size
Male NPT
T 3/4 inch (compression tting)
N 1 inch (compression tting)
A 1-1/4 inch (packing gland)
Raised Face Flange
1 ANSI 1 inch
B ANSI 1-1/2 inch
2 ANSI 2 inch
E DIN DN 25
G DIN DN 40
J DIN DN 50
W Agency approved, customer specied
1
Code [ BLOCK 5 ] Raised Face Flange Rating / Material
0 For male NPT only
G 150 lb material per Block 2
A 150 lb carbon steel
H 300 lb material per Block 2
B 300 lb carbon steel
2 DIN PN16 in 316L stainless steel
3 DIN PN40 in 316L stainless steel
W Agency approved, customer specied
1
Copyright 2010 Fluid Components International LLC. All rights reserved. Subject to change without notice. Order Information Sheet effective 01/2013 Doc. No. 01SA011441 W Page 1 of 2
Notes
*
Voids Agency Approvals. Contact FCI.
1. Flange is tapped and threaded for the 3/4 inch compression tting. All
ANSI anges are raised face phonographic serrated, all DIN anges are
Form C.
2. Material matches selection in Block 2. Metal ferrule permanently locks
after tightening compression tting.
3. Maximum length is 60 inches [1524 mm].
4. Enclosure required for agency approvals.
Notes (continued)
5. Overall shielded conductors required and wire resistance must
be less than 8 Ohms.
6. Turndown ratio is 10:1 minimum and 100:1 maximum.
7. FCI Standard Conditions are 14.7 psia [1,01 bar(a)] and 70 F [21,1 C].
8. Customer specied calibration must not exceed temperature
and pressure limitations of the ST98 product specications.
9. Transmitter setup, changes to factory supplied standard
settings, verication or modication to calibration parameters
or diagnostics requires external source communication with
the transmitter. Via RS232 port use Model FC88 communicator
or PC with PC interface kit or via HART bus (if selected) or
when PROFIBUS is selected, then must be performed via
PROFIBUS link.
10. Calibration codes must be selected using FCIs proprietary
AVAL application evaluation software.
12. Remote electronics is required.
13. The minimum ange size is 1-1/2 inches or DN40.
14. Isolated output and selectable passive or active output is a
standard feature with HART protocol. Flow range with HART
protocol must be 0 based.
15. T4 rated at 104 F [40 C].
16. Teon packing material must be ordered when the process
media is Ozone, Chlorine or Bromine (consult factory).
17. FP / FPC style sensors require 0.88 inch diameter minimum
clearance hole through process connection.
18. S style sensor requires 0.81 inch diameter minimum
clearance hole through process connection.
19. No mA output or RS232 available with PROFIBUS.
1755 La Costa Meadows Drive | San Marcos, California 92078 USA
760-744-6950 Toll Free (US): 800-854-1993 Fax: 760-736-6250
www.uidcomponents.com
Order Information Sheet (OIS)
ST98
FlexMASSter

Insertion Mass Flow Meter


INSTRUCTIONS: To order an ST98 HT, please ll in the numbered Block above with the appropriate Code from the categories below. Once you have determined all specications, contact
an FCI representative or FCI directly for price information or additional options not shown. Consult FCI on the cost of special data and documentation. Final acceptance of the part number is
subject to FCIs approval.
ST98 HT
-
.
Block No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Copyright 2010 Fluid Components International LLC. All rights reserved. Subject to change without notice. Order Information Sheet effective 01/2013 Doc. No. 01SA011441 W Page 2 of 2
Code [ BLOCK 1 ] Flow Direction
1 Horizontal right to left, or vertical up
2 Horizontal left to right, or vertical down
Code [ BLOCK 2 ] Material of Construction
15
FPC Style Sensor (to 850 F [454 C])
12
J 316 stainless steel
K Hastelloy-C276
FP Style Sensor (to 850 F [454 C])
12
A 316 stainless steel
B Hastelloy-C276
S Style Sensor (to 850 F [454 C])
12
C 316 stainless steel
D Hastelloy-C276
W Agency approved, customer specied
* Other
Code
[ BLOCK 10 ] Calibration 1:
Application
6, 7, 8, 9, 10
B Air
C Air equivalency (digester gas, ue gas, etc.)
E Nitrogen, helium, argon, carbon dioxide,
compressed air, or digester gas
F Hydrocarbons (natural gas, methane, ethane,
propane, etc.)
G Hydrogen or hydrogen mixture
W Agency approved, customer specied
8
Code [ BLOCK 11 ] Calibration 2: Setup
A Temperature compensation
F
Temperature compensation and Vortab (VEL, VFK,
VIS, VMR or VSR)
2 Temperature compensation and Vortab (VIP)
G
Temperature compensation and at velocity
prole
Code [ BLOCK 9 ] Interconnecting Cable
0 Not required (customer supplied)
5
Teon
D 10 [3 m]
E 25 [7,6 m]
F 50 [15 m]
W Agency approved, customer specied
5
Code [ BLOCK 6 ] Insertion Length
2 1 to 12 [25 mm to 305 mm]
3 1 to 21 [25 mm to 533 mm]
4 1 to 36 [25 mm to 914 mm]
5 1 to 60 [25 mm to 1524 mm]
A Fixed length; specify desired length in Blocks 12-14
W Agency approved, customer specied
3
Code [ BLOCK 7 ] Enclosure
4, 12, 20
Remote Transmitter Congurations
Local aluminum enclosure: NEMA Type 4X (meets IP67) Class
I, Div. 1, Groups B, C, D, E, F, G; ATEX/IECEx II2 GD Exd IIC
Local Remote
C Aluminum
Carbon steel NEMA 4: Nonincendive
for Class I, Div. 2, Groups A, B, C, D;
Suitable for Class II, Div. 2, Groups F
& G; Class III, Div. 2 (meets IP66)
2 Aluminum
Aluminum NEMA 4X: Nonincendive
for Class I, Div. 2, Groups A, B, C, D;
Suitable for Class II, Div. 2, Groups F
& G; Class III, Div. 2 (meets IP66)
D Aluminum Aluminum hazardous locations: Class
I, Div. 1 hazardous locations; Groups B,
C, D, E, F, G; ATEX/IECEx II2 GD Exd IIC
E Aluminum None, panel mount
W Agency approved, customer specied
* Other
Code
3 4 5
[ BLOCKS 3-5 ] Process Connection
For xed insertion length, Block 6 must be Code A
17
N N 0 1 inch male NPT
J

Flange select Codes for Blocks 4-5 from Table A
Retractable Packing Gland with
Graphite Packing Material
16
Low Pressure to 50 psig [3,5 bar (g)]
P A 0 1-1/4 inch male NPT
Q

Flange
13
select Codes for Blocks 4-5 from Table A
Medium Pressure to 250 psig [17 bar (g)]
12
R A 0 1-1/4 inch male NPT
T

Flange
13
select Codes for Blocks 4-5 from Table A
W W W Agency approved, customer specied
1
* * * Other
Table A
Code [ BLOCK 4 ] Flange
Raised Face Flange
B ANSI 1-1/2 inch
2 ANSI 2 inch
G DIN DN 40
J DIN DN 50
W Agency approved, customer specied
13
Code [ BLOCK 5 ] Raised Face Flange
Rating and Material
G 150 lb material per Block 2
A 150 lb carbon steel
H 300 lb material per Block 2
B 300 lb carbon steel
2 DIN PN16 in 316L stainless steel
3 DIN PN40 in 316L stainless steel
W Agency approved, customer specied
Notes
*
Voids Agency Approvals. Contact FCI.
3. Maximum length is 60 inches [1524 mm].
4. Enclosure required for agency approvals.
5. Overall shielded conductors required and wire resistance
must be less than 8 Ohms.
6. Turndown ratio is 10:1 minimum and 100:1 maximum.
7. FCI Standard Conditions are 14.7 psia [1,01 bar(a)] and 70 F
[21,1 C].
8. Customer specied calibration must not exceed temperature
and pressure limitations of the ST98 product specications.
9. Transmitter setup, changes to factory supplied standard
settings, verication or modication to calibration
parameters or diagnostics requires external source
communication with the transmitter. Via RS232 port use
Model FC88 communicator or PC with PC interface kit or via
HART bus (if selected) or when PROFIBUS is selected, then
must be performed via PROFIBUS link.
10. Calibration codes must be selected using FCIs proprietary
AVAL application evaluation software.
12. Remote electronics is required.
13. The minimum ange size is 1-1/2 inches or DN40.
14. Isolated output and selectable passive or active output is
a standard feature with HART protocol. Flow range with
HART protocol must be 0 based.
15. T4 rated at 104 F [40 C].
16. Teon packing material must be ordered when the process
media is Ozone, Chlorine or Bromine (consult factory).
17. Sensor requires 1.10 inch diameter minimum clearance hole
through process connection.
20. Agency approvals for system are pending.
Code [ BLOCK 8 ] Transmitter Option
Power
Supply
Digital
Display?
HART
Comm?
K 100 Vac to 240 Vac No No
(upgradable)
B 100 Vac to 240 Vac No Yes
14
L 100 Vac to 240 Vac
Yes No
(upgradable)
C 100 Vac to 240 Vac Yes Yes
14
H 22 Vdc to 30 Vdc
No No
(upgradable)
D 9 Vdc to 30 Vdc No Yes
14
J 22 Vdc to 30 Vdc
Yes No
(upgradable)
E 9 Vdc to 30 Vdc Yes Yes
14
W Agency approved, customer specied
* Other
Code [ BLOCKS 12-14 ] Insertion Length (Inches)
0 0 0 If Block 6 Code is 2, 3, 4 or 5
. If Block 6 is Code A, specify length in inches to 0.1
E.g. 08.5 is 8-1/2 inches. Minimum is 02.06,
maximum is 60.0
Optional Accessories
9, 11
Part # Description
FC88 Portable Hand-Held Communicator
014108-02 PC Interface Communication Kit

S-ar putea să vă placă și