Sunteți pe pagina 1din 3

DATA SHEET FOR FLOW METER

1 RESPONSIBLE ORGANIZATION FLOW DEVICE 6 SPECIFICATION IDENTIFICATIONS


2 7 Document no 3731-DSSA-4-13-0008
3 Operating Parameters

8 Latest revision 0 Date 09.07.2014
4 9 Issue status Issued for Comments
5 10

11 ADMINISTRATIVE IDENTIFICATIONS 40 SERVICE IDENTIFICATIONS Continued
12 Project number 3731 Sub project no NA 41 Inline hazardous area cl NA Div/Zon

2 Group IIC
13 Project EPIC of water storage tanks at ...

42 Inline area min ign temp NA Temp ident number T4
14 Enterprise NA 43 Remote hazardous area

NA Div/Zone NA Group NA
15 Site DSSA 44 Remote area min ign

NA Temp ident number NA
16 Area 88 Cell NA Unit NA 45
17

46
18 SERVICE IDENTIFICATIONS 47 COMPONENT DESIGN CRITERIA
19 Tag no/Functional ident 88-FIT-XXX1; 88-FIT-XXX2 48 Component type magnetic flow transmitter
20 Related equipment NA 49 Component style inline
21 Service Potable water 50 Output signal type digital
22

51 Characteristic curve linear with measurement
23 P&ID/Reference dwg

3731-DSSA-6-50-0001 52 Compensation style (note 1)
24 Upstr line/nozzle number NA 53 Type of protection (note 1)
25 Upstream line pipe spec L5-150-1 54 Criticality code (note 1)
26 Upstr line nominal size DN250 Rating PN16 55 Max EMI susceptibility (note 1) Ref (note 1)
27 Upstr line conn type flanged Style RF 56 Max temperature effect (note 1)
28 Upstr line schedule no Sch 30 Wall thickness 8,4 mm 57 Min diameter ratio (d/D) (note 1) Max (note 1)
29 Upstr conn orientation horizontal 58 Max response time (note 1)
30 Upstr line material type Carbon Steel FBE 59 Min required accuracy 0.5 Ref % span
31 Connection design code NA 60 Avail nom power supply 24VDC Number wires 2
32 Dnstr line/nozzle number NA 61 Min load capability (note 1)
33 Dnstr line pipe spec L5-150-1 62 Testing/Listing agency UL, CSA, BASEEFA
34 Dnstr line nominal size DN250 Rating PN16 63 Test requirements ATEX
35 Dnstr line conn type flanged Style RF 64 Supply loss failure mode NA
36 Dnstr line schedule no K9 Wall thickness 8,4 mm 65 Signal loss failure mode NA
37 Dnstr conn orientation horizontal 66
38 Dnstr line material type Carbon Steel FBE 67
39 Avail upstr straight lg 5xDN 250 Dnstr lg 5xDN 250 68
69 PROCESS VARIABLES MATERIAL FLOW CONDITIONS

101 PROCESS DESIGN CONDITIONS


70 Flow Case Identification max flow min flow norm flow Units 102 Minimum Maximum Units
71 Inlet pressure 5,4 - - bar (g) 103 0 2.5 barg
72 Outlet pressure 5,4 - - bar (g) 104
73 Inlet temperature 52 NA NA C 105
74 Inlet phase type Liquid Liquid Liquid 106
75 Mass fraction vapor NA NA NA 107
76 Total mass flow rate 250000 - - kg/h 108
77 Liquid mass flow rate 250000 - - kg/h 109
78 Liquid actual flow rate 250 - - m
3
/h 110
79 Liquid standard flow rate 250 - - m
3
/h 111
80 Liquid density 998.23 998.23 998.23 kg/m
3


112
81 Liquid specific gravity 0.998 0.998 0.998 113
82 Liquid viscosity 1.002 1.002 1.002 mPas (20C) 114
83 Absolute vapor pressure NA NA NA kPa 115
84 Vapor mass flow rate NA NA NA 116
85 Vapor actual flow rate NA NA NA 117
86 Vapor standard flow rate NA NA NA 118
87 Vapor density NA NA NA 119
88 Vapor specific gravity NA NA NA 120
89 Vapor molecular weight NA NA NA 121
90 Vapor viscosity NA NA NA 122
91 Inlet compressibility NA NA NA 123
92 124
93 CALCULATED

125
94 Pressure differential NA NA NA 126
95 Perm pressure drop 25 - - mbar 127
96 Line fluid velocity 2.01 - - m/s 128
97 Line Reynolds number NA NA NA (1l/min

129
98 Calculated uncertainty NA NA NA 130
99 131
132 MATERIAL PROPERTIES 13

MATERIAL PROPERTIES Continued
133 Name water 13

Abs critical pressure NA
134 Composition water 14

Critical temperature NA
135 Density at ref temp 998.23kg/m
3
At 20C 14

NFPA health hazard NA Flamma

NA React

NA
136 Ratio sp heat capacity 1.330 14


137 Conductivity 14500 to 40000uS/m 14



DOC. NO.: 3731-DSSA-4-13-0008 REV. 0 Page 2 of 3

Line Size for FIT-XXX1 is
DN300 and FIR-xxx2 is
DN250
As per tender documents, no gas
group mentioned.
Please mention tests
required. ATEX is a certifying
agency. Please correct.
51

DATA SHEET FOR FLOW METER

NOTES:
1. To be furnished by Vendor.
2. Digital Flow Totalizer / Rate Indication shall be displayed on the transmitter. Flow totalizer shall be calculated in the PLC panel and forward to SCADA.

1
2
3
4
5

RESPONSIBLE ORGANIZATION
MAGNETIC FLOWMETER
Device Specification

6
7
8
9
10

SPECIFICATION IDENTIFICATIONS




Document no
Latest revision
Issue status
3731-DSSA-4-13-0008
0 Date 09.07.2014
Issued for Comments

11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59

FLOWMETER BODY
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108

TOTALIZER INDICATOR
Body type
Flow tube style
End conn nominal size
End conn termn type
Flow tube diameter
Hardware mounting kit
Flow tube material
Lining material
End termination material
Gnd/protective ring matl
Flowtube Totalizer type
Enclosure type no/class
Signal power source
Contacts arrangement
Totalizer reset style
Integral indicator style
Cert/Approval type
Mounting location/type
Enclosure material
Forward total /gross(note 2)
(note 1) NA
DN250 Rating PN 16 NA
Flange Style RF NA Quantity NA
250 mm Thickness (note 1) Local only
(note 1) NA
SS316 NA
polyurethane Integral w/transmitter
SS316 NA
SS316
PERFORMANCE CHARACTERISTICS
Min press at design temp
Max press at design temp
Min working temperature
Accuracy rating
Min velocity URL
Min liquid conductivity
Output signal damping LRL
Min ambient working temp
Contacts ac rating
Contacts dc rating
Max sensor to receiver lg
0 At 84C
END EXTENSIONS 16 barg
End termination type
Bolting material
End termination material
Gasket/O ring material
NA Style NA 0C Max 84C
SS316L 0.5% span
(note 1) 0.1 m/s Max 10 m/s
rubber 5 uS/m
(note 1) URL (note 1)
SENSING ELEMENT 0C Max 84C
Electrode type
Insertion length
Electrode material
(note 1) NA At max NA
(note 1) NA At max NA
SS316 NA

COILS AND HOUSING
Housing construction type
Coil conn arrangement
Enclosure type no/class
Signal power source
Signal termination type
Cert/Approval type
Housing material
(note 1)
(note 1) ACCESSORIES
IP 65 Connecting cables length
Cable Glands
Ultrasonic cleaner style
Empty tube detector
Calibrator adaptor
Calibrator/configurator
NA
12-30Vdc For armoured cables, Exd IIC, IP45
(note 1) (note 1)
(note 1) (note 1)
ASTM B26 grade A356.0 T6, (note 1)
Alum. with polyurethane coating (note 1)

TRANSMITTER OR CONVERTER SPECIAL REQUIREMENTS
Housing type
Output signal type
Enclosure type no/class
Characteristic curve
Digital Communication std
Signal power source
Failsafe style
Integral indicator style
Signal termination type
Cert/Approval type
Mounting location/type
Failure/Diagnostic action
Enclosure material
(note 1) Custom tag
Reference specification
Compliance standard
Calibration report
Software configuration
SS wired-on
digital 3731-DSSA-4-14-0008
IP65 NA
Linear (note 1)
Yes (note 1)
9-24VDC
(note 1) PHYSICAL DATA
Minimum 4 digit LCD, Estimated weight
Face-to-face dimension
Overall height
Removal clearance
Signal conn nominal size
Mfr reference dwg

(note 1)
Integral junction box (note 1)
(note 1) (note 1)
inline (note 1)
Yes (note 1) Style (note 1)
ASTM B26 grade A356.0 T6, (note 1)
Alum. with polyurethane coating
110
111
112
113
114
115
116
117

CALIBRATIONS AND TEST
INPUT OR TEST OUTPUT OR SCALE
TAG NO/FUNCTIONAL IDENT

MEAS/SIGNAL/TEST

LRV

URV

ACTION

LRV

URV

88-FIT-XXX1; 88-FIT-XXX2 Flow rate-Analog output
Flow rate-Digital output
Flow rate-Freq output
Flow rate-Scale
Test pressure
(note 1) (note 1) (note 1) 0 m3/h 300 m3/h





118
119
120
121
122
123



COMPONENT IDENTIFICATIONS
COMPONENT TYPE MANUFACTURER MODEL NUMBER
Note 1 Note 1 Note 1



DOC. NO.: 3731-DSSA-4-13-0008 REV. 0 Page 3 of 3

Please mention certification/
approval required.
Please check IP rating
Please with
respect to P&ID.
1) Flow Meter shall be based on Foundation Fieldbus protocol. Please incorporate.
2) Material certification shall be provided.
3) Hazardous Area Certification for ZONE-2 shall be provided.

S-ar putea să vă placă și