Sunteți pe pagina 1din 7

TTL

Technical Guidelines
Revision No: 1.0



ZTE Confidential Proprietary


Dynamic RC3/RC4 Process Flow Design for ZXC10
BSSB



Copyright Notice:
Copyright 2004 ZTE Corporation Shenzhen P. R. China
All rights reserved. No part of this documentation may be excerpted, reproduced,
translated, annotated or duplicated, in any form or by any means without the prior written
permission of ZTE Corporation.
TTL
Technical Guidelines
Revision No: 1.0



I
Tabl e of Contents
1 RC3/RC4 Features 3
2 Dynamic RC3/RC4 Process Flow Design 5
TTL
Technical Guidelines
Revision No: 1.0



II
Li st of Fi gures & Tabl es
Figures
Fig.1 Dynamic RC3/RC4 process flow...................................................................... 5

Tables
Table 1. Forward Fundamental Channel and Forward Supplemental Channel
Modulation Parameters for 5 or 20 ms Frames for Radio Configuration 3............ 3
Table 2. Forward Fundamental Channel and Forward Supplemental Channel
Modulation Parameters for 5 or 20 ms Frames for Radio Configuration 4............ 3

TTL
Technical Guidelines
Revision No: 1.0



ZTE Confidential Proprietary 3
1 RC3/RC4 FEATURES
Because of the Walsh length of RC3 is 64 and the Walsh length of RC4 is 128, so the Walsh Code
capacity of RC3 is less than RC4. On the other hand, because of Code Rate of RC3 is less than RC4,
so the power consumption of RC3 is less than RC4.
The Dynamic RC3/RC4 process is the part of Resource Allocate Function. This process balance the
load of power and Walsh Code for the higher capacity of Carrier-Sector. Once a new call setup, the
process will judge which Radio Configuration(RC) would be use depond on the current load of Walsh
Code and Forward Power.

Shown in Table 1 and Table 2 are the detail features of RC3 and RC4.
Table 1. Forward Fundamental Channel and Forward Supplemental Channel Modulation
Parameters for 5 or 20 ms Frames for Radio Configuration 3

Notes:
1. N =1, 2, 4, 8, or 16, which yields data rates of 9600, 19200, 38400, 76800, or=153600 bps,
respectively.
2. If variable-rate Forward Supplemental Channel operation, flexible forward link data rates, or both
are supported, the parameters are determined from the specified number of channel bits per
frame, the maximum assigned number of channel bits per frame for the Forward Fundamental
Channel or the Forward Supplemental Channel, and the specified frame quality indicator length.

Table 2. Forward Fundamental Channel and Forward Supplemental Channel Modulation Parameters
for 5 or 20 ms Frames for Radio Configuration 4
TTL
Technical Guidelines
Revision No: 1.0



ZTE Confidential Proprietary 4

Notes:
1. N =1, 2, 4, 8, 16, or 32, which yields data rates of 9600, 19200, 38400, 76800, 153600, or 307200
bps, respectively.
2. If variable-rate Forward Supplemental Channel operation, flexible forward link data rates, or both
are supported, the parameters are determined from the specified number of channel bits per
frame, the maximum assigned number of channel bits per frame for the Forward Fundamental
Channel or the Forward Supplemental Channel, and the specified frame quality indicator length.
TTL
Technical Guidelines
Revision No: 1.0



ZTE Confidential Proprietary 5
2 DYNAMIC RC3/RC4 PROCESS FLOW
DESIGN
Shown in Fig.1 is the flow of Dynamic RC3/RC4 Process.
WalshCode_load_rate>
RC3_RC4_threshold
Start
WalshCode_load_rate>
Power_load_rate
RC = 4 RC = 3
NO
Y
e
s
NO
Resource
Allocate
PAR Optimization
Function(ZTE
Private)
END
a
b
c
d
Calculate
current
WalshCode_load_r
ate
Calculate
current
Power_load_rate
Y
e
s
e
f

Fig.1 Dynamic RC3/RC4 process flow

TTL
Technical Guidelines
Revision No: 1.0



ZTE Confidential Proprietary 6
Notes:
a. Calculate current WalshCode_load_rate.
b. Compare WalshCode_load_rate with RC3_RC4_ threshold which can be configurated in
OMC. If WalshCode_load_rate is great than RC3_RC4_threshold, goto step c. Otherwise
goto step e to choosing RC3.
c. Calculate current Power_load_rate.
d. Compare WalshCode_load_rate with Power_load_rate. If WalshCode_load_rate is great
than Power_load_rate, goto step e to choosing RC4. Otherwise goto step e to choosing RC3.
e. RC judgement.
f. PAR Optimization Function(ZTE Private Algorithm) and Resource Allocate.