Sunteți pe pagina 1din 5

Appd. Rev.

Revision Date
Prepared by
ABB AB - FACTS
Document No.
No. of sh.
Sheet
Rev Ind
Title (English)
Title (own language) Date
Issued by Dept
Approved by
Drawn by Assembly dwg
Vignesh
H stberg 2011-06-23
DM
Vignesh
1JNS10150D1MM 5
1
Grounding details
-
F10150
2011-08-08
Form
No
Design checked by
Sheet
Cont
Year W
eek
Dept
Rev Ind
Drawn by
801
Detail 2
X-Connection
801
808
808
801
Earthing along ladders
Fixing every
500 mm.
2011-05-17 VENDOR'S DRG. NO.-
UNIT: PACKAGE :
SCALE -
TITLE :
DESIGN
DRAWN
CHKD
APPROVED
DATE REV. SH.No.
PROJECT DRG.NO.-
CATEGORY OF DRG. APPROVAL INFORMATION REFERENCE RECORD CONSTRUCTION
SIZE A1
6MPTA INTEGRATED STEEL PLANT AT ANGUL, ORISSA
JINDAL STEEL & POWER LIMITED
-
1 of 1
0
C
0
9
1 0
O
I
S
MP
O
A
N
Y
MECON LIMITED
ASEA BROWN BOVERI
Vignesh
Vignesh
Katarina
Katarina
Grounding details
1:100
Detail 1
T-Connection
801 809
802
Ground shall be laid
1) on cable ladder
2) on floor
Note:
Item No. QTY. Drawing No. / Article No. Material,type,etc. Dimensions Description English
801 1 Cu-annealed 50mm2, L= 50m Cu-wire
802 1 Cu-annealed 150mm2, L= 400m Cu-wire
803 3 YCA050M10TN 50mm2 M10 Cable lug M10
804 13 YCA050M12TN 50mm2 M12 Cable lug M12
805 20 YCA150M10TN 150mm2 M10 Cable lug M10
806 160 YCA150M12TN 150mm2 M12 Cable lug M12
807 160 BSA 308676/00 120-240mm2,NGFR34D35DIA14 Grounding flag connector
808 18 YC26C26 C50-70/50-70 C-connector
809 31 YGHC34C34 150-240 and 15-240 mm2 C-connector
820 3 E16 594 60 RHS 1020 A Contact fitting
821 3 E16 594 66 RHS 1020/30A Contact fitting
822 1 E16 594 18 JVF 43 Contact fitting to earth
823 1 E16 529 20 Operating pole MGV-I-36
824 1 E16 594 42 Operating Socket JGS18
825 1 2xJK27-JLA34 95/1.8x4 2-Phase earthing device
826 1 2xJK27-JLA34 95/1.8x6 2-Phase earthing device
827 1 2xJK27-JLA34 95/1.8x8 2-Phase earthing device
828 1 E16 594 40 Tool storage rack
5012 23 Steel 8.8 Fe/Zn 45 M10x30 DIN 931 Hexagon bolt
5024 317 Steel 8.8 Fe/Zn 45 M12x40 DIN 931 Hexagon bolt
5025 3 Steel 8.8 Fe/Zn 45 M12x50 DIN 931 Hexagon bolt
5056 23 Steel 8 Fe/Zn 45 M10 Hexagon nut
5057 317 Steel 8 Fe/Zn 45 M12 Hexagon nut
5060 23 Steel Fe/Zn 10.5x20x2(M10) Washer
5062 317 Steel Fe/Zn 13x24x2.5(M12) Washer
6086 2 HSAF 12x120 Expander
5056
Section A-A
Wall bushing / Current transformer
801
5025 5057 804 5062
5012
To CT grounding terminal
1)
803 5060
2)
807
To Wall bushng plate
X
5057
824
825
826
823
827
1)
1)
1)
828
2)
801
802
5024
804
5062
A A
B
B
C C
822
5057 5025 6086
Section B-B
804
801
Arrangement for portable earthing
D
C
B
w
ill b
e
p
ro
s
e
cu
te
d
. A
B
B
A
B
u
s
e
d
fo
r a
n
y
u
n
a
u
th
o
riz
e
d
p
u
rp
o
s
e
. C
o
n
tra
v
e
n
tio
n
m
u
s
t n
o
t b
e
im
p
a
rte
d
to
a
th
ird
p
a
rty
n
o
r b
e
w
ritte
n
p
e
rm
is
s
io
n
, a
n
d
th
e
co
n
te
n
ts
th
e
re
o
f
T
h
is
d
o
cu
m
e
n
t m
u
s
t n
o
t b
e
co
p
ie
d
w
ith
o
u
t o
u
r
12 11 10 9 8 7 6 5 4 3 2
1
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12
H
G
F
E
A
Appd. Rev. Revision Date
Prepared by
ABB AB - FACTS
Document No.
No. of sh.
Sheet
Rev Ind
Title (English)
Title (own language) Date
Issued by Dept
Approved by
Drawn by Assembly dwg
Vignesh
H stberg 2011-06-23
Vignesh
1JNS10150D1MM 5
2
Grounding details
-
F10150
2011-08-08
Form
No
Design checked by
Sheet
Cont
Year W
eek
Dept
Rev Ind
Drawn by
General
Control cubicles
CU- bar
808 801
804
civil contractor
Gate Post and Gate
Flexible braid, Delivered by
To ground grid
To ground grid
Fence and Fence Post
Delivered by civil
contractor
Pump unit
Support for
control cubicle
801
804 5062 5057 5024
807
Current transformer
806 5024 5062 5057
5056 5060 5012 803
Current transformer
5024 5057 5062 806
809
803 5060 5056 5012
806 5024 5057 5062
802
802
Steel structure general
Raisers with two holes d=14mm
and 45mm between supplied by
INABB
All grounding material above ground
level are supplied by SEPOW
806 5024 5057 5062
w
ill b
e
p
ro
s
e
cu
te
d
. A
B
B
A
B
u
s
e
d
fo
r a
n
y
u
n
a
u
th
o
riz
e
d
p
u
rp
o
s
e
. C
o
n
tra
v
e
n
tio
n
m
u
s
t n
o
t b
e
im
p
a
rte
d
to
a
th
ird
p
a
rty
n
o
r b
e
w
ritte
n
p
e
rm
is
s
io
n
, a
n
d
th
e
co
n
te
n
ts
th
e
re
o
f
T
h
is
d
o
cu
m
e
n
t m
u
s
t n
o
t b
e
co
p
ie
d
w
ith
o
u
t o
u
r
12 11 10 9 8 7 6 5 4 3 2
1
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12
H
G
F
E
D
C
B
A
Appd. Rev. Revision Date
Prepared by
ABB AB - FACTS
Document No.
No. of sh.
Sheet
Rev Ind
Title (English)
Title (own language) Date
Issued by Dept
Approved by
Drawn by Assembly dwg
Vignesh
H stberg 2011-06-23
Vignesh
1JNS10150D1MM 5
3
Grounding details
-
F10150
2011-08-08
Form
No
Design checked by
Sheet
Cont
Year W
eek
Dept
Rev Ind
Drawn by
Surge capacitor
Connection to
busbar.
802
809
5024 5057 5062
806 5024 5057 562
806
5062
Water and light guides
801
808
804
5024 5057
801
Capacitor
Capacitor
807 5024 5057 5062
802
802
803
Capacitor With Current
Transformer
5012
Three legs to be grounded.
809
5056 5060
802
807
5024
5057
5062
802
807
5024
5057
5062
w
ill b
e
p
ro
s
e
cu
te
d
. A
B
B
A
B
u
s
e
d
fo
r a
n
y
u
n
a
u
th
o
riz
e
d
p
u
rp
o
s
e
. C
o
n
tra
v
e
n
tio
n
m
u
s
t n
o
t b
e
im
p
a
rte
d
to
a
th
ird
p
a
rty
n
o
r b
e
w
ritte
n
p
e
rm
is
s
io
n
, a
n
d
th
e
co
n
te
n
ts
th
e
re
o
f
T
h
is
d
o
cu
m
e
n
t m
u
s
t n
o
t b
e
co
p
ie
d
w
ith
o
u
t o
u
r
12 11 10 9 8 7 6 5 4 3 2
1
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12
H
G
F
E
D
C
B
A
Appd. Rev. Revision Date
Prepared by
ABB AB - FACTS
Document No.
No. of sh.
Sheet
Rev Ind
Title (English)
Title (own language) Date
Issued by Dept
Approved by
Drawn by Assembly dwg
Vignesh
H stberg 2011-06-23
Vignesh
1JNS10150D1MM 5
4
Grounding details
-
F10150
2011-08-08
Form
No
Design checked by
Sheet
Cont
Year W
eek
Dept
Rev Ind
Drawn by
5062 5057 5024 806
802
806 5057 5024 5062
802
806
809
Disconnector/Earth switch
802
Reactors (typical)
The ground conductor
may not form closed loop.
Mounting base.
5024 5062 5057
807
802
w
ill b
e
p
ro
s
e
cu
te
d
. A
B
B
A
B
u
s
e
d
fo
r a
n
y
u
n
a
u
th
o
riz
e
d
p
u
rp
o
s
e
. C
o
n
tra
v
e
n
tio
n
m
u
s
t n
o
t b
e
im
p
a
rte
d
to
a
th
ird
p
a
rty
n
o
r b
e
w
ritte
n
p
e
rm
is
s
io
n
, a
n
d
th
e
co
n
te
n
ts
th
e
re
o
f
T
h
is
d
o
cu
m
e
n
t m
u
s
t n
o
t b
e
co
p
ie
d
w
ith
o
u
t o
u
r
12 11 10 9 8 7 6 5 4 3 2
1
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12
H
G
F
E
D
C
B
A
Appd. Rev. Revision Date
Prepared by
ABB AB - FACTS
Document No.
No. of sh.
Sheet
Rev Ind
Title (English)
Title (own language) Date
Issued by Dept
Approved by
Drawn by Assembly dwg
Vignesh
H stberg 2011-06-23
DM
Vignesh
1JNS10150D1MM 5
5
Grounding details
-
F10150
2011-08-08
Form
No
Design checked by
Sheet
Cont
Year W
eek
Dept
Rev Ind
Drawn by
w
ill b
e
p
ro
s
e
cu
te
d
. A
B
B
A
B
u
s
e
d
fo
r a
n
y
u
n
a
u
th
o
riz
e
d
p
u
rp
o
s
e
. C
o
n
tra
v
e
n
tio
n
m
u
s
t n
o
t b
e
im
p
a
rte
d
to
a
th
ird
p
a
rty
n
o
r b
e
w
ritte
n
p
e
rm
is
s
io
n
, a
n
d
th
e
co
n
te
n
ts
th
e
re
o
f
T
h
is
d
o
cu
m
e
n
t m
u
s
t n
o
t b
e
co
p
ie
d
w
ith
o
u
t o
u
r
12 11 10 9 8 7 6 5 4 3 2
1
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12
H
G
F
E
D
C
B
A
To be mounted on the wall
close to the door opening
821
820
822
803
Section C-C
801
807
5024
5057
5062
807
5024
5057
5062
807
5024
5057
5062

S-ar putea să vă placă și