Sunteți pe pagina 1din 3

IGC INC 3702 Rushland Ave Toledo, OH 43613 Tel: 419-944-2461 Fax: 419-944-2463

Model STL
www.igccorporation.com
SAND TRAP LOUVER


DESCRIPTION
STL Sand Louvers are designed for removal of dust and sand
particles. A double layer of vertical blades design provides
27% free area, low pressure drop, high sand removal
efficiency and vision proof design.





STANDARD CONSTRUCTION
Frame:


Blades:


Screen:


Construction:

Finish:

Dimensions:





100 mm deep channel, 1.2 mm thick
galvanized steel

1.2 mm thick galvanized steel, vertical, sight
proof

13 mm removable expanded aluminium
bird screen. Located on interior

Mechanically fastened and welded

Mill with touch up on welds

Minimum size: 300 mm x 300 mm
Maximum size: 2400 mm x 2400 mm
(single section)
Maximum multiple section size: Unlimited
W (width) and H (height) are opening
sizes. Louvers are made 6 mm undersized.
OPTIONS
1.6 mm or 2.0 mm Aluminum Construction
Variety of Bird and Insect Screens
304 or 316 Stainless Steel Construction
Flanged Frame
Filter Rack
Washable Filters
Hinged Frame
Clip Angles
Selection of Finishes: Super Durable Polyester Powder
coatings, Kynar/PVF and anodized.




1.6 mm Galvanized Steel Construction
IGC INC 3702 Rushland Ave Toledo, OH 43613 Tel: 419-944-2461 Fax: 419-944-2463
STL Performance Data
Below STL performance charts are based on tests performed at Cert-Aire Laboratory at Arlington
Heights, Illinois based on AMCA Publication 511 for Air Performance and Water Penetration and
ASHRAE Standard 52-76 for sand removal.





































Pressure Drop
Sand Removal Efficiency
IGC INC
STL S
2
L
S
S
S
W

Published
Heights,
ASHRAE


TA








PROJEC
LOCATI
CONTRA














3702 R
and Tra
7% Free Area
Low pressure
and efficienc
tandard 52-7
ight proof de
Withstand a b
d performan
Illinois base
E Standard 52
AG Q








CT
ION
ACTOR
Rushland Ave
ap Louve
a, 1200 x 120
drop, tested
cy removal o
76 test metho
esign.
basic wind sp
nce charts ar
ed on AMCA
2-76 for sand
QUANTITY
Toledo, O
er Featur
00 mm Test S
in accordanc
of approxima
od.
peed of 145 K
re based on
A Publication
d removal.
DIM
WIDTH










OH 43613
res and S
Size
ce with AMC
ately 90% m
KPH (equivale
tests perfor
n 511 for Ai
MENSIONS
HEIGH










Tel: 419-9
Specific
CA Publicatio
measured dur
ent of a wind
rmed at Cer
Air Performan
HT










DAT
944-2461
ations
n 511
ring tests de
d load of 0.96
rt-Aire Labo
nce and Wa
OPT
TE
Fax: 419-94
escribed in A
6 kPa)
oratory at A
ater Penetrat
TIONS
44-2463
ASHRAE
Arlington
tion and

S-ar putea să vă placă și