Pacemaker type VVIR

Model number
Model name ESPRIT SR
Longevity
9.8 years (70 bpm, 2.5 v, 0.5 ms,
500 ohms, Holter ON, Sensor
ON)
Size 7.5 cc, 19 g
Safe R mode
Cap confirmation
Auto threshold auto- monitor - off
Auto lead impedance measurement every 6 hours
Stored iEGM
ECG triggers
Rate response accelerometer sensor (G)
MRI compatible no
Pacing configuration unipolar - bipolar
Auto implantation
Auto sensitivity auto- monitor
AV hysteresis
Atrial arrhythmia prevention
Dynamic AV delay
Rest rate
Sudden rate drop smoothing
Sleep Apnea Monitoring (SAM)
Rate Hysteresis Yes
Test assistant smartcheck No
Regulatory Status "
DDDR VVIR PRENIUM DDDR PRENIUM
ESPRIT DR REPLY SR REPLY DR
9 years (70 bpm, 2.5 v, 0.5 ms,
500 ohms, 100% Atrial pacing
and 15% Ventricular pacing,
diagnostic ON)
11.4 years (60 bpm, 2.5 v, 0.35
ms, 750 ohms, 100% pacing
EGM and diagnostic ON)
9.6 years in DDDR mode (60 bpm,
2.5 v, 0.35 ms, 750 ohms, 100% A&V
pacing EGM and Diagnostic ON)
12 years in SafeR mode (60 bpm, 2.5
v, 0.35 ms, 50% A pacing, 5% V
pacing, 750 ohms, EGM and
diagnostic ON)
8 cc, 20 g 7.5 cc, 19 g 8 cc, 20 g
AAI <=> DDD
minimum ventricular amplitude minimum ventricular amplitude minimum ventricular amplitude
auto - monitor - off auto - monitor - off auto - monitor - off
every 6 hours every 6 hours every 6 hours
14 stored episodes with
markers and EGM, up to 3.5 min
A+V
7 stored episodes with markers
and EGM, 1.6 min A or V
22 stored episodes with markers and
EGM, 5.5 min, A+V
Atrial and Ventricular burst,
Mode switching Atrial and Ventricular burst
Mode switching, Atrial bursts,
Ventricular bursts, Switches in SafeR
mode (AV Bloks)
accelerometer sensor (G)
Minute ventilation (MV) and
Accelerometer (G)
MV+G / MV / G
Minute ventilation (MV) and
Accelerometer (G) MV+G /
MV / G
no no no
unipolar - bipolar unipolar - bipolar unipolar - bipolar
Auto measure of lead
impedance and configuration
programming
Auto measure of lead impedance.
SafeR mode and configuration
programming
auto- monitor auto- monitor auto- monitor
Dplus Dplus
Overdrive, Pause suppression, PAC
acceleration
rest, exercise, auto
reprogramming for PMT
protection
rest, exercise, auto reprogramming
for PMT protection
based on physical activity based on physical activity based on physical activity
smoothing smoothing smoothing, acceleration
Yes Yes Yes
No Yes Yes
" " "
VVIR PRENIUM 2 DDDR PRENIUM 2
REPLY 200 SR REPLY 200 DR
11.4 years (60 bpm, 2.5 v, 0.35 ms, 750
ohms, 100% pacing EGM and
diagnostic ON)
9.6 years in DDDR mode (60 bpm, 2.5
v, 0.35 ms, 750 ohms, 100% A&V
pacing EGM and Diagnostic ON) 12
years in SafeR mode (60 bpm, 2.5 v,
0.35 ms, 50% A pacing, 5% V pacing,
750 ohms, EGM and diagnostic ON)
7.5 cc, 19 g 8 cc, 20 g
AAI <=> DDD
minimum ventricular amplitude minimum ventricular amplitude
auto - monitor - off auto - monitor - off
every 6 hours every 6 hours
7 stored episodes with markers and
EGM, 1.6 min A or V
22 stored episodes with markers and
EGM, 5.5 min, A+V
Atrial and Ventricular burst
Mode switching, Atrial bursts,
Ventricular bursts, Switches in SafeR
mode (AV Bloks)
Minute ventilation (MV) and
Accelerometer (G) MV+G / MV
/ G
Minute ventilation (MV) and
Accelerometer (G)
MV+G / MV / G
no no
unipolar - bipolar unipolar - bipolar
Auto measure of lead impedance and
configuration programming
Auto measure of lead impedance.
SafeR mode and configuration
programming
auto- monitor auto- monitor
Dplus
Overdrive, Pause suppression, PAC
acceleration
rest, exercise, auto reprogramming for
PMT protection
based on physical activity based on physical activity
smoothing smoothing, acceleration
Monitoring on-off, monitoring period
choice .
Respiratory disturbance index; number
and duration of events in diagnostics
Monitoring on-off, monitoring period
choice .
Respiratory disturbance index; number
and duration of events in diagnostics
Yes Yes
Yes Yes
" "
VVIR - Pro MRI DDDR - Pro MRI
KORA 100 SR KORA 100 DR
11.4 years (60 bpm, 2.5 v, 0.35 ms,
750 ohms, 100% pacing EGM and
diagnostic ON)
9.6 years in DDDR mode (60 bpm, 2.5
v, 0.35 ms, 750 ohms, 100% A&V
pacing EGM and Diagnostic ON)
12 years in SafeR mode (60 bpm, 2.5
v, 0.35 ms, 50% A pacing, 5% V
pacing, 750 ohms, EGM and
diagnostic ON)
7.5 cc, 19 g 8 cc, 20 g
AAI <=> DDD
minimum ventricular amplitude minimum ventricular amplitude
auto - monitor - off auto - monitor - off
every 6 hours every 6 hours
7 stored episodes with markers
and EGM, 1.6 min A or V
22 stored episodes with markers and
EGM, 5.5 min, A+V
Atrial and Ventricular burst
Mode switching, Atrial bursts,
Ventricular bursts, Switches in SafeR
mode (AV Bloks)
Minute ventilation (MV) and
Accelerometer (G)
MV+G / MV / G
Minute ventilation (MV) and
Accelerometer (G)
MV+G / MV / G
Automatic MRI mode Automatic MRI mode
unipolar - bipolar unipolar - bipolar
Auto measure of lead impedance
and configuration programming
Auto measure of lead impedance.
SafeR mode and configuration
programming
auto- monitor auto- monitor
Dplus
Overdrive, Pause suppression, PAC
acceleration
rest, exercise, auto reprogramming
for PMT protection
based on physical activity based on physical activity
smoothing smoothing, acceleration
Monitoring on-off, monitoring
period choice . Respiratory
disturbance index; number and
duration of events in diagnostics
Monitoring on-off, monitoring
period choice .
Respiratory disturbance index;
number and duration of events in
diagnostics
Yes Yes
Yes Yes
" "