Sunteți pe pagina 1din 2

2007 Thermaco, Inc.

All rights reserved Patented/Patents Pending Specications subject to change without notice
10/07 1 646 Greensboro St. Asheboro, N. C. 27204-2548 Phone (336) 629-4651 North America: (800) 633-4204
E-mail: info@thermaco.com Online: www.big-dipper.com
Big Dipper

AST Central Automatic


Grease Removal Systems
Exterior: 304 Stainless Steel, Bright Finish
Interior: Rotationally Molded Polyethylene
115 VAC, 60 Hz, 1055 Watts (9.1 Amps)
125 GPM
2
40 Pounds Per Hour
300+ Pounds
50 PSI min., 12 GPM
TECHNICAL DATA
Materials:
Electrical:
Maximum Inlet Flow Rate:
Number of Skimming Wheels:
Skimming Rate:
Grease Retention Capacity:
Eductor Pump Operation Water Requirements:
FEATURES:
Fully automatic self cleaning cycle. Re-
moves collected grease, oils & solids from
tank without any operator assistance. Comes
complete with two 24-hour timers.
Constructed of corrosion resistant materi-
als suitable for installation in virtually any
location. Attractive sanitary Stainless Steel
exterior.
Integrated Motor/Grease Outlet/Heater/Lids
enables fast, do-it-yourself unit operation
reversal.
Easy lift grease collectors simplify grease
collection container emptying.
Compact footprint.
24.5
23.5
8.75
21.85
52.4
16.5
16.5
27.1
55.4
24.5
4 PIPE
INLET/OUTLET
INLET
INLET OUTLET
DUAL GC-6
GREASE
COLLECTORS
6 QUART
CAPACITY EA.
END VIEW
SIDE VIEW
TOP VIEW
MOTOR/TIMER
ENCLOSURE
14 CLEARANCE FROM
TOP OF TANK REQUIRED FOR
STRAINER BASKET & LID REMOVAL
OUTLET
W-1250-AST Specications
21
6
17.5
30.25
30.5
5.5
1/2 FEMALE
NPT WATER
SUPPLY
CONNECTION
TO WATER
SUPPLY
0.5" FEMALE
CONNECTOR
2007 Thermaco, Inc. All rights reserved Patented/Patents Pending Specications subject to change without notice
10/07 2
Install P trap on outlet connection
of tank. (Note: the unit already has
an internal gas trap).
DONT . . .
Reduce pipe size on outlet piping.
INSTALLATION INFORMATION
Suggested Minimum Footprint Dimensions
D
O
.
.
.
.
646 Greensboro St. Asheboro, N. C. 27204-2548 Phone (336) 629-4651 North America: (800) 633-4204
E-mail: info@thermaco.com Online: www.big-dipper.com
NOTE: Drawing for reference only. Equip-
ment must be installed in compliance with
all applicable laws, regulations and codes,
including plumbing codes. Installation should
be performed by a qualied plumber.
Big Dipper

AST Central Automatic


Grease Removal Systems
Allow a minimum of 14 clearance from
top of tank for removal of unit lid.
READ instruction manual included with
system before doing anything.
Install unit allowing for the minimum
clearances shown.
Provide a min. 50 PSI, 12 GPM Water
Supply for solids pump operation
Make sure the height above the
Internal Strainer Access Cover is
enough to remove the strainer.
Make piping connections with rubber
No Hub connectors.
Keep outlet piping as straight as pos-
sible. Use only sweep connections.
Install vent on outlet piping.
Fill the tank with water before ener-
gizing the power to the motor and
heater.
Set Programmable Time Controller for
proper operating times.
INSTALLATION INFORMATION
Suggested Minimum Footprint Dimensions
Job Specication:
Grease and oils separator(s) shall be Thermaco Big Dipper automatic grease/oil recovery system(s) as manufac-
tured by Thermaco, Inc., Asheboro, North Carolina as noted on plans.
Separator Specications:
Furnish and install ___ Thermaco Big Dipper Model No. W-1250-AST, bright nish type 304 stainless steel exte-
rior, rotationally molded polyethylene interior automatic self-cleaning grease and oil recovery separator(s) for oor
mounted or partially recessed installation, rated at 125 gallons per minute peak ow, 300 pounds of grease capacity
and including as an integral part of the unit, two rotating gear hydrophobic wheel assemblies for automatic grease/
oil removal, an integral ow control device, two self-regulating enclosed electric immersion heaters, a vessel vent,
an integral gas trap, two integral programmable 24-hour multi-event time controls, eld reversible motor locations,
eld reversible grease/oil sump outlets, quick release stainless steel lid clamps, a gasketted and fully removable
304 stainless steel lid, lift-out lter basket access, an eductor transfer pump controlled by repeat cycle timer, and
two separate grease and oils collection containers. Eductor pump shall be supplied with a 0.5 female connector
for attachment to facility-supplied water supply. Eductor pump shall be supplied with an approved vacuum breaker.
Electric assembly shall be tested to comply with pertinent sections of the Standards for Safety ANSI/UL 73 and/or
ANSI/UL 1004. Each electric motor equipped with overload protection.
4
8.75
8.75
6.5
4.5
6 6
52.4
INLET OUTLET
GC-6 GREASE
COLLECTORS
W-1250-AST Specications
6